• Title/Summary/Keyword: Light field imaging

Search Result 131, Processing Time 0.026 seconds

A Study in the Crimes of the Medical Practice without License - Case of Oriental Medicine's use of Ultrasounds - (무면허의료행위에 대한 형사법적 쟁점 - 한의사의 초음파기기 사용을 중심으로 -)

  • Jang, Jun Hyuk
    • The Korean Society of Law and Medicine
    • /
    • v.15 no.1
    • /
    • pp.35-57
    • /
    • 2014
  • Recently, there has been fierce argument between oriental and western doctors in the medical field. The use of medical devices has particularly come to the fore lately. Appropriate medical devices are required to diagnose and treat patients' conditions or illnesses accurately. At issue recently in medical device sector are diagnostic instruments using radiation, magnetic resonance imaging, ultrasound, IPL(Intense Pulse Light), and instruments used for tonometry. Relating to this issue, Association of Korean Oriental Medicine and The Association of Korean Medicine are sharply opposed. It is predicted that more accusations of this kind will be seen in the future. As oriental medicine contends, ultrasonic imaging itself seems to cause no harm to humans and its use may have an advantage for national health. The use of western diagnostic equipment can expand the diagnostic range of oriental doctors. However, unless new legislation is made, it is against the law for oriental doctors to use this equipment. Both law and medical science require grounds and predictability on the correctness of a decision and all of its consequences. Additionally, oriental medicine's use of ultrasounds and other medical devices should be established by standards and grounds which make same the diagnosis with repetition. Therefore, the scope of oriental medicine can be expanded following a revision of the Oriental Medicine Promotion Act and it is estimated that the state of national health will be greatly improved by the mutual respect of both sides of the health profession.

  • PDF

Machine learning based radar imaging algorithm for drone detection and classification (드론 탐지 및 분류를 위한 레이다 영상 기계학습 활용)

  • Moon, Min-Jung;Lee, Woo-Kyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.5
    • /
    • pp.619-627
    • /
    • 2021
  • Recent advance in low cost and light-weight drones has extended their application areas in both military and private sectors. Accordingly surveillance program against unfriendly drones has become an important issue. Drone detection and classification technique has long been emphasized in order to prevent attacks or accidents by commercial drones in urban areas. Most commercial drones have small sizes and low reflection and hence typical sensors that use acoustic, infrared, or radar signals exhibit limited performances. Recently, artificial intelligence algorithm has been actively exploited to enhance radar image identification performance. In this paper, we adopt machined learning algorithm for high resolution radar imaging in drone detection and classification applications. For this purpose, simulation is carried out against commercial drone models and compared with experimental data obtained through high resolution radar field test.

Assessment and Comparison of Three Dimensional Exoscopes for Near-Infrared Fluorescence-Guided Surgery Using Second-Window Indocyanine-Green

  • Cho, Steve S.;Teng, Clare W.;Ravin, Emma De;Singh, Yash B.;Lee, John Y.K.
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.4
    • /
    • pp.572-581
    • /
    • 2022
  • Objective : Compared to microscopes, exoscopes have advantages in field-depth, ergonomics, and educational value. Exoscopes are especially well-poised for adaptation into fluorescence-guided surgery (FGS) due to their excitation source, light path, and image processing capabilities. We evaluated the feasibility of near-infrared FGS using a 3-dimensional (3D), 4 K exoscope with near-infrared fluorescence imaging capability. We then compared it to the most sensitive, commercially-available near-infrared exoscope system (3D and 960 p). In-vitro and intraoperative comparisons were performed. Methods : Serial dilutions of indocyanine-green (1-2000 ㎍/mL) were imaged with the 3D, 4 K Olympus Orbeye (system 1) and the 3D, 960 p VisionSense Iridium (system 2). Near-infrared sensitivity was calculated using signal-to-background ratios (SBRs). In addition, three patients with brain tumors were administered indocyanine-green and imaged with system 1, with two also imaged with system 2 for comparison. Results : Systems 1 and 2 detected near-infrared fluorescence from indocyanine green concentrations of >250 ㎍/L and >31.3 ㎍/L, respectively. Intraoperatively, system 1 visualized strong near-infrared fluorescence from two, strongly gadolinium-enhancing meningiomas (SBR=2.4, 1.7). The high-resolution, bright images were sufficient for the surgeon to appreciate the underlying anatomy in the near-infrared mode. However, system 1 was not able to visualize fluorescence from a weakly-enhancing intraparenchymal metastasis. In contrast, system 2 successfully visualized both the meningioma and the metastasis but lacked high resolution stereopsis. Conclusion : Three-dimensional exoscope systems provide an alternative visualization platform for both standard microsurgery and near-infrared fluorescent guided surgery. However, when tumor fluorescence is weak (i.e., low fluorophore uptake, deep tumors), highly sensitive near-infrared visualization systems may be required.

