광중합의 시작, 어떤 광조사기를 어떻게 사용해야할까? (Clinical considerations in the use of dental light curing unit)

  • 이창하
    • 대한치과의사협회지
    • /
    • 제57권3호
    • /
    • pp.175-184
    • /
    • 2019
  • Increasing the aesthetic needs of patients and decreasing the use of amalgam had led to increased demand for dental resin composite. Thereby, light curing unit (LCU) has become an essential equipment in dental clinic. To ensure long-term prognosis of photopolymerized materials, LCU should have a uniform and consistent radiant output and an emission spectrum that includes the active wavelength range of photoinitiators. In addition, when the correct use and thorough maintenance and repair of LCU are performed, the higher success rate of restoration using photopolymerization materials will be achieved.

  • PDF

발광 다이오드 광중합기의 복합레진 중합 평가 (Evaluation of New LED Curing Light on Resin Composite Polymerization)

  • 강지은;전새로미;김종빈;김종수;유승훈
    • 대한소아치과학회지
    • /
    • 제41권2호
    • /
    • pp.152-156
    • /
    • 2014
  • 최근 도입된 광범위 스펙트럼의 발광 다이오드 광중합기는 4개의 램프로 구성되어 있으며 다양한 중합 모드를 가지고 있다. 이 연구는 광범위 스펙트럼 발광 다이오드($VALO^{(R)}$, Ultradent, USA) 광중합기와 기존의 발광 다이오드 광중합기 ($Elipar^{TM}$ Freelight 2, 3M ESPE, USA)의 효율을 미세경도 시험을 통해 비교하였다. 연구에 사용한 광중합기는 $VALO^{(R)}$$Elipar^{TM}$ Freelight 2이며 중합 시간은 제조사의 지시에 따랐다. $37^{\circ}C$의 생리식염수에 중합된 레진 시편을 24시간 동안 보관한 후 미세경도 시험을 시행하였다. 시편 상부와 하부의 복합레진 미세경도는 공분산분석을 시행하였다. 광범위 스펙트럼의 발광 다이오드 광중합기를 이용하여 고성능 모드에서 4초, 플라즈마 모드에서 20초 광중합을 실시한 복합레진 시편의 상부는 기존의 발광 다이오드 광중합기에 비해 미세경도가 증가하였으나(p < 0.05), 시편의 하부에서는 실험에 사용된 광중합기 간에 유의성 있는 차이를 보이지 않았다.

치면열구전색제의 표면처리와 중합시간 증가에 따른 미반응 모노머 용리 평가 (MONOMER RELEASE FROM PIT AND FISSURE SEALANT FOLLOWING BY SURFACE TREATMENT AND CURING TIME)

  • 서현우
    • 대한소아치과학회지
    • /
    • 제34권1호
    • /
    • pp.122-129
    • /
    • 2007
  • 본 연구는 복합 레진의 중합률에 영향을 미치는 광조사 시간을 달리하여 치면열구전색제를 중합하였을 경우 이로부터 용리되는 미반응 모노머들을 확인하고 정량화하고자 하였다. 그리고 치면열구전색제 중합 후 표면에 나타나는 미반응 모노머 층을 다양한 방법으로 제거한 후 용리되는 미반응 모노머들을 정량분석함으로써 미반응 모노머의 제거효과를 비교평가하고자 하였다. 광중합 시간에 따라 각각 20초, 40초, 60초간 중합한 후, 중합시간 별로 어떠한 처리도 시행하지 않은 군을 대조군, 증류수로 10초간 세척한 군을 I군(Group I), 75% 알콜에 젖은 면구로 10초간 문지른 군을 II군(Group II), 퍼미스와 러버컵을 이용하여 10초간 처리하고 증류수로 가볍게 세척한 군을 III군(Group III)으로 분류하였다. 표면처리 후 각 시편을 3차 증류수에 넣고 $37^{\circ}C$ 항온 수조에서 10분간 보관한 후 각각의 용리액을 고성능 액체 크로마토그래피를 이용하여 정성 및 정량 분석을 시행하였고 다음과 같은 결과를 얻었다. 1. 모든 대조군과 실험군에서 TEGDMA를 제외한 어떠한 모노머들도 검출되지 않았다. 2. 최소 중합시간, 권장 중합시간, 권장 중합시간 이상의 순으로 중합시간이 증가할수록 TEGDMA의 용리량은 감소하였다. 3. 표면처리를 한 군들은 대조군에 비하여 TEGDMA의 용리량이 유의할 만하게 감소하였다. 4. 표면처리를 한 군 가운데 퍼미스와 러버컵을 이용한 경우 잔존 모노머의 제거 효과가 다른 군에 비하여 유의성 있게 높았다. 5. 권장 중합시간 이상인 60초 중합 후, 퍼미스와 러버컵을 이용하여 표면처리한 경우 가장 적은 양의 모노머 용리량을 보였다.

