• Title/Summary/Keyword: Limit gauge

Search Result 42, Processing Time 0.031 seconds

Study on wheel profile for railway vehicle with narrow gauge by profile contact analysis (휠-레일 접촉 해석을 통한 협궤용 전동차 차륜 답면 분석)

  • Yang Hun-Suk;Lee Won-Sang;Nam Hak-Gi
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.146-151
    • /
    • 2005
  • Main parameters of wheel-rail combination are investigated by profile analysis. A rolling radius difference is one of the main characteristics that describe a contact between wheelset and railway track, which in turn defines the dynamic behavior of a wheelset. This paper describes functional relation between lateral wheelset displacement and rolling radius difference or conicity on new/worn wheel of existing narrow gauge vehicle. Information about curving behavior and running stability are given by this both relations. The optimal wheel profile for railway vehicle with narrow gauge is adopted through this analysis. And, the applicable limit value of conicity which is used in order to do dynamic simulation of vehicle is presented.

  • PDF

A Study on Development of Structural Health Monitoring System for Steel Beams Using Strain Gauges (변형률계를 이용한 강재보의 건전도 평가 시스템 개발에 관한 연구)

  • Hahn, Hyun Gyu;Ahn, Hyung Joon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.1
    • /
    • pp.99-109
    • /
    • 2012
  • This study aimed to develop a Structural Health Monitoring System for steel beams in the manner of suggesting and verifying a theoretical formula for displacement estimation using strain gauges, and estimating the loading points and magnitude. According to the results of this study, it was found that when a load of 160kN (56% of the yield load) was applied, the error rate of the deflection obtained with a strain gauge at the point of maximum deflection compared to the deflection measured with a displacement meter was within 2%, and that the estimates of the magnitude and points of load application also showed the error rate of not more than 1%. This suggests that the displacement and load of steel beams can be measured with strain gauges and further, it will enable more cost-effective sensor designing without displacement meter or load cell. The Structural Health Monitoring System program implemented in Lab VIEW gave graded warnings whenever the measured data exceeds the specified range (strength limit state, serviceability limit state, yield strain), and both the serviceability limit state and strength limit state could be simultaneously monitored with strain gauge alone.

Diagnosis of Thickness Quality Using Multivariate Statistical Analysis in Hot Finishing Mill

  • Kim, Heung-Mook
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.116.3-116
    • /
    • 2001
  • A diagnosis methodology for thickness quality in hot finishing mill is proposed based on multivariate statistical analysis. The thickness of hot strip is a key quality factor that is measured by x-ray thickness gauge. Currently, the thickness quality is guaranteed by upper and lower limit of thickness deviation from target thickness. But if any over-limit is occurred, there is no in-line method to identify the causes. In this paper, many parameters are extracted from the thickness deviation signal such as mean deviation(top, middle, tail), rms deviation(top, middle, tail) and peak deviation(top, middle, tail) as time domain parameters ...

  • PDF

Comparison of Muscular Endurance Limit of the Thumb with Repetitive Using Between Adults and Children (성인 및 청소년의 엄지손가락 반복사용에 따른 근 피로한계 비교)

  • Park, J.H.;Kim, G.H.;Son, K.
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • According to the frequent use of mobile devices, risk of repetitive strain injury for the finger joints was increasing recently. The purpose of this study was to investigate the difference of muscular endurance limit of the thumb between adults and children. A total of thirty subjects (15 adults: $41.0{\pm}7.9$ years and 15 children: $9.5{\pm}2.7$ years) was recruited for this experiment. Maximum voluntary contraction (MVC) of the thumb was measured for 100 trials for each subject by using a push-pull gauge. From the maximum peak value obtained, three main factors (MVC, endurance limit, and fatigue index) were defined to quantify fatigue characteristics of the thumb flexor muscle. The experimental results showed that the mean of MVC, endurance limit, and fatigue index of the children were approximately 50% compared to the adults (p < 0.001). From the results of Pearson correlation test, the endurance limit was highly correlated with weight, age, hand length rather than height. Based on this study, children are more vulnerable to repetitive task using the thumb such as text/SNS messaging, gaming, and scrolling.

Investigation and Analysis of the Occurrence of Rail Head Checks

  • Jin, Ying;Aoki, Fusayoshi;Ishida, Makoto;Namura, Akira
    • International Journal of Railway
    • /
    • v.2 no.2
    • /
    • pp.43-49
    • /
    • 2009
  • Wear and rolling contact fatigue (RCF) defects are most important causes of rail damage, and often interaction competitive at present railway track. Head check is one of rolling contact fatigue (RCF) defects, and generally occurs in mild circular curves and transition curves that are set at both ends of sharp circular curves. Wear tends to limit the crack growth of head checks by removing the material from the RCF surface. In order to clarify the conditions of the occurrence and growth of head checks, the authors measured the interacting forces between wheels and rails and the angle of attack of wheelset, and carried out contact analyses using the actual profile data of wheels and rails. The effects of the lateral force, the contact geometry, and the wear rate at rail gauge comer on the formation of head checks were also analyzed by using the worn profiles of actual wheels and rails and the data obtained by a track inspection car. Some specific range of wear rate at the gauge comer was identified as having close relation with occurrence of head checks.