The luminescence properties of Eu3+ or Tb 3+ doped Lu2Gd1Ga2Al3O12 phosphors for X-ray imaging

  • M.J. Oh;Sudipta Saha;H.J. Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4642-4646
    • /
    • 2023
  • The Tb3+ or Eu3+-doped Lu2Gd1Ga2Al3O12 phosphor were fabricated by funace at 1500 ℃ for 12 h using a solid state reaction. The XRD (X-ray diffraction_Panalytical X'Pert Pro) and FE-SEM (field emission scanning electron microscope) are measured to confirm the crystalline structure and surface morphology of the phosphor. The Tb3+-doped Lu2Gd1Ga2Al3O12 phosphor emits the lights in 470~650 nm wavelength range due to transitions from 5D4 to 7Fj. Therefore, it shows the green region in the CIE chromaticity diagram under both UV and X-rays excitations. The Eu3+-doped Lu2Gd1Ga2Al3O12 phosphor emits the lights in 550~750 nm wavelength range because of 5Di to 7Fj. The emission is confirmed to be in the red region using the CIE chromaticity diagram. The Tb3+ or Eu3+-doped Lu2Gd1Ga2Al3O12 phosphor shows the characteristic f-f transition with a long decay time, which is about several milliseconds. They have the high efficiency of light emission for X-ray because of their high effective Z number (Zeff = 58.5) and density. Therefore, they are very much promising phosphors for X-ray imaging application in medical fields.

Acquisition of High Resolution Images and its Application using Synchrotron Radiation Imaging System (방사광 X-선을 이용한 고해상도 영상획득과 응용)

  • 홍순일;김희중;정해조;홍진오;정하규;김동욱;제정호;김보라;유형식
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.51-58
    • /
    • 2001
  • Synchrotron radiation (SR) has several advantages over convetional x-rays, including its phase, collimation, and high flux. A synchrotron radiation beamline 5C1 at Pohang Light Source (PLS) was recently built for imaging applications. We have shown that a SR imaging system is useful in imaging microscopic structures. SR with broad-band energy spectrum were adjusted to an object by Si wafers and their energy were approximately ranging from 6 keV to 30 keV. SR were passed through an object and finally transformed into visible lights by CdWO$_4$ scintillator screen. The visible lights which were reflected at an angle of 90 degrees by gold plated mirror were detected by a CCD camera and the image data were acquired using image acquisition system. A high-resolution phantom, capacitor, adult tooth, child tooth, cancerous breast tissue, and mouse lumbar vertebra were imaged with SR imaging system. The Objects were rotated within the field of view of the CCD detector, and their projection image data were obtained at 250 steps over 180 degrees rotation. Image reconstructions were carried out in a PC by using IDLTM(Research systems, Inc., US) program. The spatial resolution of the images acquired by the SR imaging system was measured with a high-resolution chart manufactured for several micrometer resolution. The specimens were also imaged with conventional x-ray radiography system to compare the image quality of radiography obtained with the SR imaging system. The results showed more structural details and high contrast images with SR imaging system than conventional x-ray radiography system. The SR imaging system may have a potential for imaging in biological researches, material applications, and clinical radiography.

