• Title/Summary/Keyword: Light tube

Search Result 356, Processing Time 0.023 seconds

Comparison and Analysis of Zircaloy-4 Tube Wear in Air and Water Environment (수중 및 공기 중에서의 지르칼로이-4 튜브마멸 비교분석)

  • 김형규;박순종;강흥석;윤경호;송기남
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.19-26
    • /
    • 2001
  • The wear characteristic of Zircaloy-4 tube, which is used for a cladding of light water reactor fuel rod, is investigated experimentally. The experiment is conducted with contacting the crossed tube specimens in air as well as in water at room temperature with various combination of contact normal force and sliding distance of reciprocating motion. The contour and the volume of each wear are examined to study the effect of contact condition and environment on wear. As a result, it is found that the wear volume in the water environment is larger than that in the air for all the contact (i.e., force and sliding distance) conditions. However, the wear depth is greater in air than in water if the contact normal force and the sliding distance are larger. These are explained by the ease of detachment of wear particles from the contact surface. On the other hand, workrate model is applied with the contact shear force range measured by our wear tester. Investigated is the correlation between the workrate and the wear volume increase rate of the present experiment. The parabolic curve is found to fit well for the present wear data.

  • PDF

Zn Diffusion using by Ampoule-tube Method into n-type $GaAs_{0.60}P_{0.40}$ and the Properties of Electroluminescence (Ampoule-tube 방식을 이용한 n-type $GaAs_{0.60}P_{0.40}$에 Zn 확산과 전계 발광 특성)

  • Kim, Da-Doo;So, Soo-Jin;Park, Choon-Bae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.08a
    • /
    • pp.59-62
    • /
    • 2003
  • Our Zn diffusion into n-type $GaAs_{0.60}P_{0.40}$ used ampoule-tube method to increase IV. N-type epitaxial wafers were preferred by $H_2SO_4$-based pre-treatment. $SiO_2$ thin film was deposited by PECVD for some wafers. Diffusion times and diffusion temperatures respectability are 1, 2, 3 hr and 775, $805^{\circ}C$. LED chips were fabricated by the diffused wafers at Fab. The peak wavelength of all chips showed about 625~650 nm and red color. The highest IV is about 270 mcd at the diffusion condition of $775^{\circ}C$, 3h for the wafers which didn't deposit $SiO_2$ thin films. Also, the longer diffusion time is the higher IV for the wafers which deposit $SiO_2$ thin films.

  • PDF

A Study on image noise removal of $2^{nd}$ electron detector for a E-Beam Lithography (전자빔 가공기를 위한 2 차 전자 검출기의 영상 노이즈 제거에 관한 연구)

  • Im Y.B.;Moon H.M.;Joe H.T.;Paek Y.J.;Lee C.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1741-1744
    • /
    • 2005
  • The electron beam machining provides very high resolution up to nanometer scale, hence the E-Beam writing technology is rapidly growing in MEMS and nano-engineering areas. For E-Beam machining, $2^{nd}$ electron detector is required to see a machined sample at the stage. The $2^{nd}$ electron detector is composed of scintillator and photomultiplier with signal amplifier and high voltage power supplier. Since a photomultiplier tube is an extremely high-sensitivity photodetector, the signal light level to be detected is very low and therefore particular care must be exercised in shielding external light. In this paper, the design methodology of $2^{nd}$ electron detector and the image noise removal method are introduced.

  • PDF

Electro-Optical Characteristics of an ICP Light Source Depending on Driving Temperature and Length of Discharge Tube (구동 온도와 방전관 길이에 따른 ICP 광원의 전기.광학적 특성)

  • Yim, Youn-Chan;Park, Dae-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.107-113
    • /
    • 2008
  • We investigated the electro-optical characteristics of an ICP(Inductively Coupled Plasma) light source depending on driving temperature, and length of discharge tube. An electro-optical stability of a sample at operating was measured to see a steady state of a sample. In this results, we can see that a stability of power loss and luminous flux of a sample at operating of upper 70[min] was 1.45[%1 and 0.36[%]. We measured the optical characteristics of a sample in a thermal chamber operated at a specific temperature divided into 5 steps. While luminance increased with temperature increasing, the decrement of luminance a eared at u or $46.7[^{\circ}C]$. According to Parchen's and Boyle-Charles' law, we can speculate that a pressure was increased and a higher voltage was needed but a ballaster having a rating power can't support a higher voltage corresponding to a pressure change, 0.02[Torr] at $46.7[^{\circ}C]$. Moreover, we measured an a lied power and current of samples depending to a various length of a discharge tube.

Measurement Technique of Ozone Density by Using UV Sensor System

  • Trung, Nguyen Huu;Van Men, Le;Van Hieu, Nguyen
    • Journal of IKEEE
    • /
    • v.19 no.1
    • /
    • pp.80-86
    • /
    • 2015
  • There are many studies and products using a test paper impregnated with chemical solution can react with ozone. The color of a test paper can indicate the concentration of ozone. The purpose of this research is to design and manufacture a system using ultraviolet light source to measure the ozone density. This new technique is based on the characteristic of decomposition from ozone into oxygen under ultraviolet light. We used two sources of ultraviolet light including UV lamp and UVLED to determine the decomposition of ozone. This system is built with the electronic components, sensors and sealed pump tube to measure the ozone density in units of $g/cm^3$,ppm,ppb. In this paper,, we present some initial results of measuring the ozone density from ozone generator after completing inspection for safety.

