• Title/Summary/Keyword: Linac-based Radiosurgery

Search Result 36, Processing Time 0.03 seconds

Radiation Dose of Lens and Thyroid in Linac-based Radiosurgery in Humanoid Phantom (선형가속기형 방사선수술시 인형 팬텀에서 수정체 및 갑상선 선량)

  • Kim, Dae-Yong;Kim, Il-Han
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.517-529
    • /
    • 1998
  • Purpose : Although many studies have investigated the dosimetric aspects of stereotactic radiosurgery in terms of target volume, the absorbed doses at extracranial sites: especially the lens or thyroid - which are sensitive to radiation for deterministic or stochastic effect -have infrequently been reported. The aim of this study is to evaluate what effects the parameters of radiosurgery have on the absorbed doses of the lens and thyroid in patients treated by stereotactic radiosurgery, using a systematic plan in a humanoid phantom. Materials and Methods : Six isocenters were selected and radiosurgery was planned using the stereotactic radiosurgery system which the Department of Therapeutic Radiology at Seoul National University College of Medicine developed. The experimental radiosurgery plan consisted of 6 arc planes per one isocenter, 100 degrees for each arc range and an accessory collimator diameter size of 2 cm. After 250 cGy of irradiation from each arc, the doses absorbed at the lens and thyroid were measured by thermoluminescence dosimetry. Results : The lens dose was 0.23$\pm$0.08$\%$ of the maximum dose for each isocenter when the exit beam did not pass through the lens and was 0.76$\pm$0.12$\%$ of the maximum dose for each isocenter when the exit beam passed through the lens. The thyroid dose was 0.18$\pm$0.05$\%$ of the maximum dose for each isocenter when the exit beam did not pass through the thyroid and was 0.41$\pm$0.04$\%$ of the maximum dose for each isocenter when the exit beam Passed through the thyroid. The passing of the exit beam is the most significant factor of organ dose and the absorbed dose by an arc crossing organ decides 80$\%$ of the total dose. The absorbed doses of the lens and thyroid were larger as the isocenter sites and arc planes were closer to each organ. There were no differences in the doses at the surface and 5 mm depth from the surface in the eyelid and thyroid areas. Conclusion : As the isocenter and arc plane were placed closer to the lens and thyroid, the doses increased. Whether the exit beams passed through the lens or thyroid greatly influenced the lens and thyroid dose. The surface dose of the lens and thyroid consistently represent the tissue dose. Even when the exit beam passes through the lens and thyroid, the doses are less than 1$\%$ of the maximum dose and therefore, are too low to evoke late complications, but nevertheless, we should try to minimize the thyroid dose in children, whenever possible.

  • PDF

Commissioning of a micro-MLC (mMLC) for Stereotactic Radiosurgery (방사선수술용 4뱅크 마이크로 다엽콜리메이터의 인수 검사)

  • Jeong, Dong-Hyeok;Shin, Kyo-Chul;Kim, Jeung-Kee;Kim, Soo-Kon;Moon, Sun-Rock;Lee, Kang-Kyoo
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.43-50
    • /
    • 2009
  • The 4 bank mico-MLC (mMLC; Acculeaf, Direx, Isral) has been commissioned for clinical use of linac based stereotactic radiosurgery. The geometrical parameters to control the leaves were determined and comparisons between measured and calculated by the calculation model were performed in terms of absolute dose (cGy/100 MU). As a result of evaluating calculated dose for various field sizes and depths of 5 and 10 cm in water in the geometric condition of fixed SSD (source to surface distance) and fixed SCD (source to chamber distance), most of differences were within 1% for 6 MV and 15 MV x-rays. The penumbral widths at the isocenter were approximately evaluated to 0.29~0.43 cm depending on the field size for 6 MV and 0.36~0.51 cm for 15 MV x-rays. The average transmission and leakage for 6 MV and 15 MV x-rays were 6.6% and 7.4% respectively in single level of leaves fully closed. In case of dual level of leaves fully closed the measured transmission is approximately 0.5% for both 6 MV and 15 MV x-rays. Through the commissiong procedure we could verify the dose characteristics of mMLC and approximately evaluate the error ranges for treatment planning system.

