• Title/Summary/Keyword: Light emitting diode irradiation

Search Result 78, Processing Time 0.023 seconds

Realization of Static Image on OLEO using Photoluminescence Degradation (PL Degradation을 활용한 OLED 소자의 사진 이미지 구현)

  • Suh, Won-Gyu;Moon, Dae-Gyu
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.9
    • /
    • pp.859-862
    • /
    • 2008
  • We have realized static image on organic light emitting diodes (OLEDs) using photoluminescence degradation. Ultraviolet (UV) was irradiated to the glass side of device. UV power was 350 Wand the wavelength was 365 nm. The UV irradiation gives rise to the degradation of photoluminescence. Due to the degradation, the current density-voltage curve was shifted to the higher voltage side and the luminescence was also degraded by the current and photoluminescence drop. The negative imaged films were prepared to control the transmittance of UV. The UV light was passed through the film. By this method, the film image was transferred to the device with reversed image and the static image was realized on the OLED.

The effect of 470nm LED Irradiation on skin injury of RAT (470nm LED 광이 RAT 피부결손에 미치는 효과)

  • Cheon, Min-Woo;Kim, Seong-Hwan;Park, Yong-Pil;Lee, Ho-Shik;Kim, Young-Pyo;Kim, Tae-Gon;Lee, Hee-Keb
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.416-417
    • /
    • 2008
  • This paper performed the basic study for developing the Photodynamic Therapy Equipment for medical treatment. We developed the 4channel light medical therapy apparatus for external injury cure using a LED light source. This equipment was fabricated by using microcontroller, and designed to enable us to control light irradiation timer, intensity and reservation. In this paper, the designed device was used to find out how 470nm LEDs light source affects the skin wound of RAT. In the experiment, $1cm_2$ wounds on the External injury of RAT were made. Light irradiation RAT and none light irradiation RAT divided, each RAT was irradiated one hour a day for 15 days. In result, compared with none light irradiation RAT, the lower incidence of inflammation and faster recovery was shown in light irradiation RAT.

  • PDF

Wound Recovery of Light Irradiation by White LED (백색 LED 조사의 상처 수복 효과)

  • Cheon, Min-Woo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.1
    • /
    • pp.42-46
    • /
    • 2011
  • Light can be divided into ultraviolet rays, visible rays, and infrared rays depending on the wavelengths. Visible rays with specific wavelength are those predominantly used for would treatment. Especially low level laser irradiates into cells, effectively stimulating cellular tissues and activating cellular function. This study was intended to verify the effect of white LED irradiation therapy on wound recovery in animal tests by applying white LED irradiator, which was independently designed and developed to emit beams of similar wavelength to that of a laser. The designed LED Irradiator was used to find out how white LED light source affected the skin wound of SD-Rat(Sprague-Dawley Rat). We divided the participants into two groups; white LED irradiation group which was irradiated 1 hour a day for 9 consecutive days, and none irradiation group. The results showed that the study group had lower incidence of inflammation and faster recovery, compared with the control group.

Wound Healing Effect of 525 nm Green LED Irradiation on Skin Wounds of Male Sprague Dawley Rats

  • Cheon, Min-Woo;Park, Yong-Pil
    • Transactions on Electrical and Electronic Materials
    • /
    • v.11 no.5
    • /
    • pp.226-229
    • /
    • 2010
  • Many methods exist that promote wound healing, including light therapy, which consists of light beams that assist the human body in treating and sterilizing wounds, as well as regenerating cells. Irradiation with specific wavelengths of either laser or LED light has been shown to induce beneficial proliferation of fibroblasts that, depending on the size of the wound, can be effective in promoting wound healing. The experiments in this study utilized 8 week old 250~300 g Male Sprague Dawley Rats (ILAR Code: NTacSam:SD) and included a non-irradiation group and a 525 nm green LED irradiation group (n of each group = 7). In experiments animals were allowed to rest for 24 hours after wounds had been excised, which was followed by non- irradiation or 525 nm green LED irradiation therapy one hour per day for 9 days. Immunohistochemical staining was conducted for cytokeratin in order to precisely measure the defect size. In addition, Masson's trichrome staining was utilized in order to compare levels of collagen between the 525 nm green LED irradiation group and the non-irradiation group. Animals exposed to 525 nm green LED irradiation (p<0.05) healed at a faster rate and had increased collagenosis compared with the non-irradiated control group. Thus, treatment with 525 nm green LED irradiation had a beneficial effect on wound healing and should be considered as a possible alternative to low power laser treatment.

