• Title/Summary/Keyword: Light field imaging

Search Result 130, Processing Time 0.026 seconds

HST/WFPC2 Imaging of the Dwarf Satellites And XI and And XIII : HB Morphology and RR Lyraes

  • Yang, Soung-Chul;Sarajedini, Ata
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.68.1-68.1
    • /
    • 2012
  • We present a comprehensive study of the stellar populations in two faint M31 dwarf satellites, And XI and And XIII. Using deep archival images from the Wide Field Planetary Camera 2 (WFPC2) onboard the Hubble Space Telepscope (HST), we characterize the horizontal branch (HB) morphologies and the RR Lyrae (RRL) populations of these two faint dwarf satellites. Our new template light curve fitting routine (RRFIT) detected RRL populations from both galaxies. The mean periods of $RR_{ab}$ (RR0) stars in And XI and And XIII are < $P_{ab}$ > = $0.621{\pm}0.040$, and < $P_{ab}$ > = $0.648{\pm}0.038$ respectively. Even though the RRL populations show a lack of $RR_{ab}$ stars with high amplitudes (Amp(V) > 1.0 mag) and relatively short periods ($P_{ab}$ ~ 0.5 days), their period - V band amplitude (P-Amp(V)) relations track the lower part of the general P-Amp(V) trend in the M31 outer halo RRL populations. The metallicities of $RR_{ab}$ stars were calculated via the [Fe/H]-log $P_{ab}$-Amp(V) relationship of Alcock et al. The metallicities thus obtained ($[Fe/H]_{And}$ $_{XI}=-1.75%$; $[Fe/H]_{And}$ $_{XIII}=-1.74$) are consistent with the values calculated from the RGB slope indicating that our measurements are not significantly affected by the evolutionary effects of RRL stars. We discuss the origins of And XI and And XIII based on a comparative analysis of the luminosity-metallicity (L-M) relation of Local Group dwarf galaxies.

  • PDF

Analysis of Technology and Research Trends in Biomedical Devices for Measuring EEG during Driving (운전 중 EEG 측정을 위한 생체의료기기의 기술 및 연구동향 분석)

  • Gyunhen Lee;Young-Jin Jung
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1179-1187
    • /
    • 2023
  • Recent advancements in modern transportation have led to the active development of various biomedical signal and medical imaging technologies. Particularly, in the field of cognitive/neuroscience, the importance of electroencephalography (EEG) measurement and the development of accurate EEG measurement technology in moving vehicles represent a challenging area. This study aims to extensively investigate and analyze the trends in technology research utilizing EEG during driving. For this purpose, the Scopus database was used to explore EEG-related research conducted since the year 2000, resulting in the selection of about 40 papers. This paper sheds light on the current trends and future directions in signal processing technology, EEG measurement device development, and in-vehicle driver state monitoring technology. Additionally, a ultra compact 32-channel EEG measurement module was designed. By implementing it simply and measuring and analyzing EEG signals, in-vehicle EEG module's functionality was checked. This research anticipates that the technology for measuring and analyzing biometric signals during driving will contribute to driver care and health monitoring in the era of autonomous vehicles.