  • PDF

LINAC-based Stereotactic Radiosurgery for Meningiomas (수막종에 대한 선형가속기형 정위방사선수술)

  • Shin Seong Soo;Kim Dae Yong;Ahn Yong Chan;Lee Jung Il;Nam Do-Hyun;Lim Do Hoon;Huh Seung Jae;Yeo Inhwan J;Shin Hyung Jin;Park Kwan;Kim BoKyoung;Kim Jong Hyun
    • Radiation Oncology Journal
    • /
    • v.19 no.2
    • /
    • pp.87-94
    • /
    • 2001
  • Purpose : To evaluate the role of LINAC-based stereotactic radiosurgery (SRS) in the management of meningiomas, we reviewed clinical response, image response, neurological deficits for patients treated at our institution. Methods and materials : Between February 1995 and December 1999, twenty-six patients were treated with SRS. Seven patients had undergone prior resection. Nineteen patients received SRS as the initial treatment. There were 7 male and 19 female patients. The median age was 51 years (range, $14\~67\;years$). At least one clinical symptom presented at the time of SRS in 17 patients and cranial neuropathy was seen in 7 patients. The median tumor volume was $4.7\;cm^3\;(range,\;0.7\~16.5\;m^3)$. The mean marginal dose was 15 Gy (range, $10\~20\;Gy$), delivered to the $80\%$ isodose surface (range, $46\~90\%$). The median clinical and imaging follow-up periods were 27 months (range, 1-71 months) and 25 months (range, $1\~52\;months$), respectively. Results : Of 14 patients who had clinical follow-up of one year or longer, thirteen patients $(93\%)$ were improved clinically at follow-up examination. Clinical symptom worsened in one patient at 4 months after SRS as a result of intratumoral edema, who underwent surgical resection at 7 months. OF 14 patients who had radiologic follow-up of one year or longer, tumor volume decreased in 7 patients $(50\%)$ at a median of 11 months (range, $6\~25\;months$), remained stable in 6 patients $(43\%)$, and increased in one patient $(7\%)$, who underwent surgical resection at 44 months. New radiation-induced neurological deficits developed in six patients $(23\%)$. Five patients $(19\%)$ had transient neurological deficits, completely resolved by conservative treatment including steroid therapy. Radiation-induced brain necrosis developed in one patient $(3.8\%)$ at 9 months after SRS who followed by surgical resection of tumor and necrotic tissue. Conclusions : LINAC-based SRS proves to be an effective and safe management strategy for small to moderate sized meningiomas, inoperable, residual, and recurrent, but long-term follow-up will be necessary to fully evaluate its efficacy. To reduce the radiation-induced neurological deficit for large size meningioma and/or in the proximity of critical and neural structure, more delicate treatment planning and optimal decision of radiation dose will be necessary.

  • PDF

Advances in Radiation Oncology in New Millennium in Korea (21세기 방사선종양학의 전망:최근의 진보와 한국에서의 발전)

  • Huh, Seung-Jae;Park, Chan-Il
    • Radiation Oncology Journal
    • /
    • v.18 no.3
    • /
    • pp.167-176
    • /
    • 2000
  • The objective of recent radiation therapy is to improve the quality of treatment and the after treatment quality of life. In Korea, sharing the same objective, significant advancement was made due to the gradual increase of patient number and rapid increase of treatment facilities. The advancement includes generalization of three-dimensional conformal radiotherapy (3D-CRT), application of linac-based stereotactic radiosurgery (SRS), and furthermore, the introduction of intensity modulated radiation therapy (IMRT). Authors in this paper prospectively review the followings: the advancement of radiation oncology in Korea, the recent status of four-dimensional radiation therapy, IMRT, the concept of the treatment with biological conformity, the trend of combined chemoradiotherapy, the importance of internet and radiation oncology information management system as influenced by the revolution of information technology, and finally the global trend of telemedicine in radiation oncology. Additionally, we suggest the methods to improve radiotherapy treatment, which include improvement of quality assurance (QA) measures by developing Koreanized QA protocol and system, regional study about clinical protocol development for phase three clinical trial, suggestion of unified treatment protocol and guideline by academic or research societies, domestic generation of treatment equipment's or system, establishment of nationwide data base of radiation-oncology-related information, and finally patterns-of-care study about major cancers.