Effect of Light Emitting Diode and Fluorescent Light on Volatile Profiles of Soybean Oil during Storage (콩기름 저장 중 휘발성분에 대한 LED와 형광등 광원 조사의 영향)

  • Park, In-Seon;Choi, Duck-Joo;Youn, Aye-Ree;Lee, Youn-Jung;Kim, Youn-Kyeong;Kim, Mun-Ho;Choi, So-Rye;Kim, Ki Hwa;Dong, Hyemin;Han, Hyun Jung;Noh, Bong Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.6
    • /
    • pp.763-769
    • /
    • 2013
  • Soybean oil was stored in polyethylene for 12 weeks at $20^{\circ}C$. The influence of LED (light emitting diode) irradiation on four different wavelengths and fluorescent light was investigated. The pattern changes of volatile components in soybean oil was analyzed by electronic nose based on mass spectrometer. The obtained data from electronic nose were analyzed by discrimination function analysis. Under fluorescent light, the discriminant function first score (DF1) was significantly moved from positive position to negative one after 4-12 weeks. It means that the volatile compounds related to quality of lipid. It was shown to increase slowly due to green light of LED treatment, while blue and white LED light was influenced significantly as well as fluorescent light irradiation. Selection of LED irradiation would provide to keep good quality of soybean oil under distribution chain system.

In-office dental bleaching with violet light emitting diode: bleaching efficacy and pulpal temperature rise

  • Brunna Katyuscia de Almeida Guanaes;Talyta Neves Duarte;Gisele Maria Correr;Marina da Rosa Kaizer;Carla Castiglia Gonzaga
    • Restorative Dentistry and Endodontics
    • /
    • v.47 no.1
    • /
    • pp.7.1-7.14
    • /
    • 2022
  • Objectives: This study evaluated the bleaching efficacy of different in-office protocols associated with violet light emitting diode (V-LED), and measured the pulpal temperature rise caused by V-LED with or without gel application. Materials and Methods: Bovine incisors were distributed in 4 groups (n = 10): VL - V-LED; HP - 35% hydrogen peroxide (control); HYB - hybrid protocol, V-LED applied without gel for 10 irradiation cycles followed by V-LED applied with gel for another 10 irradiation cycles; and HPVL - gel and V-LED applied for 20 irradiation cycles. Three bleaching sessions were performed with 7-day intervals. Bleaching efficacy was evaluated with ΔEab*, ΔE00 and ΔWID. Data were recorded at baseline, 7, 14, 21 and 70 days. For pulpal temperature rise, thermocouples were placed inside the pulp chamber of human incisors. To determine intrapulpal temperature, the teeth were irradiated with V-LED with or without application of bleaching gel. Color difference data were analyzed by 2-way repeated measures ANOVA and Tukey's test. Pulpal temperature was analyzed by t-test (α = 5%). Results: VL exhibited lower color (ΔEab* and ΔE00) and whiteness changes (ΔWID) than the other groups. HPVL presented higher color change values than HYB. HYB and HPVL showed not different ΔWID values; and HP showed the highest whiteness changes at all times. There were significant differences comparing ΔT with gel (8.9℃) and without gel application (7.2℃). Conclusions: HPLV was more efficient than HYB. The 2 protocols with VL showed similar results to control. Gel application combined with VL promoted higher pulpal temperature than to the no gel group.

4-channel Light Medical Therapy Apparatus for External Injury Cure (체외 상처 치유를 위한 4-채널 광 치료기)

  • Cheon, Min-Woo;Kim, Seong-Hwan;So, Keum-Young;Moon, Young-Lae;Mun, Seong-Pyo;Park, Yong-Pil;Lee, Ho-Sik;Kim, Tae-Gon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.8
    • /
    • pp.731-735
    • /
    • 2007
  • We developed the 4channel Light Medical Therapy Apparatus for External Injury Cure using a high brightness LED. This equipment was fabricated using a micro-controller and a high brightness LED, and designed to enable us to control light irradiation time, intensity, frequency and so on, Especially, to control the light irradiation frequency, FPGA was used, and to control the change of output value, TLC5941 was used. Control stage is divided into 4 levels by program. Consequently, the current value could be controlled by the change of level in Continue Wave(CW) and the output of a high brightness LED could be controlled stage by stage. Compared with one LED irradiation, several LEDs irradiation could increase optical power.