IGRINS First Light Instrumental Performance

  • Park, Chan;Yuk, In-Soo;Chun, Moo-Young;Pak, Soojong;Kim, Kang-Min;Pavel, Michael;Lee, Hanshin;Oh, Heeyoung;Jeong, Ueejeong;Sim, Chae Kyung;Lee, Hye-In;Le, Huynh Anh Nguyen;Strubhar, Joseph;Gully-Santiago, Michael;Oh, Jae Sok;Cha, Sang-Mok;Moon, Bongkon;Park, Kwijong;Brooks, Cynthia;Ko, Kyeongyeon;Han, Jeong-Yeol;Nah, Jakyuong;Hill, Peter C.;Lee, Sungho;Barnes, Stuart;Park, Byeong-Gon;T., Daniel
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.52.2-52.2
    • /
    • 2014
  • The Immersion Grating Infrared Spectrometer (IGRINS) is an unprecedentedly minimized infrared cross-dispersed echelle spectrograph with a high-resolution and high-sensitivity optical performance. A silicon immersion grating features the instrument for the first time in this field. IGRINS will cover the entire portion of the wavelength range between 1.45 and $2.45{\mu}m$ accessible from the ground in a single exposure with spectral resolution of 40,000. Individual volume phase holographic (VPH) gratings serve as cross-dispersing elements for separate spectrograph arms covering the H and K bands. On the 2.7m Harlan J. Smith telescope at the McDonald Observatory, the slit size is $1^{\prime\prime}{\times}15^{\prime\prime}$. IGRINS has a $0.27^{\prime\prime}$ pixel-1 plate scale on a $2048{\times}2048$ pixel Teledyne Scientific & Imaging HAWAII-2RG detector with SIDECAR ASIC cryogenic controller. The instrument includes four subsystems; a calibration unit, an input relay optics module, a slit-viewing camera, and nearly identical H and K spectrograph modules. The use of a silicon immersion grating and a compact white pupil design allows the spectrograph collimated beam size to be 25mm, which permits the entire cryogenic system to be contained in a moderately sized rectangular vacuum chamber. The fabrication and assembly of the optical and mechanical hardware components were completed in 2013. In this presentation, we describe the major design characteristics of the instrument and the early performance estimated from the first light commissioning at the McDonald Observatory.

  • PDF

Performance Prediction for Plenoptic Microscopy Under Numerical Aperture Unmatching Conditions (수치 구경 불일치 플렌옵틱 현미경 성능 예측 방안 연구)

  • Ha Neul Yeon;Chan Lee;Seok Gi Han;Jun Ho Lee
    • Korean Journal of Optics and Photonics
    • /
    • v.35 no.1
    • /
    • pp.9-17
    • /
    • 2024
  • A plenoptic optical system for microscopy comprises an objective lens, tube lens, microlens array (MLA), and an image sensor. Numerical aperture (NA) matching between the tube lens and MLA is used for optimal performance. This paper extends performance predictions from NA matching to unmatching cases and introduces a computational technique for plenoptic configurations using optical analysis software. Validation by fabricating and experimenting with two sample systems at 10× and 20× magnifications resulted in predicted spatial resolutions of 12.5 ㎛ and 6.2 ㎛ and depth of field (DOF) values of 530 ㎛ and 88 ㎛, respectively. The simulation showed resolutions of 11.5 ㎛ and 5.8 ㎛, with DOF values of 510 ㎛ and 70 ㎛, while experiments confirmed predictions with resolutions of 11.1 ㎛ and 5.8 ㎛ and DOF values of 470 ㎛ and 70 ㎛. Both formula-based prediction and simulations yielded similar results to experiments that were suitable for system design. However, regarding DOF values, simulations were closer to experimental values in accuracy, recommending reliance on simulation-based predictions before fabrication.

The evaluation for the usability ofthe Varian Standard Couch modelingusing Treatment Planning System (치료계획 시스템을 이용한 Varian Standard Couch 모델링의 유용성 평가)

