• 제목/요약/키워드: Light Wall

검색결과 624건 처리시간 0.028초

Phytophthora capsici 균주와 토마토의 친화적, 불친화적 상호작용에 대한 광학 및 전자현미경적 연구 (A Light and Electron Microscopical Study of Compatible and Incompatible Interactions between Phytophthora capsici and Tomato (Lycopersicon esculentum))

  • 황재순;황병국;김우갑
    • 한국식물병리학회지
    • /
    • 제10권2호
    • /
    • pp.83-91
    • /
    • 1994
  • Stem tissues of tomato plants (cv. Kwanyang) inoculated with Phytophthora capsici were examined by light and electron microscopy to compare early cytological differences between comaptible and incompatible interactions of tomatoes with the fungus. Twenty four hours after inoculation, the compatible isolate S 197 colonized severely the epidermis, cortex, and xylem vessels of stem tissue, whereas only few fungal cells colonized the stem tissues inoculated with the incompatible isolate CBS 178.26. Fragmented plasma membrane, distorted chloroplast, degraded cell wall, remnants of host cytoplasm were early ultrastructural features of the damaged host cell observed both in the compatible and incompatible interaction, a number of vesicles were distributed in the space between fungal cell walls and plasma membrane. The degradation of host cell walls by P. capsici was more pronounced in the compatible than the incompatible interactions. The incompatible interactions of tomato cells with P. capsici were characterized by formation of host cell wall apposition in the cortical parenchyma cells, indicating that the apposition of electron-dense material from the host cell walls may function as a plant defense reaction to the fungus. The fungal cells encased by wall appositions had abnormal cytoplasm and separated plasma membranes. The haustorium which formed from the fungal hyphae did not further penetrate through the host wall apposition and cytoplasmic aggregation, especially in the incompatible reactions. In contrast, the haustorium of the compatible isolate S 197 was not encased by wall appositions.

  • PDF

실내 3D 입체 면광원 조명연출에 관한 감성평가 모형 연구 (Sensibility Evaluation Model Research as to The Three-dimensional Surface Light Source set In The Interior)

  • 이진숙;박지영;정찬웅
    • 조명전기설비학회논문지
    • /
    • 제29권6호
    • /
    • pp.14-26
    • /
    • 2015
  • This study has been conducted so as to analyse user's sensibility on lighting method, correlated color temperature and illumination by composing surface light source, which was projected onto a unit side of interior wall, ceiling and floor. 1) As an analyzed results of the sensibility images, it showed that the "snug & tender" value had got higher when the correlated color temperature got lower. And the "energetic, cheerful" value had got higher when the level of illuminance got lower. Furthermore, the "unusual, unique" showed higher value on the illuminated floor circumstance. Finally, the higher correlated color temperature had been, "energetic, cheerful" value also got higher. 2) As a result of multi-regression analysis, it was found that 3000K and 100lx had the biggest influence on 'snug' image while 5,500K, 500lx had the biggest influence on 'energetic' image. In addition, it was found that the illuminated floor had a big influence on 'unusual' image while 500lx had the biggest influence on 'refined' image.

Impacts of Different Urban Surfaces on Summer Thermal Performance

  • Jo, Hyun-Kil;Wu, Qian
    • 한국환경과학회지
    • /
    • 제24권6호
    • /
    • pp.819-826
    • /
    • 2015
  • This study measured temperatures and albedos of urban surfaces for different colors and materials during summer, and calculated the energy budget over different urban surfaces to find out the thermal performance affecting the heat built-up. The study selected six surface colors and 13 materials common in urban landscape. Their surface temperatures (Ts) and albedos were measured at a given time interval in the daytime from June to August. Average Ts over summer season for asphalt-colored brick was $4.0^{\circ}C$ higher than that for light red-colored one and $9.7^{\circ}C$ higher than that for white-colored one. The Ts for artificial surface materials of asphalt paving, brown brick wall, and green concrete wall was $6.0^{\circ}C$ higher than that for natural and semi-natural ones of grass, grassy block, and planted concrete wall. There was the greatest difference of $16.3^{\circ}C$ at midafternoon in the Ts between asphalt paving and planted concrete wall. Average albedo over summer season of surface materials ranged from 0.08 for asphalt paving to 0.67 for white concrete wall. This difference in the albedo was associated with a maximum of $15.7^{\circ}C$ difference at midafternoon in the Ts. Increasing the albedo by 0.1 (from 0.22 to 0.32) reduced the Ts by about $1.3^{\circ}C$. Average storage heat at midday by natural and semi-natural surfaces of grass and grassy block was about 10% lower than that by artificial ones of asphalt, light-red brick, and concrete. Reflected radiation, which ultimately contributes to heating the urban atmosphere, was 3.7 times greater for light-red brick and concrete surfaces than for asphalt surface. Thus, surfaces with in-between tone and color are more effective than dark- or white-colored ones, and natural or semi-natural surfaces are much greater than artificial ones in improving the urban thermal environment. This study provides new information on correlation between Ts and air temperature, relationship between albedo and Ts, and the energy budget.

