• Title/Summary/Keyword: Lightings

Search Result 163, Processing Time 0.031 seconds

Research on the Characteristics of the Light Trespass using by RELUX Program According to the Spatial Position of the Road Lightings in Residential Area Near Road (조명시뮬레이션 프로그램(RELUX)을 이용한 도로조명의 공간적 배치에 따른 침입광 영향 특성 연구)

  • Gu, Jinhoi;Jung, Jong-Hwan;Lee, Kyumok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.11
    • /
    • pp.1-8
    • /
    • 2012
  • The road lightings have made our living environment safe and active, since it was first installed in 1900 in Korea. As the industry developed, various kind of road lightings have been installed in an outdoor area. But the spilt light from the road lightings have caused health problem like the sleeplessness, the depression, the failure to thrive and the nearsightedness to children. The light trespass caused by road lightings vary with the height of road lightings, the distance from road lightings to the window and the BUG rating of road lightings. In this paper, we analyze the effect on the light trespass by the spatial installation position of road lightings using by RELUX program. And we derive the characteristics of the light trespass according to the spatial installation position of the road lightings in residential area near road.

Interior heating effect in an office building according to heat properties of light fixture (업무용 건축물의 실내 조명기구 특성에 따른 발열 효과에 관한 연구)

  • Lee, Yoon-Jin;Ahn, Byung-Lip;Kim, Jong-Hun;Jeong, Hak-Geun;Jang, Cheol-Yong;Kim, Tae-Yeon
    • KIEAE Journal
    • /
    • v.15 no.2
    • /
    • pp.117-122
    • /
    • 2015
  • Purpose: Generally, 30% of the total energy consumption in office building is used for artificial indoor lightings, and almost 75-85% of electric power in fluorescent and Light-Emitting Diode (LED) lightings can be dissipated as a form of heat into indoor environment. The heat generated by indoor lightings can cause the increase of cooling load in office buildings. Thus, it its important to consider indoor lightings as a heat and light source, simultaneously. Method: In this study, we installed two kinds of indoor lightings including fluorescent and LED lightings and measured surface temperature of both indoor lightings. In addition, we obtained ambient temperature of indoor space and finally calculated total heat dissipated from plenum area and surface of lightings. Result: Total indoor heat gain was 87.17Wh and 201.36Wh in cases of six 40W-LED lightings and 64W-fluorescent lightings, respectively.

Evaluation of Blue Light Hazards in LED Lightings (LED 조명에 대한 청색광 위험 평가)

  • Jung, Myoung Hoon;Yang, Seok-Jun;Yuk, Ju Sung;Oh, Sang-Young;Kim, Chang-Jin;Lyu, Jungmook;Choi, Eun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.293-300
    • /
    • 2015
  • Purpose: To evaluate blue light hazards of LED lightings in an optical store with blue light radiance used as the quantitative indicators of photobiological hazard. Methods: The spectral radiance of each LED lightings was measured, and blue-light radiance and the corresponding maximum exposure time were calculated. Then each LED lighting was classified according to the risk group from IEC 62471 standard. Results: The yellow LED lightings used in showcases and white LED lightings used on ceilings and logo were classified into risk group RG0. But the white LED lightings used on showcases were classified into risk group RG1. The blue light radiances of white LED lightings used in showcases are dozens of times larger than that of fluorescent lamp. Conclusions: Using the value of the blue light radiance could quantitatively express the blue light hazard to various lightings. It was confirmed that white LED lightings for the showcases had high blue light hazards because of their high luminance and color temperature. Therefore, when replacing lightings in optical shop it is necessary to select the appropriate brightness and color temperature for eye health in the long term.

A study on Utilization of Dancing Light through Zone Lighting of the Indoor Proscenium Stage (실내 프로시니엄 공연무대의 구역 디자인 구역조명을 통한 무용 조명 활용방법에 관한 연구)

  • Lee, Jang-Weon;Han, Me-Hui
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.1
    • /
    • pp.43-53
    • /
    • 2009
  • This study is to investigate the utilization of Indoor Proscenium Stage Zone Lighting method in the dancing performance. In other words, it is about how we can utilize the principle of zone lighting in dancing performance, a kind of stage art. Stage lights give lights on the stage. Therefore they play big and important roles in dancing performances. Lightings make big influence on the overall atvosphere and situations of the dancing work but most of dancers do not perceive their importance and furthermore they don't know about the lightings very well. To let them know about stage lightings better, we studied lightings form the perspective of the dancers who face the lightings without great knowledge thresh the articles and literature related general lightings and lighting design, books related to stage lightings and dancing lightings, previous studies and academic articles. The most important part of this study is to understand and utilize the principle of zone lightiing. Zone lighting is generally called as cross lighting, which means single light from the crossed two lights. When looking into the principle of the zone lighting of the Indoor Proscenium Stage, it means 45 degree lighting from both sides of the top form the point of the dancer When more than two lights are used, the angle of the light should be $90^{\circ}$or 120. It is the principle of the lighting technology showing the face and body of the dancers ing three dimension. Applying for the principle of this zone lighting to the dancing performance of Indoor Proscenium Stage, the lighting methods and the usage of the lightings were studied. As shown above, the role of the lighting is very important in dancing configuration. We hope that the perception on the dancing lighting will be changed and studies on the dancing lightings. By understanding and applying more principles of lighting, we will make efforts to make better dancing performance and dancing conporsers and dancers shall make more efforts and studies on lighting for better works. Through such efforts, we can have more experts and professionals In dancing lighting field and they will help us to describe and express the intention of the dancing work better as dancing artists. We hope that there will be better quality performances through more and diversified studies in this field.