  • PDF

플라즈마 광중합기가 복합레진 중합에 미치는 영향 (Effects of plasma arc curing lights on the surface hardness of the composite resins)

  • 이수원;양규호;김선미;최남기
    • 대한소아치과학회지
    • /
    • 제33권4호
    • /
    • pp.624-632
    • /
    • 2006
  • 기존에 사용하고 있는 할로겐 광중합기는 여러 가지 장점에도 불구하고 중합시간이 오래 걸린다는 문제 때문에 시술시간이 길어지는 단점이 있는데, 최근에 개발된 플라즈마 광중합기는 매우 짧은 시간에 중합시킬 수 있다고 제조회사는 주장하고 있다. 본 연구에서는 임상에서 흔히 상용하고 있는 복합 레진을 광중합 할 때, 할로겐 광중합으로 얻을 수 있는 플라즈마 광중합기의 적절한 중합시간을 알아보고자 한다. 2mm 두께의 레진 샘플을 만들어 광중합 하고 24 시간 후 상, 하면의 미세경도를 측정하였다. point $4^{(R)}$에서는 플라즈마 광중합기로 6초간 중합했을 때 할로겐과 유사한 경도를 얻었지만, $Z250^{(R)}$에서는 $Flipo^{(R)}$만 9초간 중합시 할로겐과 유사한 광중합을 나타냈다. 이번 연구에서 사용한 플라즈마 광중합기는 적어도 6초 혹은 9초정도 광중합 했을 때 할로겐과 유사한 중합을 얻을 수 있다는 것을 알 수 있었다.

  • PDF

Plasma arc light를 이용한 bracket 부착시의 전단결합강도와 파절양상의 유형 (Shear bond strength and adhesive failure pattern in bracket bonding with plasma arc light)

  • 유형석;오영근;이승연;박영철
    • 대한치과교정학회지
    • /
    • 제31권2호통권85호
    • /
    • pp.261-270
    • /
    • 2001
  • 본 연구의 목적은 bracket 부착시 광조사시간을 획기적으로 감소시킬 수 있는 plasma arc light의 임상적 유용성을 visible light 중합시의 전단결합강도와 접착파절양상과 비교해 봄으로써 평가해 보는데 있다. 사람의 상하악 소구치를 포매하여 만든 레진블럭시편에 광중합 접착제인 Transbond$^{\circledR}$를 사용하여 수종의 bracket을 각각의 조건에 따라 부착한 후 만능 물성시험기를 이용하여 전단결합강도를 측정하고, 접착파절양상을 stereoscope을 이용하여 관찰하여 다음과 같은 결과를 얻었다. 1. Plasma arc light를 이용한 수종의 bracket 접착시 metal bracket과 ceramic bracket의 전단결합강도는 임상적으로 사용하기에 충분한 값을 나타내었으며, resin bracket 경우 다른 bracket 비해 전단결합강도가 현저히 작은 값을 나타내었지만 임상적으로 사용이 가능한 값을 나타내었다. 2. Visible light를 이용한 metal bracket의 광중합시 광조사시간에 따른 전단결합강도는 광조사 시간에 따른 유의한 차이를 보이지 않았으며, 임상적으로 사용하기에 충분한 강도를 나타내었다. 3. Plasma arc light를 이용한 수종의 bracket 접착시 접착제 잔류지수를 통해 접착파절양상을 관찰한 결과, metal bracket과 resin bracket 경우 bracket기저면에 접착제가 반 이상 남아 있지 않은 경우가 많았으며, ceramic bracket의 경우 bracket기저면에 접착제가 반 이상 남아 있는 경우가 많았다. 4. Metal bracket의 부착시 plasma arc light를 2초간 광조사한 군과 visible light를 10초간 광조사한 군의 전단결합강도와 접착파절양상을 비교시 유의한 차이를 보이지 않았다. 6. Plasma arc light를 이용한 광중합시 광조사 거리에 따른 전단결합강도는 거리가 증가할수록 감소하였다. 이상의 실험 결과는 plasma arc light를 이용한 bracket의 접착시 전단결합강도 저하의 우려 없이 임상적으로 사용 가능함을 시사한다.