Analysis of light-frame, low-rise buildings under simulated lateral wind loads

  • Fischer, C.;Kasal, B.
    • Wind and Structures
    • /
    • 제12권2호
    • /
    • pp.89-101
    • /
    • 2009
  • The Monte Carlo procedure was used to simulate wind load effects on a light-frame low-rise structure of irregular shape and a main wind force resisting system. Two analytical models were studied: rigid-beam and rigid-plate models. The models assumed that roof diaphragms were rigid beam or rigid plate and shear walls controlled system behavior and failure. The parameters defining wall stiffness, including imperfections, were random and included wall stiffness, wall capacity and yield displacements. The effect of openings was included in the simulation via a set of discrete multipliers with uniform distribution. One and two-story buildings were analyzed and the models can be expanded into multiple-floor structures provided that the assumptions made in this paper are not violated.

광촉매 적용 감성콘크리트 시작품 현장적용 (Field Application of Protopype LEFC Applied With Photocatalys)

  • 김병일;오상근;박현호;김수연
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.152-153
    • /
    • 2021
  • Various types of panels can be designed using acrylic rods, which are materials that allow light to pass through existing concrete. After designing using people, animals and objects, a prototype was produced by mixing ultra-high-strength concrete, and taking care not to damage the fixed acrylic rod during pouring and demolding. Yun Dong-ju's free design of a figure and a researcher were inserted into the wall inside the interior space, and then the installation was completed on-site. For installation, a metal frame was installed on the temporary wall, which is a non-structural wall, and then a relatively heavy concrete panel was fixed using a structural sealant and then applied to the field.

  • PDF

강재지주 전면판 보강토 옹벽의 안정성 평가 (Stability Analysis of Reinforced Retaining Wall with Steel Supported Face)

  • 김기일;김병일;이영생;이순호
    • 대한토목학회논문집
    • /
    • 제31권2C호
    • /
    • pp.75-82
    • /
    • 2011
  • 최근 콘크리트 블록을 전면판으로 주로 사용하고 있는 기존의 블록식 보강토 옹벽과는 달리 경량의 강재를 지주로 이용하여 전면판의 자중을 감소시켜 안정성을 높이고 시공이 쉬운 보강토 공법이 개발되었다. 이 연구에서는 새로 개발된 보강토 옹벽의 안정성을 확인하기 위해 실제 크기의 현장시험을 수행하여 전면판에 발생하는 수평변위, 수평토압, 그리고 옹벽의 침하량 등을 계측기를 이용하여 측정하였다. 또한, 3차원 수치해석을 수행하여 현장시험결과와 수치해석결과를 비교 분석하였다. 현장계측결과 전면판 최대수평변위는 46mm(0.009H), 최대침하량은 21.5mm로 나타나 FHWA 기준을 만족하는 것으로 나타났다. 또한 현장계측결과를 수치해석결과와 비교 분석한 결과 새로운 보강토 공법은 충분한 안정성을 확보하는 것으로 나타났다.