  • Yang, yong mo;Song, yong min;Kim, jin man;Choi, ji min;Choi, byeung gi
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.77-86
    • /
    • 2016
  • Purpose : When a radiation treatment, there is an attenuation by Carbon Fiber Couch. In this study, we tried to evaluate the usability of the Varian Standard Couch(VSC) by modeling with Treatment Planning System (TPS) Materials and Methods : VSC was scanned by CBCT(Cone Beam Computed Tomography) of the Linac(Clinac IX, VARIAN, USA), following the three conditions of VSC, Side Rail OutGrid(SROG), Side Rail InGrid(SRIG), Side Rail In OutSpine Down Bar(SRIOS). After scan, the data was transferred to TPS and modeled by contouring Side Rail, Side Bar Upper, Side Bar Lower, Spine Down Bar automatically. We scanned the Cheese Phantom(Middelton, USA) using Computed Tomography(Light Speed RT 16, GE, USA) and transfer the data to TPS, and apply VSC modeled previously with TPS to it. Dose was measured at the isocenter of Ion Chamber(A1SL, Standard imaging, USA) in Cheese Phantom using 4 and 10 MV radiation for every $5^{\circ}$ gantry angle in a different filed size($3{\times}3cm^2$, $10{\times}10cm^2$) without any change of MU(=100), and then we compared the calculated dose and measured dose. Also we included dose at the $127^{\circ}$ in SRIG to compare the attenuation by Side Bar Upper. Results : The density of VSC by CBCT in TPS was $0.9g/cm^3$, and in the case of Spine Down Bar, it was $0.7g/cm^3$. The radiation was attenuated by 17.49%, 16.49%, 8.54%, and 7.59% at the Side Rail, Side Bar Upper, Side Bar Lower, and Spine Down Bar. For the accuracy of modeling, calculated dose and measured dose were compared. The average error was 1.13% and the maximum error was 1.98% at the $170^{\circ}beam$ crossing the Spine Down Bar. Conclusion : To evaluate the usability for the VSC modeled by TPS, the maximum error was 1.98% as a result of compassion between calculated dose and measured dose. We found out that VSC modeling helped expect the dose, so we think that it will be helpful for the more accurate treatment.

  • PDF

Review on asbestos analysis (석면 분석방법에 대한 고찰)

  • Ham, Seung hon;Hwang, Sung Ho;Yoon, Chungsik;Park, Donguk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.3
    • /
    • pp.213-232
    • /
    • 2009
  • This document was prepared to review and summarize the analytical methods for airborne and bulk asbestos. Basic principles, shortcomings and advantages for asbestos analytical instruments using phase contrast microscopy(PCM), polarized light microscopy(PLM), X-ray diffractometer (XRD), transmission electron microscopy(TEM), scanning electron microscopy(SEM) were reviewed. Both PCM and PLM are principal instrument for airborne and bulk asbestos analysis, respectively. If needed, analytical electron microscopy is employed to confirm asbestos identification. PCM is used originally for workplace airborne asbestos fiber and its application has been expanded to measure airborne fiber. Shortcoming of PCM is that it cannot differentiate true asbestos from non asbestos fiber form and its low resolution limit ($0.2{\sim}0.25{\mu}m$). The measurement of airborne asbestos fiber can be performed by EPA's Asbestos Hazard Emergency Response Act (AHERA) method, World Health Organization (WHO) method, International Standard Organization (ISO) 10312 method, Japan's Environmental Asbestos Monitoring method, and Standard method of Indoor Air Quality of Korea. The measurement of airborne asbestos fiber in workplace can be performed by National Institute for Occupational Safety and Health (NIOSH) 7400 method, NIOSH 7402 method, Occupational Safety and Health Administration (OSHA) ID-160 method, UK's Health and Safety Executive(HSE) Methods for the determination of hazardous substances (MDHS) 39/4 method and Korea Occupational Safety and Health Agency (KOSHA) CODE-A-1-2004 method of Korea. To analyze the bulk asbestos, stereo microscope (SM) and PLM is required by EPA -600/R-93/116 method. Most bulk asbestos can be identified by SM and PLM but one limitation of PLM is that it can not see very thin fiber (i.e., < $0.25{\mu}m$). Bulk asbestos analytical methods, including EPA-600/M4-82-020, EPA-600/R-93/116, OSHA ID-191, Laboratory approval program of New York were reviewed. Also, analytical methods for asbestos in soil, dust, water were briefly discussed. Analytical electron microscope, a transmission electron microscope equipped with selected area electron diffraction (SAED) and energy dispersive X-ray analyser(EDXA), has been known to be better to identify asbestiform than scanning electron microscope(SEM). Though there is no standard SEM procedures, SEM is known to be more suitable to analyze long, thin fiber and more cost-effective. Field emission scanning electron microscope (FE-SEM) imaging protocol was developed to identify asbestos fiber. Although many asbestos analytical methods are available, there is no method that can be applied to all type of samples. In order to detect asbestos with confidence, all advantages and disadvantages of each instrument and method for given sample should be considered.