  • PDF

GafChromic Film Dosimetry for Stereotactic Radiosurgery with a Linear Accelerator (선형가속기를 이용한 정위방사선 치료 시 GafChromic Film을 이용한 선량측정)

  • Han Seung Hee;Cho Byung Chul;Park Suk Won;Oh Do Hoon;Park Hee Chul;Bae Hoon Sik
    • Radiation Oncology Journal
    • /
    • v.21 no.2
    • /
    • pp.167-173
    • /
    • 2003
  • Purpose: The purpose of this study was to evaluate whether a GafChromic film applied to stereotactic radiosurgery with a linear accelerator could provide information on the value for acceptance testing and quality control on the absolute dose and relative dose measurements and/or calculation of treatment planning system. Materials and methods: A spherical acrylic phantom, simulating a patient's head, was constructed from three points. The absolute and relative dose distributions could be measured by inserting a GafChromic film into the phantom. We tested the use of a calibrated GafChromic film (MD-55-2, Nuclear Associate, USA) for measuring the optical density. These measurements were achieved by irradiating the films with a dose of 0-112 Gy employing 6 MV photon. To verify the accuracy of the prescribed dose delivery to a target isocenter using a five arc beams (irradiated in 3 Gy per one beam) setup, calculated by the Linapel planning system the absolute dose and relative dose distribution using a GafChromic film were measured. All the irradiated films were digitized with a Lumiscan 75 laser digitizer and processed with the RIT113 film dosimetry system. Results: We verified the linearity of the Optical Density of a MD-55-2 GafChromic film, and measured the depth dose profile of the beam. The absolute dose delivered to the target was close to the prescribed dose of Linapel within an accuracy for the GafChromic film dosimetry (of $\pm$3$\%$), with a measurement uncertainty of $\pm$1 mm for the 50$\~$90$\%$ isodose lines. Conclusion: Our results have shown that the absolute dose and relative dose distribution curves obtained from a GafChromic film can provide information on the value for acceptance. To conclude the GafChromic flim is a convenient and useful dosimetry tool for linac based radiosurgery.

Clinical Experience of LINAC-based Stereotactic Radiosurgery for Angiographically Occult Vascular Malformations (혈관조영상 잠재혈관기형에 대한 선형가속기형 정위방사선수술의 임상경험)

  • Kim Dae Yong;Ahn Yong Chan;Lee Jung Il;Nam Do-Hyun;Lim Do Hoon;Lee Jeong Eun;Yeo Inhwan;Huh Seung Jae;Noh Young Joo;Shin Seong Soo;Hong Seung-Chyul;Kim Jong Hyun
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.1-9
    • /
    • 2001
  • Purpose : To establish the role of stereotactic radiosurgery (SRS) for the treatment of patients with angiographically occult vascular malformation (AOVM). Materials and Methods : Eleven patients (12 lesions) with AOVM were treated with linear accelerator-based SRS between February 1995 and December 1999. A magnetic resonance imaging of each patients showed well-circumscribed vascular lesion with reticulated core of heterogeneous signal intensity and peripheral rim of low signal intensity. SRS were peformed with the median peripheral dose of 16 Gy (range 13~25). A single isocenter was used with median collimator size of 14 mm (range 8~20) diameter. Results : With a median follow-up period of 42 months (range 12~56), rebleeding occurred in 3 AOVMS at 5, 6 and 12 months after SRS but no further bleeding did. Two patients experienced radiation-induced necrosis associated with permanent neurologic deficit and one patient showed transient edema of increased 72 signal intensity. Conclusion : SRS may be effective for the prevention of rebleeding in AOVM located in surgically inaccessible region of the brain. Careful consideration should be needed in the decision of case selection and dose prescription because the incidence of radiation-induced complications is too high to be accepted.

  • PDF