• Title/Summary/Keyword: Limit drawing ratio

Search Result 36, Processing Time 0.028 seconds

The Drawbility Estimation in Warm and Rot Sheet Forming Process of Magnesium for Substitution of Die-casting Process (다이캐스팅 공정의 대체를 위한 마그네슘판재의 온간, 열간 ???K드로잉 성형성 평가)

  • Choo D. K.;Oh S. W.;Lee J. H.;Kang C. G.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.05a
    • /
    • pp.407-410
    • /
    • 2005
  • The drawability of AZ31B magnesium sheet is estimated according to the variable temperatures (200, 250, 300, 350 and $400^{\circ}C$), forming speed (20, 50, 100 mm/min), thickness (0.8, 1.4 t), blank holding force (1.0, 1.4, 1.7kN). The deep drawing process (DDP) of circular cup is used in forming experiments. The results of deep drawing experiences show that the drawability is well at the range from 250 to $300^{\circ}C$, 50mm/min forming speed and 1.4kN blank holding force. The 0.8t magnesium sheets were deformed better than 1.4t. BHF was controlled in order to improve drawability and protect the change of cup thickness. When BHF was controlled, tearing and thickness change were decreased and LDR. was improved from 2.1 to 3.0.

  • PDF

Improvement of Dimensional Accuracy for a Solenoid Valve Case for an 8-Speed Automatic Transmission by Using Multistage Drawing (프로그레시브 공정을 이용한 8단 자동변속기용 솔레노이드 밸브케이스 치수정밀도 향상)

  • Kim, T.H.;Bae, W.B.;Bae, J.H.;Kim, C.
    • Transactions of Materials Processing
    • /
    • v.22 no.8
    • /
    • pp.442-449
    • /
    • 2013
  • The solenoid valve case of an 8-speed automatic transmission plays a role in maintaining the valve seal, which prevents an inflow of foreign substances into the transmission. The seal increases the reliability of the automatic transmission's performance. As a solution to pollution-related problems and to reduce fuel consumption, transmissions are being made with more gears to work more economically and have reduced fuel consumption. These newer transmission require greater dimensional tolerances and need to be manufactured with more precision. In the current study, the design of a multistage drawing considering both the product's height and limit draw ratio (LDR) of the material was performed using both a theoretical analysis and the expertise of industrial experts. The finite element modeling (FEM) simulation was performed using the commercial software, PAM-stamp, and tests of the dimensional measurements for a prototype were performed to verify the optimal progressive process.

Development of an Automated Design System of a Large Pressure Vessel using the Steel, 34CrMo4 (강재(34CrMo4)를 사용한 대형 고압가스 용기의 설계 자동화 시스템 개발)

  • Kim, Ji-Hoon;Kim, Eui-Soo;Kim, Chul;Choi, Jae-Chan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.8
    • /
    • pp.21-29
    • /
    • 2003
  • This paper describes a research work on the development of computer-aided design system for deep drawing & ironing of a high pressure vessel. An approach to the system is based on the knowledge-based rules. Knowledge for the system is formulated from plasticity theories, handbook, experimental results and empirical knowledge of field experts. An attempt is made to link programs incorporating a number of expert design rules with the process variables obtained by commercial FEM software, DEFORM and ANSYS, to form a useful package. It is composed of five main modules, which are calculation of product thickness, input, production feasibility check, process planning, and autofrettage process modules and two submodules, which are folding check and process variable verification submodules. Programs for the system have been written in AutoLISP on the AutoCAD 2000 using personal computer. The developed system makes it possible to design and manufacture large high pressure vessel requiring D.D.I. process more efficiently.

Comparative Study on the Building Outline Simplification Algorithms for the Conversion of Construction Drawings to GIS data (건설도면의 GIS 데이터 변환을 위한 건물외곽선 단순화기법 비교 연구)

  • Park, Woo-Jin;Park, Seung-Yong;Yu, Ki-Yun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.16 no.3
    • /
    • pp.35-41
    • /
    • 2008
  • Recently needs for the convergence of CAD and GIS data are increasing, and many studies on converting two systems to each other are being carried out. In this study, to revise and update the building data of digital map using CAD data for construction, the outline of building is abstracted from the CAD data and the outline is generalized to the same level of detail with the building data of digital map. Several line simplification algorithms to generalize the outline are adopted and compared, especially at the view of satisfaction to the drawing rule for digital map. Douglas-Peucker algorithm, Lang's algorithm, Reumann-Witkam algorithm, and Opheim algorithm are applied as the line simplification method. To evaluate the results of these algorithms, visual assessment and variation ratio of the number of points, total length of lines, the area of polygon, and satisfaction ratio to the drawing rule of digital map are analyzed. The result of Lang algorithm and Douglas-Peucker algorithm show superior satisfaction ratio. But general satisfaction ratio is 50~60% for all algorithm. Therefore there seems to be a limit to use these algorithms for the simplification method to update the building data in digital map and it is necessary to develop line simplification algorithm which satisfy the drawing rule well.

