• 제목/요약/키워드: Lightning impulse

검색결과 228건 처리시간 0.037초

반구형 전극계에서 뇌임펄스전압에 의한 토양의 종류별 이온화 특성 (Ionization Behaviors by Types of Soil due to Lightning Impulse Voltages in a Hemishperical Electrode System)

  • 이규선;박건훈;김회구;이복희
    • 전기학회논문지
    • /
    • 제58권1호
    • /
    • pp.119-125
    • /
    • 2009
  • This paper deals with the characteristics of soil ionization affecting the dynamic performance of grounding systems under lightning impulse voltage. A concentric hemispherical electrode system was employed in order to facilitate the field calculation and analysis of the experimental results. The parameters such as the ionization threshold and breakdown field intensity, the pre-ionization and the post ionization resistances, the time-lag to ionization, the transient impedance, the equivalent ionized radius for various soil media were measured and analyzed. The dynamic characteristics of ionization processes under lightning impulse voltage are strongly dependent on the types of soil and water content. As a result, a soil ionization reduces the ground resistance and there is a little effect of applied impulse polarity on the soil ionization threshold field intensity. Although the ionization threshold field intensity of wet clay with 30% water content is the highest, its ionized zone was found to be the smallest amongst the test samples.

Evaluation on the Lightning Breakdown Voltages of Palm Oil and Coconut Oil under Non-Uniform Field at Small Gap Distances

  • Thien, Yee Von;Azis, Norhafiz;Jasni, Jasronita;Kadir, Mohd Zainal Abidin Ab;Yunus, Robiah;Ishak, Mohd Taufiq;Yaakub, Zaini
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권1호
    • /
    • pp.184-191
    • /
    • 2016
  • In recent years, there are a number of studies that have been carried out to explore the alternative for Mineral Oil (MO) as dielectric insulating fluid in transformers due to the increasing tight regulation on safety and environment. Vegetable oils have been identified as suitable candidate since it is biodegradable, non-toxic and high flash/fire points which ensure more in-service safety. Among the types of vegetable oils considered for transformers application are Palm Oil (PO) and Coconut Oil (CO). This paper presents an experimental study on the lightning breakdown voltages of PO and CO under non-uniform electric field based on needle-sphere electrodes configuration at 3 small gap distances. The type of PO used in this study is Refined Bleached and Deodorized Palm Oil (RBDPO) Olein. The main focus of this study is to examine the lightning breakdown performance of RBDPO and CO under different test conditions and assess its suitability as dielectric insulating fluid in transformers. The effect of voltage polarities (positive and negative) and testing methods (rising-voltage, up-and-down and multiple-voltage) were investigated. The data obtained from all tests were analysed by Weibull distribution in order to determine the withstand voltages for each type of oils. It was found that the breakdown voltages of RBDPO and CO are comparable with MO under positive lightning impulse. Under negative lightning impulse, the breakdown voltage of MO is slightly higher than RBDPO and CO. There is no significant effect of testing methods and voltage polarities on lightning breakdown voltages of RBDPO and CO. Based on the statistical analysis, it is found that the breakdown voltages of RBDPO and CO at 1% probability are slightly lower than MO.

뇌충격전압 국가표준 측정기술 개발 (Development of National Lightning Impulse Voltage Standard Measuring Technology)

  • 김민규;정주영;김익수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1744-1746
    • /
    • 2003
  • This paper represents the development of national standard (NS) for lightning impulse (LI) voltage measuring system rated 400 kV. A traceability of the NS to the international standard could be achieved by the intercomparison test with Helsinki University. According to the IEC 60060-2, a measurement uncertainty was assessed. As a result of the tests, a measurement uncertainty and step response characteristics were satisfied with the requisite for NS.

  • PDF

$SF_6-N_2$ 혼합가스에서 과도임펄스전압에 대한 V-t특성 (V-t Characteristics in $SF_6-N_2$ Mixtures for Transient Impulse Voltages)

  • 이복희;이경옥
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권9호
    • /
    • pp.456-465
    • /
    • 2001
  • In this paper, breakdown voltages in $SF_6-N_2$ mixtures were experimentally investigated to understand characteristics of dielectric strength and physical phenomena in nonuniform field disturbed by a needle shape protrusion. The test voltages are the lightning impulse$(\pm1.2/44 \mus)$ and the damped oscillatory impulse$(\pm400 ns / 0.83 MHz)$ voltages which can be occurred by the operation of disconnecting switches in gas-insulated switchgears(GIS). The effects of the polarity and wave shape of the test voltages, and the gas pressure on the V-t characteristics were in detail examined. The V-t characteristic curves were measured in different two ways : (1) one is the method by taking the maximum voltage recorded at or prior to breakdown against the time to breakdown, that is, the Procedures recommended in IEC 60060-1, (2) the other is the method by taking the voltage at the instant of chopping against the time to breakdown. As a result, the V-t characteristics of $SF_6-N_2$ mixtures in nonuniform electric field were significantly affected by the polarity and wave shape of the applied voltages. The positive breakdown voltages resulted in lower breakdown voltages in the time ranges considered, and the V-t curves for the negative oscillatory impulse voltage were extended over the longer time range. For the lightning impulse voltages, the V-t curves obtained by IEC Pub. 60060-1 were nearly same with the V-t curves obtained by the voltage at the instant of chopping against the time to breakdown. It is clear that the actual breakdown voltages were much lower than the maximum voltages appearing at or prior to breakdown because of the displacement current produced as a result of the dV/dt during the oscillatory transient voltage app1ication. The scattering of the negative actual breakdown voltages was much larger than that of the positive.

