• Title/Summary/Keyword: Lighting and Cooling Energy

Search Result 89, Processing Time 0.026 seconds

A Study on the Application Ratio by the New and Renewable Energy Systems Fit for Public Medical Facilities (공공의료시설에 적합한 신재생에너지시스템의 복합적용비율에 관한 연구)

  • Hong, Jun-Ho;Lee, Yong-Ho;Cho, Young-Hum;Hwang, Jung-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.2
    • /
    • pp.32-43
    • /
    • 2014
  • This study set out to identify the importance of each factor influencing facility selection with a survey among public medical facilities under the category of public buildings and apply the importance of economy, technology and environment with the weighting factor method, thus proposing optimal application plans. The research content of each section can be summarized as follows:1) Estimated energy consumption according to the energy simulation was 65,129MWh/yr, which was 18.7% higher than that according to the calculation equation. Of the energy consumption, more than 80% was used by heating and cooling facilities and construction facilities, and 20% was used by electronics such as medical equipments and in and outdoor lighting. 2) The results of a survey on the factors influencing the importance when selecting a new and renewable energy system reveal that the upper items had a priority in economy, environment, and technology in the descending order and that the lower item shad a priority in initial investments, maintenance and repair costs=energy costs, supply reliability, energy efficiency and $CO_2$ emissions in the descending order. 3) The application alternatives were analyzed in economy, technology, and environment. As a result, a geothermal system turned out to be the most excellent one a cross all the upper and lower comparison items. Of the other systems, a solar thermal system was superior in initial investments, maintenance and repair costs, and energy efficiency, where as a photovoltaic system was superior in energy costs, supply reliability, and $CO_2$ emissions. 4) As for the mixed application ratio among economy, technology, and environment, when the percentage of a geothermal system was approximately 80% or higher in anew and renewable energy system, it was the best and most optimal application plan.

A study on the Increase in Construction Cost for Zero Energy Building (제로에너지건축물의 공사비 증가분 산출에 관한 연구)

  • Shim, Hong-Souk;Lee, Sungjoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.603-613
    • /
    • 2021
  • As a core policy for achieving the goal of reducing greenhouse gas emissions in the building sector, Korea has enforced the mandatory certification of zero energy buildings for new public buildings from 2020. This study suggests energy-saving technologies and economic factors that building officials can refer to for decision-making on the implementation of zero energy buildings. For this study, the construction cost for the energy item of a building was analyzed by collecting the building energy efficiency level certification data and detailed construction cost statement data from public institutions for the last three years. Based on the building energy efficiency certification data, each energy item of the baseline building was derived, and the energy performance of the zero energy building was derived through repetitive simulations by gradually increasing the energy performance value of the baseline building. By applying the analyzed construction cost, the construction cost for each energy item of the baseline and zero energy buildings was derived. As a result, the lighting equipment contributed up to 10.5% energy savings, and the increase in construction cost of the cooling and heating system was at least 9.1%.

A Study on Development of Independent Low Power IoT Sensor Module for Zero Energy Buildings (제로 에너지 건축물을 위한 자립형 저전력 IoT 센서 모듈 개발에 대한 연구)

  • Kang, Ja-Yoon;Cho, Young-Chan;Kim, Hee-Jun
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.3
    • /
    • pp.273-281
    • /
    • 2019
  • The energy consumed by buildings among the total national energy consumption is more than 10% of the total. For this reason, Korea has adopted the zero energy building policy since 2025, and research on the energy saving technology of buildings has been demanded. Analysis of buildings' energy consumption patterns shows that lighting, heating and cooling energy account for more than 60% of total energy consumption, which is directly related to solar power acquisition and window opening and closing operation. In this paper, we have developed a low - power IoT sensor module for window system to transfer acquired information to building energy management system. This module transmits the external environment and window opening / closing status information to the building energy management system in real time, and constructs the network to actively take energy saving measures. The power used in the module is designed as an independent power source using solar power among the harvest energy. The topology of the power supply is a Buck converter, which is charged at 4V to the lithium ion battery through MPPT control, and the efficiency is about 85.87%. Communication is configured to be able to transmit in real time by applying WiFi. In order to reduce the power consumption of the module, we analyzed the hardware and software aspects and implemented a low power IoT sensor module.

A Study on the Calculation Method of Load standard for ZEB activation (ZEB 활성화를 위한 부하기준 산정 방법 연구)

  • Lee, Hangju;Kim, Insoo
    • Journal of Energy Engineering
    • /
    • v.26 no.4
    • /
    • pp.92-99
    • /
    • 2017
  • In Korea, the zero energy building was designated as the 7 new industries in the Ministry of Land and the 8 new industries in the Ministry of Industry. In order to maximize the insulation performance of the building envelope, improve the efficiency of building equipment, We are aiming. It is necessary to analyze the energy requirements of the buildings (cooling, heating, hot water supply, lighting, ventilation) of buildings with energy efficiency level of 1++ which is equivalent to the zero energy building certification system in Korea, It is aimed to be used as basic data for the advancement of energy building certification system. Zero Energy Building certification is estimated to be 61 buildings by 2017, and the approximate reference value and the first energy requirement for each of the five loads are calculated considering passive and active aspects. It is difficult to say that it is a clear standard because there is a small sample of data for calculating the load standard. However, it is necessary to interpret various methods in order to upgrade the Zero Energy Building certification standard in the future.

