• Title/Summary/Keyword: Light touch

Search Result 113, Processing Time 0.025 seconds

Large-size LCD with touch-sensing capability

  • Zhu, X.L.;Sit, Cass K.M.;Ma, Mark W.;Feng, Y.J.;Ng, K.W.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1519-1522
    • /
    • 2009
  • We describe a 32" liquid-crystal display (LCD) with multi-touch sensing capability by integrating IR detector arrays onto the LED backlight plate. A transparent light guide is placed in front of the display screen, with IR LEDs disposed at its edges and emitting IR light into the light guide, the light is trapped by total internal reflection within the light guide to be as touch-sensing light. A physical contact with the acrylic plate surface will stimulate some trapped light to be escaped from the light guide and pass through LCD panel to be detected by the IR detectors. The touch-sensing LCD with this configuration can locate simultaneous multiple touche points on the touchable surface.

  • PDF

The effect of balance training combined with light touch on postural sway and walking speed in patients with stroke (가벼운 터치 자극을 이용한 균형훈련이 뇌졸중 환자의 자세동요와 보행속도에 미치는 영향)

  • In, Tae Sung;Jung, Koung Sim
    • Journal of Korean Physical Therapy Science
    • /
    • v.29 no.2
    • /
    • pp.20-27
    • /
    • 2022
  • Background: The purpose of the present study was to determine whether balance training combined with light touch improves the postural sway and gait speed in stroke patients. Design: Randomized Controlled Trial Study Methods: The current study included 40 stroke patients, who were randomly divided into two groups: the balance training with light touch (LT) group (n=20) and the balance training with heavy touch (HT) group (n=20). Both groups performed balance training on a stable and unstable ground. Additionally, the LT group provided light touch stimulation, and the HT group provided heavy touch stimulation. All the participants underwent 20 sessions of STS training (thirty minutes, five days per week for four weeks). In this study, postural sway was measured using a force platform, and walking speed was measured using a 10 meter walk test. Results: The improvements in postural sway and gait speed were observed to be significantly greater in the LT group, compared to the HT group (p<0.05). Conclusion: The results of the current study imply that balance training combined with light touch is a beneficial and effective therapeutic modality that can be employed to improve the postural sway and gait speed in stroke patients.

Effects of the High-Heeled Shoes on the Sensory System and Balance in Women (높은 굽 신발이 감각계의 변화와 균형에 미치는 영향)

  • Kim, Won-Ho;Park, Eun-Young
    • Physical Therapy Korea
    • /
    • v.4 no.2
    • /
    • pp.10-17
    • /
    • 1997
  • The purpose of this study were to compare light touch, two-point discrimination, position sense, and static balance ability and to examine the relationship of static balance ability and different senses in those who are wearing various heights of high-heeled shoes. Each 29 women was classified two different heights (below 3 cm, above 7 cm) by experience in wearing shoes. A t-test was used to determine the differences between low- and high-heeled shoe in light touch, two-point discrimination, position sense, and static balance ability. Pearson correlation was used to examine the relationship of static balance ability to these sensation. The results were as follows: 1) No significant differences in average light touch, position sense between two groups were found(p>0.05). But significant differences in average two-point discrimination, static balance ability were found(p<0.05). 2) Static balance ability was not significantly correlated with light touch, position sense, two-point discrimination(p>0.05). The results suggest that long time experience in wearing high-heeled shoe may be caused local sensory change and decreased static balance ability. Even though, static balance ability was not significantly affected but correlated with two-point discrimination, position sense, and light touch in order.