  • PDF

불평등전극계에서 뇌임펄스전압에 대한 $N_2$기체의 절연파괴 특성 (The breakdown characteristics of $N_2$ gas with lightning impulse voltage in the non-uniform electrode)

  • 이복희;이봉;조정현
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.301-304
    • /
    • 2008
  • This paper presents the experimental results on breakdown characteristics in $N_2$ gas under non-uniform electric fields caused by both the positive and negative lightning impulse voltages. $N_2$ gas have an advantage of eco-friendly and cost reduction, and safety aspects. In order to analyze the impulse pre-breakdown processes in $N_2$ gas, we carried out measurements and observations of the impulse breakdown voltages, pre-breakdown current and luminous signals. They were measured by a voltage divider, a shunt and a photo-multiplier tube, respectively. Additionally, the characteristics of discharge channels were observed by high speed cameras. The breakdown voltages in the positive polarity was lower than those in the negative polarity.

  • PDF

충격전압발생기 트리거 시동장치 성능개선 (Improvement of triggering system of impulse voltage generator for Extra high-voltage)

  • 허종철;박승재;문인욱;박정후;오창수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1704-1706
    • /
    • 2002
  • With increasement of use in electricity energy, quality of electric apparatus has been recognized as important factor in distribution and transmission line. Especially In laboratories, lightning and switching impulse performances of electric apparatus have been carrying out by impulse voltage generator (IVG), simulated into lightning and switching surge circuit. In this paper, we describe triggering system of impulse voltage generator(IVG) for extra high voltage, which has been newly designed.

  • PDF

불평등전계 중에서 $SF_{6}-N_{2}$ 혼합기체의 절연파괴 특성 (Breakdown Characteristics of $SF_{6}-N_{2}$ Mixtures in Nonuniform electric Field)

  • 이복희;이경옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1999-2001
    • /
    • 2000
  • Impulse breakdown voltage characteristics of sulphur-hexafluoride/nitrogen ($SF_{6}-N_{2}$) mixtures were presented. The applied voltages were the positive and negative lightning impulse (1.2/44${\mu}s$) and oscillating impulse ($0.4{\mu}s$/2.08MHz) voltages. The predischarge current was observed to clarify the breakdown mechanism. The electrode system was consisted of plane to plane configuration with a needle-shaped protrusion whose length and diameter are 10mm and 1mm. The measurements were carried out at the gas pressure of mixtures up to 0.5MPa with nitrogen concentrations varying from 5 to 20%. The electrical breakdown in $SF_{6}-N_{2}$ mixtures develops with steplike pulses in leader mechanism. The minimum breakdown voltages for the negative lightning and oscillating impulse voltages were higher than those for the positive.

  • PDF

온도변화에 따른 $SF_{6}/N_{2}$ 혼합가스의 절연특성 (Breakdown Characteristics of $SF_{6}/N_{2}$ Gas Mixtures According to a change in Temperature)

  • 이복희;이봉;최종혁;백영환;정동철;김성원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1455-1456
    • /
    • 2007
  • This paper presents the experimental results on impulse breakdown characteristics under a highly non-uniform electric field in $SF_{6}/N_{2}$ gas mixtures according to a change in temperature. Test temperature ranges from $-25^{\circ}C$ to $25^{\circ}C$. The impulse predischarge breakdown developments are investigated by the measurements of current pulse and discharge luminous events. As a result, the predischarge development mechanisms for both positive and negative polarities are same. When increasing the temperature, breakdown voltage due to lightning impulse voltage is increased in negative polarity. On the other hand, when increasing the temperature, breakdown voltage due to lightning impulse voltage is not changed in positive polarity.

  • PDF

산화아연 피뢰기 소자의 다중 뇌 임펄스 특성 (Effect of Multiple Lightning Impulse Currents on Zinc Oxide Arrester Blocks)

  • 이복희;강성만;박건영;최휘성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.22-24
    • /
    • 2003
  • In this work, in order to investigate the effect of multiple lightning impulse currents on zinc oxide arrester blocks. We have been designed and fabricated a multi-impulse generator which can produce quintuple voltages with $1.2/50{\mu}s$ to 100kV and quintuple currents with $8/20{\mu}s$ to 12kA and we have evaluated the characteristics of zinc oxide arrester block using several electrical and physical methods after the multi-impulse test. It was found that the multi-impulse failures of ZnO arrester blocks were mainly caused by surface flashover and the multi-impulse currents test would be more suitable than single impulse current test in evaluation of the characteristics of zinc oxide arrester blocks corresponding to actual situations.

  • PDF

Crowbar 장치를 이용한 최초 단시간뇌격전류 발생기술 및 뇌격전류발생기 개발 (Development of Lightning Current Generator and Technology for Generating the First Short Stroke Lightning Current Using a Crowbar Device)

  • 엄주홍;이태형;권기량;조성철
    • 조명전기설비학회논문지
    • /
    • 제25권1호
    • /
    • pp.93-100
    • /
    • 2011
  • This paper presents a technical study for the first short stroke lightning current generator using a crowbar device. The so-called crowbar-technology is most common to make 10/350[${\mu}s$] impulse currents with high amplitude, and the lightning current generator with crowbar device has an economic advantage than the nominal RLC current generator. But both the operating efficiency and the operating reliability of crowbar spark gap are very important to design the current generator. So, the peaking circuit which consists of small capacitors and a spark gap is applied. And the multi-step coil for controlling the circuit constant at the different test conditions is used. The presented test facility is designed to perform impulse tests with amplitudes up to 50[kA] of 10/350[${\mu}s$].