A Reassessment for Dynamic Line Rating of Aged Overhead Transmission Lines in Kepco's Network (한국전력 노후 가공송전선의 동적송전용량에 대한 재평가)

  • Kim, Sung-Duck
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.10
    • /
    • pp.123-129
    • /
    • 2010
  • During the past 2 decades, many electric power companies have been searching various solutions in order to supply power with economical and more efficiency in the present transmission utilities. Most interesting method to increase the line capacity of overhead transmission lines without constructing any new line might be to adapt Dynamic Line Rating(DLR). Specified rating is normally determined by any current level, not by conductor temperature. Although specified rating is essential to design transmission line, dip may be the most important factor in limiting transmission capacity. Transmission lines built by the oldest dip criterion among the 3 different design criteria for conductor dip are nearly over one-half of all Kepco's transmission lines. This paper describes an up-rating method for those transmission lines in order to apply DLR technique. Based on limit dip conductor temperature and current of the transmission lines, limitation performance and effectiveness in applying DLR with weather model are analyzed. As a result of analysis, it can be shown that an improved method could be effectively used for increasing the line rating of old transmission line which was built by the design criterion with low dip margin.

Power Factor Correction Technique of Boost Converter Based on Averaged Model (평균화 모델을 이용한 역률개선 제어기법)

  • 정영석;문건우;이준영;윤명중
    • Proceedings of the KIPE Conference
    • /
    • 1996.06a
    • /
    • pp.85-88
    • /
    • 1996
  • New power factor correction(PFC) technique based on the averaged model of boost converter is proposed. Without measurement of input current, power factor correction scheme derived from the averaged model is presented. With the measurements of input voltage and output voltage, the control signal is generated to make the shape of the line current same as the input voltage. The characteristics of input line current distortion is analyzed by considering the generation of duty cycle.

  • PDF

Fault Location Algorithm for Parallel Transmission Line with a Teed Circuit (병행 2회선의 T분기 선로 고장점 표정 알고리즘)

  • Kwon, Young-Jin;Kang, Sang-Hee;Lee, Seeng-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.49-51
    • /
    • 2000
  • This paper presents a fault location algorithm for single-phase-to-ground faults on the teed circuit of a parallel transmission line. This algorithm uses only local end voltage and current information. Remote end and fault currents are calculated by using distribution factors. To reduce load current effect, negative sequence current is used. EMTP simulation result have shown effectiveness of the algorithm under various conditions.

  • PDF

Compensation of the rotor time constant of induction motor using current error feedback (전류오차 궤환을 이용한 유도전동기 회전자 시정수 보상)

  • 김승민;이무영;권우현
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.195-198
    • /
    • 1997
  • This paper proposes the effective compensation method of the rotor time constant of induction motor. An indirect vector control method is highly dependent on the motor parameters. To solve the problem of performance degradation due to parameter variation in an indirect vector control of induction motor, we compensate the rotor time constant by current error feedback. The proposed method is a simple on-line rotor time constant compensation method using the information from terminal voltages and currents. As the current error, difference between current command and estimated current, approaches to zero, the value of rotor time constant in an indirect vector controller follows the real value of induction motor. This scheme is valid transient region as well as steady state region regardless of low or high speed. This method is verified by computer simulation. For this, we constructed the simulation model of induction motor, indirect vector controller and current regulated PWM (CRPWM) voltage source inverter (VSI) using SIMULINK in MATLAB.

  • PDF

A Study on the Numerical Models of Wave induced Currents (파랑에 의한 연안류의 수치모델에 관한 연구)

  • Lee, Jung-Maan;Kim, Jae-Joong;Park, Jung-Chul
    • Journal of Ocean Engineering and Technology
    • /
    • v.12 no.3 s.29
    • /
    • pp.75-85
    • /
    • 1998
  • A finite difference model for predicting time-dependent, wave-induced nearshore current is studied. The model includes wave refraction, wave-current interaction, bottom friction and wind effect. This model iteratively solved the linear the linear set of conservation of both mass and momentum, which were time averaged (over one wave period) and depth integrated, for mean velocities and free surface displacement. Numerical simulations of nearshore current under oblique wave attack, and for wave and wind induced current on a longshore periodic beach are carried out. Longshore velocities tend to zero in some distances outside the breaker line. And the peak velocity is shifted shoreward at the breaker line. The results represent the general characteristics of the nearshore current induced by wave.

  • PDF

Improvement of One-Cycle Controller Response with a Current Mode Controller

  • Ruzbehani, Mohsen;Zhou, Luowei;Mirzaei, Nasser
    • Journal of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.21-26
    • /
    • 2010
  • The most important feature of the one-cycle control method is its excellent ability in line disturbance rejection. However, when it is used as a controller in dc-dc converters, it has an undesirable transient response. The voltage overshoot at the transient time, which usually exists in one-cycle controlled converters, is unwanted in many applications and it is sometimes hazardous. In this paper, it is shown that the combination of a one-cycle controller with a current mode controller, can improve the transient response and consequently the overshoot can be controlled. Therefore, the combined controller has the excellent line disturbance rejection of a one-cycle controller and the output current limiting capability of current mode controllers. Because in this scheme a one-cycle controller is the master controller, the problem of instability of current mode control, will not happen. By simulation and a practical prototype, the capability of the method is shown.

