• 제목/요약/키워드: Light curing time

검색결과 148건 처리시간 0.022초

SOLUTION CHARACTERISTICS AND MEMBRANE FORMATION OF PARTIALLY IMIDIZED POLY (AMIC ACID)

  • Lee, Hyuck-Jai;Won, Jong-Ok;Park, Hyun-Chae;Lee, Hoo-Sung;Kang, Yong-Soo
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1999년도 The 7th Summer Workshop of the Membrane Society of Korea
    • /
    • pp.83-86
    • /
    • 1999
  • The imidization effect of a poly (amic acid) dope solution on membrane formation has been investigated. Poly (amic acid) solution in S-methyl-2-pyrrolidione hs been thermally imidized at $120^{\circ}C$ with different curing time and its degree of imidization was determined by infrared spectroscopy. The solution properties have been studied as a function of concentration and curing time by dynamic light scattering. The quality of a solvent was changed from good to poor with increasing imidization of poly(amic acid).The reduced polymer-solvent interaction diminishes the membrane formation time. The morphology of a membrane was able to be controlled by the characteristics of dope solution.

  • PDF

UV 챔버 내부 온도 및 체류시간이 Urethane Acrylate의 경화속도에 미치는 영향 (The Effect of Temperature and Exposure Time on UV-curing of Urethane Acrylate)

  • 문승호;김광희;김정식
    • 한국산학기술학회논문지
    • /
    • 제13권9호
    • /
    • pp.3822-3826
    • /
    • 2012
  • 소형 UV 챔버 내부온도 및 챔버 내 체류시간이 Urethane Acrylate 의 경화속도에 미치는 영향을 조사하였다. UV 램프에 가해지는 Power를 60, 80, 100% 로 조절하여 UV 조사량 (UV dose)를 변경하였고 필름이 지나가는 챔버 내부의 가이드롤 (또는 패턴롤)에 냉각수를 투입하여 롤 자체의 온도에 변화를 주었다. 또한 코팅속도를 조절하여 챔버 내부에서의 체류 시간을 변경시켰는데 이들 조건들이 Urethane Acrylate 의 경화에 어떠한 영향을 미치는지를 알아보기 위하여 경화된 필름의 gel 분율을 측정, 비교하였다. 본 연구를 통해 Power가 증가 할수록 경화기 내부의 온도는 상승 하였으며 냉각수 투입에 따라 경화기 내부의 온도는 감소하였는데 이러한 경화기 내부의 온도변화는 UV 경화에 큰 영향을 미치지 않음을 알 수 있었다. 반면에 코팅속도가 증가할수록 경화필름의 gel 분율은 감소하였는데 이는 충분한 경화를 위해서는 경화기내부에서의 체류시간이 일정 이상이 되어야 함을 의미하였다. 한편, 체류시간에 따른 UV dose 측정 및 UV 램프주변의 열유동 해석을 통하여 램프주변의 온도분포 해석을 시도하였는데 이러한 결과들을 바탕으로 UV 경화기 구조 및 운전 조건이 UV 경화된 제품의 특성에 어떠한 영향을 미치는지 알 수 있었다.

광중합 복합레진의 중합초기 동적 점탄성의 변화 (THE CHANGE OF THE INITIAL DYNAMIC VISCO-ELASTIC MODULUS OF COMPOSITE RESINS DURING LIGHT POLYMERIZATION)

