• Title/Summary/Keyword: Lightning Detection

Search Result 39, Processing Time 0.032 seconds

The new lightning detection system of KEPCO Lightning Detection & information Network (한전의 새로운 낙뢰측정 네트워크 KLDNet)

  • Woo, J.W.;Kwak, J.S.;Shim, E.B.;Won, B.J.;Moon, J.D.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.83-84
    • /
    • 2006
  • Lightning induced faults accounts for more than 66% at the transmission lines of KEPCO. The lightning causes damages to power system equipments including transmission line, the shut down of electricity and the electro-magnetic interference. Because of this reason, we need the real time lightning information for the optimal operation of power system. And, it is required to obtain and accumulate the lightning current parameters for the insulation design. A lightning detection system, LPATS, has been operated since 1995 in KEPCO. For the improved detection efficiency, we had in stalled the new lightning detection network named as KLDNet in 2005. Also, we had developed the new software for the lightning parameters analysis and real time information service on the WEB. In this paper, we would like to introduce about the new system.

  • PDF

A study on the Site Survey and Detection Efficiency for Kepco Lightning Detection and Information Network (낙뢰측정 네트워크(KLDNet)를 위한 감지기 사이트서베이와 낙뢰 감지율 검토)

  • Woo, J.W.;Kwak, J.S.;Moon, J.D.
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.11
    • /
    • pp.532-537
    • /
    • 2006
  • Lightning induced faults accounts for more than 66% at the transmission lines of KEPCO. The lightning causes damages to power system equipments including transmission line, the blackout of electricity and the electro-magnetic interference. Because of this reason, we need the real time lightning information for the optimal operation of power system. And, it is required to obtain and accumulate the lightning current parameters for the insulation design. In 2005, KEPRI constructed a lightning detection network, the KLDNet (i.e. Kepco Lightning Detection & Information System) and launched a lightning information service for KEPCO customers. It is intended to provide data service on the operation of transmission lines and collect lightning-related data, which is the most important factor regulating power system design and operation. The new system will replace LPATS, the old detection system, which has been operating since 1995 and is rapidly failing in terms of both detection performance and location accuracy. The purpose of this paper is to explain the work performed and the results of that work in performing a site survey of several locations. The purpose of the site survey is to find locations acceptable for the installation of a lightning location receiver in support of a Lightning detection system(LDS). A restriction was placed on the surveyed locations, as they must belong to the Korea Electric Power Company. This requirement was made to facilitate the communication needs of the LDS network. Total of 15 sites were evaluated as possible LDS sensor sites. Some of the sites were rejected for physical reasons and therefore no electrical testing was performed. Of the 15 sites, total of 10 sites were considered acceptable and 5 sites were rejected for various reason. In this paper, we would like to explain the site survey and detection efficiency for LDS.

A Study on the Design for Lightning Detection System of AOA methods for 3D Lightning Detection (낙뢰의 3차원 관측 위한 AOA 방식 낙뢰감지기 설계에 관한 연구)

  • Woo, J.W.;Kwak, J.S.;Moon, J.D.;Kawasaki, Zenichiro
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.11
    • /
    • pp.527-531
    • /
    • 2006
  • Since 1996, KEPCO has been operating a wide range lightning detection system, LPATS, and been accumulating relative application techniques and statistical analysis skills. So, KEPRI already has its own basis to develope more accurate advanced detection technology and references to do comparative study. For three-dimensional imaging of lightning channels, UHF/VHF antenna systems were installed at 2 sites. The distance between two sites is about 30 km. These systems were used the AOA(Angle of Arrival) methods for lightning detection. In this paper, we would like to introduce about our system and its results.