Inorganic Polymer Concrete를 이용한 경량패널의 내화특성에 관한 실험적 연구 (Study on the Fire Resistance of Light Weight Inorganic Polymer Concrete Panel Wall)

  • 황지순;김우재;김대회;박동철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 추계 학술논문 발표대회
    • /
    • pp.205-206
    • /
    • 2011
  • 이노가닉 폴리머 콘크리트는 비소성 알카리 활성화 콘크리트의 일종으로 여러 가지 우수한 성능을 가지고 있으며, 그 중에서도 고온에서의 열적특성이 우수한 것으로 알려져 있다. 이에 따라, 이노가닉 폴리머 콘크리트를 이용한 경량패널을 제조하여, 소형가열로 내화시험을 측정한 결과 3시간 가열후 이면상승온도가 평균 82℃ 이하로 확인되어 공동주택의 내화벽체로 활용이 가능할 것으로 판단된다.

  • PDF

초광각 변환기를 이용한 전방위 조명 광학계의 설계 (Optical Design of an Omnidirectional Illumination System Using an Ultra Wide Converter)

  • 이주호;유재명
    • 한국광학회지
    • /
    • 제35권1호
    • /
    • pp.18-23
    • /
    • 2024
  • 미술관 등 전시 공간에서의 조명은 바닥보다는 주로 전시물이 붙어 있는 벽면에 비춰져야 한다. 일반적으로 사용되는 LED 조명은 LED에 확산판이 결합된 형태로서 각도별 배광 분포가 일정한 램버시안 광원에 가까우며, 수직 입사가 이뤄지는 바닥면에 조명이 집중된다. 따라서 이러한 일반적 형태의 조명 방법은 벽면을 조명하기에는 적합하지 않으며, 벽면에 조명을 집중시키기 위해서는 각도별 배광 분포 중 각도가 큰 영역에서의 광량이 커지도록 해야 한다. 본 연구에서는 광원에서의 발산각을 180도로 확산시키기 위해 초광각 변환기를 사용하는 조명 광학계에 대해 논의하고자 한다.

Via-hole 구조의 n-접합을 갖는 수직형 발광 다이오드 전극 설계에 관한 연구 (Study on the Electrode Design for an Advanced Structure of Vertical LED)

  • 박준범;박형조;정탁;강성주;하준석;임시종
    • 마이크로전자및패키징학회지
    • /
    • 제22권4호
    • /
    • pp.71-76
    • /
    • 2015
  • 최근 Light Emitting Diode (LED)의 효율을 높이기 위한 연구가 활발히 진행 되고 있다. 특히 소자 측면에서는 수평형 LED, 수직형 LED, via-hole 구조의 수직형 LED 등의 다양한 구조가 제시되었다. 본 논문에서는 시뮬레이션을 통해 via-hole 구조의 수직형 LED의 새로운 전극 디자인을 제시하였다. 기존 Via-hole 구조의 수직형 LED의 n-contact hole 주변에 전류가 밀집되는 문제점을 해결하면서 유효 발광면적을 극대화 시켜 소자 전체에 균일한 전류를 주입할 수 있는 소자 디자인에 대해 평가하였다. 시뮬레이션 결과를 바탕으로 최적의 전극 디자인을 실제 디바이스로 제작하여 기존의 via-hole 구조의 수직형 LED와 비교 분석하였다. 최적화된 디자인이 적용된 via hole type 수직형 LED의 경우 기존 디자인에 비해 350 mA 주입시 약 0.2 V의 Forward Voltage 감소하였지만 광 출력은 비슷하여 최종적으로 4.2%의 WPE (Wall plug efficiency)가 향상됨을 보였다.

경량 무기 발포패널을 적용한 커튼월의 성능평가 (Performance Evaluation of Curtain-Wall Applying Light-weight Inorganic Foam Panel)

  • 신현욱;송훈;추용식;이종규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.211-212
    • /
    • 2012
  • To prevent energy waste in buildings used heat insulator. Heat insulator materials can be classified inorganic and organic. The organic material is due to toxic gas emission, when a fire occurs. And it has lower water resistance. The inorganic material is heavy and worse thermal performance than organic materials. Technologies on energy saving and materials used in curtain walls have progressed with increase of high-rise and large buildings. However, there is little study to explain fire resistance performance of the curtain walls. This study focused on evaluation of the physical properties of light-weight inorganic foam panel for using industrial by-products materials and performance evaluation by mock up test.

  • PDF