• 제목/요약/키워드: Limit of emission power

검색결과 58건 처리시간 0.024초

선형부하가 고려된 고조파 전류 특성 및 방출값 평가 (A Study on the Harmonic Current Characteristic and Emission Value Assess Method Considering the Linear Load)

  • 박용업;최성훈;장준수
    • 전기학회논문지
    • /
    • 제59권1호
    • /
    • pp.33-39
    • /
    • 2010
  • In order to operate the power system satisfactory for both system operators and customers, it is important to limit the harmonic currents to the allowable levels which injected into the system from the distorting installations. In this regard, the principles for the allocation of emission limits on individual customer were introduced in the technical report of IEC61000-3-6. According to these general principles, the emission limits are dependent on the agreed power of the customer, the power of the harmonic-generating equipment, and the system characteristics. The considerations in this report are very comprehensive and the process introduced is practical enough to implement as it is. However, there is a fact not appropriately dealing in the report that could be a very tickle but has a huge impact on determining the emission limit. This is the effect of non-harmonic load currents. More precisely, these are from the equipments which do not emit any harmonic or may emit harmonics but this specific order under the consideration by themselves if the source power is sinusoidal. The load currents originated from these equipments have an effect of active filter against the specific order of harmonic therefore, these should be dealt as a significant factoron the process of determining the emission limits for individual customer.

지역별 CO2 배출량규제를 고려한 발전소 최적운전 알고리즘의 개발 (Development of algorism to optimal operation of Power Generation considering Regional Regulation of CO2 Emission)

  • 김용하;김영길;이평호;조현미;우성민
    • 전기학회논문지
    • /
    • 제59권11호
    • /
    • pp.1936-1941
    • /
    • 2010
  • This purpose of this paper is to propose a methodology for optimal generating operation in power system to minimize the cost of generation subject to not only system constraints but also regional $CO_2$ emission constraints. To solve this ELD problem calculated range limit on minimum and maximum power outputs by regional Equal Generator how each regional capacity is connected into one and expressed Equal Fuel Cost Function considering regional $CO_2$ emission constraints. Accordingly, being modified regional load, new power outputs considering regional $CO_2$ emission constraints were calculated by ELD. The proposed model for evaluating availability is tested on IEEE RTS(Reliability Test System)-24 in detail.

Opposition Based Differential Evolution Algorithm for Dynamic Economic Emission Load Dispatch (EELD) with Emission Constraints and Valve Point Effects

  • Thenmalar, K.;Ramesh, S.;Thiruvenkadam, S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.1508-1517
    • /
    • 2015
  • Optimal Power dispatch is the short-term decision of the optimal output of a number of power generation facilities, to meet the system demand, with the objective of Power dispatching at the lowest possible cost, subject to transmission lines power loss and operational constraints. The operational constraint includes power balance constraint, generator limit constraint, and emission dispatch constraint and valve point effects. In this paper, Opposition based Differential Evolution Algorithm (ODEA) has been proposed to handle the objective function and the operational constraints simultaneously. Furthermore, the valve point loading effects and transmission lines power loss are also considered for the efficient and effective Power dispatch. The ODEA has unique features such as self tuning of its control parameters, self acceleration and migration for searching. As a result, it requires very minimum executions compared with other searching strategies. The effectiveness of the algorithm has been validated through four standard test cases and compared with previous studies. The proposed method out performs the previous methods.

An Investigation Into the Impact of Limiting Carbon Emissions on the Korean Power System and the Electricity Market

  • Kim, Changseob;Park, Hyeongon
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권3호
    • /
    • pp.1038-1045
    • /
    • 2017
  • To address mounting concerns over global warming, the Paris Agreement was reached in December 2015, which aims to limit the increase in global average temperature. South Korea has set a highly ambitious target to reduce emissions and submitted an Intended Nationally Determined Contribution (INDC). Based on the INDC, we investigated the impact of limiting carbon emissions on the power system and the electricity market in Korea. Through detailed simulations on assumed plausible scenarios, this work highlights a) the effects of different carbon emission targets on the annual carbon emission volumes, generation costs, and carbon price; b) the generation mix changes induced by carbon emission limits; and c) the difference in system marginal price and payments for generator owners that carbon emission constraint creates in electricity markets under three different pricing rules.

