Current Limiting and Interrupting Operation of Hybrid Self-Excited Type Superconducting DCCB

  • Choi, S.J.;Lim, S.H.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제20권4호
    • /
    • pp.55-59
    • /
    • 2018
  • Currently, the development of industry makes needs larger electric supply. Providers must consider the efficiency about losses and reliability of the system. In this case, DC power system can save electrical energy; long-distance transmission line losses. Relevance to switch technology with a voltage-source converter (VSC) in AC-DC conversion system have been researched. But, protection device of DC-link against fault current is still needed to study much. VSC DC power system is vulnerable to DC-cable short-circuit and ground faults, because DC-link has a huge size of capacitor filter which releases extremely large current during DC faults. Furthermore, DC has a fatal flaw that current zero crossing is nonexistence. To interrupt the DC, several methods which make a zero crossing is used; parallel connecting self-excited series LC circuit with main switch, LC circuit with power electronic device called hybrid DC circuit breaker. Meanwhile, self-excited oscillator needs a huge size capacitor that produces big oscillation current which makes zero crossing. This capacitor has a quite effective on the price of DCCB. In this paper, hybrid self-excited type superconducting DCCB which are using AC circuit breaker system is studied by simulation tool PSCAD/EMTDC.

YBCO 박막을 이용한 3상 6.6kV 저항형 초전도 한류기 제작 및 시험 (Fabrication and Test of the Three-Phase 6.6 kV Resistive Superconducting Fault Current Limiter Using YBCO Thin Films)

  • 심정욱;김혜림;박권배;강종성;이방욱;오일성;현옥배
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권3호
    • /
    • pp.50-55
    • /
    • 2004
  • We fabricated and tested a resistive type superconducting fault current limiter (SFCL) of three-phase 6.6 $kV_{rms}/200 A_{rms}$ rating based on YBCO thin films grown on sapphire substrates with a diameter of 4 inches, Short circuit tests were carried out at a accredited test facility for single line-to- ground faults, phase-to-phase faults and three-phase faults, Each phase of the SFCL was composed of 8${\times}$6 elements connected in series and parallel respectively. Each element was designed to have the rated voltage of 600 $V_{rms}$. A NiCr shunt resistor of 23 Ω was connected to each element for simultaneous quenches. Firstly, single phase-to-ground fault tests were carried out. The SFCL successfully developed the impedance in the circuit within 0.12 msec after fault and controlled the fault current of 10 $kA_{rms} below 816 A_{peak}$ at the first half cycle. In addition, in case of phase-to-phase fault and three- phase fault test. simultaneous quenches among the SFCLs of the phases successfully accomplished. In conclusion. the SFCL showed excellent performance of current limitation upon fault and stable operation regardless of the amplitude of fault currents.

고속철도의 소음 특성과 전파현상 (Highspeed Train : Sound Power and Noise Propagation Characteristics)

  • 김정태;은희준
    • 소음진동
    • /
    • 제6권3호
    • /
    • pp.349-355
    • /
    • 1996
  • For a rail traffic noise, a typical source has a length of 200m - 400m so that the noise pollution areas have been located in the transition regions where the sound level drops between 3dB/dd and 6dB/dd. Therefore, in this region, parameters such as a horizontal distance from the track, the geometry of the ground surface, the environmental effect, and the boundary impedance condition play import roles, especially in our nation's situation. In this study, modelling techniques for the finite length of noise source have been investigated in order to evaluate the rail traffic noise level. Then. noise correction value .${\Delta}$SPL for various location in the track region is represented by the non-dimensionalized horizontal and parallel distance from the track. As an application, a high speed train is examined. Beas on the noise data measured for a Eurostar in France, the sound power value per unit length $H_1$is calcuated. It turns out that$H_1$is 109 dB. Overall sound power from the highspeed train to be serviced in our country is expected to 135 dBA.

  • PDF

모형실험에 의한 토공구조물의 침투거동특성 (The Characteristics for Seepage Behaviour of Soil Structure by Modeling Tests)

  • 신방웅;강종범
    • 한국안전학회지
    • /
    • 제14권4호
    • /
    • pp.158-167
    • /
    • 1999
  • In parallel flow condition, to estimate the stability of the extended embankment constructed on a permeable foundation ground, a laboratory model test was performed due to extended materials and water level increasing velocity of a flood period. A laboratory model test was peformed for different permeability coefficients ($K_1=2.0{\times}10^{-5}cm/sec,\;K_2=1.5{\times}10^{-4}cm/sec,\;K_3=2.3{\times}10^{-3}cm/sec$) using seepage. The fluctuation of water level occurring to an extended embankment was analyzed by laboratory model tests as vary the increasing velocity of water level with 0.6cm/min, 1.2cm/min, 2.4cm/min respectively. In analysis results, the increase of water level into embankment occurs rapidly because seepage water moving along with a permeable soil flow into embankment. The larger the permeability coefficient of an extended part is the longer initial seepage distance, and the exit point of downstream slope is gradually increased and then shows unstable seepage behavior as occurring partial collapse. As the increasing velocity of water level increase, the initial seepage line is formed low, and the discharge increases. Therefore, the embankment extended by a lower permeable soil than existing embankment shows stable seepage behavior because an existing embankment plays a role as filter for an extended part.

