• 제목/요약/키워드: Light Wall

검색결과 623건 처리시간 0.036초

경량 무기 발포패널을 적용한 커튼월의 성능평가 (Performance Evaluation of Curtain-Wall Applying Light-weight Inorganic Foam Panel)

  • 신현욱;송훈;추용식;이종규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.211-212
    • /
    • 2012
  • To prevent energy waste in buildings used heat insulator. Heat insulator materials can be classified inorganic and organic. The organic material is due to toxic gas emission, when a fire occurs. And it has lower water resistance. The inorganic material is heavy and worse thermal performance than organic materials. Technologies on energy saving and materials used in curtain walls have progressed with increase of high-rise and large buildings. However, there is little study to explain fire resistance performance of the curtain walls. This study focused on evaluation of the physical properties of light-weight inorganic foam panel for using industrial by-products materials and performance evaluation by mock up test.

  • PDF

Finite-element modeling of a light-framed wood roof structure

  • Jacklin, Ryan B.;El Damatty, Ashraf A.;Dessouki, Ahmed A.
    • Wind and Structures
    • /
    • 제19권6호
    • /
    • pp.603-621
    • /
    • 2014
  • Past high speed wind events have exposed the vulnerability of the roof systems of existing light-framed wood structures to uplift loading, contributing greatly to economic and human loss. This paper further investigates the behaviour of light-framed wood structures under the uplift loading of a realistic pressure distribution. A three-dimensional finite-element model is first developed to capture the behaviour of a recently completed full-scale experiment. After describing the components used to develop the numerical model, a comparison between the numerical prediction and experimental results in terms of the deflected shape at the roof-to-wall connections is presented to gain confidence in the numerical model. The model is then used to analyze the behaviour of the truss system under realistic and equivalent uniform pressure distributions and to perform an assessment of the use of the tributary area method to calculate the withdrawal force acting on the roof-to-wall connections.

그린팀버월 패널의 전단성능 (Shear performance of green timber wall panels)

  • 김윤희;신일중;장상식
    • 농업과학연구
    • /
    • 제38권3호
    • /
    • pp.541-547
    • /
    • 2011
  • Korean building industry was developed by concrete and steel construction. However, concrete and steel have some problems which low carbon storage capability and difficulty of recycling. According to many studies, timber has high carbon storage capability, high recycling capability and sustainable supporting capability. Focus on this factors of timber, make new wall structure as Green Timber Wall panels and check the shear performance to use wall system in housing construction such as light-weight timber construction and nondearing wall on other construction. In the results, B-4-B and B-4-S show similar modulus of shear stiffness on the table. GH-4-GH has slip shape failure mode between Green Timber Wall boards. GH-4-GV has most stable characteristic curve than other specimens.

경량합성 패널의 압축성능 평가에 관한 실험적 연구 (An Experimental Study for the Evaluations of Compressive Performance of Light-Weight Hybrid Wall Panel)

  • 이상섭;박금성
    • 한국강구조학회 논문집
    • /
    • 제19권5호
    • /
    • pp.455-462
    • /
    • 2007
  • 본 논문은 스틸스터드로 구성된 골조에 경량기포 모르터를 충전하여 제작한 경량합성벽체의 압축 실험을 통한 압축 성능의 평가에 대한 연구이다. 경량기포 모르터의 비중(80, 120), 마감재(경량기포 모르터, OSB, 석고보드) 및 패널의 고정 방식을 변수로 하여 실험체를 제작 실험하였다. 선행 연구결과와 고정부를 개선시킨 경량합성 벽체의 압축성능에 대해 실험을 통해 조사한 결과, 상세개선으로 인한 경량합성패널의 압축 최대하중은 1.07배, 초기강성은 24배 이상 성능이 크게 향상되었다. 비중과 마감재가 동일한 실험체의 경우에는 최대하중은 2.7배, 초기강성은 15배 이상 압축으로 인한 성능이 크게 향상됨을 알 수 있다. 국내설계기준에 의해 계산한 최대하중값과 실험값은 비교적 잘 일치하였다.