영광 원자력 발전소 주변 환경 방사능 측정에 관한 연구 (The study on Measuring of Environmental Radioactivity in the Vicinity of Yonggwang Nuclear Power Plant)

  • 박종섭
    • 자원환경지질
    • /
    • 제32권3호
    • /
    • pp.273-280
    • /
    • 1999
  • In order to protect inhabitans' health and to collect data for prediction of the effcts from accidental emission of rasioactive materials from nuclear power plant, exposed dose rate be monitored within the limit dose rate. This research was carried out to investigate the accumulation of environmental radioactivity around Younggwang Nuclear Power Plant, and to infer and in infer and assay the additional exposed dose rate of inhabitants in Younggwang site from the operation of nuclear plant operation. External radiation dose rate, radiation environmental samples, and exposed dose rate of inhabitants in Younggwang site were investigated for estimaing environment activity in the vicinity of the nuclear power plant area. For the external radiation dose rate, the result showed that range of normal variation was found and any artificial radioisotope was not deteted in the analysis of environmental samples. Exposed dose rate of inhabitants was lower than 0.4% of the limit value of ICRP and it may be concluded that there was no effect on inhabitants and environment from the operation of nuclear power plant.

  • PDF

Low flow-low power 유도결합 플라즈마 원자방출 분광법에서의 분석적 특성에 관한 연구 (A Study on the Analytical Characterizations of the Low Flow-Low Power ICP-AES)

  • 양혜순;김영만;김선태;최범석
    • 분석과학
    • /
    • 제7권3호
    • /
    • pp.253-260
    • /
    • 1994
  • Low power-low flow 유도결합 플라즈마 원자방출 분광법(ICP-AES)에서 분석적 특성에 대해 연구하였다. Low power ICP에서는 moderate power ICP보다 알짜세기는 감소하지만 바탕세기도 감소하여 알짜세기에 대한 바탕세기의 비는 오히려 증가하였다. Low power ICP에서도 작동조건에 따라 moderate power와 비슷한 검출한계를 얻을 수 있으며, 검량곡선도 $10^4{\sim}10^5$ 정도의 직선성을 가질 수 있었다. 알칼리 금속에 의한 이온화 방해영향은 시료운반기체의 사용량을 증가시킬수록 증가하지만, RF power의 변화에 대해서는 큰 차이가 없었다.

  • PDF

580 MW급 복합발전소 탈질설비에서 가스터빈 출력에 따른 암모니아 소모량 변화 (Change of Ammonia Consumption with Gas Turbine Output in DeNOx System for a 580 MW Combined Cycle Power Plant)

  • 장용우;유호선
    • 플랜트 저널
    • /
    • 제15권3호
    • /
    • pp.23-28
    • /
    • 2019
  • 본 연구에서는 580 MW급 세종복합발전소의 선택적 촉매환원방식 탈질설비 1호기를 대상으로 강화된 대기환경보전법 및 환경평가협의 질소산화물 허용배출기준을 준수하는 암모니아 소모량을 찾고자 가스터빈 출력별 암모니아 투입량을 조절하며 측정하였다. 측정을 위해 가스터빈 출력은 50, 99, 149 그리고 198 MW로 변동시키고 각 출력단계별 연소가스 및 암모니아 공급조건을 고정한 상태에서 탈질설비 내 암모니아 소모량을 조절하였다. 질소산화물 배출기준을 10 ppm에서 8 ppm으로 변경하였을 때 출력대별 암모니아 소모량은 각각 78, 93, 105 그리고 133 kg/h에서 89, 113, 132 그리고 176 kg/h로 증가 되었다. 암모니아 소모량 증가율은 질소산화물 배출기준 10 ppm 대비 출력대 별 각각 14, 22, 26 그리고 32%로 출력이 증가할 수 록 증가율도 늘어남을 알 수 있었다.