Effect of cooling water and inverse lighting on short chain fatty acid and blood lipid of broiler chickens in closed poultry house during hot weather (혹서기 무창계사에서 육계의 혈액지질 및 짧은 사슬지방산에 관한 역전점등과 냉각수 효과)

  • Park, Sang-Oh;Park, Byung-Sung;Hwangbo, Jong;Choi, Hee-Chul
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.31-43
    • /
    • 2014
  • This experiment evaluated the interaction effect of extreme heat diet(EHD), inverse lighting, and cool water on the growth performance of broiler chickens under extreme heat stress. There were 4 experimental groups (T1: EHD 1, 10:00-19:00 dark, 19:00-10:00 light, cold water $9^{\circ}C$; T2: EHD 2, 10:00-19:00 dark, 19:00-10:00 light, cold water $9^{\circ}C$; T3: EHD 1, 09:00-18:00 dark, 18:00-09:00 light, cold water $14^{\circ}C$; T4: EHD 2, 09:00-18:00 dark, 18:00-09:00 light, cold water $14^{\circ}C$), each group composed of 25 broilers and the experiment was repeated 3 times. EHD 1 contained soybean oil, molasses, methionine and lysine. EHD 2 contained all nutrients of EHD 1 and vitamin C additionally. As a result, T1 and T2 displayed higher body weight increase and diet intake compared to T3 and T4 (p<0.05). The weights of their liver and gizzard were similar but the weights of the thymus and bursa F were higher for T1 and T2 compared to that of T3 and T4 (p<0.05). It was observed that T1 and T2 displayed higher concentrations of blood triglyceride, total cholesterol, HDL-C and blood sugar compared to that of T3 and T4 but LDL-C level was higher for T3 and T4 compared to that of T1 and T2 (p<0.05). T1 and T2 displayed higher levels of immunity substances such as IgG, IgA and IgM compared to T3 and T4 but the blood level of corticosterone displayed to be lower for T1 and T2 compared to T3 and T4 (p<0.05). The T1 and T2 contained a higher amount of fecal lactobacillus compared to that of T3 and T4 but the T3 and T4 contained a higher amount of fecal E. coli, total aerobic bacteria, coliform bacteria compared to that of T1 and T2 (p<0.05). T1 and T2 displayed higher concentrations of cecal acetic acid, propionic acid and total short chain fatty acids compared to T3 and T4 but T3 and T4 displayed higher concentrations of butyric acid, isobutyric acid, valeric acid and isovaleric acid compared to T1 and T2 (p<0.05). These results have been observed that broiler chickens exposed to extreme heat stress with feeding EHD, inverse lighting and cold water would improve blood lipid, and elevate the production of immunity substance, beneficial microorganisms, and short chain fatty acids. This provision would also reduce the blood sugar consumption rate as energy sources and these effects will improve the growth performance of the broilers exposed to extreme heat.

Analysis of Energy Balance in Closed Transplants Production System (폐쇄형 묘생산 시스템의 에너지 수지 분석)

  • Kim, J.K.;Kim, Y.H.;Lee, M.G.;Choe, Y.H.
    • Journal of Bio-Environment Control
    • /
    • v.12 no.3
    • /
    • pp.147-152
    • /
    • 2003
  • This study was conducted to analyze the energy balance in closed transplants production system (CTPS) for the production of high quality transplants. Potato (Solanum tuberosum L. cv. Dejima) plug seedlings were grown for 15 days at air temperature of 20$^{\circ}C$, relative humidity of 70%, photoperiod of 16/8 h, and photosynthetic photon flux (PPF) of 200 ${\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ following 5 days of tooting in CTPS. Electric energy consumption was 46% for lighting, 35% for cooling, 16% for heating, 2% for air circulation, and 1% for humidifying. The electric energy utilization efficiency and the short-wave energy utilization efficiency were 0.5% and 5.4%, respectively. These results suggest that CTPS has the feasibility for the commercial production of potato plug seedlings if the electric energy consumption in CTPS is reduced and the electric energy utilization efficiency is increased.