  • PDF

$^{99m}Tc-MAG_3$ Elimination Index on Normal Functioning Transplanted Kidney ($^{99m}Tc-MAG_3$ 제거지수를 이용한 이식신장의 기능평가)

  • Jeon, Woo-Jin;Kim, Ju-Heon;Park, Mi-Ok;Lee, Hee-Jung;Hyun, Jung-Ae;Zeon, Seok-Kil
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.79-83
    • /
    • 1995
  • Purpose : We analysed $^{99m}Tc-MAG_3$ renal scans to evaluate renal function of transplanted kidney and to detect various renal transplant complications, measuring the ratio of renal radioactivity at three minutes to that at 20 minutes(elimination index). Material and Methods : The fifty seven renal transplantation recipients were studied. There were 50 normal functioning transplanted kidneys as group I and 7 abnormal function-ing transplanted kidney, including 5 cases of acute renal rejection, 2 cases of acute tubular necrosis as group IIl. The protocol consisted of: (1) $^{99m}Tc-MAG_3$ 740MBq injection intravenously : (2) sequential imaging for 2min(60two-second images) followed by 30min(30 sixty-second images) : (3) drawing of region of interest(ROI) on renal imaging; (4) time-activity corves were generated from renal ROI after background subtraction, and time of maximum activity($T_{max}$) and half time of maximal peak radioactivity($T_{1/2}$) were produced in the renogram curve. (5) EI through Bischof-Delaloye method as determined on the renogram curve. Results : Normal group( I ) shows mean EI of 2.21(95.0% Confidence limit of 2.01-2.87), $T_{max}$ of 154 sec, $T_{1/2}$ of 1,139 sec. Abnormal group(II) shows mean EI of 0.74, $T_{max}$ of 1,466 sec, $T_{1/2}$ of 19,224 sec. The EI, $T_{max}$, $T_{1/2}$, BUN and serum creatinine values are significantly different between normal group(I) and abnormal group(II) (p<0.0001). Conclusion : By measuring EI with $^{99m}Tc-MAG_3$, renal function of transplanted kidney could be easily evaluated and various complications could be detected early.

  • PDF

The comparison of lesion localization methods in breast lymphoscintigraphy (Breast lymphoscintigraphy 검사 시 체표윤곽을 나타내는 방법의 비교)

  • Yeon, Joon ho;Hong, Gun chul;Kim, Soo yung;Choi, Sung wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.74-80
    • /
    • 2015
  • Purpose Breast lymphoscintigraphy is an important technique to present for body surface precisely, which shows a lymph node metastasis of malignant tumors at an early stage and is performed before and after surgery in patients with breast cancer. In this study, we evaluated several methods of body outline imaging to present exact location of lesions, as well as compared respective exposure doses. Materials and Methods RANDO phantom and SYMBIA T-16 were used for obtaining imaging. A lesion and an injection site were created by inserting a point source of 0.11 MBq on the axillary sentinel lymph node and 37 MBq on the right breast, respectively. The first method for acquiring the image was used by drawing the body surface of phantom for 30 sec using $Na^{99m}TcO_4$ as a point source. The second, the image was acquired with $^{57}Co$ flood source for 30 seconds on the rear side and the left side of the phantom, the image as the third method was obtained using a syringe filled with 37 MBq of $Na^{99m}TcO_4$ in 10 ml of saline, and as the fourth, we used a photon energy and scatter energy of $^{99m}Tc$ emitting from phantom without any addition radiation exposure. Finally, the image was fused the scout image and the basal image of SPECT/CT using MATLAB$^{(R)}$ program. Anterior and lateral images were acquired for 3 min, and radiation exposure was measured by the personal exposure dosimeter. We conducted preference of 10 images from nuclear medicine doctors by the survey. Results TBR values of anterior and right image in the first to fifth method were 334.9 and 117.2 ($1^{st}$), 266.1 and 124.4 ($2^{nd}$), 117.4 and 99.6 ($3^{rd}$), 3.2 and 7.6 ($4^{th}$), and 565.6 and 141.8 ($5^{th}$). And also exposure doses of these method were 2, 2, 2, 0, and $30{\mu}Sv$, respectively. Among five methods, the fifth method showed the highest TBR value as well as exposure dose, where as the fourth method showed the lowest TBR value and exposure dose. As a result, the last method ($5^{th}$) is the best method and the fourth method is the worst method in this study. Conclusion Scout method of SPECT/CT can be useful that provides the best values of TBR and the best score of survey result. Even though personal exposure dose when patients take scout of SPECT/CT was higher than another scan, it was slight level comparison to 1 mSv as the dose limit to non-radiation workers. If the scout is possible to less than 80 kV, exposure dose can be reduced, and also useful lesion localization provided.

  • PDF