A Light-Weight Spring-Driven and Hydraulically-Damped Multiple Piston Corer

  • Lee, Tae-Hee;Go, Sung-Jun;Huh, Sung-Hoi;Lee, Tong-Sup
    • Journal of the korean society of oceanography
    • /
    • v.34 no.3
    • /
    • pp.179-183
    • /
    • 1999
  • A light-weight multiple piston corer to meet increasing coring needs in areas where R/V access is limited, is designed and discussed. Hydraulically-damped and spring-driven piston system not only virtually undisturbed surface sediments but also facilitate the recovery and subsequent operation including pore water extraction and core slicing on board the ship. It is designed as compact, light-weight and easy to dissemble that whole gear can be carried by small passenger vehicle yet it permits thick-walled core tube for thermal insulation or large opening core tubes. Because single spring instead of heavy weights of conventional gravity-driven multiple corers is used, this device is very simple and cheap to construct.

  • PDF

Display Technologies for Immersive Devices and Electronic Skin (디스플레이 현황과 발전방향 -실감 및 스킨 기기로의 확대)

  • Park, Y.J.
    • Electronics and Telecommunications Trends
    • /
    • v.34 no.2
    • /
    • pp.10-18
    • /
    • 2019
  • Since the introduction of CRT(Cathode Ray Tube) in the 1950s, display technologies have been developed continuously. Flat panel displays such as PDP(Plasma Display Panel) and LCD(Liquid Crystal Display) were commercialized in the late 1990s, and OLED(Organic Light Emitting Diodes) and Micro-LED(Micro-Light Emitting Diodes) are now being developed and are becoming widespread. In the future, we expect to develop ultra-realistic, flexible, embedded sensor displays. Ultra-realistic display can be applied to AR/VR(Augmented Reality/Virtual Reality) devices and spatial light modulators for holography. The sensor-embedded display can be applied to robots; electronic skin; and security devices, including iris recognition sensors, fingerprint recognition sensors, and tactile sensors. AR/VR technology must be developed to meet technical requirements such as viewing angle, resolution, and refresh rate. Holography requires optical modulation technology that can significantly improve resolution, viewing angle, and modulation method to enable wide-view and high-quality hologram stereoscopic images. For electronic skin, stable mass production technology, large-area arrays, and system integration technologies should be developed.

EXPERIMENTAL AND ANALYTICAL STUDIES ON THE INSTABILITY IN THE LZCS FOR CANDU REACTORS

  • Ji, Joon-Suk;Lee, Kwang-Ho;Yun, Bum-Su;Cha, Jung-Hun;Kim, Sang-Nyung
    • Nuclear Engineering and Technology
    • /
    • v.40 no.7
    • /
    • pp.561-570
    • /
    • 2008
  • When reactivity insertion such as refueling occurs in CANDU reactors, the power and the water levels are tilted in the upper outer zone of the LZCS (Liquid Zone Control System) and fluctuate unstably for a certain period of time (1-5 days). The instability described above is observed in most CANDU reactors in service around the world, but its root cause is unidentified and no solutions to this problem have been established. Therefore, this study attempted to prove experimentally and analytically that the root cause lies in the hold-up of light water on the top of the TSP (Tube Support Plate) due to the mismatch between net volumetric flow rate of light water and helium crossing the narrowed porous TSP installed within the LZCS compartment. Our method was to perform a hydrodynamic simulation of in/outflow of light water and helium. Two solutions for the aforementioned instability of LZCS are suggested. One is to regulate the compartment for both inflowing helium gas and outflowing light water; the other is to enlarge the flow paths of helium and light water within TSP. The former may be applicable to nuclear reactors in service and the latter to those planned for construction.

A Study on Polynuclear Aromatic Hydrocarbons Emitted by Coking Time and Sampling Method in a Coke Oven Plant (코크스제조공정에서 탄화시간과 시료채취방법에 따른 다핵방향족탄화수소 발생에 관한 연구)

  • Yun, Chung Sik;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.3 no.1
    • /
    • pp.37-53
    • /
    • 1993
  • The polynuclear hydrocarbons (PAHs) emitted from coke oven standpipe were sampled using three sampling systems, including glass fiber filter+silver membrane filter, glass fiber filter+silver membrane filter+XAD-2 adsorbent tube, PTFE membrane filter+XAD-2 adsorbent tube, extracted by methylene chloride and analysed by gas chromathography using flame ionization detector. The results of this study were as follows. 1. Because the amounts of coke oven emissions(COE) were large, the analyses of PAHs were simple and possible without evaporation and concentration. Although the generation of COE was high during early stage of coking, the airborne concentration of PAHs was low and increased during late coking. 2. The contents of PAHs in COE were 1.35-2.81%. 3. The index components of PAHs were fluoranthene and pyrene. Their correlation coefficient to total PAHs were 0.96, 0.95, respectively. 4. The particulate PAHs were sampled by filter and gaseous PAHs by adsorbent tube. The collection efficiency of glass fiber filter+silver membrane filter was 20% of total amount sampled by filters+adsorbent and PTFE membrane filter 50%. Adsorbent tube must be attached to the filter to collect light and small PAH components. 5. The generation of acenaphthene and indeno (1,2,3-cd) pyrene were low and concentrations of fluorene and anthracene were $20-40ug/m^3$ throughout coking time. Other PAH eoncentrations were sometimes high. The generation of PAHs was low at 4-6 hours of coking time. The gaseous PAHs were generated earlier than particulate PAHs.

  • PDF