  • PDF

실리콘 v-groove를 이용한 광섬유-광검출기 어레이 모듈 제작 (Fabrication of the Optical Fiber-Photodiode Array Module Using Si v-groove)

  • 정종민;지윤규;박찬용;유지범;박경현;김홍만
    • 전자공학회논문지A
    • /
    • 제31A권6호
    • /
    • pp.88-97
    • /
    • 1994
  • We describe the design, fabrication, and performance of the optical fiber-photodiode 1$\times$12 arry module using mesa-type InS10.53T GaS10.47TAS/INP 1$\times$12 PIN photodiode array. We fabricated the PIN PD array for high-speed optical fiber parallel data link optimizing quantum efficiency, operating speed sensitivity from the PIN-FET structure, and electrical AC crosstalk. For each element of the array, the diameter of the photodetective area is 80 $\mu$m, the diameter of the p-metal pad is 90 $\mu$m, and the photodiode seperation is 250 $\mu$m to use Si v-groove. Ground conductor line is placed around diodes and p-metal pads are formed in zigzag to reduce Ac capacitance coupling between array elements. The dark current (IS1dT) is I nA and the capacitance(CS1pDT) is 0.9 pF at -5 V. No signifcant variations of IS1dT and CPD from element to element in the array were observed. We calulated the coupling efficiency for 10/125 SMF and 50/125 GI MMF, and measured the responsivity of the PD array at the wavelength is 1.55 $\mu$ m. Responsivities are 0.93 A/W for SMF and 0.96 A/W for MMF. The optical fiber-PD array module is useful in numerous high speed digital and analog photonic system applications.

  • PDF

접지전류 분류계수 및 전위강하곡선법을 이용한 운전 중인 변전소의 접지저항 측정 방법에 관한 연구 (A Study on Grounding Resistance Measurement of Power Supplying Substation using Grounding Current Division Factor and FOP Profile Method)

  • 안용호;최종기;김용학;한정열;이유진;한병성
    • 조명전기설비학회논문지
    • /
    • 제25권6호
    • /
    • pp.100-107
    • /
    • 2011
  • Since transmission and distribution neutral wires are connected with a substation grounding grid, it is very difficult to measure grounding resistance of isolated substation grounding grid after the substation is energized. It is impractical to isolate the grounding grid from other parallel connections such as distribution line neutrals and overhead ground wires for grounding resistance measurement only. In this paper, we proposed and demonstrated a novel measurement method of grounding resistance of isolated substation grounding grid. For this method, grounding current division factor and conventional FOP(Fall-Of-Potential) profiles were measured at power supplying 154[kV] substation. The obtained FOP profile was processed with the measured grounding current division factor to produce the grounding resistance of isolated grounding grid. Simulated FOP profile agreed well with the measured one showing the validity of the proposed method.

수평 병렬형 풍력 발전기의 요각 및 MPPT 제어 (MPPT and Yawing Control of a New Horizontal-Axis Wind Turbine with Two Parallel-Connected Generators)

  • 이국선;최익;조황;백주훈
    • 한국전자통신학회논문지
    • /
    • 제7권1호
    • /
    • pp.81-89
    • /
    • 2012
  • 범용적으로 사용되고 있는 수평형 풍력 터빈(HAWT)은 블레이드가 장착된 터빈이 회전부인 너셀에 고정되어 타워의 최상단에 지지되는 구조이다. 터빈에서 생산되는 전력은 너셀 내부에서 증속기를 통하여 발전기로 들어가게 된다. 발전기에서 생산되는 전력은 타워를 통해서 지상과 송전선으로 연결되므로 너셀의 요잉이 발생하는 경우 송전선의 꼬임이 발생하게 된다. 따라서 이를 방지하기 위한 슬립링이나 추가적인 요잉 제어 알고리즘이 필요한 단점이 있다. 제안하는 새로운 구조의 HAWT는 베벨기어와 중공축을 이용하여 송전선 문제를 해결하였다. 또한, 병렬로 접속된 두개의 발전기를 이용하여 요잉이 용이할 뿐 아니라 생산 전력을 분산시킴으로써 인버터의 용량을 줄일 수 있다. MPPT 알고리즘과 요잉 제어를 수행하는 시뮬레이션을 통해서 제안하는 구조가 풍력 발전에 효과적임을 보였다.