  • PDF

광중합원에 따른 복합레진의 색채변화 (COLOR CHANCES IN COMPOSITES ACCORDING TO VARIOUS LIGHT CURING SOURCES)

  • 조영곤;김명조
    • Restorative Dentistry and Endodontics
    • /
    • 제27권1호
    • /
    • pp.87-94
    • /
    • 2002
  • The purpose of this study was to evaluate the color changes of composite resin polymerized with three type of light curing units. Composite resin (Z100, shade A2) were applied in a cylindrical metal mold(2 mm thick, 7 mm diameter). Twenty specimens according to light curing units were made. Group 1 : the specimens were polymerized with Apollo 95E for 3seconds(1370 mW/$\textrm{cm}^2$). Group 2 : the specimens were polymerized with XL 3000 for 40seconds (480 mW/$\textrm{cm}^2$). Group 3 : the specimens were polymerized with Spectrum 800 for 10 seconds(250 mW/$\textrm{cm}^2$) and 30 seconds(700 mW/$\textrm{cm}^2$). The microhardness values(VHN) of upper and lower surfaces specimens after light polymerization were measured for the degree of polymerization. All specimens were stored in distilled water at 6$0^{\circ}C$ for 30 days. The color characteristics(L$^*$, a$^*$, b$^*$) of the specimens before and after immersion were measured by spectrophotometer and the total color difference ($\Delta$E$^*$) was computed. The results obtained were as follows : 1. The microhardness values of Group I showed significantly lower than those of Group II and III (p<0.05). 2. In all groups the $\Delta$E$^*$ values presented below 2.0. 3 Group I showed the highest $\Delta$E$^*$ values followed order from highest to lowest by Group II and III (p<0.05).

Smear layer 제거와 금속 이온 처리가 광중합형 글라스아이오노머와 상아질간의 결합강도에 미치는 영향 (Effect of various cleaners and mordants to bond strength of light curing glass ionomer cements to dentin)

  • 이원섭;박상진
    • Restorative Dentistry and Endodontics
    • /
    • 제19권1호
    • /
    • pp.45-63
    • /
    • 1994
  • 128 freshly extracted human molars were used to study the interaction between dentinal smear layer removal with various agents, and the shear bond strength of a light cured glass ionomer cement to dentin. It was proposed that the removal of smear layers using acidic cleaners followed by incorporation of Fe mordant with dentin could enhanced the infiltration of monomer component in light curing glass ionomer cement and resulted in a high bond strength. For the first treatment process for removal of smear layers on the surfaces of dentin, 50 % citric acid, 10% maleic acid and 10 % phosphoric acid were used, and for the second treatment process, 15% ferric chloride, 6.8% ferric oxalate or 30% potassium oxalate were used. Distilled water was used as a control. After double sequential treatment on dentin, a light curing glass ionomer cement was bonded to dentin. After being immersed in water at 31'C for 24 hours, shear bond strengths were measured Instron testing machine(Model No.4202, USA). Surface changes were also observed using SEM (Hitachi, S-2300, Japan) after treatment process with each agents. The following conclusions were drawn : 1. Dentin surface cleaned with maleic acid and treated with ferric oxalate showed the highest bond strength with light curing glass ionomer cement. 2. Bond strengths of glass ionomer cement to dentin treated with maleic acid or citric acid were the highest, and that treated with phosphoric acid showed the lowest. 3. The effect of ferric oxalate on shear bond strength to dentin was always higher than that of ferric chloride. 4. The smear layers were clearly removed and the orifices of dentinal tubules were opened widely by the citric acid, maleic acid and phosphoric acid. 5. The orifices of dentinal tubules opened after using the first solution were closed with the treatment of ferric chloride. 6. The precipitate like crystals were formed on dentin surfaces and tubules, but a significant decrease in bond strength of glass ionomer cement to dentin surface treated with potassium oxalate.