Development of a Detect-and-Acquisition System for Broadband Lightning Signals (광대역 낙뢰신호 탐지 및 획득 시스템 개발)

  • Song, Seung-Hun;Kim, Dong-Hyouc;Lee, Sung-Ho;Woo, Jung-Wook;Sung, Tae-Kyung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1503-1510
    • /
    • 2007
  • To implement a high-precision lightning tracking system utilizing TDOA measurements, high-speed data acquisition and precise timing synchronization between ground sensors should be achieved. At the same time, considering the size of digitizer's memory, the data memory needs to be managed so that only the sampled data around the occurrence of stepped leader pulse is stored. This paper presents a detection-and-acquisition system for lightning signals that is the main equipment of ground sensor in lightning tracking system. GPS clock module is used to get precise timing synchronization and the 500MHz high speed digitizer is employed. In order to detect the leading edge of the lightning pulse and save the sampled data and its timing, lightning detection module is implemented and multi-record method is employed in the proposed system. Field experiment results show that the proposed system can detect and save the lightning signal efficiently.

Improvement of Thunderstorm Detection Method Using GK2A/AMI, RADAR, Lightning, and Numerical Model Data

  • Yu, Ha-Yeong;Suh, Myoung-Seok;Ryu, Seoung-Oh
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.1
    • /
    • pp.41-55
    • /
    • 2021
  • To detect thunderstorms occurring in Korea, National Meteorological Satellite Center (NMSC) also introduced the rapid-development thunderstorm (RDT) algorithm developed by EUMETSAT. At NMCS, the H-RDT (HR) based on the Himawari-8 satellite and the K-RDT (KR) which combines the GK2A convection initiation output with the RDT were developed. In this study, we optimized the KR (KU) to improve the detection level of thunderstorms occurring in Korea. For this, we used all available data, such as GK2A/AMI, RADAR, lightning, and numerical model data from the recent two years (2019-2020). The machine learning of logistic regression and stepwise variable selection was used to optimize the KU algorithms. For considering the developing stages and duration time of thunderstorms, and data availability of GK2A/AMI, a total of 72 types of detection algorithms were developed. The level of detection of the KR, HR, and KU was evaluated qualitatively and quantitatively using lightning and RADAR data. Visual inspection using the lightning and RADAR data showed that all three algorithms detect thunderstorms that occurred in Korea well. However, the level of detection differs according to the lightning frequency and day/night, and the higher the frequency of lightning, the higher the detection level is. And the level of detection is generally higher at night than day. The quantitative verification of KU using lightning (RADAR) data showed that POD and FAR are 0.70 (0.34) and 0.57 (0.04), respectively. The verification results showed that the detection level of KU is slightly better than that of KR and HR.

Analysis of Lightning observed by KEPCO Lightning Detection Network (한전낙뢰관측 시스템 KLDNet의 낙뢰관측 결과 분석)

  • Kwak, J.S.;Park, M.H.;Jeong, M.J.;Ju, H.J.;Oh, S.Y.;Kim, H.S.;Woo, J.W.;Han, K.S.;Goo, S.G.
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.398-399
    • /
    • 2015
  • The fault level of power transmission lines caused by natural disaster such as lightning and rainstorm has been on the rise. Especially, the cause of lightning stokes is large part of transmission faults. In order to reduce the lightning failures, it is necessary to measure and analyze the lightning characteristics. This paper deals with observation of the lightning strokes by KEPCO Lightning Detection Network(KLDNet) and analysis including lightning density, multiplicity and amplitude distribution.

  • PDF

Lightning data detected by Kepco Lightning Detection & information Network in 2006 (한전 낙뢰감지 네트워크(KLDNet)의 2006년도 낙뢰측정 결과)

  • Kwak, J.S.;Woo, J.W.;Kang, Y.W.;Koo, G.S.;Min, B.W.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.691-693
    • /
    • 2007
  • KEPCO, a Korean utility, has been operating a new lightning detection network since 2006. The lightning data detected by the new system named as Kepco Lightning Detection & information Network(KLDNet) is presented, and compared with ten-years-old-statistics accumulated by LPATS in order to look over the detection abilities.

