• Title/Summary/Keyword: Lightning Faults

Search Result 43, Processing Time 0.032 seconds

Transient State Analysis of Faults Caused by Lightning Surge in Distribution Line (뇌서지에 의한 배전선로 고장 시 과도상태 분석)

  • Lim, Sung-Yong;Kim, Kyu-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.1
    • /
    • pp.51-57
    • /
    • 2016
  • This paper presents the voltage characteristics of the various faults after lightning surge hits the overhead grounding wire close to the transformer's secondary side. Based on the modeled distribution system, the cases of the various faults occurred by lightning surge are simulated using EMTP/ATPDraw and maximum overvoltage and RMS voltage according to the distances from the transformer are investigated. As a result, it is seen that the voltage characteristics of faults caused by lightning surge is different depending on the fault type and the voltage characteristics can be used to detect the fault type caused by lightning surge.

Analysis of the lightning characteristics by the Lightning DB in KOREA (낙뢰위치표정시스템의 낙뢰 DB를 이용한 한반도 뇌격 특이특성 분석)

  • Woo, J.W.;Kwak, J.S.;Shim, E.B.;Lee, G.W.;Kim, K.W.;Kim, B.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1658-1660
    • /
    • 2001
  • Because the overhead transmission lines are exposed to the outdoor weather, the faults of the transmission lines are due to natural conditions, and among these faults, the outage rate by lightning is about 50%. The lightning causes the damage of power system equipments, the shut down of electricity and the electro-magnetic interference. Therefore, the pertinent insulation design is important, not only to decrease the damage of the facility itself but also to increase the reliability of electric power system. For these reasons, we have to obtain and accumulate the lightning current parameters for the basic lightning research. This paper describes the statistical distribution of lightning current parameters and the IKL map.

  • PDF

Analysis of the lightning characteristics by the LPATS in KOREA (낙뢰위치 표정시스템(LPATS)에 의한 2004넌 한반도 낙뢰통계 분석결과)

  • Kwak, J.S.;Woo, J.W.;Kweon, D.J.;Kang, Y.W.;Moon, J.D.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.606-608
    • /
    • 2005
  • As the overhead transmission lines are exposed to the outdoor weather, the causes of the transmission lines faults are from natural conditions, and among these faults, the outage rate due to lightning is more than 60%. The lightning causes the damage of power system equipments, the shut down of electricity and the electro-magnetic interference. Therefore, the pertinent insulation design is important, not only to decrease the damage of the facility itself but also to increase the reliability of electric power system. For these reasons, we have to obtain and accumulate the lightning current parameters for the basic lightning research. This paper describes the statistical distribution of lightning current parameters and the IKL map.

  • PDF

Lightning observation by KLDNet and analysis on lightning activities of Korea in 2007 (한전낙뢰감지네트워크(KLDNet)에 의한 우리나라의 2007년도 낙뢰측정 및 분석)

  • Kwak, Joo-Sik;Kang, Yweon-Woog;Woo, Jung-Woog;Koo, Kyo-Sun;Kweon, Dong-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.438-439
    • /
    • 2008
  • KEPCO has been operating a lightning detection network, KLDNet, to cope with lightning-induced faults. An weather observation for last 40 years shows that heavy rainy days per year and the strength of rain have almost doubled. It could be interpreted as more frequent occurrence of lightning events. In accordance with that, the lightning activities and the mischievous influences, such as transmission faults, have increased. In this paper, the observed data by the network in 2007 is analyzed and compared with ten-years-old-statistics accumulated by the former system, LPATS.

  • PDF

Analysis of LPATS-III Error Level and the lightning characteristics in KOREA (LPATS-III의 오차검토 및 한반도 낙뢰발생빈도 분석결과)

  • Woo, J.W.;Shim, E.B.;Kwon, D.J.;Choi, Y.M.;Lee, S.J.;Kim, K.W.;Lee, B.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1772-1774
    • /
    • 2002
  • Because the overhead transmission lines are exposed to the outdoor weather, the faults of the transmission lines are due to natural conditions, and among these faults, the outage rate by lightning is about 50%. The lightning causes the damage of power system equipments, the shut down of electricity and the electro-magnetic interference. To study the basic research of the lightning parameters for power system operation, LPATS-III (Lightning Positioning and Tracking System) has been introduced since 1995 in Korea. This paper describes the inspection result about location information error and the statistical distribution of lightning current.