  • PDF

The Zodiacal Light Observations with the MIRIS

  • Pyo, Jeong-Hyun;Jeong, Woong-Seob;Matsumoto, Toshio;Lee, Dae-Hee;Han, Won-Yong;Ree, Chang-Hee;Park, Young-Sik;Nam, Uk-Won;Moon, Bong-Kon;Park, Sung-Joon;Cha, Sang-Mok;Lee, Sung-Ho;Yuk, In-Soo;Park, Jang-Hyun;Jin, Ho;Lee, Duk-Hang;Lee, Hyung-Mok;Hong, Seung-Soo
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.1
    • /
    • pp.42.1-42.1
    • /
    • 2011
  • The main payload of the Science and Technology Satellite 3 (STSAT-3), Multipurpose Infrared Imaging System (MIRIS), will be equipped with the wide-field near-infrared camera. Its wide field-of-view ($3.67^{\circ}{\times}3.67^{\circ}$) is optimal for the observation of the zodiacal light (ZL), the sunlight scattered by the interplanetary dust (IPD). The MIRIS will continuously monitor the seasonal variation of the ZL towards both north and south ecliptic poles, which is caused by the asymmetries of the IPD distribution with respect to the Sun and the ecliptic plane. In addition to the monitoring observations, we are planning pointed observations for compelling structures in the ZL, the asteroidal dust bands and the gegenschein. This presentation proposes the zodiacal light observations with the MIRIS and discusses the expected results.

  • PDF

A of Radiation Field with a Developed EPID

  • Y.H. Ji;Lee, D.H.;Lee, D.H.;Y.K. Oh;Kim, Y.J.;C.K. Cho;Kim, M.S.;H.J. Yoo;K.M. Yang
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.67-67
    • /
    • 2003
  • It is crucial to minimize setup errors of a cancer treatment machine using a high energy and to perform precise radiation therapy. Usually, port film has been used for verifying errors. The Korea Cancer Center Hospital (KCCH) has manufactured digital electronic portal imaging device (EPID) system to verify treatment machine errors as a Quality Assurance (Q.A) tool. This EPID was consisted of a metal/fluorescent screen, 45$^{\circ}$ mirror, a camera and an image grabber and could display the portal image with near real time KIRAMS has also made the acrylic phantom that has lead line of 1mm width for ligh/radiation field congruence verification and reference points phantom for using as an isocenter on portal image. We acquired portal images of 10$\times$10cm field size with this phantom by EPID and portal film rotating treatment head by 0.3$^{\circ}$, 0.6$^{\circ}$ and 0.9$^{\circ}$. To check field size, we acquired portal images with 18$\times$18cm, 19$\times$19cm and 20$\times$20cm field size with collimator angle 0$^{\circ}$ and 0.5$^{\circ}$ individually. We have performed Flatness comparison by displaying the line intensity from EPID and film images. The 0.6$^{\circ}$ shift of collimator angle was easily observed by edge detection of irradiated field size on EPID image. To the extent of one pixel (0.76mm) difference could be detected. We also have measured field size by finding optimal threshold value, finding isocenter, finding field edge and gauging distance between isocenter and edge. This EPID system could be used as a Q.A tool for checking field size, light/radiation congruence and flatness with a developed video based EPID.

  • PDF

On-line Quality Assurance of Linear Accelerator with Electronic Portal Imaging System (전자포탈영상장치(EPID)를 이용한 선형가속기의 기하학적 QC/QA System)

