• Title/Summary/Keyword: Lightning damage

Search Result 110, Processing Time 0.028 seconds

Statistics of Casualties and Damage Caused by Lightning Strikes in Korea from 2000 to 2007

  • Kim, Dong-Seong;Lee, Bok-Hee;Jeon, Duk-Kyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.7
    • /
    • pp.14-19
    • /
    • 2009
  • This paper presents statistics on lightning-caused damage to humans, structures, and electrical and electronic equipment. To reduce the number and amount of casualties and damage caused by lightning strikes, the statistical analysis of lightning-related damage reports is important in establishing lightning protection measures. The statistics of lightning death, injury and damage in Korea from 2000 to 2007 were primarily derived from mass media As a result, the annual average of lightning-caused deaths in Korea is about 5. Most lightning casualties involve people who work outdoors such as farmers and recreationists. Data on lightning-caused injuries to humans and damage to structures in this paper may be underestimated since the available data from mass media are incomplete. The actual lightning-caused casualties and damage in Korea may be greater than those presented in this paper.

Certification of Structure Damage from Direct Lightning (항공기 집접낙뢰에 대한 동체 구조손상 인증)

  • Lee, Haesun
    • Journal of Aerospace System Engineering
    • /
    • v.6 no.3
    • /
    • pp.13-18
    • /
    • 2012
  • Every 3000 hour an aircraft is stricken by a lightning. Also the lightning damage to the aircraft during flight are continually occurred due to extreme weather phenomena such as global warming. Under the airworthiness standards, the aircraft must be designed to protect lightning. To show compliance for lightning, the test should be conducted by the actual lightning current and voltage waveform for the actual aircraft or parts. After test, structure damage is detected via visual inspection or NDI. Structure substantiation for damage is to show retaining limit or near limit load capability. This is conducted by test or analysis based on test. Thus, the aircraft should retain structural strength to land safely, even though the damage of aircraft fuselage from Lightning strike are occurred.

A Comparative Study on Lightning Characteristics and Lightning Damage to Wind Turbines of Jeju and Gangwon Region (제주와 강원 지역의 낙뢰특성 및 풍력발전기의 낙뢰피해 비교 연구)

  • Yang, Dal-Seung;Kim, Kyoung-Bo;Ko, Kyung-Nam
    • Journal of Power System Engineering
    • /
    • v.18 no.5
    • /
    • pp.137-143
    • /
    • 2014
  • An investigation on lightning characteristics and damage to wind turbines was performed on Jeju and Gangwon regions. The lightning data from January 2010 to September 2013 detected by IMPACT ESP were collected and analyzed in detail. Hangyeong and Seongsan wind farms of Jeju province and Taebaek, Changjuk, Taegisan and Gangwon wind farms of Gangwon province were selected for this study. Lightning rates and lightning damage events at the six wind farms were compared with each other. Lightning maps for the two regions were drawn using lightning frequency data. As a result, lightning frequency of Gangwon region was higher than that of Jeju region, while lightning strength of Gangwon was weaker than that of Jeju. Lightning rates were assessed to be good for all of the six wind farms. No lightning damage to wind turbines occurred at the two wind farms of Jeju, while some lightning damage to wind turbines took place at the four wind farms of Gangwon.

Lightning Characteristics and Lightning Rate Evaluation of Wind Farm by Lightning of Jeju Island for 2008-2012 (2008-2012년의 제주지역 낙뢰 특성 및 낙뢰에 의한 풍력단지 낙뢰율 평가)

  • Han, Ji-Hoon;Ko, Kyung-Nam;Huh, Jong-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.5
    • /
    • pp.60-68
    • /
    • 2013
  • This paper presents the characteristics of lightning over established and scheduled wind farms of Jeju island as well as over specific range of entire Jeju Island. The lightning data for 5 years from 2008 to 2012 was obtained from IMPACT ESP which detects lightning. Lightning frequency, lightning strength and regional lightning events were analyzed in detail, and then the lightning maps of Jeju Island were created. The evaluation of lightning rate was made for all the wind farms of this study. Damage to wind turbines by lightning was found in the existing wind farms. As a result, the eastern part of Jeju Island had more lightning frequency than the western part of the Island. Also, the evaluation of lightning rate was good for all established and scheduled wind farms of Jeju Island. Hankyung is the best place for lightning safety, while precaution should be taken against lightning damage in Kimnyung. Lightning damage to wind turbines occurred in Samdal and Haengwon wind farms, which had the first and the second highest lightning rate of the five existing wind farms.

An Application Method and Review of Lightning Protection for Wind Turbines (풍력발전기의 낙뢰피해 대책 검토 및 적용방안)

  • Han, Ji-Hoon;Ko, Kyung-Nam;Huh, Jong-Chul
    • Journal of Power System Engineering
    • /
    • v.19 no.2
    • /
    • pp.5-14
    • /
    • 2015
  • This investigation presents reviews of many research results on lightning damage to wind turbines and lightning protection strategies from IEC Standard, Europe, USA, Japan and Korea. There have been few studies on lightning protection of wind turbines in Korea, while various investigations have been performed in the other countries. It is necessary to apply some good lightning protection strategies of IEC Standard and the other countries to Korea. Those are as follows: The guideline for lightning protection of wind turbines should be established based on IEC Standards. It needs to be carried out both development of software and experimental studies for understanding the types of lightning damage to wind turbines and compiling the database. In order to minimize the lightning damage to wind turbines, it is a key factor for wind farm owners and researchers to provide the information about the damage cases and wind farm operation technique.

