• 제목/요약/키워드: Light-pipe system

검색결과 86건 처리시간 0.024초

6기통 가솔린 엔진에 장착된 촉매변환기 내의 3차원 비정상 유동특성 해석 (Three Dimensional Unsteady Flow Characteristics inside the Catalytic Converter of 6 Cylinder Gasoline Engine)

  • 정수진;김우승
    • 한국자동차공학회논문집
    • /
    • 제6권4호
    • /
    • pp.108-120
    • /
    • 1998
  • A theoretical study of three-dimensional unsteady compressible non-reacting flow inside double flow of monolith catalytic converter system attached to 6-cylinder engine was performed for the achievement of performance improvement, reduction of light-off time, and longer service life by improving the flow distribution of pulsating exhaust gases. The differences between unsteady and steady-state flow were evaluated through the numerical computations. To obtains the boundary conditions to a numerical analysis, one dimensional non-steady gas dynamic calculation was also performed by using the method of characteristics in intake and exhaust system. Studies indicate that unsteady representation is necessary because pulsation of gas velocity may affect gas flow uniformity within the monolith. The simulation results also show that the level of flow maldistribution in the monolith heavily depends on curvature and angles of separation streamline of mixing pipe that homogenizes the exhaust gas from individual cylinders. It is also found that on dual flow converter systems, there is severe interactions of each pulsating exhaust gas flow and the length of mixing pipe and junction geometry influence greatly on the degree of flow distribution.

  • PDF

물 분사 시스템에 의한 소형 디젤엔진의 NOx 및 그 외 배출물의 특성에 관한 연구 (A Study on the Characteristics of NOx and another Emisson by Water Injection System for a Light-Duty Diesel Engine)

  • 최재성;남정길
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권6호
    • /
    • pp.628-636
    • /
    • 2005
  • In this paper. the effects of a WI(Water Injection) in the intake pipe for a 4-cylinder Dl(Direct Injection) diesel engine are investigated experimentally, The WI system was controlled by the duty cycle from the intake manifold's temperature and MAF(Manifold Air Flow) First. effect of EGR on NOx reduction was investigated. Then WI system was applied to reduce NOx As the results. we can make the NOx map and visualize the NOx results by variation of engine speed and engine load It was known that effect of WI system on NOx reduction without the EGR was better than the with EGR base engine except of low load and speed condition.

A STUDY ON DEGREASING DETERGENT AND METHOD FOR THE IPP TEST FACILITY

  • Kim Yong-Wook;Lee Jung-Ho;Kang Sun-Il;Kim Sang-Heon;Oh Seung-Hyub
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2004년도 한국우주과학회보 제13권2호
    • /
    • pp.262-265
    • /
    • 2004
  • As a cryogen, LOx is a light blue, odorless, transparent liquid. Also it is not shock sensitive and does not decompose. However, it is a strong oxidizer and will vigorously support combustion. Therefore all harmful contaminants (such as grease, oil, fingerprint and organic materials) that could cause malfunctions, fires, or explosions in a oxygen environments must be completely removed prior to the introduction of oxygen. Especially, grease ingredient located inside of the LOx supply line, pipe and PHS (Pneumo-Hydraulic System) part can make drastic chemical reaction with oxygen. Therefore, to protect rapid reaction such as explosion, grease ingredient must be surely eliminated by a regular and irregular degreasing. Study on the availability, effectiveness and selection of degreasing detergents and method is described in this paper, and it will be useful for the construction and management of IPP test facility.

  • PDF

소형 디젤엔진의 NOx 저감을 위한 Urea-SCR 시스템에 관한 연구 (A Study on the Urea-SCR System for NOx Reduction of a light-Duty Diesel Engine)

  • 남정길
    • 한국자동차공학회논문집
    • /
    • 제13권5호
    • /
    • pp.57-63
    • /
    • 2005
  • The effects of an urea injection at the exhaust pipe for a 4-cylinder DI(Direct Injection) diesel engine were investigated with the parameters such as urea-SCR(Selective Catalytic Reduction) and EGR system. The urea quantity was controlled by NOx quantity and MAF(Manifold Air Flow). The urea injection quantity can be controlled with the urea syringe pump, precisely. The effects of NOx reduction for the urea-SCR system were investigated with and without ECR engine, respectively. It was concluded that the SUF(Stoichiometric Urea Flow) is calculated and the NOx results are visualized with engine speed and load. Furthermore, the NOx map is made from this experimental results. It was suggested, therefore, that NOx reduction effects of the urea-SCR system without the EGR engine were better than that with the EGR engine except of low load and low speed.