Behavior of Concrete/Cold Formed Steel Composite Beams: Experimental Development of a Novel Structural System

  • Wehbe, Nadim;Bahmani, Pouria;Wehbe, Alexander
    • International Journal of Concrete Structures and Materials
    • /
    • 제7권1호
    • /
    • pp.51-59
    • /
    • 2013
  • The use of light-gauge steel framing in low-rise commercial and industrial building construction has experienced a significant increase in recent years. In such construction, the wall framing is an assembly of cold-formed steel (CFS) studs held between top and bottom CFS tracks. Current construction methods utilize heavy hot-rolled steel sections, such as steel angles or hollow structural section tubes, to transfer the load from the end seats of the floor joist and/or from the load-bearing wall studs of the stories above to the supporting load-bearing wall below. The use of hot rolled steel elements results in significant increase in construction cost and time. Such heavy steel elements would be unnecessary if the concrete slab thickening on top of the CFS wall can be made to act compositely with the CFS track. Composite action can be achieved by attaching stand-off screws to the track and encapsulating the screw shank in the deck concrete. A series of experimental studies were performed on full-scale test specimens representing concrete/CFS flexural elements under gravity loads. The studies were designed to investigate the structural performance of concrete/CFS simple beams and concrete/CFS continuous headers. The results indicate that concrete/CFS composite flexural elements are feasible and their structural behavior can be modeled with reasonable accuracy.

L형 케이슨 안벽 구조물의 내진성 평가를 위한 진동대 시험 (Shaking Table Tests for Evaluation of Seismic Performance of L-type Caisson Quay Walls)

  • 한진태;황재익;이용재;김명모
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 춘계 학술발표회논문집
    • /
    • pp.148-156
    • /
    • 2003
  • Shaking table tests and pseudo-static analysis were performed, in this study, on newly-designed aseismatic L-type caisson quay walls, which were constructed by extending the bottom plate of gravity quay walls into the backfill soil. The L-type quay walls are expected to give economical benefits by reducing the cross-sectional area of the wall while maintaining its aseismatic efficiency as much as the classical caisson gravity quay wall. To confirm the effectiveness of the L-type structure, the geometry of L-type quay walls were varied for shaking table tests. And, to verify the influence of backfill soils on the seismic behavior of quay walls, additional shaking table tests were performed on the L-type quay wall after the backfill soils were replaced by gravels and light materials. As a result, it was found that L-type caisson quay walls are good earthquake resistant structures but increasing the length of bottom plate did not proportionally increase the effectiveness of the structure in its aseismatic performance. Replacing the backfill soils by the gravels and light materials, contrary to our expectation, was not an effective measure in improving the seismic performance of L-type caisson quay wall.

  • PDF

The Effects of Light and $CO_2$ on the Changes of Electrical Potential Difference in Isolated Epidermis and Intact Leaves of Commeina communis L

  • Lee Joon-Sang
    • 환경생물
    • /
    • 제23권3호
    • /
    • pp.221-227
    • /
    • 2005
  • The effects of light and $CO_2$ on the electrophysiological characteristics of guard cells in the intact leaf and isolated epidermis have been investigated. Fast hyperpolarization of guard cell apoplastic PD in the intact leaf was recorded reaching up to around 7 mV and 20 mV in response to light and $CO_2$. Whenever the experiments were attempted with isolated epidermis, there was no response to light and $CO_2$. In order to determine the influence of the mesophyll cells, the apoplastic PD of guard cells in isolated epidermis was measured in the presence of the mesophyll supernatant or the control medium. The apoplastic PD in isolated epidermis was hyperpolarized to -7mV, changing from -22mV to -29mV at 40 min. But, when isolated epidermis was incubated with the supernatant from mesophyll cells incubated in the light, the apoplastic PD in isolated epidermis was hyperpolarized to -19 mV, changing from -22 mV to -40.5 mV. $CO_2$ also caused a change of 0.1 to 0.3 pH unit in the intact leaf. However, this change was absent in isolated epidermis. A vibrating probe was used to detect the change in electrical currents at the surface of excised intact leaves and isolated epidermis. The reading of excised intact leaves in the dark was $0.5\muA\;cm^{-2},$ remaining steady until illuminated. Light increased the current on the surface of excised leaves to about $0.8\muA\;cm^{-2},$. However, light had no effect in the current on the surface of isolated epidermis. Apoplastic pH changes across the stomatal complex in response to light and dark were measured both in the intact leaves and isolated epidermis over the same time period using pH micro-electrodes. The guard cell wall of intact leaf was acidified to 2.5 pH unit, falling from pH 7.5 to pH 5.0 in the first 10 min. in the light. At the same time the guard cell wall pH of isolated epidermis fell from pH 7.5 to pH 7.0 at 10 min. The guard cell wall pH of isolated epidermis incubated in the mesophyll supernatant fell from pH 7.6 to pH 6.7 at 10 min. Likewise, It could be imagined that an electrical signal, chemicals and hormones propagated from the mesophyll in response to light and $CO_2$ could control a fast stomatal response.