Analysis of Characteristic of Wound Therapy Apparatus using ${\mu}$-Controller (마이크로컨트롤러를 이용한 창상 치유기의 특성 평가)

  • Cheon, Min-Woo;Kim, Seong-Hwan;Park, Yong-Pil;Lee, Ho-Sik;Kim, Tae-Gon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.497-497
    • /
    • 2007
  • We developed the light medical therapy apparatus for external injury cure using a ${\mu}$-controller. This equipment was fabricated by using a high brightness LEDs and a ATmega 128, and designed to enable us to control irradiation timer, intensity and reservation. Especially, to control the light irradiation frequency, and to control the change of output value, TLC5941 was used. Control stage is divided into 4 step by program. Consequently, the current value could be controlled by the change of level in Continue Wave(CW) and the output of a high brightness LEDs could be controlled, stage by stage. In this paper, the designed device was used to find out how a high brightness LEDs light source affects the skin wound of a small animal. In result, compared with none light irradiation animal, the lower incidence of inflammation and faster recovery was shown in light irradiation animal.

  • PDF

Adaptation of light emitting diode (LED) at culture on attachment plate of diatom (부착조류 파판배양 시 Light Emitting Diodes (LEDs)의 적용)

  • Bae, Jae-Hyun;An, Heui-Chun;Kim, Mi-Gyeong;Park, Jin-Chul;Park, Heum-Gi;Kwon, O-Nam
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.50 no.4
    • /
    • pp.542-550
    • /
    • 2014
  • We investigated biomass, diatom species and fucoxanthin contents as cell growth, fatty acid and amino acid contents as nutritional composition of diatoms attached on plate to confirm effects of light emitting diodes (LEDs) due to block off natural light. In the single LED irradiation, biomass showed significantly higher to $30.0{\pm}6.48mg/m^2$ in white LED than that of others (P<0.05). The dominate diatom species was Navicula cancellata. Their lipid contents showed significantly higher to $112.9{\pm}19.23ug/mg$ dry matter (DM) in control than that of others LEDs. But eicosapetaenoic acid (EPA) contents showed significantly higher to $3.3{\pm}0.62ug/mg$ DM than others, but not significantly differed with natural control light treatment (P<0.05). And total protein contents are higher in control and blue LED light than that of others, but essential amino acid contents showed significantly higher to $3.2{\pm}4.8%$ in control (P<0.05). In mixing light with natural and LED light, biomass showed $2.6{\pm}0.22mg/m^2$ in blue LED (P<0.05). Fatty acids contents were not significantly differed with all treatments. Amino acid contents showed to $11.0{\pm}0.33ug/mg$ DM in white LED (P<0.05), but not significantly differed with others LED lights (P>0.05). Therefore, we could suggest that irradiation of blue LED in natural light very benefit to diatom culture for larvae of sea cucumber and abalone and do on.

Effect of Light Emitting Diodes Treatment on Growth and Quality of Lettuce (Lactuca sativa L. 'Oak Leaf') (LED 처리가 상추의 생육 및 품질에 미치는 영향)

  • Shin, Yong-Seub;Lee, Mun-Jung;Lee, Eun-Sook;Ahn, Joon-Hyung;Kim, Min-Ki;Lee, Ji-Eun;Do, Han-Woo;Cheung, Joung-Do;Park, Jong-Uk;Um, Young-Ghul;Park, So-Deuk;Chae, Jang-Heui
    • Journal of Life Science
    • /
    • v.24 no.2
    • /
    • pp.148-153
    • /
    • 2014
  • The objective of this study was to elucidate the effect of light-emitting diode treatment on early growth and inorganic elements in leaf lettuce (Lactuca sativa L. 'Oak Leaf'). In changes to leaf morphology, shoot elongation and hypocotyl length showed poor growth under red light irradiation, while red+blue light irradiation induced shorter plant height and more leaves, resulting in increased fresh weight. With respect to Hunter's color and SPAD values, lettuce seedlings grown under red+ blue and fluorescent light irradiation had a higher $a^*$ value but showed no other changes to SPAD values. Interestingly, redness in relative chlorophyll content was 1.4 times higher under red+blue light irradiation. Inorganic element (N, Ca, Mg, and Fe) and ascorbic acid concentrations increased in lettuce plants grown under LED light irradiation compared to those of lettuce grown under fluorescent light, which showed a higher P content. In conclusion, red+blue light irradiation, which stimulates growth and higher nutrient uptake in leaf lettuce, could be employed in containers equipped with LEDs.