Build-Up 기법을 이용한 경질유 표준장치의 측정범위 확장 (Flow Range Extension of Light Oil Flowmeter Standard System with Build-Up Technique)

  • 임기원;최종오
    • 대한기계학회논문집B
    • /
    • 제30권12호
    • /
    • pp.1139-1146
    • /
    • 2006
  • Light Oil Flow Standard System(LOFSS) in Korea Research Institute of Standards and Science(KRISS) was designed for oil flowmeter calibration. In order to extend the flow range from 120 $m^3/h$ to 200 $m^3/h$, the build-up technique was applied with two positive displacement flowmeters as master flowmeter. The master flowmeters were calibrated against with LOFSS, which has 0.04 % uncertainty of flow quantity determination, then the test flowmeter is calibrated against two master flowmeters. For uncertainty analysis, the repeatability of master flowmeters, the variation of the fluid density and the pipe volume due to temperature change were scrutinized. The contribution of each uncertainty factors to the calibrator and the correlation of each factors were discussed. For investigating the feasibility of uncertainty analysis, a turbine flowmeter as a transfer package was tested with LOFSS and two reference flowmeter. The hypothesis test for both results was coincide with a 95 % significant level. This means that the uncertainty analysis procedure of the calibrator is reasonable and the extension of flow range with master meters was carry out successfully.

유도초음파를 이용한 3/4″ 배관 결함 검출 연구 (A Study for Flaw Detection of 3/4″ Pipe by Using Guided Wave)

  • 정우근;김진회;천근영
    • 한국압력기기공학회 논문집
    • /
    • 제15권1호
    • /
    • pp.40-45
    • /
    • 2019
  • Unlike the welded pipes in the primary system of light water nuclear power plants being periodically inspected with in-Service inspection program, relatively small pipes with the outer diameter less than 2 inch have not been regularly inspected to date. However, after several failure reports on the occurrence of critical crack-like defects in small pipes, inspection for the small pipes has been more demanded because it could cause the provisional outage of nuclear power plants. Nevertheless, there's no particular method to examine the small pipes having access limitations for inspection due to various reasons; inaccessible area, excessive radiation exposure, hazardous surrounding, and etc. This study is to develop a reliable inspection technique using torsional and flexural modes of guided wave to detect defects that could occur in inaccessible area. The attribute of guided wave that can travel a long distance enables to inspect even isolated range of the pipe from accessible location. This paper presents a case study of the evaluation test on 3/4" small-bore pipes with guide wave method. The test result demonstrates the crack signal behavior and assures possibility to detect the crack signal in a flexural mode, which is clearly distinguishable from the symmetric structure signal in a torsional mode.

레이저 투영 영상 분석에 의한 통신 관로 내벽 검사 기법 (Inspection for Inner Wall Surface of Communication Conduits by Laser Projection Image Analysis)

  • 이대호
    • 한국멀티미디어학회논문지
    • /
    • 제9권9호
    • /
    • pp.1131-1138
    • /
    • 2006
  • 본 논문에서는 지하에 매설된 통신 관로를 레이저 투영 영상 분석에 의해 검사하는 새로운 기법을 제안한다. 레이저 다이오드, 발광 다이오드와 카메라로 구성된 장비가 관내에 직접 투입되며, 레이저 다이오드는 관벽에 투영 영상을 생성하고 발광 다이오드는 내부 조명 장치로 사용되며, 카메라는 관로 영상을 획득한다. 카메라에서 전달된 다양한 조건의 관로 영상에 대해 투영 영역을 정확히 분할하기 위하여, 새로운 객차 모델과 다중 임계치 기법을 이용한다. 분할된 투영 고리의 형상은 최소 직경과 푸리에 표기자에 의해 표현하여 관로의 상태를 규칙에 기반하여 분류한다. 국부적인 최소 직경과 전역적인 푸리에 표기자를 모두 사용하므로 파손된 관로, 찌그러진 관로 등의 다양한 조건에서 높은 분류 성능을 나타낼 수 있으며, 여러 상태의 영상에 대한 실험 결과는 2% 미만의 오분류로 높은 성능을 나타냈다.

  • PDF

자동차 엔진 화재용 자동 소화 시스템 개발에 관한 연구 (A Study On The Development Of An Automatic Fire Extinguishing System For The Engine Compartment Use Of Automobiles)

  • 임성묵;정기창;김홍;강영구;이창섭
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1996년도 학술발표회
    • /
    • pp.57-61
    • /
    • 1996
  • Our goal was to make a cost-effective automatic fire extinguishing system for the engine compartment use of automobiles. We designed this system for the engine compartment. This system consists of 1)foam extinguisher, 2)four nozzles, 3)a pipe arrangement, and 4)an extinguishing device which is equipped with a glass bulb as detector. First and foremost, the extinguishing device was carefully designed to keep the system cost to a minimum. Second, a AFFF foam extinguisher was used because no other fire-fighting agents proved effective against fire in the engine compartment. The AFFF(Aqueous Film Forming Foam) agent which was used in the extinguisher is the 3M company's Light Water. We sought, however, to make other foams by using Halon 1301 and Halon alternatives such as HCFC Blend A, HFC-227ea. We selected these alternatives instead of air in order to raise the expansion ratio of the AFFF agent. By these means we discovered that it is possible to increase the expansion ration of the AFFF agent up to 44:1. We then demonstrated that our automatic fire extinguishing system is the most effective and lowest cost-system yet devised for passenger cars.