탄소세(炭素稅)를 고려한 화력발전 설비간의 경제성 평가 (Economic Analysis of Power Plant Utilities Under $CO_2$ Emission Tax)

  • 김지수;이병남;김태진
    • 산업공학
    • /
    • 제10권1호
    • /
    • pp.237-248
    • /
    • 1997
  • The purpose of this study is to make an economic analysis of power plant utilities by examining electricity generating costs with environmental consideration. Economic growth has caused pollutant emission, and subsequent environmental pollution has been identified as a very real limit to sustainable development. Considering the enormous role of electricity in the national economy, it is thus very important to study the effect of environmental regulations on the electricity sector. Because power utilities need large investments during construction, operation and maintenance, and also require much construction lead time. Economic analysis is the very important process in the electric system expansion planning. In this study, the levelized generation cost method is used in comparing economic analysis of power plant utilities. Among the pollutants discharged of the electricity sector, this study principally deals with the control activities related only to $CO_2$, and $NO_2$, since the control cost of $SO_2$, and TSP (Total Suspended Particulates) is already included in the construction cost of utilities. The cost of electricity generation in a coal-fired power plant is compared with one in an LNG combined cycle power plant. Moreover this study surveys the sensitivity of fuel price, interest rate and carbon tax. In each case, this sensitivity can help to decide which utility is economically justified in the circumstance of environmental regulations.

  • PDF

구조적 제약조건을 갖는 500 MW 석탄화력발전소 탈황설비의 성능개선 (Performance Enhancement of Flue Gas Desulfurization System with Structural Constraints in 500 MW Coal Fired Power Plants)

  • 김종성;유호선
    • 플랜트 저널
    • /
    • 제15권4호
    • /
    • pp.30-35
    • /
    • 2019
  • 미세먼지 감축에 대한 사회적 요구 증가와 강화되는 대기오염물질 배출허용기준을 충족시키기 위해 구조적 제약조건을 갖는 500 MW급 석탄화력발전소 탈황설비의 성능개선 방안을 제시하였다. 탈황설비 흡수탑을 통과하는 배기가스가 선회하도록 내부 설비를 개조하여 난류를 형성시켜 물질전달효율을 증가시키고 반응 면적 및 시간을 증가시킴으로써 황산화물 저감 및 먼지 포집 능력을 향상시킬 수 있었다. 개선결과 황산화물 제거효율은 91.61%에서 98.43%로 향상되었고 먼지 제거성능은 77.4%에서 87.08%로 향상되었다. 배출농도는 황산화물 7.85 ppm, 먼지 4.67 mg/㎥이 배출되어 2023년의 대기오염물질 배출허용기준인 황산화물 25 ppm, 먼지 5 mg/㎥을 만족하는 수준이다. 본 연구의 성능 개선 방식은 유사한 제약조건을 갖는 다른 석탄화력발전소에도 효과적으로 적용될 수 있으리라 기대된다.

전력계통 고조파 유입 유출 분석에 관한 연구 (A Study on the Analysis of Harmonic Injection and Emission for Power System)

  • 왕용필;정종원;김세동;곽노홍;전영수;박상호
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.203-205
    • /
    • 2007
  • A method is proposed in this paper to determine the harmonic contributions of a customer at the point of common coupling. The method can quantify customer and utility responsibilities for limit violations caused by either harmonic source changes or harmonic impedance changes. It can be implemented in current power quality monitors and digital revenue meters. The method is comparison of measurement phase angles between harmonic voltage and current. The proposed method has been applied to the test system. The study results have indicated the accuracy of harmonic injection and emission for customer and utility.

  • PDF