  • PDF

Construction and Operation Characteristics of the Automated Lightning Warning System Based on Detections of Cloud-to-Ground Discharge and Atmospheric Electric Field (낙뢰와 대기전계의 탐지를 기반으로 하는 자동낙뢰경보시스템의 구성과 운용특성)

  • Shim, Hae-Sup;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.11
    • /
    • pp.82-88
    • /
    • 2013
  • It is important to give lightning warning prior to a cloud-to-ground (CG) discharge within an Area of Concern (AOC) because most of lightning damage and victim are usually occurred by the first lightning in the AOC. The aim of this study is to find the optimal operation conditions of the automated lightning warning systems in order to make the best use of the available data. In this paper, the test-operated results of the automated lightning alert and risk management system (ALARM) based on detections of CG discharge and eletrostatic field and optimized at probability of lightning have been described. It was possible to obtain the following warning performance parameters: probability of detection (POD), false alarm ratio (FAR), probability of lightning (POL) and failure-to-warn rate (FTW). The data obtained from trial operation for 5months were not sufficient but the first analysis of domestic lightning warning was carried out. We have observed that the evaluated statistical results through trial operation depend on the various factors such as analysis methods and criteria, topographical conditions, etc. Also we suggest some methods for improvement of POL and POD including the finding of the optimal electric field threshold level to be used, based on the high values of FAR and FTW found in this work.

A Study on the Characteristics of Lightning Detection over the Naro Space Center (나로우주센터 상공의 낙뢰 발생 특성 연구)

  • Kim, Hong-Il;Choi, Eun-Ho;Suh, Sung-Ho;Seo, Seong-Gyu
    • Journal of Environmental Science International
    • /
    • v.31 no.7
    • /
    • pp.543-553
    • /
    • 2022
  • The latest aerospace technology is important for the stable flight of a launch vehicle, but weather conditions on the day of launch are also one of the essential factors for successful launch campaign. If a launch vehicle is directly struck while preparing to take off from the launch pad on the day of launch or the electronic device are damaged by induced current during flight of the launch vehicle, this means launch failure and can lead to enormous national loss. Therefore, for a successful launch campaign, it is necessary to analyze the lightning detection characteristics of the Naro Space Center. In this study, the seasonal factors of the lightning that occurred over the Naro Space Center from 2003 to 2017, the influence of the polarity, and the correlation with the lightning intensity was confirmed. As a result, there was a high probability of intensive occurrence of multiple lightning strikes in summer, and a high proportion of positive (+) lightning strikes in winter. Lastly, in the distribution of the number of lightning strikes, an average of 2.0 to 2.5 negative (-) lightning strikes occurs in the coastal regions of the South and West Seas when one flash happens.

Statistical Characteristics of Recent Lightning Occurred over South Korea (최근 남한지역에서 발생한 낙뢰의 통계적 특성)

  • Eom, Hyo-Sik;Suh, Myoung-Seok
    • Journal of the Korean earth science society
    • /
    • v.30 no.2
    • /
    • pp.210-222
    • /
    • 2009
  • Lightning data, observed from total lightning detection system (TLDS) of KMA, for the recent five years (2002-2006) have been analyzed for temporal and spatial characteristics of frequency, intensity, duration, and flash rate. Lightning frequency varies largely with years (most frequent in 2006) and the lightning during the summer accounts for 75% of total flashes and only 0.6% of lightnings strike in cold season. In rainy season (JJAS), the ratio of positive flashes to negative ones is as low as 0.15, but it increases up to 0.98 in February. The seasonal variation of lightning duration is strongly linked with lightning occurrences, whereas flashes rates show weak seasonal variability. In a daily scale, lightning, on average, occurs more often at dawn (2 am, 5-7 am) and in the mid-afternoon (15 pm), and the lightning at dawn (around 5 am) is most intense during the day. The western inland areas md the West/South Sea show high lightning density during JJAS, whereas eastern part and the East Sea exhibit a low density of lightning. Considering the low ratio of positive flashes (0.15) for the whole analysis domain during summer period, Chungnam and Jeonbuk areas have a high ratio of flashes over 0.4. However, these should be analyzed with much caution because weak positive cloud-to-cloud discharges can be regarded as cloud-to-ground flashes. The western inland also exhibits long annual flash hours (15-24). And the W3st Sea has high flash rates as a result of large density and low flash hours. The most frequent time of lightning occurrence over most inland areas lies between mid-afternoon and early-evening, whereas mountainous and coastal areas, and the northern Kyoungki and Hwanghae provinces show the maximum lightning strikes in the morning and at dawn, respectively.