  • PDF

Highly Stretchable, Transparent Ionic Touch Panel

  • Sun, Jeong-Yun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.51-63
    • /
    • 2017
  • The touch panel was developed decades ago and has become a popular input device in daily life. Because human-computer interaction is becoming more important, the next generation of touch panels require stretchability and bio-compatibility to allow integration with the human body. However, because most touch panels were developed based on stiff, brittle electrodes, electronic touch panels face difficulties to achieve such requirements. In this paper, for the first time, we demonstrate an ionic touch panel based on polyacrylamide hydrogel containing LiCl ions. The panel is soft and stretchable and thus, can sustain a large deformation. The panel can freely transmit light information through it because the hydrogel is transparent, with 99 % transmittance for visible light. A 1-dimensional touch strip was investigated to reveal the basic mechanism of sensing, and a 2-dimensional touch panel was developed to demonstrate its functionalities. The ionic touch panel was operated under high deformation with more than 1000% areal strain without sacrificing its functionalities. Furthermore, an epidermal touch panel on the skin was developed to demonstrate the mechanical and optical invisibility of the ionic touch panel through writing words, playing the piano and playing games.

  • PDF

Effect of light touch on body sway during a stable posture with blocked visual information

  • Kim, Jong-Gun;Kim, Jin-Hong;Do, Kwang-Sun;Yim, Jongeun
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.3
    • /
    • pp.138-142
    • /
    • 2016
  • Objective: The purpose of this study was to investigate how light touch with a finger affects balance ability when a posture is maintained in the condition of visual information blockage and to provide a fundamental material for developing balance ability in the process of rehabilitation treatment. Design: Cross-sectional study. Methods: The study subjects were 17 healthy men and women in their twenties and thirties who were studying at S University in Seoul. The system was comprised of an equilateral triangular force platform. Subjects were asked to step on the foot position of the force platform (Good Balance, Finland) barefooted for 30 seconds, with eyes closed, hands hanging down loosely, and feet comfortably apart. It was connected to a laptop by using Bluetooth technology. An experiment was conducted in the following three circumstances: 1) no-touch trial, 2) light touch to the back (T7 area), and 3) light touch to the middle finger of the left hand. Each subject was given a 10-minute break between consecutive measurements. The experimental circumstances were performed randomly. Anteroposterior sway (APSV), mediolateral sway velocity (MLSV), and velocity moment (VM) were measured. Results: The APSVs (mm/s) were $9.32{\pm}3.37$ and $5.45{\pm}2.98$; the MLSVs (mm/s), $6.39{\pm}3.35$ and $3.31{\pm}2.48$; and VM ($mm^2/s$), $17.13{\pm}11.75$ and $6.76{\pm}8.31$ in the first and second experimental circumstances, respectively. APSV, MLSV, and VM values were significantly improved with the 1) no-touch trial and 2) light touch to the back trail conditions compared with the 3) light touch to the middle finger of the left hand condition (p<0.05). Conclusions: This study revealed that the balance ability for maintaining a body posture was influenced more by light touch to the back (T7) than by light touch with the sensitive fingertip and body sway diminished after visual information was blocked.

Implementation of multi-touching and application based touch interface using Infrared (적외선을 이용한 멀티 터치와 터치 인터페이스의 구현)

  • Yoo, Ki-Sun;Hong, Rok-Ji;Moon, Il-Young
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.6
    • /
    • pp.928-934
    • /
    • 2010
  • In this paper, the method introduce for touching signals and run the application on the multi touch environment using infrared light. When the user touches the screen, the infrared camera make a movie the light and the light which made through image processing communicate from TUIO(Tangble User Interface Object) protocol to Application. this Program is using the delivery informations which are occurred the event to Application. The Application which use the touch can exchange the Andoroid Phone between Mobile picture supervision Application also this equipment introduces about the musical entertainment Application which play a music many users at the same time.

External Light Evasion Method for Large Multi-touch Screens

  • Park, Young-Jin;Lyu, Hong-Kun;Lee, Sang-Kook;Cho, Hui-Sup
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.3 no.4
    • /
    • pp.226-233
    • /
    • 2014
  • This paper presents an external light evasion method that rectifies the problem of misrecognition due to external lighting. The fundamental concept underlying the proposed method involves recognition of the differences between two images and elimination of the desynchronized external light by synchronizing the image sensor and inner light source of the optical touch screen. A range of artificial indoor light sources and natural sunlight are assessed. The proposed system synchronizes with a Vertical Synchronization (VSYNC) signal and the light source drive signal of the image sensor. Therefore, it can display synchronized light of the acquired image through the image sensor and remove external light that is not from the light source. A subtraction operation is used to find the differences and the absolute value of the result is utilized; hence, the order is irrelevant. The resulting image, which displays only a touched blob on the touchscreen, was created after image processing for coordination recognition and was then supplied to a coordination extraction algorithm.