  • PDF

광중합 레진의 색 안정성과 미세경도에 관한 연구 (A STUDY ON THE COLOR STABILITY AND MICROHARDENSS OF LIGHT CURING RESINS)

  • 오세홍;임미경;조혜원;이광희
    • Restorative Dentistry and Endodontics
    • /
    • 제17권1호
    • /
    • pp.126-133
    • /
    • 1992
  • Tooth colored resin restorative materials are widely used in anterior teeth restorations. The color instability of resin was the main cause of failure in resin restorations. The purpose of this study was to investigate color stability and microhardness of serval visible light curing resins. Colorimetric measurements(Tokyo Denshoku Co., Japan) and microhardness tests(Matusuzawa, MXT 70, Japan) were made on six composite resins before and after controlled immersion treatments. The six composite resins were BIS - FILM(BISCO, USA), Durafill(Kulzer, Germany), Helioprogess(VIVADENT, Germany), Palfique(TOKUYAMA SODA, Japan), Silux(3M, USA), Photoclearfil(KURARAY, Japen). Six light curing resins showed significant color change after 2 weeks. Palfique exhibited the hightest $dE^*$ values and Helio progress presented the lowest $dE^*$ values. Photoclearfil showed the highest microhardness value. Durafill and Helio progress showed lower microhardness values. Microhardness values were decreased after 8 weeks in Bisfil, Palfique light, and Photoclearfil.

  • PDF

광중합 방식의 적층 가공으로 제작된 전치과 구치 단일 크라운의 적합도 평가 (Evaluation of fit of anterior and posterior single crowns manufactured by light-curing additive manufacturing)

  • 배은정;이완선
    • 대한치과기공학회지
    • /
    • 제45권3호
    • /
    • pp.74-80
    • /
    • 2023
  • Purpose: This study aimed to evaluate the fit of the anterior and posterior teeth printed using two light-curing three-dimensional (3D) printers. Methods: Anterior and posterior single crowns were designed using dental software and were printed using 2 types of 3D printers, liquid crystal display (LCD) and digital light processing (DLP) (n=40). After the printed crown was scanned again from inside and outside, the prepared teeth were evaluated using a 3D program. To compare the root mean square (RMS) results among groups (α=0.05), the one-way analysis of variance and Tukey's test were used. Results: No statistically significant difference was found between the mean RMS values of the anterior and posterior teeth (p>0.05). However, as a result of comparing the internal, external, and tooth shapes, the DLP group showed significantly low errors in the inner and outer surfaces than LCD group (p<0.05). Conclusion: In terms of clinical acceptance standard of 100 ㎛, the fit of the anterior and posterior teeth fabricated using LCD and DLP was clinically acceptable.

아르곤 레이저의 소아치과에서의 임상적 적용 (CLINICAL APPLICATION OF ARGON LASER IN PEDIATRIC DENTISTRY)

  • 이미나;이상훈;김종철
    • 대한소아치과학회지
    • /
    • 제24권1호
    • /
    • pp.139-147
    • /
    • 1997
  • Argon laser used in this case report, is special in having two wavelength of 488, 514nm blue-green visible light spectrum. Blue light is used for composite resin polymerization and caries detection. Green light is used for soft tissue surgery and coagulation. Maximum absorption of this laser light occurs in red pigmentation such as hemoglobin. The argon laser may be well-suited for selective destruction of blood clots and hemangioma with minimal damage to adjacent tissues. Argon laser light penetrates tissue to the 1 mm depth, so its thermal intensity is lower than $CO_2$ laser light. Also, due to its short wavelength it can be focused in a small spot and even single gene can be excised by this laser and microscopy. After applicating argon laser to 4 patient for surgical procedure and to 1 patient for curing the composite resin, following results were obtained. 1. Improved visibility were gained due to hemostasis and no specific technique were needed according to easy recontouring of the tissue. 2. Ability to use by contact mode, tactile sense was superior but tissue dragability and accumulation of tissue on the tip needed sweeping motion. 3. Additive local anesthetic procedure was needed. 4. No suture and less curing time reduced chair time, this made argon laser available in pediatric dentistry.

  • PDF