  • 김민호;이인복
    • Restorative Dentistry and Endodontics
    • /
    • 제34권5호
    • /
    • pp.450-459
    • /
    • 2009
  • 본 연구의 목적은 새로 개발한 점탄성 측정기를 사용하여 수종의 광중합 복합레진의 초기 동적 점탄성 변화를측정하는 것이다. 본 연구에 사용된 점탄성 측정기는 세 부분으로 구성되었다. 첫째, 시편이 놓여지는 parallel plates; 둘째, DC 모터와 크랭크로 이루어진 회전진동전단변형 (Oscillatory shear strain)을 발생시키는 부분; 셋째, 전자기적 토크센서를 이용한 응력 측정 부분으로 구성되었다. 본 점탄성 측정기는 최대 2 Ncm의 토크를 측정할 수 있으며, 광중합기의 스위치는 컴퓨터와 연동하여 데이터 획득을 시작할 때 동시에 켜지도록 하였다. 본 연구에서는 시판 중인 6종의 광중합 복합레진 [Z-100 (Z1), Z-250 (Z2), Z-350 (Z3), DenFil (DF), Tetric Ceram (TC), Clearfil AP-X (CF)]을 사용하였다. 점탄성 측정기를 사용하여 동적 회전전단실험을 시행하였다. 직경 3 mm인 유리막대로 구성된 parallel plates 사이에 $14.2\;mm^3$의 복합레진을 적용시켰으며, 6 Hz의 진동수와 0.00579 rad의 진폭으로 변형을 가하고 발생된 응력을 측정하였다. 광중합이 시작됨과 동시에 측정이 시작되었으며, 광중합 후 10초 동안 점탄성의 변화를 관찰하였다. 각 복합레진에 대해 5 회 반복하여 측정하였고, 실험은 $25{\pm}0.5^{\circ}C$에서 진행되었다. 측정된 변형-응력 곡선으로부터 복소전단탄성계수 G*, 저장전단탄성 계수 G', 손실전단탄성 계수 G"를 구하였고 G*가 10 MPa에 이르는 시간을 구하였다. 각 재료의 복소전단탄성계수 G*와 10 MPa에 이르는 시간에 대해 일원분산분석 (One-way ANOVA)과 사후검정 (Tukey 검정)을 시행하였다 (${\alpha}$= 0.05). 결과는 다음과 같다. 1.본 연구를 위해 제작한 점탄성 측정기는 광중합 복합레진의 중합 초기 10초 동안의 동적 점탄성 변화를 신뢰성 있게 측정 할 수 있었다. 2. 모든 복합레진은 광조사 개시 후 $1{\sim}2$초의 불응기를 지난 다음 급격한 전단탄성계수의 증가를 보였다. 3. 모든 복합레진은 광중합 10 초간 손실전단탄성계수보다 저장전단탄성계수의 높은 증가를 보였다. 4. 광중합 초기 10초 후 복소전단탄성계수 값은 $150.3{\sim}563.7\;MPa$로, Z-100이 가장 높았고, 그 다음 Clearfil, Z-250, Z-350, Tetric Ceram, DenFil의 순이었다. 5. 복소전단탄성계수가 10 MPa에 이르는 시간은 Z-100이 2.55초로 가장 빨랐고, DenFil이 4.06초로 가장 느렸다.

Streptococcus mutans biofilm에 대한 광역동 치료의 최적조건에 관한 연구 (Optimum Treatment Parameters for Photodynamic Antimicrobial Chemotherapy on Streptococcus mutans Biofilms)

  • 최서정;박호원;이주현;서현우;이시영
    • 대한소아치과학회지
    • /
    • 제42권2호
    • /
    • pp.151-157
    • /
    • 2015
  • 할로겐 광중합기를 광원으로, 치면세균막 착색제인 erythrosine을 광감각제로 사용하여 S. mutans biofilm에 대한 광역동 치료를 시행할 때의 최적조건을 알아보기 위해서 erythrosine의 농도와 광조사 시간 및 광감각제의 접촉시간에 따른 광역동 치료의 효과를 비교하였다. erythrosine의 농도를 0, 10, 20, 40, $80{\mu}M$로 변화시킨 결과 농도가 증가할수록 항균효과가 증가하는 경향을 보였으며 $40{\mu}M$$80{\mu}M$의 두 군에서 통계적 유의성이 나타났다. 광 조사 시간을 0, 5, 15, 30, 60, 75초로 변화시킨 결과 조사 시간이 길어질수록 항균효과가 증가하는 경향을 보였으며 30초, 60초, 75초의 세 군에서 통계적 유의성이 나타났다. erythrosine 처리시간을 0분, 1분, 2분30초, 5분으로 변화시킨 결과 erythrosine과의 접촉시간이 늘어날수록 항균효과가 증가하는 경향을 보였으며 2분30초 군과 5분 군에서 통계적 유의성을 보였다. 이상의 결과로 광감각제로 사용한 erythrosine의 농도를 $20-40{\mu}M$, 광원으로 사용한 할로겐 광중합기의 광 조사시간을 30초 이상, 광감각제인 erythrosine을 2분30초 이상 처리하여 사용하는 것이 치아우식 예방을 위한 광역동 치료에 효과적임을 알 수 있다.

오토클레이브 양생시간에 따른 경량기포콘크리트의 강도 변화에 관한 실험적 연구 (Strength Variations of Light Weight Foamed Concrete According to the Autoclaving Time)

  • 강철;강기웅;곽은구;노재명;권기주;김진만
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2005년도 춘계 학술기술논문발표대회 논문집
    • /
    • pp.57-60
    • /
    • 2005
  • This is the experimental study on the strength development of the light weight concrete block according to the autoclaving time. The calcareous source used the cement, siliceous material used the bottom ash ground to fine particle, and the PP fiber used to increase toughness. The results of this experiment are as follows. According to the increase of autoclaving time and the fiber content, compressive and flexural strengths are increased. Despite of the changes of the autoclaving time, tobermorite was produced on each of the specimens. However, the phase of tobermorite was changed in accordance with the changes of autoclaving time.