  • PDF

Computation of Areal Reduction Factor and Its Regional Variability (면적우량환산계수의 산정과 그 지역적 변화)

  • Kim, Won;Yoon, Kang-Hoon
    • Water for future
    • /
    • v.25 no.3
    • /
    • pp.79-86
    • /
    • 1992
  • ARF(Areal Reduction Factor) have been developed and used to convert point I-D-F to areal I-D-F in many countries. In Korea, through ARF was calculated in Han river basin by several researchers, it has limit to apply to other regions \ulcorner 새 low density of rainfall gauge station and shortage of data. In this study ARF has developed in areas of high density of rainfall gauge station, Pyungchang river(han river), Wi stream(nakdong river), and Bochung stream(Guem river) basin by fixed-area method. And coefficient of variation of annual mean precipitation was presented to use ARF in othere areas and its applicability was analyzed.

  • PDF

Assessment of sediment profiles applying nuclear techniques: use of a nucleonic gauge in Panama Canal watershed

  • Xavier Sanchez;Henry Hoo;Patrick Brisset;Reinhardt Pinzon
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4236-4243
    • /
    • 2022
  • An industrial nuclear technique based on the use of an X-ray profiler was implemented to estimate the densities or concentrations of sediments present in an Atlantic maritime zone in the areas subjected to dredging under the governance of the Panama Canal Authority (ACP). The sediment profiles show in most areas there is a concentration of between 1.00-1.15 g/cm3 except for one area in particular, the density starts at 1.20 g/cm3 and even reaches values greater than 1.50 g/cm3; therefore, an already consolidated sediment is present, which, depending on the depth found. Values of 1.265 g/cm3, 1.297 g/cm3, 1.185 g/cm3 obtained by ACP previous studies are within the range of 1.20-1.30 g/cm3 measured with the nucleonic gauge. However, it should be noted that during the tests with the X ray profiler, sediment densities values greater than the aforementioned limit were also obtained that varying according at depths close to 12 m and 18 m with values reached up to 1.513 g/cm3 and 1.60 g/cm3, respectively. This demonstrates that sediment accumulation depends on depth. This nucleonic gauge is feasible technique for the study of the sedimentation phenomenon in channel basins and even in other projects nationwide.

A Study of Limit State Design Method in Soil Slope (토사면의 한계상태 설계법에 관한 연구)

  • Joung, Gi-Hun;Kim, Jong-Min;Jang, Bum-Su
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.129-136
    • /
    • 2005
  • The deterministic analysis method has generally used to evaluate the slope stability and it evaluates the slope stability with decision value that is a representative value of design variables. However, one of disadvantages in the deterministic approach is there is not able to consider the uncertainty of soil strength properties, even though it is the biggest influential parameter of the slope stability. On the other hand, the limit state design(LSD) can take a consideration of uncertainties and computes both the reliability index and the probability of failure. LSD method is capable of overcoming the disadvantages of deterministic method and evaluating the slope stability more reliably. In this study, both the mean value and standard deviation of the internal land's representative soil strength properties applied to process the LSD method. The major purpose of this study is to gauge the general applicability of the limit state design in soil slope and to weigh the comparative validity of the proposed partial safety factor. In order to reach the aim of this study, the partial safety factor and resistance factor which totally satisfied the slope's overall safety factor were calculated by the load and resistance safety factor design (LRFD).

  • PDF

Stainless-steel sxtreme high vacuum system with a new combination pump (새로운 조합 펌프를 사용한 스테인레스 스틸 극고진공 시스템)

  • 전인규;조복래;정석민
    • Journal of the Korean Vacuum Society
    • /
    • v.7 no.1
    • /
    • pp.1-4
    • /
    • 1998
  • We have developed an extreme high vacuum (XHV) system using a new combination pump cpmposed of a suitably shaped NEG(Non-Evaporable Getters) in the body of a sputter-ion pump (SIP). The stainless-steel test chamber was used which had been well oxidized at $450^{\circ}C$ and already yielded XHV with a turbomolecular pumping system. The pressure was measured by a Leybold extractor gauge (EXG,limit:1~$2{\times}10^{-12}$torr, but in the ultimate pressure regionthe EXG shows an unusual sign as $-0.{\times}10^{-12}$ torr which indicates much lower pressure range than its available lower limit. These results are mainly due to the high pumping speed of NEG for hydrogen. Furthermore, use of the SIP combined with the NEG as a XHV pumping system implies the potential for actualization of the surface analysis under XHV environment, and allows one to have a chance tp meet a new world in nanometer science and technology.

  • PDF

Extending the Pressure Limit for Turbomolecular Pump up to 133 Pa by using Conductance-Reducer and Measuring the Pressure Differences in Vacuum Chamber (확장한 진공용기 내부의 압력구배 측정)

  • Hong, S.S.;Khan, Wakil;Kang, S.W.;Yun, J.Y.;Shin, Y.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.1
    • /
    • pp.1-9
    • /
    • 2010
  • A dynamic flow system has been developed which can be used for vacuum gauge calibration by comparison method - a calibration method in which the reading of the gauge under calibration is compared to another calibrated vacuum gauge called the "secondary standard" - and other vacuum-related experiments. The chamber of the calibration system is pumped by a turbomolecular pump (TMP), backed by a scroll pump. As maximum acceptable pressure at the inlet of a TMP is 0.1 Pa, above which the TMP decelerates, the pumping speed decreases and it becomes more difficult to adjust pressure under such circumstances. In the present work, high pressures of up to 133 Pa have been generated in the chamber of the newly developed dynamic flow control system by installing a well-designed conductance-reducer in the by-pass line and, at the same time, operating the TMP in safe mode. In addition, the gas flow and pressure distribution within the chamber have been investigated for the entire pressure range (0.1 Pa ~ 133 Pa) while generating pressure dynamically. Maximum deviations in pressure (1.6 %) were observed at point C on the chamber, which is close to the gas inlet port on the top of the chamber.