Trend of the National and International Standards for LED Lightings (차세대 LED 조명의 국내외 표준화 동향)

  • Cho, M.R.;Jeon, S.K.;Yang, S.Y.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.141-144
    • /
    • 2009
  • LED Lightings market remains highly fragmented, encompassing many niche applications. Architectural lighting is the largest and many applications are for colored (R, G, B) light. Hundreds of companies worldwide are participating at the luminaire or fixture level. Standard setting is on a fast track. The larger LED lightings market scale, the more important standardization of performance evaluation techniques to clearly prescribe the product specification.

  • PDF

Point Pattern Matching Based Global Localization using Ceiling Vision (천장 조명을 이용한 점 패턴 매칭 기반의 광역적인 위치 추정)

  • Kang, Min-Tae;Sung, Chang-Hun;Roh, Hyun-Chul;Chung, Myung-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1934-1935
    • /
    • 2011
  • In order for a service robot to perform several tasks, basically autonomous navigation technique such as localization, mapping, and path planning is required. The localization (estimation robot's pose) is fundamental ability for service robot to navigate autonomously. In this paper, we propose a new system for point pattern matching based visual global localization using spot lightings in ceiling. The proposed algorithm us suitable for system that demands high accuracy and fast update rate such a guide robot in the exhibition. A single camera looking upward direction (called ceiling vision system) is mounted on the head of the mobile robot and image features such as lightings are detected and tracked through the image sequence. For detecting more spot lightings, we choose wide FOV lens, and inevitably there is serious image distortion. But by applying correction calculation only for the position of spot lightings not whole image pixels, we can decrease the processing time. And then using point pattern matching and least square estimation, finally we can get the precise position and orientation of the mobile robot. Experimental results demonstrate the accuracy and update rate of the proposed algorithm in real environments.

  • PDF

Study on full color RGB LED source lighting for general lighting and Improvement of CRI (Color Rendering Index)

  • Park, Yung-Kyung
    • Science of Emotion and Sensibility
    • /
    • v.15 no.3
    • /
    • pp.381-388
    • /
    • 2012
  • The purpose of this study is to check if LED lighting can be used as general lighting and examine the color rendering property of full color RGB LED lighting. CRI is one of the important properties of evaluating lighting. However the present CRI does not fully evaluate LED lightings. Firstly, the performance of a simple task was compared other than comparing CRI values for different lighting. For experimental preparation three types of lightings were used; standard D65 fluorescent tube, general household fluorescent tube, and RGB LED lighting. All three lightings show high error for Purple-Red. All three lightings show similar error for all hues and prove that color discrimination is not affected by the lighting. This proves that LED could be used as general lighting. Secondly, problems of the conventional CIE CRI method are considered and new models are suggested for the new lighting source. Each of the models was evaluated with visual experiment results obtained by the white light matching experiment. The suggested model is based on the CIE CRI method but replaces the color space model by CIELAB, color difference model by CIEDE2000, and chromatic adaptation model by CAT02.

  • PDF

An Evaluation on Citizens' Satisfaction with the Outdoor Landscape Lighting in Gyeongju Historic Areas - The Case of Wolseong District -

  • Park, So-Yeong;Heo, Sang-Hyun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.38 no.5_2
    • /
    • pp.186-193
    • /
    • 2010
  • The purpose of this study was to survey the citizens for their satisfaction with the outdoor landscape lighting in Gyeongju Historic Areas registered as UNESCO World Cultural Heritage in November 2000 and thereupon, provide for some basic data useful to the design of the outdoor landscape lighting for the cultural properties. As a result of examining the conditions of the outdoor landscape lighting in Wolseong Zone of Anapji, Banwolseong, Dongbu Sajeokji, Cheomseongdae and Gyerim, there were found 391 lighting fixtures of 12 types in Anapji, 138 lightings of 4 types in Banwolseong, 38 lightings of 6 types in Cheomseongdae, 28 lightings of 3 types in Dongbu Sajeokji and 54 lightings of 5 types in Gyerim. As a result of analyzing citizens' satisfaction with the outdoor landscape lighting, it was found that citizens were satisfied more or less with the nightscape image changed by the outdoor landscape lighting; their satisfaction scored 3.836 on average for Anapji on a 5-point Likert type scale, 3.516 for Banwolseong, 3.446 for Dongbu Sajeokji, 3.650 for Cheomseongdae and 3.479 for Gyerim. However, citizens' satisfaction with the originality of the nightscape was generally low: 3.055 for Anapji, 2.914 for Cheomseongdae, 2.877 for Banwolseong, 2.847 for Gyerim and 2.665 for Dongbu Sajeokji. On the other hand, since most of the lighting fixtures were installed as inserted lights or floodlights, the color tones of light source were relatively highly distinctive, but the peripheral spaces around the cultural properties were rather dark, which means that citizens were feeling inconvenient more or less for using the amenities such as bench or waste box. All in all, their satisfaction with the outdoor landscape at the sample zone at night scored 2.981, lower than the normal level.