  • PDF

가시광선과 플라스마 광선에 의한 복합레진 중합시 미세누출과 미세경도에 관한 연구 (THE COMPARATIVE STUDY OF THE MICROHARDNESS AND MICROLEAKAGE IN POLYMERIZATION OF COMPOSITE RESIN CURED WITH VISIBLE LIGHT AND PLASMA ARC CURING UNITS)

  • 김상배;이광수
    • 대한소아치과학회지
    • /
    • 제29권2호
    • /
    • pp.180-188
    • /
    • 2002
  • 최근에 소개된 plasma arc curing units는 비교적 높은 광 강도를 가지고 짧은 시간내에 복합레진을 적절히 중합시킨다고 한다. 이 연구는 plasma arc curing units의 강한 광도와 짧은 시간에 의한 중합이 복합레진에 미치는 영향을 평가하기 위해 기존의 가시광선 중합기를 대조군으로 하여 표면 미세경도와 5급 수복물의 변연에 나타나는 미세누출을 색소침투방법으로 측정, 분석하여 다음과 같은 결론을 얻었다. 1. 각 깊이에서의 미세경도는 AHL군이 AP3, AP6군보다 모든 깊이에서 높았고, ZHL군보다 ZP6군이 표면에서 더 높았으며(P<0.05), 1mm와 2mm에서는 차이가 없었다(P>0.05). 그 외 모든 깊이에서 ZHL군이 ZP3, ZP6군보다 높았다(P<0.05). 2. 각 중합방법내 깊이에 따른 미세경도는 AHL군의 표면-1mm와 ZHL군의 1mm-2mm를 제외하고는 모든 군에서 깊이에 따라 감소되었다(P<0.05). 3. 교합면측과 치경부측 미세누출은 모든 중합군에서 교합면측이 낮게 나타났지만 유의한 차이는 없었다(P>0.05). 4. 중합방법간 미세누출은 모든 군에서 차이가 없었다(P>0.05). 5. 각 중합방법에 따른 재료간의 미세누출은 차이가 없었다(P>0.05).

  • PDF

다양한 파장폭의 가시광선에 의해 중합된 복합레진의 미세경도와 변연누출도 (MICROHARDNESS AND MICROLEAKAGE OF COMPOSITE RESIN CURED BY VISIBLE LIGHT WITH VARIOUS BAND OF WAVELENGTH)

  • 박수만;이재용;한승렬;하상윤;신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제27권4호
    • /
    • pp.403-410
    • /
    • 2002
  • Several ways of curing are being tried to improve material's properties and reduce marginal gap. However, all are considering about the pattern of light intensity. It was noted from the preliminary study the change of light wavelength from filter changing may give an impact on material's property and microleakage. The object of this study was to verify the effect of filters with various wavelength width on the microhardness and microleakage of composite resin ; hybrid type of DenFil and submicron hybrid type of Esthet X. Composite resins were cured using 3 kinds of filter; narrow-banded(465-475 nm), mid-banded(430-470 nm), wide-banded(400-500 nm). After the estimation of microhardness. degree of dye penetration and the maximum gap from SEM evaluation were done between 4 groups that showed no difference in microhardness value of the lower surface . The results were as follows : 1 Adequate microhardness could not be gained with a narrow-banded filter irrespective of curing time. At the upper surface, DenFil should be polymerized with middle or wide-banded filter for 20 seconds at least, while Esthet X be col$.$ed with middle or wide-banded filter for 30 seconds at least to get simitar hardness value to control group. 2. There was little dye penetration in enamel margin, but all dentin margins skewed much more dye penetration irrespective of curing conditions. Although there was no statistical difference, groups cured with mid-banded filter for 40 seconds and with wide-width filter for 20 seconds showed relatively less dye penetration. 3. It was revealed from the SEM examination that group cured with wide-banded filter had the smallest gap without statistical significance. Spearman's rho test showed that the correlation between the results of dye penetration and SEM examination was very low. From these results, it could be concluded that curing with wide-width filter would be better than the other techniques, even though the curing technique using mid-width filter seems to have its own unique advantage.

염소화/Monoethanol Aminesulphite 방축가공의 처리조건이 양모직물의 염색성에 미치는 영향 (Effect of Treating Conditions on Dyeing Property of Anti-Shrinkage Wool Fabric Treated with Chlorination and Monoethanol Aminesulpbite Resin)

  • 황백순;이재호;박정환;김덕리
    • 한국의류산업학회지
    • /
    • 제3권3호
    • /
    • pp.283-289
    • /
    • 2001
  • Shrink resist finishing of wool fabric was carried out with Monoethanol aminesulphite (MONAMIN BTN) shrink resist agent after chlorination with Dichloro isocyanuric acid (DCCA). The purpose of this study is to investigate the effect of treating conditions, such as concentrations of DCCA and MONAMIN BTN, pH of treating bath, dyeing times, curing times and temperatures, on dyeing property of wool fabrics. K/S values and fastness properties of dyed wool fabrics were measured. The K/S values of dyed fabrics were increased gradually with increasing concentration, and decreased with increasing curing time. The optimum dyeing time and curing temperature were 60 min and $140^{\circ}C$, respectively. Also it seems likely that the shrink resist finishing carried out at 3% (o.w.f.) of MONAMIN BTN and pH 7 of resin treating bath is effective in increasing K/S values. Light fastness of fabric dyed was very poor and the fastness of fabric dyed was not influenced by the treatment conditions.