Neutral Current Calculation of Pole-Top Overhead Distribution Line (가공 배전선로 장주의 중성선 전류 계산)

  • Seo, Hun-Chul;Kwon, O-Sang;Kim, Chul-Hwan;Jung, Chang-Soo;Yoo, Yeon-Pyo
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.7
    • /
    • pp.290-296
    • /
    • 2006
  • If the three phases are not balanced, the current in neutral wire is not zero. Then, the induced voltage can be generated in communication line. The KEPCO's rule about unbalanced current for one step type in distribution pole is a twenty percent of phase current. But the unbalanced current for two step type in distribution pole can't decide the rule because there are many different views. This paper presents the calculation and analysis technique of neutral current in distribution poles using equivalent circuit analysis and EMTP simulation.

Operational Characteristics of Transformer-Type SFCL with or without Neutral Line between the Secondary windings and Superconducting units (2차 권선과 초전도 사이의 중성선 유무에 따른 변압기형 초전도 한류기의 동작특성)

  • Cho, Yong-Sun;Choi, Hyo-Sang;Go, Sung-Pil
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1268-1273
    • /
    • 2011
  • The study on power capacity increase of superconducting fault current limiter (SFCL) is one of the most important researches to apply a SFCL in the power system. To achieve this, we thought that the unbalanced quenching problem generated in series connection of superconducting units should be solved. In this paper, we investigated the quenching characteristics of superconducting units in the transformer-type SFCL with or without the neutral line between secondary windings and superconducting units. In case of transformer-type SFCL without neutral line, the connection structure of superconducting units is identical to that of the resistive-type SFCL connected in series. Therefore, the unbalanced quenching was occurred by difference of critical current between superconducting units. However, in case of transformer-type SFCL with neutral line, the superconducting units with different critical current were simultaneously quenched. It was because the currents induced by secondary winding were separately flowed through the superconducting units. By these results, we confirmed that the resistances and consumption powers of the superconducting units were equally generated.

Study of the Applicability of the Carson Line Model for the Series Reactance Calculation of the Power Feeding Lines with no Ground Return (전송로의 직렬리앤턴스 산정 시 Carson 모델의 적용범위 검토)

  • Chung, Sang-Gi;Kwon, Sam-Young;Chang, Sang-Hoon;Jang, Dong-Uk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.2
    • /
    • pp.225-231
    • /
    • 2009
  • In this paper, it is shown that Carson's equation can still be applied for the calculation of the series reactance of transmission lines with no ground return current as well as the one with ground return. It is proved in the following method. First two voltage drop equations for three-phase three wire transmission line are derived, one without considering ground return and the other using Carson's equation. The impedance matrix of the two equations are different from each other. But if we put the condition of zero ground current, $I_a+I_b+I_c=0$, those two equations becomes the identical equations. Therefore even a transmission line is not grounded, its line parameters can still be obtained using the Carson's equation. It has been confused whether or not Carson's equation can be used for an ungrounded system. It is because where ever Carson's equation is shown in the book, it also says that the system has ground return current paths as a premise. It is also verified with EMTP studies on the test circuit.

Uniformity of $YBa_2$$Cu_3$$O_7$ Step-edge Josephson Junctions (Y$Ba_2$$Cu_3$$O_7$ 모서리 죠셉슨 접합의 균일성)

  • Lee, S.G.;Hwang, Y.;Kim, J.T.
    • Progress in Superconductivity
    • /
    • v.2 no.2
    • /
    • pp.81-85
    • /
    • 2001
  • Uniformity of critical currents of YBa$_2$Cu$_3$O$_{7}$ step-edge Josephson junctions on SrTiO$_3$(100) substrates have been studied at various step-line angles. 15 identical junctions were made in series on each substrate that has a long straight step-edge line. Step-line angles studied were 0$^{\circ}$, 15$^{\circ}$, 30$^{\circ}$, and 45$^{\circ}$with respect to the crystal major axes of the substrate. Scattering of junction critical currents among the junctions on the same substrate increased with the step-line angle. Current-voltage curves showed standard resistively-shunted-junction (RSJ) characteristics in most of the 0$^{\circ}$junctions. However, the number of junctions showing RSJ behavior decreased with increasing step-line angle. Variations of detailed microstructure of the step-edge among junctions, which are coupled with the d-wave symmetry of YBa$_2$Cu$_3$O$_{7}$, are believed to be the main cause for the nonuniformity in the critical current.ent.