도로터널에서 적정한 필라폭 산정에 관한 연구 (Study on Determination of Proper Pillar Width in Road Tunnel Design Stage)

  • 양태선;김제경
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제14권5호
    • /
    • pp.187-194
    • /
    • 2010
  • 산악터널과 달리 도심지 지하도로는 대부분 평야지대에 위치하고 충적층이 두껍게 분포하고 있으며 특히 터널 입 출구부는 병렬터널로 분기되는 지점인 동시에 하향굴착을 하는 관계로 터널 시 종점의 위치선정에 따라 공사비에 미치는 영향이 매우 크게 된다. 또한 병렬터널의 필라폭(PW)은 지하 보상비와 직결되기 때문에 병렬터널의 안정을 확보하면서 동시에 최소의 필라폭(PW)으로 터널을 계획하여야 한다. 국내 도로터널의 필라폭(PW)은 일반적으로 1.5D(D: 터널 최대폭)를 기준으로 하며 일부 터널의 경우 입 출구부 극히 한정된 구간에서만 1.5D(D : 터널 최대폭)이내의 필라폭을 적용한 사례가 있으나 보상비 문제가 아닌 선형계획측면에서 불가피하게 발생한 사례들이다. 본 논문은 NATM형식으로서 국내최초 도심지 지하도로 설계사례를 통해 선형 계획단계에서부터 지하 보상비 및 지반특성을 함께 고려하여 적정 필라폭을 설계한 사례를 소개하고 도심지 병렬터널의 적정 필라폭 결정방법에 대해 기술하였다. 적정 필라폭 결정은 설계 및 시공사례 분석과 수치해석을 통한 강도 감소법과 강도/응력비 방법을 이용하였으며 터널간 초근접으로 인해 필라의 안정성이 불량한 터널 입 출구부는 안정성 확보를 위한 보강방법을 제시하고 수치해석을 통해 안정성을 확인하였다.

Wind velocity field during thunderstorms

  • Ponte, Jacinto Jr.;Riera, Jorge D.
    • Wind and Structures
    • /
    • 제10권3호
    • /
    • pp.287-300
    • /
    • 2007
  • Wind action is a factor of fundamental importance in the structural design of light or slender constructions. Codes for structural design usually assume that the incident mean wind velocity is parallel to the ground, which constitutes a valid simplification for frequent winds caused by meteorological phenomena such as Extratropical Storms (EPS) or Tropical Storms. Wind effects due to other phenomena, such as thunderstorms, and its combination with EPS winds in so-called squall lines, are simply neglected. In this paper a model that describes the three-dimensional wind velocity field originated from a downburst in a thunderstorm (TS) is proposed. The model is based on a semi empirical representation of an axially-symmetrical flow line pattern that describes a stationary field, modulated by a function that accounts for the evolution of the wind velocity with time. The model allows the generation of a spatially and temporally variable velocity field, which also includes a fluctuating component of the velocity. All parameters employed in the model are related to meteorological variables, which are susceptible of statistical assessment. A background wind is also considered, in order to account for the translational velocity of the thunderstorm, normally due to local wind conditions. When the translation of the TS is caused by an EPS, a squall line is produced, causing the highest wind velocities associated with TS events. The resulting vertical velocity profiles were also studied and compared with existing models, such as the profiles proposed by Vicroy, et al. (1992) and Wood and Kwok (1998). The present model predicts horizontal velocity profiles that depend on the distance to the storm center, effect not considered by previous models, although the various proposals are globally compatible. The model can be applied in any region of interest, once the relevant meteorological variables are known, to simulate the excitation due to TS winds in the design of transmission lines, long-span crossings, cable-stayed bridges, towers or similar structures.

한국(韓國) 선상지(扇狀地) 연구(硏究) (The Study of Alluvial Fans in Korea)

  • 박노식
    • 동굴
    • /
    • 제68호
    • /
    • pp.5-22
    • /
    • 2005
  • Since earlier in 1947 the writer had been devoting part of his time to study alluvial fans in Korea based on his own interest in geomorphology. However, it was in 1958 when a new geography department was set up and the Research Center of National Lands was established in the university of Kyung Hee, the writer started scientific investigation for alluvial fans. The Following alluvial fans have been studied by the writer: those of Mt. Kwanak and Mt. Chungge in 1947; those of Pulkuksa in 1948; those of Suhnamsa, Suh Myun, Pusan in 1950; those of Shindonae, Mt. Kerrong, in summer of 1958; those of Hwaomsa, Kure and Yongsan Myun, Changhung, in winter of 1958. The article is the comparative study of the above mentioned alluvial fans including Suhkwangsa Fan, Chugaryng Rift Valley. Of course this is not the study covering all af alluvial fans in Korea. Within the limits of his surbey, the writer has com to a conclusion which may be helpful for the Korean alluvial fm study. 1. Korean alluvial fans are generally found in rift valleys or basins. 2. They are formed in places of below 220-meter contour line. 3. The slope from fna apex to river valley is 20-40 degree. The slope of fan surface is 5-20 degree, but most of them under 16 degree. A sudden change of slope is taken place or the fan apex and fan center. 4. Hills (100-200m) are developed on the surfaces of alluvial fans. 5. Most of rivers in alluvial fans are geyser rivers. 6. The depth of well : from ground surface to the well water surface is 4-8 m; water depth is 1-2m. 7. Land utilization; cultivated land 30%: non cultivatedland 70%. The area occupied by upland fields is twice of paddy field area. 8. Settlement : agglomerated settlement is developed on the top or the end of fan and surrounded by windbreakers. 9. Farming pattern at the top of fan fields are rectangular and parallel to flumes but at the center of fan, they are irregular and perpendicular to flumes.