The Effect of Additional Haptic Supplementation on Postural Control During Squat in Normal Adult (추가적인 햅틱적용이 정상 성인의 스쿼트 동안 자세조절에 미치는 영향)

  • Kim, Mi-Ju;Lee, Ho-Cheol;Park, Ji-Won
    • The Journal of Korean Physical Therapy
    • /
    • v.24 no.2
    • /
    • pp.134-142
    • /
    • 2012
  • Purpose: This study examined the effect on postural control during the stimulation of haptic touch with fingertip on the stable surface at quiet standing posture, squat flexion stage, 60 degrees squat stage and squat extension stage. Methods: The postural sway was measured on the force platform, while 30 subjects were squatting, under three different haptic touch conditions (No Touch [NT], Light Touch [LT], Heavy Touch [HT]), above the touch pad in front of their body midline. Three different haptic touch conditions were divided into 1) NT condition; squatting as right index fingers held above the touch pad, 2) LT condition (<1N); squatting as the touch pad was in contact with right index fingers pulp with a pressure not exceeding 1N and 3) HT condition; squatting as subjects were allowed to use the touch pad for mechanical support by transmitting onto it with as much force, choosing with their index fingers. Results: There was significant decrease in LT, rather than that of NT (p<0.01), and in HT, rather than that of LT (p<0.01), as the results of the distance and velocity of center of pressure (COP) in mediolateral direction at quiet standing position. In anteroposterior direction, the distance and velocity of COP in LT and HT showed significant decrease, when compared to that of the data of NT (p<0.01). There was no significant difference between the 3 conditions (NT, LT, and HT), with respect to the distance and velocity of COP in mediolateral direction, during dynamic balance (squat flexion stage, squat extension stage) (p>0.05). In anteroposterior direction, the results of the distance and velocity of COP in HT showed significant decrease when compared to that of the data of NT (p<0.05). Conclusion: Light touch, during the task, decreased the postural sway at static balance. The results suggest that haptic touch should be applied, appropriately, because it varies the effects according to different conditions.

Study on the Touch Screen Panel Based on the Light over Electro Phoretic Display

  • Choi, Uk-Chul;Jung, Ho-Young;Park, Cheol-Woo;Hong, Sung-Jin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.706-709
    • /
    • 2007
  • Different from the LCD that have two glass substrates on the top and the bottom, EPD have an advantage that is using the bottom glass substrate and the top e-ink sheet. So, it is impossible to apply R or C type TSP that need bottom and top glass plane. We successfully implemented the TSP (Touch Screen Panel) based on the light over the EPD (Electro Phoretic Display).

  • PDF

The Effect of Muscular strength, Sensation, and Spasticity of the Hip Joint on Balance in Chronic Stroke Patients (엉덩관절의 근력, 감각과 경직이 만성 뇌졸중 환자의 균형에 미치는 영향)

  • Choi, Yoo-Im;Park, Eun-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.9
    • /
    • pp.4008-4014
    • /
    • 2011
  • The purpose of this study was to identify the effect of muscular strength, sensation, and spasticity of the hip joint on balance using clinical tools in chronic stroke patients. Thirty-two subjects participated. It were measured muscular strength of the hip flexor, extensor, abductor, and adductor using manual muscle testing, light touch sensibility, and spasticity of the quadriceps using the modified Ashworth scale in the paretic lower extremity. Also, static and dynamic balance were measured by the functional balance scale. Collected data was analyzed by stepwise multiple regression. Muscular strength of the hip abductor, light touch sensibility, and spasticity were associated with static balance(p<0.05) and explanatory power was 80.5%. Muscular strength of the hip abductor and light touch sensibility were associated with dynamic balance(p<0.05) and explanatory power was 77.9%. Thus, it is suggested that muscular strength of the hip abductor and light touch sensibility is considered when providing evaluation and intervention programs for the future in the balance.