• 제목/요약/키워드: Line Trace

검색결과 194건 처리시간 0.025초

Online preconcentration and preelutioin for the ion chromatographic determination of trace anions in high-sulfate wastewater

  • Song, Kyung-Sun;Kim, Sang-Yeon;Cheong, Young-Wook
    • 한국환경과학회:학술대회논문집
    • /
    • 한국환경과학회 2005년도 봄 학술발표회지 제14권(제1호)
    • /
    • pp.327-328
    • /
    • 2005
  • Trace anions in high-sulfate wastewater from mainly derelict mines were determined by ion chromatography with on-line preconcentration and preelution technique. As the sample was preconcentrated and more strongly held ions were preeluted to the principal separation system, this approach was highly effective in removing large concentration of sulfate in high-sulfate wastewater. With this practical on-line preelution treatment, the peaks of fluoride and chloride showed good resolution even when the sulfate concentration was as high as 2000 mg/L and the analyzed total metal concentration was above 500 mg/L.

  • PDF

적응적 고차 상관 처리를 이용한 차량의 주행 궤적 검출법 (Vehicle Tracing Method Using Adaptive High Order Correlation Analysis)

  • 장경영;오재응;좌등탁송
    • 한국자동차공학회논문집
    • /
    • 제4권3호
    • /
    • pp.73-82
    • /
    • 1996
  • Vehicle movement detection by high order correlation analysis of optical sensor array signals is introduced. The optical sensors observe the road which is assumed to be a non-uniform speckle-like texture. The measurement system is applicable to general robotic movement detection because : 1) It employs a non-contact measurement method, 2) The system can be made very compact, and 3) It enables approximation of the movement trace with a sequence of arcs instead of the conventional connection of simple line segments. In this work, we have looked into estimation of running trace of an autonomous vehicle by observing the ground pattern.

  • PDF

AFCI용 온도보상회로의 ASIC화에 관한 연구 (A Study on the ASIC of Temperature Compensation Circuit for AFCI)

  • 양승국;신명호
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.293-296
    • /
    • 2009
  • 2002부터 미국에서 전기화재 보호를 위하여 AFCI(Arc Fault Circuit Interrupter)사용이 의무화되었으며 중성선의 선로저항을 이용하여 아크를 검출하는 방식의 AFCI의 경우 중성선 선로저항의 저항온도계수에 대한 온도보상이 필요하다. 이러한 온도보상회로를 주문형반도체(ASIC)에서 구현하는 방안을 제시하고 ARC 신호에 대하여 시뮬레이션하여 전기적 특성 및 온도특성을 검증하였다.

  • PDF

Determination of Trace Anions in Concentrated Hydrogen Peroxide by Direct Injection Ion Chromatography with Conductivity Detection after Pt-Catalyzed On-Line Decomposition

  • 김도희;이보경;이동수
    • Bulletin of the Korean Chemical Society
    • /
    • 제20권6호
    • /
    • pp.696-700
    • /
    • 1999
  • A method has been developed for the determination of trace anion impurities in concentrated hydrogen peroxide. The method involves on-line decomposition of hydrogen peroxide, ion chromatographic separation and subsequent suppressed-type conductivity detection. H2O2 is decomposed in Pt-catalyst filled Gore-Tex membrane tubing and the resulting aqueous solution containing analytes is introduced to the injection valve of an ion chromatograph for periodic determinations. The oxygen gas evolving within the membrane tubing escapes freely through the membrane wall causing no problem in ion chromatographic analysis. Decomposition efficiency is above 99.99% at a flow rate of 0.4mL/min for a 30% hydrogen peroxide concentration. Analytes are quantitatively retained. The analysis results for several brands of commercial hydrogen peroxides are reported.

역추적 방식의 시스토릭 어레이 구조를 가진 연판정 비터비 복호기의 설계 (VLSI Design of Soft Decision Viterbi Decoder Using Systolic Array Architecture)

  • 김기보;김종태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 G
    • /
    • pp.3199-3201
    • /
    • 1999
  • Convolutional coding with Viterbi decoding is known as a powerful method for forward error correction among many kinds of channel coding methods. This paper presents a soft decision Viterbi decoder which has systolic array trace-back architecture[1]. Soft decision is known as more effective method than hard decision and most of digital communication systems use soft decision. The advantage of using a systolic array decoder is that the trace-back operation can be accomplished continuously in an array of registers in a pipe-line fashion, instead of waiting for the entire trace-back procedure to be completed at each iteration. Therefore it may be suitable for faster communication system. We described operations of each module of the decoder and showed results of the logic synthesis and functional simulation.