Acoustic Emission Monitoring of Lightning-Damaged CFRP Laminates during Compression-after-Impact Test

  • Shin, Jae-Ha;Kwon, Oh-Yang
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.3
    • /
    • pp.269-275
    • /
    • 2012
  • Carbon-fiber reinforced plastic(CFRP) laminates made of nano-particle-coated carbon fibers and damaged by a simulated lightning strike were tested under compression-after-impact(CAI) mode, during which the damage progress due to compressive loading has been monitored by acoustic emission(AE). The impact damage was induced not by mechanical loading but by a simulated lightning strike. Conductive nano-particles were coated directly on the fibers, from which CFRP coupons were made. The coupon were subjected to the strikes with a high voltage/current impulse of 10~40 kA within a few ${\mu}s$. The effects of nano-particle coating and the degree of damage induced by the simulated lightning strikes on AE activities were examined, and the relationship between the compressive residual strength and AE behavior has been evaluated in terms of AE event counts and the onset of AE activity with the compressive loading. The degree of impact damage was also measured in terms of damage area by using ultrasonic C-scan images. The assessment during the CAI tests of damaged CFRP showed that AE monitoring appeared to be useful to differentiate the degree of damage hence the mechanical integrity of composite structures damaged by lightning strikes.

Characteristics of Lightning Occurred over Jeju Island for 2004-2006 and an Effect of Lightning on Wind Turbine Generator System (2004-2006년에 발생한 제주지역의 낙뢰 특성 및 풍력발전기에 미치는 낙뢰의 영향)

  • Ko, Kyung-Nam;Kim, Kyoung-Bo;Huh, Jong-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.1
    • /
    • pp.83-89
    • /
    • 2008
  • This paper presents the characteristics of lightning pver Jeju island and a case of emergency stop of a wind turbine due to lightning. Using the IMPACT ESP sensor to detect lightning, the data on lightning frequency, lightning strength, regional lightning event were obtained and analyzed in detail. The measurement period was for 3 years from 2004 to 2006. As a result, lightning occulted the most frequently in July and August. As for lightning strength, lightning with grades -4 to -6 and +3 to +5 occur ed more frequently. The eastern part of Jeju island had much more lightning frequency compared with the western part of it. Lightning with high grade occurred mainly in offshore site and the coastal region. Furthermore, the data on wind turbine stop caused by lightning was analyzed. Although wind turbine lightning damage was not much in this study, the investigation on lightning damage or lightning faults to a wind turbine should be conducted in Korea to increase availability of wind turbine.

Seismic Fragility Analysis of Lightning Arrester Considering Various Damage States (다양한 손상상태를 반영한 피뢰기 설비의 지진취약도 해석)

  • Shin, Yooseong;Song, Jong-Keol
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.18 no.1
    • /
    • pp.19-28
    • /
    • 2014
  • The seismic evaluation of electric power facilities in the switchyard of nuclear power plants is currently insufficient. In order to evaluate the seismic performance of lightning arrester subjected to four types of earthquake (near- and far-fault earthquakes, NEHRP Site Class A&B and D earthquakes), seismic fragility analysis using maximum likelihood estimation is performed considering various damage states. The comparison of the seismic fragility curves for three main parts of lightning arrester that are the busing, anchor and steel frame, reveals that the failure of lightning arrester is governed by the bushing damage mode such as porcelain cracking.

Review about the Lightning Protection System for Ground Facilities of Anti-aircraft Weapons System (뇌 보호시스템의 대공무기체계 지상시설 적용에 대한 고찰)

  • Jung, Kyoungwook;Shim, Donghyouk;Son, Donghyeop
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.339-347
    • /
    • 2021
  • Recently, the incidence of lightning in Korea has been increasing more and more. The damage caused by lightning is also getting worse. Lightning protection system is a prerequisite, not a sufficient condition. Considering the characteristics of lightning, there is a high frequency of lightning strikes in highlands. So, high grades of LPS should be applied to ground facilities of anti-aircraft weapons systems. 4-Level LPS was applied on groung facilities of anti-aircraft weapons system based on lightning incidence rate in past. There are some possibilities of damage from lightning in anti-aircraft weapons system. So, we have to readjust the LPS level with grounding, lightning rods and surge protect device based on lightning incidence rate in now days. Propose 2-level LPS and design with lightning rods, surge protector, separated grounding in this paper.

Development and Verification of Lightning Induced Transient Protection Device for Avionics Computer (항공기 탑재 컴퓨터용 간접낙뢰 보호장치 개발 및 검증)

  • Sim, Yong-gi;Ahn, Tae-sik;Park, Jun-hyun;Han, Jong-pyo;Yang, Seo-hee
    • Journal of Advanced Navigation Technology
    • /
    • v.19 no.5
    • /
    • pp.395-402
    • /
    • 2015
  • This paper introduces the design details and test procedures of the lightning induced transient protection device for protecting the damage caused by indirect lightning strike on the computer mounted on the aircraft. Lightning induced surge voltage is bring a malfunction or damage to the aircraft electrical and electronic equipment, that is referred to indirect effects of lightning. In order to protect the electronic equipment on aircraft from the indirect effects of lightning, that is achieved by analyzing the effect on aircraft from lightning and protect design for each devices. In this paper, we introduce an indirect lightning strike level decisions, the protection circuit design method according to the chosen level through the RTCA DO-160G Section 22 category analysis and selection was performed in order to protect the damage caused by indirect lightning strikes in the protected equipment. In addition, we show the indirect lightning effects verification test performed to validate the designed protection circuits.