Reduction of VOCs and the Antibacterial Effect of a Visible-Light Responsive Polydopamine (PDA) Layer-TiO2 on Glass Fiber Fabric (Polydopamine (PDA)-TiO2 코팅 유리섬유 직물을 이용한 VOCs의 저감 성능 및 항균성 연구)

  • Park, Seo-Hyun;Choi, Yein;Lee, Hong Joo;Park, Chan-gyu
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.6
    • /
    • pp.540-547
    • /
    • 2021
  • Background: Indoor air pollutants are caused by a number of factors, such as coming in from the outside or being generated by internal activities. Typical indoor air pollutants include nitrogen dioxide and carbon monoxide from household items such as heating appliances and volatile organic compounds from building materials. In addition there is carbon dioxide from human breathing and bacteria from speaking, coughing, and sneezing. Objectives: According to recent research results, most indoor air pollution is known to be greatly affected by internal factors such as burning (biomass for cooking) and various pollutants. These pollutants can have a fatal effect on the human body due to a lack of ventilation facilities. Methods: We fabricated a polydopamine (PDA) layer with Ti substrates as a coating on supported glass fiber fabric to enhance its photo-activity. The PDA layer with TiO2 was covalently attached to glass fiber fabric using the drop-casting method. The roughness and functional groups of the surface of the Ti substrate/PDA coated glass fiber fabric were verified through infrared imaging microscopy and field emission scanning electron microscopy (FE-SEM). The obtained hybrid Ti substrate/PDA coated glass fiber fabric was investigated for photocatalytic activity by the removal of ammonia and an epidermal Staphylococcus aureus reduction test with lamp (250 nm, 405 nm wavelength) at 24℃. Results: Antibacterial properties were found to reduce epidermal staphylococcus aureus in the Ti substrate/PDA coated glass fiber fabric under 405 nm after three hours. In addition, the Ti substrate/PDA coated glass fiber fabric of VOC reduction rate for ammonia was 50% under 405 nm after 30 min. Conclusions: An electron-hole pair due to photoexcitation is generated in the PDA layer and transferred to the conduction band of TiO2. This generates a superoxide radical that degrades ammonia and removes epidermal Staphylococcus aureus.

A Comparative Analysis of Keywords in Astronomical Journals and Concepts in Secondary School Astronomy Curriculum (최근 천문학 연구 키워드와 천체 분야 교육과정 내용 요소 비교 분석)

  • Shin, Hyeonjeong;Kwon, Woojin;Ga, Seok-Hyun
    • Journal of The Korean Association For Science Education
    • /
    • v.42 no.2
    • /
    • pp.289-309
    • /
    • 2022
  • In recent years, astronomy has been snowballing: including Higgs particle discovery, black hole imaging, extraterrestrial exploration, and deep space observation. Students are also largely interested in astronomy. The purpose of this study is to discover what needs to be improved in the current astronomy curriculum in light of recent scientists' researches and discoveries. We collected keywords from all papers published from 2011 to 2020 in four selected journals-ApJ, ApJL, A&A, and MNRAS- by R package to examine research trends. The curriculum contents were extracted by synthesizing the in-service teachers' coding results in the 2015 revised curriculum document of six subjects (Science, Integrated Science, Earth Science I, Earth Science II, Physics II, Convergence Science). The research results are as follows: first, keywords that appear steadily in astronomy are 'galaxies: formation, galaxy: active, star: formation, accretion, method: numerical.' Second, astronomy curriculum includes all areas except the 'High Energy Astrophysical Phenomena' area within the common science curriculum learned by all students. Third, it is necessary to review the placement of content elements by subject and grade and to consider introducing new concepts based on astronomy research keywords. This is an exploratory study to compare curriculum and the field of scientific research that forms the basis of the subject. We expect to provide implications for a future revision of the astronomy curriculum as a primary ground investigation.