  • PDF

Insulation Design Standards for Protection of Power System against Lightning in Korea Electric Power Corporation (낙뢰로부터 전력설비 보호를 위한 한전의 절연설계 기준)

  • Woo, J.W.;Moon, J.D.
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.12
    • /
    • pp.555-560
    • /
    • 2006
  • As it has been reported that more than 60% of transmission line faults occurs due to lightning strokes, lighting is one of concerned issues in electric power utility company. Most of transmission line is double circuit in Korea. Double circuit outages account for 33.7 percent of total lightning faults from 1996 to 2004. Even though transmission fault might be cleared shortly by protective system, it could deteriorate the power quality accompanied with sag or flicker. Moreover, double circuit fault may lead to more aggravated situation, for instance, blackout. To Protect transmission lines from lightning stroke, reduction of tower footing resistance, multiple ground wires and unbalanced insulation in double circuit lines have been adopted. In this paper, we would like to introduce insulation design standards for lightning protection of Korea Electric Power Corporation.

Development of Real Time Analysis System about Lightning Information (낙뢰정보 실신간 통계분석시스템 개발)

  • Kwak, J.S.;Woo, J.W.;Shim, E.B.;Kim, K.W.;Kim, Y.S.;Lee, S.J.;Lee, G.W.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.169-171
    • /
    • 2003
  • Because the overhead transmission lines are exposed to the outdoor weather, the faults of the transmission tines are due to natural conditions, and among these faults, the outage rate by lightning is about 50%. The lightning causes the damage of power system equipments, the shut down of electricity and the electro-magnetic interference. Therefore, the pertinent insulation design is important, not only to decrease the damage of the facility itself but also to increase the reliability of electric power system. For these reasons, we have to obtain and accumulate the lightning current parameters for the basic lightning research. This paper describes the development of real time analysis system about lightning information.

  • PDF

Development of Heal Time Lightning Information System (실시간 낙뢰화면 표시프로그램 개발)

  • Kwak, J.S.;Woo, J.W.;Shim, E.B.;Kim, K.W.;Kim, Y.S.;Lee, S.J.;Lee, G.W.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.175-177
    • /
    • 2003
  • Because the overhead transmission lines arc exposed to the outdoor weather, the faults of the transmission lines are due to natural conditions, and among these faults, the outage rate by lightning is about 50%. The lightning causes the damage of power system equipments, the shut down of electricity and the electro-magnetic interference. Therefore, the pertinent insulation design is important, not only to decrease the damage of the facility itself but also to increase the reliability of electric power system. For these reasons, we have to obtain and accumulate the lightning current parameters for the basic lightning research. This paper describes the development of real time analysis system about lightning information.

  • PDF

Analysis of the lightning characteristics by LPATS Data during 7 year (LPATS에 의한 7년간의 한반도 뇌격특성분석)

  • Woo, J.W.;Shim, E.B.;Kwak, J.S.;Kweon, D.J.;Moon, J.D.;Han, S.O.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.509-511
    • /
    • 2003
  • Because the overhead transmission lines are exposed to the outdoor weather, the faults of the transmission lines are due to natural conditions, and among these faults, the outage rate by lightning is about 50%. The lightning causes the damage of power system equipments, the shut down of electricity and the electro-magnetic interference. Therefore, the pertinent insulation design is important, not only to decrease the damage of the facility itself but also to increase the reliability of electric power system. For these reasons, we have to obtain and accumulate the lightning current parameters for the basic lightning research. This paper describes the statistical distribution of lightning current parameters and the IKL map.

  • PDF

The analysis and countermeasure to the lightning fault of transmission facilities (송전설비의 낙뢰고장사례 분석과 대책)

  • Sin, S.G.;An, J.S.;Bak, S.Y.;NamKung, D.;Han, S.O.;Choi, N.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.412-415
    • /
    • 2000
  • Generally, the fault of transmission facilities occurs by natural and artificial causes. Also, these faults are frequently developed by the lightning, a natural phenomenon. Therefore, In this paper, we investigated the case of lightning faults for transmission lines occurred for five years in the west and south of chung-nam province, and then considered a suitable countermeasure for lighting faults in these area

  • PDF