  • Lee, Seok;Jang, Hye-Sook;Choi, Eun-Kyung;Kwon, Soo-Il;Lee, Byung-Yong
    • Progress in Medical Physics
    • /
    • v.9 no.3
    • /
    • pp.127-136
    • /
    • 1998
  • On-line geometrical quality assurance system has been developed using electronic portal imaging system(OQuE). EPID system is networked into Pentium PC in order to transmit the acquisited images to analysis PC. Geometrical QA parameters, including light-radiation field congruence, collimator rotation axis, and gantry rotation axis can be easily analyzed with the help of graphic user interface(GUI) software. Equipped with the EPID (Portal Vision, Varian, USA), geometrical quality assurance of a linear accelerator (CL/2100/CD, Varian, USA), which is networked into OQuE, was performed to evaluate this system. Light-radiation field congruence tests by center of gravity analysis shows 0.2~0.3mm differences for various field sizes. Collimator (or Gantry) rotation axis for various angles could be obtained by superposing 4 shots of angles. The radius of collimator rotation axis is measured to 0.2mm for upper jaw collimator, and 0.1mm for lower jaw. Acquisited images for various gantry angles were rotated according to the gantry angle and actual center of image point obtained from collimator axis test. The rotated images are superpositioned and analyzed as the same method as collimator rotation axis. The radius of gantry rotation axis is calculated 0.3mm for anterior/posterior direction (gantry 0$^{\circ}$ and 170$^{\circ}$) and 0.7mm for right/left direction(gantry 90$^{\circ}$ and 260$^{\circ}$). Image acquisition for data analysis is faster than conventional method and the results turn out to be excellent for the development goal and accurate within a milimeter range. The OQuE system is proven to be a good tool for the geometrical quality assurance of linear accelerator using EPID.

  • PDF

Optical Design and Tolerance Analysis for UVO-Multiband Polarizing Imager System

  • Han, Jimin;Chang, Seunghyuk;Park, Woojin;Lee, Sunwoo;Ahn, Hojae;Kim, Geon Hee;Lee, Dae-Hee;Pak, Soojong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.45 no.1
    • /
    • pp.68.2-68.2
    • /
    • 2020
  • UVO-Multiband Polarizing Imager System (UVOMPIS) is an ultraviolet to visible light multi-wavelength polarization/imaging system for Compact Advanced Satellite. We developed Linear Astigmatism Free-Three Mirror System (LAF-TMS) D200F2 as an optical system of UVOMPIS which has an entrance pupil diameter of 200 mm, a focal ratio of 2, a field of view of 2° × 4°. LAF-TMS is a confocal off-axis reflecting telescope system that removes linear astigmatism, and its all mirrors (M1, M2, M3) are optimized with the freeform surface to reduce high-order aberrations. Through the sensitivity analysis and Monte-Carlo simulation as the tolerance analysis, we can confirm the feasibility of the system, relatively sensitive parameters (tilt, decenter, despace, surface RMS error), and considerations for optomechanical design. From the sensitivity analysis, we can discover the relatively sensitive optical alignment parameters to a single perturbation. Further more, in the monte-carlo simulation, we investigate the minimum tolerance budget satisfying the required optical performance and whether the tolerance range is satisfied within manufacturing error.

  • PDF

Stellar photometric Properties in the outskirt of NGC 5236

  • Kim, Sanghyun;Kim, Minjin;Byun, Woowon;Sheen, Yun-Kyeong;Ho, Luis C;Lee, Joon Hyeop;Kim, Sang Chul;Jeong, Hyunjin;Park, Byeong-Gon;Seon, Kwang-Il
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.45 no.1
    • /
    • pp.60.2-60.2
    • /
    • 2020
  • In the hierarchical framework, galaxies grow through mergers and accretion. Those mechanisms leave faint features, such as stellar streams, shells and smooth stellar halos in the outskirts of galaxies. In order to search for those features in the nearby galaxies, we are conducting a KMTNet Nearby Galaxy Survey using the Korea Microlensing Telescope Network. We present a deep and wide-field imaging of NGC 5236, a barred spiral galaxy. In one-dimensional surface brightness profiles, we reach 28, 29 mag/arcsec2 in the R- and B-band, respectively. We find that the outer disk of NGC 5236 can be well described with a single exponential profile up to 17 kpc (~3.8 Reff) indicating that the excess light due to the stellar halo is not clearly detected. B-R color gradually increases towards the outskirts of the galaxy. It may reveal that stellar properties in the outskirts are marginally distinctive from those in the central part.

  • PDF