Analysis of CO2 Emission Pattern by Use in Residential Sector (가정 부문 이산화탄소 배출량 추이 분석)

  • Yoon, So Won;Lim, Eun Hyouk;Lee, Gyoung Mi;Hong, You Deok
    • Journal of Climate Change Research
    • /
    • v.1 no.3
    • /
    • pp.189-203
    • /
    • 2010
  • The objective of this study is the estimate of $CO_2$ emissions by the energy consumption of functional technology introduced by classifying energy use in households according to functions as well as energy resources. This study also intends to provide the practical basis data in order to establish specific alternatives for GHG mitigation in residential sector with examining the cause analysis affecting $CO_2$ emission increases from 1995 to 2007. The results of this study show a 6.6% increase in the total $CO_2$ from 60,636 thousand tons in 1995 to 64,611 thousand tons in 2007 by using energy in residential sector. Heating is the greatest $CO_2$ emission sector by use, followed electric appliances, cooking, lighting and cooling. Heating sector shows 56.6% reductions from 71.5% in 1995 and as do cooling and electric home appliances, with a 2.4% increase from 0.6% and a 21.8% increase from 14.2% respectively. To analyze factors resulted in $CO_2$ emissions in residential sector, the relevant indicator change rate from 2005 to 2007 was examined. The results find that population, the number of household, housing areas, family patterns, and family income resulted in the $CO_2$ emissions increase in residential sector from 1995 to 2007. On the other hand, carbon intensity and energy intensity contribute to $CO_2$ reduction in residential sector with -2% and -38.7% respectively because of the energy conversion and the improvement of energy efficiency in electronic appliances. This study can be used as a reference when taken account of the reality and considered the introduction of highly effective measures to increase the possibility of mitigation potential in residential sector hereafter.

Numerical Study on the Thermal Environment of a Natural Light Based Multi-layered Plant Factory (자연광 기반 적층형 식물공장의 열환경에 대한 수치해석 연구)

  • Park, Dong Yoon;Jang, Seong-Teak;Chang, Seong-Ju
    • KIEAE Journal
    • /
    • v.13 no.5
    • /
    • pp.43-50
    • /
    • 2013
  • Recent researches on plant factory system deal with the convergence of lighting technology, agricultural technology inclusive to the high-tech industries worldwide in order to respond to the decreasing crop harvest due to global warming and abnormal weather phenomena. However, the fundamental performance standard is not currently being introduced in the case of plants factory and its commercialization is not activated because of high initial investment and operating cost. Large portion of the initial investment and operating cost of a plant factory is ascribed to artificial light sources and thermal control facilities, therefore, innovation should be provided in order to improve the economics of the plant factory. As an alternative, new plant factory could harness solar thermal and geothermal systems for heating, cooling and ventilation. In this study, a natural light dependent multi-layer plant factory's thermal environment was analyzed with two-dimensional numerical methods to elicit efficient operation conditions for optimized internal physical environment. Depending on the supply air temperature and airflow rate introduced in the facility, the temperature changes around the crops was interpreted. Since the air supplied into the plant factory does not stay long enough, the ambient temperature predicted around the plating trays was not significantly different from that of the supplied air. However, the changes of airflow rate and air flow pattern could cause difference to the temperature around the planting trays. Increasing the amount of time of air staying around the planting trays could improve energy performance in case the thermal environment of a natural light based multi-layer plant factory is considered.

Design and performance estimation of fish-luring system using the water cooling typed LED lamp (채낚기 어선용 수랭식 LED 집어시스템의 설계 및 성능평가)

  • Bae, Bong-Seong;An, Heui-Chun;Kwon, Ki-Jin;Park, Seong-Wook;Park, Chang-Doo;Lee, Kyoung-Hoon
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.47 no.2
    • /
    • pp.79-87
    • /
    • 2011
  • A fishing lamp is fishing gear to gather fish in the night. But the cost of oil which is used to a light fishing lamp, goes significantly up to almost one hundred million won for 50 tonnage vessels and forty million won in case of vessels less than 10 tonnages. This cost has almost taken 30.40% of total fishing costs. As oil price increases, the business condition of the fishery gets worse and worse. Therefore, it is very urgent to develop an economical fishing lamp, to solve the problem of fishery's business difficulty. This research aims at developing a fishing lamp for squid jigging fishery and hairtail angling fishery using the LED, which has excellent efficiency and durability. One fishing lamp has about 160Watt capacity and five fishing lamps are installed one aluminium panel in which sea water flows to emit generated heat from LED to outside. Developed fishing lamp lights to an effective direction of jigging and angling operation. This fishing lamp can be controlled to light the direction of fish shoal because the aluminium panel can be controlled to up and down direction. The wave length of fishing lamp has white and blue color. White color light is to gather fish shoal of horizontal direction and blue color light is to gather fish shoal of vertical direction. After development of this fishing lamp, 60.110 units are established on the boat, and operated fishing. Consequently, in the case of squid jigging, spent energy was reduced to 39%, in the case of hairtail angling, 68% of spent energy was reduced. And the catch was more than another boat.