• 제목/요약/키워드: Light detector

검색결과 451건 처리시간 0.03초

자외선 경화 하이드로겔을 사용한 일회용 빛 노출 검출 키트의 제조와 특성분석 (Fabrication of Disposable Light Exposure Detector Kit using UV Curable Hydrogels)

  • 김영호;김규만;;최진호;김환곤;박상주;이상학
    • 응용화학
    • /
    • 제15권1호
    • /
    • pp.17-20
    • /
    • 2011
  • A disposable light exposure detector kit has been developed by UV curing of a hydrogel material. The devised light exposure detector kit consisted of light sensitive structures, bottom plate, character sheet and sticky back plate. A light exposure detector kit has a serial light sensitive structures that contain various light sensitive dyes such as rhodamine and fluorescein. The light sensitive structure composed of UV curable hydrogel polymer material as a supporing material and photosensitive dye in a certain concentration. The fabrication procedure of the ligh exposure detector kit is very simple and fast due to UV curing procedure of a photopolymerizable hydrogel material such as poly(ethylene glycol) methyl ether acrylate (PEGMEA) and poly(ethylene glycol) diacrylate (PEGDA) with a photosensitive dye. By the proposed fabrication method, various size and shape of a light exposure detector kit could be fabricated using a flexible elastomer mold. Due to a fast and inexpensive fabrication method, the light exposure detector kit could be use a single use for various industrial applications. According to light irradation, the light sensitive structure on a light exposure detector kit could be lose its color by decomposition of a photosensitive dye chemical in the structure. Thus the amount of the exposed light on a substrate could easily be recognised by changing color or transparency of the structure.

써모파일 센서를 이용한 NDIR CO2 가스검출기의 개발 (Development of NDIR CO2 Gas Detector Using Thermopile Sensor)

  • 조시형;박찬원
    • 산업기술연구
    • /
    • 제32권A호
    • /
    • pp.35-38
    • /
    • 2012
  • We present a novel non-dispersive infrared (NDIR) $CO_2$ gas sensor with a light source emitting collimated light. Using this thermopile, we also have successfully developed a small, sensitive NDIR $CO_2$ detector module for accurate air quality monitoring systems in energy-saving building and automotive applications. The novel sample cavity comprising specular reflectors around the light bulb is configured to uniformly emit collimated light into the entrance aperture of the cavity in order to enhance the sensitivity of NDIR $CO_2$ detector.

  • PDF

Remote Water Quality Warning System Using Water Fleas

  • Park Se-Hyun;Kim Eung-Soo;Park Se-Hoon
    • Journal of information and communication convergence engineering
    • /
    • 제4권2호
    • /
    • pp.92-96
    • /
    • 2006
  • Hardware for monitoring the water quality using water fleas is developed. Water flea is a frequently used biological sensor for monitoring the water quality. Water fleas quickly respond to the incoming toxic water by changing their activity when they are exposed. By measuring the activity of water fleas, the incoming toxic water is instantly detected. So far the measurement of activity of water fleas has been done with a system equipped with both a light source of LED and a light detector of photo transistor. Water flea itself is, however, sensitive to light resulting in incorrect response and the system has two inconvenient separate parts of the light source and the detector. This paper suggests a system using a CCD camera instead of a light source and a detector. The suggested system processes the image data from the CCD camera in real time without any delay. The developed system becomes a part of the remote water monitoring embedded system.

Near-Infrared Light Propagation in an Adult Head Model with Refractive Index Mismatch

  • Kim, Seung-Hwan;Lee, Jae-Hoon
    • ETRI Journal
    • /
    • 제27권4호
    • /
    • pp.377-384
    • /
    • 2005
  • We investigate near-infrared light (NIR) propagation in a model of an adult head using an extensive Monte Carlo (MC) simulation. The adult head model is a four-layered slab which consists of a surface layer, a cerebrospinal fluid layer, a gray-matter layer, and a white-matter layer. We study the effects of a refractive index mismatch on the model, calculating the intensity of detected light, mean flight time, and partial mean flight time of each layer for various refractive indices of the cerebrospinal fluid layer as functions of source-detector spacing. The Monte Carlo simulation shows that the refractive index mismatch presents very rich results including rapidly decaying intensity of detected light and a peak and cross-over in the partial mean flight time with source-detector spacing. We also investigate spatial sensitivity profiles at various source-detector spacings, discussing the index mismatch effect on the model.

  • PDF

A measurement of wave length response on light emitting diode by a simplified wavemeter with a semiconductor color sensor

  • Muraoka, Tetsuya
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.1956-1960
    • /
    • 1991
  • This paper describes the measured results upon monochromatic light, compound light, and light emanated from light emitting diodes by a simplified wavemeter with a semiconductor color sensor. Since a single unit element of a semiconductor color sensor with two PN junction photodiodes has been developed, the author has fabricated the simplified wave detector by using the element. The simplified wive detector has been measured results upon monochromatic light, compound light, and light emanated from light emitting diodes. Since luminescent color of each diode locates in luminosity region, comparison of measured values of PD-150 and PD-151 resulted no remarkable difference in averaged wave length. As for monochromatic light, PD-151 showed very cross value to the color filter peak value rather than PD-150. As for compound light, PD-150 has shown such influence of long wave length light which reaches to near infrared ray with respect to PD-151.