Mechanical behavior test and analysis of HEH sandwich external wall panel

  • Wu, Xiangguo;Zhang, Xuesen;Tao, Xiaokun;Yang, Ming;Yu, Qun;Qiu, Faqiang
    • Advances in concrete construction
    • /
    • 제13권 2호
    • /
    • pp.153-162
    • /
    • 2022
  • Prefabricated exterior wall panel is the main non-load-bearing component of assembly building, which affects the comprehensive performance of thermal insulation and durability of the building. It is of great significance to develop new prefabricated exterior wall panel with durable and lightweight characteristics for the development of energy-saving and assembly building. In the prefabricated sandwich insulation hanging wall panel, the selection of material for the outer layer and the arrangement of the connector of the inner and outer wall layers affect the mechanical performance and durability of the wall panels. In this paper, high performance cement-based composites (HPFRC) are used in the outer layer of the new type wall panel. FRP bars are used as the interface connector. Through experiments and analysis, the influence of the arrangement of connectors on the mechanical behaviors of thin-walled composite wall panel and the panel with window openings under two working conditions are investigated. The failure modes and the role of connectors of thin-walled composite wallboard are analyzed. The influence of the thickness of the wall layer and their combination on the strain growth of the control section, the initial crack resistance, the ultimate bearing capacity and the deformation of the wall panels are analyzed. The research work provides a technical reference for the engineering design of the light-weight thin-walled and durable composite sandwich wall panel.

수침목재의 재질분석에 관한 연구-미시형태적 변화를 중심으로 (MICROMORPHOLOGICAL ASPECTS OF HARDWOODS DETERIORATED IN THE SEA-WATER FROM WRECKED SHIP'S TIMER)

  • 김윤수;최광남
    • 보존과학연구
    • /
    • 통권7호
    • /
    • pp.246-264
    • /
    • 1986
  • Micoromorphological alterations of sea-waterlogged woods by marinemicro-oragnisms were investigated by the light and scanning electron microscopy as a part of serial investigations on the shipwrecked materials which were excavated at the sea shore of Wando-Kun, southern coast of Korea in 1984.Deterioration of sea-waterlogged wood by marine microorganisms were varied with the wood species. The degree of deterioration even in the same wood specieswas different according to the part where it was in mud of sea-water. However, the resistance of Torreya nucifera over the marine organisms was marked. Deterioration in cell wall may be classified into three types; thinning of cell wall, separation of secondary wall from compound middle lamella and tunneling of cell wall. Thinning and separation were frequently observed, while the tunneling was rare. Among the wood cell elements of hardwoods, vessel wall was the least deteriorated. The difference degree of degradation of cell wall constituents and the accumulation of inorganic substances in cell lumen indicate that some factors to be considered for the conservation treatment were discussed. The kinds of marine microorganisms invading and/or inhabiting in wrecked wooden ship were also discussed.

  • PDF

건축 구조물에의 차음시트 적용 (Effect of Sound Damping Sheet on Sound Transmission Loss in Building Structure)

  • 김상렬;김재승;김현실;강현주;마경업;한문성
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1723-1728
    • /
    • 2000
  • This paper deals experimentally with the effect of the sound-damping sheet on building wall system; brick wall, light wall panel, and gypsum board. Experimental results show that when the sound-damping sheet is attached on wall systems, the mass and/or damping effects result in increasing of STL of wall system depending on the characteristics of the original partition. It is pointed out that the performances of sound damping sheets must be presented with specific wall structures that applied, not by the sound transmission loss of the sheet itself.

  • PDF