  • PDF

광중합 방법 및 레진 접착제의 종류에 따른 유치 수복물의 미세누출 (THE EFFECT OF LIGHT CURING METHODS AND RESIN ADHESIVES ON THE MICROLEAKAGE OF RESTORATIONS IN PRIMARY TEETH)

  • 정영남;김대업;이광희
    • 대한소아치과학회지
    • /
    • 제29권4호
    • /
    • pp.592-599
    • /
    • 2002
  • 광중합형 복합레진 및 다양한 레진 접착제는 최근 소아의 유치 수복에 사용이 증가하고 있다. 본 연구는 유치의 복합레진 수복 시 중합방법과 접착제에 따른 미세누출의 차이를 실험적으로 관찰하고자 하였다. 탈락기에 있는 건전한 유전치 150개의 순면에 직경 1.6mm, 깊이 1.6mm의 와동을 형성하였다. 와동의 충전재로써 1종의 복합레진, 1종의 콤포머, 4종의 레진 접착제를 사용하였다. 중합 광원은 3종을 사용하였다. 충전이 완료된 각 시편은 Sof-Lex 폴리싱 디스크로 표면을 연마한 후 $5^{\circ}C$$55^{\circ}C$에 각 30초씩 계류시켜 1,000회 열순환하고 2% methylene blue 수용액에 넣어 색소를 침투시킨 후 저속 diamond cutter($Isomet^{TM}$, Buehler, USA)를 이용하여 순면을 근원심으로 절단하였다. 각 재료별 미세누출의 정도를 관찰하여 다음과 같은 결과를 얻었다. 1. 충전재 및 광중합 방법에 따른 미세누출을 측정한 결과, 콤포머를 사용한 5군에서 충전방법과 관계없이 가장 작았고, Clearfil SE bond를 Optilux 501로 중합한 군에서 가장 컸으나 통계적으로 유의한 차이는 아니었다(P>0.05). 2. 충전재에 따른 미세누출을 측정한 결과, 콤포머를 충전한 5군에서 $1{\sim}4$군의 복합레진 충전군에 비해 더 작은 미세누출을 보였다(P<0.05). 3. 광중합 방법에 따른 미세누출을 측정한 결과, Optilux 501을 사용한 군에서 가장 작았고, Flipo를 사용한 군에서 가장 컸으나 통계적으로 유의한 차이는 아니었다(P>0.05).

  • PDF

광원의 종류에 따른 복합레진의 중합거동 및 중합률에 관한 연구 (THE POLYMERIZATION RATE AND THE DEGREE OF CONVERSION OF COMPOSITE RESINS BY DIFFERENT LIGHT SOURCES)

  • 류주희;이인복;유현미;김미자;석창인;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제29권4호
    • /
    • pp.386-398
    • /
    • 2004
  • Objectives: The purpose of this study was to observe the reaction kinetics and the degree of polymerization of composite resins when cured by different light sources and to evaluate the effectiveness of the blue Light Emitting Diode Light Curing Units (LED LCUs) compared with conventional halogen LCUs. Materials and Methods: First, thermal analysis was performed by a differential scanning calorimeter (DSC). The LED LCU (Elipar Freelight, $320{\;}mW/\textrm{cm}^2$) and the conventional halogen LCU (XL3000, $400{\;}mV/\textrm{cm}^2$) were used in this study for curing three composite resins (SureFil, Z-250 and AEliteFLO). Second. the degree of conversion was obtained in the composite resins cured according to the above curing mode with a FTIR. Third, the measurements of depth of cure were carried out in accordance with ISO 4049 standards. Statistical analysis was performed by two-way ANOVA test at 95% levels of confidence and Duncan's procedure for multiple comparisons. Results: The heat of cure was not statistically different among the LCUs (p > 0.05). The composites cured by the LED (Exp) LCUs were statistically more slowly polymerized than by the halogen LCU and the LED (Std) LCU (p < 0.05). The composite resin groups cured by the LED (Exp) LCUs had significantly greater degree of conversion value than by the halogen LCU and the LED (Std) LCU (p =0.0002). The composite resin groups cured by the LED (Std) LCUs showed significantly greater depth of cure value than by the halogen LCU and the LED (Exp) LCU (p < 0.05).