  • PDF

The Relation between Statistics of Input Photons and Photocounts

  • Ha, Yang;Kim, Heo-Noh;Shin, Jong-Tae;Park, Goo-Dong;Kim, Ill-Won;Kim, Tae-Soo;Kang, Hee-Dong
    • Journal of the Optical Society of Korea
    • /
    • 제4권2호
    • /
    • pp.71-74
    • /
    • 2000
  • The relation between the statistics of photons in input light on a detector and the measured photocounts by the detector is discussed. The averages and variances of the photocounts are compared with the averages and variances of input photons on practical detectors having quantum efficiencies of $\mu$. This comparison was made for three kinds of inputs which include Fock state light, coherent light, and thermal light. The calculations were carried out based on the combined operator model for a detector having less-than-unit quantum efficiency.

전면광원(Front Light)을 적용한 액정 X선 검출기 개발 (Development of X-ray Detector using Liquid Crystal with Front Light)

  • 노봉규;백삼학;강석준;이종모;배병성
    • 한국방사선학회논문지
    • /
    • 제13권6호
    • /
    • pp.831-840
    • /
    • 2019
  • 액정을 이용하는 X-선 검출기에서 전면광원을 적용하는 액정 X선 검출기를 제안하였고 X선 영상을 찍어 작동을 확인하였다. 제안한 방식은 빛을 이용하므로 트랜지스터를 이용하는 방식에 비해 잡음이 적고 제작 비용을 낮출 수 있다. 액정을 이용하는 검출기는 광도전층을 이용하여 입사 X선을 액정의 분자 배열 변화로 유도하고 액정을 통과하는 빛의 변화량을 읽도록 한다. X선을 조사하고 잰 빛의 투과율과 이것에 대응되는 기준투과율 곡선의 전압으로부터 X선 조사량을 교정(Calibration)하는 과정을 정립하였다. 비정질 셀레늄을 광도전층으로 적용하였으며 200℃ 이상의 고온 처리가 필요한 배향막 공정 대신 패럴린 배향막을 사용하는 공정을 확립하였다. 제안된 액정 X선 검출기의 경우, 방사선량을 획기적으로 줄일 수 있다는 것을 시뮬레이션으로 보였다. 제안된 방식의 X-선 검출기를 제작하고 액정 바이어스 전압을 조절하며 X-선 라인 영상을 비교하였으며 고정 바이어스에서 시간에 따른 이미지 변화를 관찰하였다. 영상사진으로 10 lines/mm의 선패턴을 구별할 수 있었다. 이러한 실험을 바탕으로 검출 패널의 위상이 3π 정도인 17인치 시제품에 적용하여 저선량 액정 X선 검출기의 상용화를 추진할 예정이다.

a-Se을 이용한 디지털 X-선 검출기의 Discharge Erasing Method에 관한 연구 (Study of Discharge Erasing Method of a-Se based Digital X-ray Detector)

  • 이동길;박지군;최장용;강상식;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.395-398
    • /
    • 2002
  • Many research group started study to develope x-ray detector using thin film transistor from 1970. But realization of TFT based x-ray detector development was caused by progress of thin film transistor liquid crystal display(TFTLCD) device technology in 1990. The main current of TFT technology is display device. Research results expend TFT technology field from display device to sensor manufacture technology. These days many research group in the world realize various digital x-ray detector. In this study, We compare discharge erasing method to visible light erasing method in a-Se based digital x-ray detector. Visible light erasing method is known reset process in direct conversion x-ray detector. Digital x-ray detector using visible light erasing method is not adaptive for conventional x-ray device, because of its thickness. And it is not avaliable for real-time imaging for digital fluoroscopy, because of its long reset time. In this study we overcome these limitations and show new idea for real-time imaging method.

  • PDF

고체형 검출기를 위한 핀 포토다이오드 제작 (Fabrication of PIN Photodiode for Solid-state Detector)

  • Kwak, Sung-Woo;Gyuseong Cho;Hyungjoo Shin;Park, Seung-Nam
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2003년도 하계학술발표회
    • /
    • pp.98-99
    • /
    • 2003
  • PIN photodiode has been used in solid-state detector for x-ray detection as a photosensor of visible light from scintillator. Since the light from CWO is short wavelength having peak at 490nm, the light is absorbed within a very shallow layer near the surface of the photodiode before arriving at the depletion layer and does not contribute to the signal. In designing the PIN photodiode, it is important to make the p-layer as shallow as possible. (omitted)

  • PDF

Large-size LCD with touch-sensing capability

  • Zhu, X.L.;Sit, Cass K.M.;Ma, Mark W.;Feng, Y.J.;Ng, K.W.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.1519-1522
    • /
    • 2009
  • We describe a 32" liquid-crystal display (LCD) with multi-touch sensing capability by integrating IR detector arrays onto the LED backlight plate. A transparent light guide is placed in front of the display screen, with IR LEDs disposed at its edges and emitting IR light into the light guide, the light is trapped by total internal reflection within the light guide to be as touch-sensing light. A physical contact with the acrylic plate surface will stimulate some trapped light to be escaped from the light guide and pass through LCD panel to be detected by the IR detectors. The touch-sensing LCD with this configuration can locate simultaneous multiple touche points on the touchable surface.

  • PDF