Analyses of the Setup Errors using on Board Imager (OBI) (On Board Imager (OBI)를 이용한 Setup Error 분석에 대한 연구)

  • Kim, Jong-Deok;Lee, Haeng-O;You, Jae-Man;Ji, Dong-Hwa;Song, Ju-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.1-5
    • /
    • 2007
  • Purpose: The accuracy and advantages of OBI(On Board Imager) against the conventional method like film and EPID for the setup error correction were evaluated with the analysis of the accumulated data which were produced in the process of setup error correction using OBI. Materials and Methods: The results of setup error correction using OBI system were analyzed for the 130 patients who had been planned for 3 dimensional conformal radiation therapy during March 2006 and May 2006. Two kilo voltage images acquired in the orthogonal direction were fused and compared with reference setup images. The setup errors in the direction of vertical, lateral, longitudinal axis were recorded and calculated the distance from the isocenter. The corrected setup error were analyzed according to the lesion and the degree of shift variations. Results: There was no setup error in the 41.5% of total analyzed patients and setup errors between 1mm and 5mm were found in the 52.3%. 6.1% patients showed the more than 5mm shift and this error were verified as a difference of setup position and the movement of patient in a treatment room. Conclusion: The setup error analysis using OBI in this study verified that the conventional setup process in accordance with the laser and field light was not enough to get rid of the setup error. The KV images acquired using OBI provided good image quality for comparing with simulation images and much lower patients' exposure dose compared with conventional method of using EPID. These advantages of OBI system which were confirmed in this study proved the accuracy and priority of OBI system in the process of IGRT(Image Guided Radiation Therapy).

  • PDF

A Study on Metaverse Construction Based on 3D Spatial Information of Convergence Sensors using Unreal Engine 5 (언리얼 엔진 5를 활용한 융복합센서의 3D 공간정보기반 메타버스 구축 연구)

  • Oh, Seong-Jong;Kim, Dal-Joo;Lee, Yong-Chang
    • Journal of Cadastre & Land InformatiX
    • /
    • v.52 no.2
    • /
    • pp.171-187
    • /
    • 2022
  • Recently, the demand and development for non-face-to-face services are rapidly progressing due to the pandemic caused by the COVID-19, and attention is focused on the metaverse at the center. Entering the era of the 4th industrial revolution, Metaverse, which means a world beyond virtual and reality, combines various sensing technologies and 3D reconstruction technologies to provide various information and services to users easily and quickly. In particular, due to the miniaturization and economic increase of convergence sensors such as unmanned aerial vehicle(UAV) capable of high-resolution imaging and high-precision LiDAR(Light Detection and Ranging) sensors, research on digital-Twin is actively underway to create and simulate real-life twins. In addition, Game engines in the field of computer graphics are developing into metaverse engines by expanding strong 3D graphics reconstuction and simulation based on dynamic operations. This study constructed a mirror-world type metaverse that reflects real-world coordinate-based reality using Unreal Engine 5, a recently announced metaverse engine, with accurate 3D spatial information data of convergence sensors based on unmanned aerial system(UAS) and LiDAR. and then, spatial information contents and simulations for users were produced based on various public data to verify the accuracy of reconstruction, and through this, it was possible to confirm the construction of a more realistic and highly utilizable metaverse. In addition, when constructing a metaverse that users can intuitively and easily access through the unreal engine, various contents utilization and effectiveness could be confirmed through coordinate-based 3D spatial information with high reproducibility.