  • PDF

고체기준전극 및 원격전위측정 시스템 개발에 관한 연구 (A Study on the Development of Solid Reference Electrode and Remote Protection Potential Measuring System)

  • 류영돈;김진준;김동균
    • 한국가스학회지
    • /
    • 제19권3호
    • /
    • pp.38-43
    • /
    • 2015
  • 지하에 매설된 도시가스 배관은 부식으로부터 보호하기 위하여 전기방식조치를 하도록 하고 있으며, 전기방식시설의 효과적인 유지관리를 위해 1년마다 배관의 전위를 측정 하도록 하고 있다. 방식전위의 측정은 테스트박스(T/B)에서 실시하게 되는데, 도심에 설치된 T/B의 경우 대부분 도로상에 설치되어 있어 전위를 측정할 때 어려움이 있다. 즉, 교통량이 많은 도로에서 전위를 측정하기 위해서는 차량을 통제하거나, 교통량이 적은 심야에 실시해야 하는 등 어려움이 있다. 본 연구에서는 이러한 방식전위 측정의 문제점을 해결하기 위해 고체기준전극 및 무선통신기술을 이용한 원격전위 측정시스템 개발에 관한 연구를 수행하였다. 고체기준 전극을 개발하여 실험실에서 성능테스트를 실시하고, 도시가스 배관이 설치된 현장에 직접 매설하여 전위 값의 변화를 관찰하였다. 또한, 무선통신을 이용하여 측정된 전위값을 서버로 전송하고, 사무실에서 전위값의 변화를 확인하였다. 고체기준전극을 이용한 전위값은 국내에서 사용되고 있는 타사 제품과 큰 차이가 없는 것으로 확인되었으며, 현장에서 측정한 전위 값과 웹서버로 보내진 전위값의 차이는 없었다. 개발된 고체기준전극은 향후 도심에 설치된 테스트 박스의 전위를 차량을 이용하여 측정하는데 사용할 계획이다.

건물 옥상외기와 실내배기를 활용한 풍력발전시스템 적용 연구 (A Study on the Application of a Wind Power Generation System Using Outdoor Air on the Rooftop and Indoor Ventilation)

  • 이용호;박진철;황정하
    • 한국태양에너지학회 논문집
    • /
    • 제34권1호
    • /
    • pp.72-80
    • /
    • 2014
  • This study proposed a wind power generation system utilizing outdoor air on the rooftop and indoor ventilation, which would increase according to the building height, as a way to help to save energy consumption in a building by using wind power energy of the new renewable energy sources. The study measured the distribution of air currents and power generation according to the usage factor of exhaust pipes in the kitchen and bathroom and identified the elements to consider when applying a wind power generation system to buildings in order to use outdoor air on the rooftop increasing according to the height and the indoor ventilation produced in the facility vertical shafts inside the buildings by installing a wind power generation system on the rooftop. (1) The study measured the ventilation velocity of the kitchen hood and bathroom ventilation fan by changing the zone areas by the households according to the usage factor of [${\alpha}$]=33~100%. As a result, the kitchen ventilation pipe generated the ventilation wind of 3.0m/s or more at the usage factor of [${\alpha}$] 66% or higher, and the bathroom ventilation pipe generated ventilation velocity lower than 3.0m/s, the blade velocity of the wind power generator, even after the usage factor rose to [${\alpha}$]=100%. (2) As the old bathroom ventilation pipe generated the ventilation velocity of 3.0m/s, the blade velocity of the wind power generator, even with the rising usage factor [${\alpha}$], the application of an outdoor air induction module increased the ventilation velocity by 2.9m/s at the usage factor of [${\alpha}$]=33%, 3.8m/s at the usage factor of [${\alpha}$]=66%, and 3.6m/s at the usage factor of [${\alpha}$]=100%. Thus the ventilation velocity of 3.0m/s, the blade velocity of the wind power generator, or higher was secured. (3) The findings prove that the applicability of a wind power generation system using outdoor air on the rooftop and indoor ventilation is excellent, which raises a need for various efforts to increase the possibility of its commercialization such as securing its structural stability according to momentary gusts on the rooftop and typhoons in summer and making the structure light to react to the wind directions of outdoor air on the rooftop according to the seasons.