  • PDF

가변적인 통신지연시간을 갖는 원격 작업 환경을 위한 실시간 햅틱 렌더링 (Real-Time Haptic Rendering for Tele-operation with Varying Communication Time Delay)

  • 이경노;정성엽
    • 동력기계공학회지
    • /
    • 제13권2호
    • /
    • pp.71-82
    • /
    • 2009
  • This paper presents a real-time haptic rendering method for a realistic force feedback in a remote environment with varying communication time-delay. The remote environment is assumed as a virtual environment based on a computer graphics, for example, on-line shopping mall, internet game and cyber-education. The properties of a virtual object such as stiffness and viscosity are assumed to be unknown because they are changed according to the contact position and/or a penetrated depth into the object. The DARMAX model based output estimator is proposed to trace the correct impedance of the virtual object in real-time. The output estimator is developed on the input-output relationship. It can trace the varying impedance in real-time by virtue of P-matrix resetting algorithm. And the estimator can trace the correct impedance by using a white noise that prevents the biased input-output information. Realistic output forces are generated in real-time, by using the inputs and the estimated impedance, even though the communication time delay and the impedance of the virtual object are unknown and changed. The generated forces trace the analytical forces computed from the virtual model of the remote environment. Performance is demonstrated by experiments with a 1-dof haptic device and a spring-damper-based virtual model.

  • PDF

듀티비 패턴을 이용한 승압형 정류기의 고역률 구현에 관한 연구 (A Study on High Power-Factor Control of Boost Type Rectifier Using Duty Cycle Pattern)

  • 이교범;이광원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.1934-1936
    • /
    • 1998
  • This paper proposes a new control scheme for enhanced power factor in the boost type AC/DC rectifier. The control scheme is to generate duty-cycle pattern without instantaneous measurement of the input line current. With a very simple controller structure the line current is forced to trace a sinusoid in phase with input voltage. The simulation results show the validity of the proposed control scheme.

  • PDF

Spectrophotometric Determination of Ultra trace Tri & Hexavalent Chromium by Using on-line Flow Injection Analysis with Dual Pre-concentration Column

  • Jung, Sung-Woon;Lim, Hyun-Woo;Kang, Chul-Ho;Choi, Yong-Wook
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권9호
    • /
    • pp.3437-3442
    • /
    • 2011
  • An on-line flow injection analysis with dual pre-concentration method was developed to determine the ultra trace tri and hexavalent chromium in water. In this system, the cation and anion pre-concentration columns were combined with a 10-port injection valve and then used to separate and concentrate Cr (III) and Cr (VI) selectively. The two species of concentrated chromium were sequentially eluted and determined by using HCl-KCl buffer of pH 1.8 as an eluent. Cr (III) was oxidized by hydrogen peroxide to Cr (VI). It was detected spectrophotometrically at 548 nm by complexation with DPC (diphenylcarbazide). Several factors such as concentration of $H_2O_2$, DPC and coil length in reaction condition were optimized. The linear range for Cr (III) and Cr (VI) was 0.1-50 ${\mu}g$/L. The limit of detections ($3{\sigma}$) of Cr (III) and Cr (VI) were 52 ng/L and 44 ng/L under the optimized FIA system, and their recoveries 98% and 103%, respectively. This method was applied to analyze contamination level of chromium species in tap water, groundwater and bottled water.

Line of Sight Vector Estimation using UWB for Augmented Reality Based Indoor Location Monitoring System

  • Chun, Sebum;Seo, Jae-Hee;Lee, Sangwoo;Heo, Moon-Beom
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제5권3호
    • /
    • pp.145-156
    • /
    • 2016
  • A variety of methods for indoor positioning systems have been underway to ensure the safety of emergency rescuers who are working in dangerous situations such as fire fighters. However, since most systems display locations of rescue workers in two-dimension (2D)-based maps, it is difficult for a commander located in the outside to recognize locations of rescuers inside the building intuitively. An augmented reality (AR)-based indoor positioning monitoring system can display locations of rescuer inside the building that can be seen by commanders to help intuitive recognition of positioning. To monitor AR-based indoor positioning, it is necessary to have an estimation technique of line of sight vector of observers. In the present study, an estimation technique of a line of sight vector using ultra-wide band tranceiver installed inside the indoor to trace locations is presented.

On-line SPE-HPLC Method using Alumina Filtering to Selectively Extract Phenolic Compounds from Environmental Water

  • Lee, Sung-Kwang
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권12호
    • /
    • pp.3755-3759
    • /
    • 2010
  • A on-line SPE (solid phase extraction)-HPLC preconcentration method was developed for the determination of phenolic compounds at trace levels in environmental water sample. XAD-4 and Dowex 1-X8 were used as sorbent in the on-line SPE-HPLC method for the selective enrichment of nine phenolic compounds, which are included in the priority pollutants list of the US EPA. Also alumina prefiltering considerably reduced the amount of interfering peaks due to humic substances that could accumulated due to the preconcentration step and prevent quantification of polar phenolic compounds in environmental water samples. This method was used to determine the phenolic compounds in tap and river water and superiority to the US EPA 625 method in its enrichment factor, pretreatment time, recoveries, and detection limit. The limits of detection were in the range of $0.3-0.9\;{\mu}g/L$ in tap water sample.