• 제목/요약/키워드: Light Uniformity

검색결과 358건 처리시간 0.029초

Evaluation of Light Intensity and Uniformity of LEDs for Protected Crop Production

  • Kim, MunJung;Choo, YounKug;Kim, YongJoo;Chung, SunOk
    • Agribusiness and Information Management
    • /
    • 제6권1호
    • /
    • pp.37-44
    • /
    • 2014
  • This study was conducted to evaluate light intensity and uniformity of two SMD (surface-mount device) type LEDs for protected crop production. A low-power (0.1 W) and a high-power (1 W) LEDs were selected and the intensity and uniformity was evaluated at different vertical (height) and horizontal (distance) intervals. When the horizontal interval of the LED bar was fixed, the light intensity increased and the uniformity decreased as the height decreased. At the 30~40 cm heights, 20~30% of the area showed $200{\pm}20{\mu}molm^{-2}s^{-1}$. As the horizontal distance of the LED bars increased, while the uniformity increased as well, the light intensity decreased. At the distances of 6~10 cm, 17~23% of the area showed $200{\pm}20{\mu}molm^{-2}s^{-1}$. When the LED bars were added to the sides, the light intensity and uniformity were generally improved. Results showed that the light intensity and uniformity depended on the height and interval of the LED bulbs; therefore, optimum arrangement for the crops interested should be determined through experiments.

Overall Illuminance Uniformity of IRED Lighting in Nighttime CCTV

  • Sa-Gong, Geon;Park, Yung-Jun;Park, Jung-Je;Lee, Suho
    • Transactions on Electrical and Electronic Materials
    • /
    • 제18권1호
    • /
    • pp.35-41
    • /
    • 2017
  • This study looks at optimizinge light redistribution to improve the overall illuminance uniformity of commercial IRED modules. To obtain uniform illumination over a prescribed rectangular area, a freeform surface lens was evaluated using TracePro. The LED light overall illuminance uniformity regulated in KSC 7658 was verified using Relux software. Experimental test results showed 0.81 overall illuminance uniformity for rectangular light distribution of LED lights having a radiation angle of $80^{\circ}$. After fabricating prototype IRED lights based on these simulation results, illuminance performance was observed when used as actual IRED lighting with a nighttime CCTV system. Image observation photographs of the prototype $80^{\circ}$ rectangular IRED lights confirmed that object images can be seen clearly owing to high overall illuminance uniformity, and that dark regions of the CCTV screen were not shown.

광선추적법을 사용한 가로등 반사판의 최적설계에 관한 연구 (Study of Optimized Reflector Design for Road Light Using Ray-Tracing Method)

  • 최대섭;한정민;심용식;정찬웅;오선
    • 전기학회논문지P
    • /
    • 제58권3호
    • /
    • pp.347-350
    • /
    • 2009
  • In this study, it was studied about the improved road light design for drivers and pedestrians using forward or reverse ray-tracing method. Many of conventional road lights are not suitable for drivers and pedestrians because it has some serious problems such as glare effect or randomicity of illuminated areas. It was oriented from customary design method which was pointed at simple target such as luminance or electrical power. But it was not truth any more that the high luminance or electrical power consumption mean more bright and good road light. We studied ray-tracing method for road light reflector design to get the several goals. It means that good road light has easy for drivers and pedestrians eyes and illuminating objects on the road clearly. So, we set the design targets such as uniformity on the road area per one road light, shading angles and continuous luminance uniformity on the long distance road. We designed ideal road light conditions using ray-tracing method. We set the height of drivers and pedestrians eyes and calculated design guideline to make above design targets. Then we designed road light reflector using reverse ray-tracing method. And we achieved same luminance on the road almost half power consumption because we reduced loss of light. We achieved ideal design guide as 75 degrees of shading angles and 0.5 of luminance uniformity on the road area. It is superior than conventional road light ability such as 0.35 of luminance uniformity of 400 watts power consumption lamp. Finally, we suggested reflector design for 250 watts power consumption CDM Iight source.

도광판의 균일도 및 휘도에 사출성형조건이 미치는 영향 (The Effects of Injection Molding Conditions on Uniformity and Brightness of Light Guide Plate)

  • 이성희;김선우;이훈석;김종덕
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1609-1612
    • /
    • 2005
  • The effects of injection molding conditions on the uniformity and brightness of light guide plate(LGP) with micro-patterns were investigated in the present study. An injection molding system for stampers with mirco-pattern was designed and manufactured to perform experiment. Variations of injection molding speed, mold and melt temperature for LGP were considered in this work. Also, injection molding characteristics of LGP were investigated by numerical analysis using plastic injection molding commercial code. It was shown that injection molding conditions such as injection speed, melt temperature and mold temperature can have an effect on the uniformity and brightness of light guide plate.

  • PDF

소형 LCD 도광판의 사출성형에 관한 연구 (2) : 공정조건이 휘도에 미치는 영향 (A Study on the Injection Molding for the Light Guide Plate of a Small Sized LCD (2) : Influences of Processing Conditions on the Brightness)

  • 이호상
    • 소성∙가공
    • /
    • 제11권4호
    • /
    • pp.341-348
    • /
    • 2002
  • For the light guide plate of the TFT-LCD, there have been increasing demands for higher brightness, thin and light-weight design, and lower power consumption. To meet these demands, a micro-prism-type frontlight that integrates a prismatic sheet and a light-guiding plate has been developed. In this paper, the influences of processing conditions on the brightness were studied lot the injection molding of the light guide plate. Based on the experiment with an actual mold, the design of experiments and the neural network theory were used lot choosing the optimal processing parameters to increase the brightness and the uniformity. The verification experiment also showed that the brightness and the uniformity were increased dramatically with the chosen processing conditions.

LCD 도광판 두께에 따른 휘도 및 잔류응력에 관한 연구 (A Study of Brightness and Residual Stresses Depending on Thickness of LCD Light Guide Plate)

  • 이중원;박명균;김정훈
    • 한국정밀공학회지
    • /
    • 제25권9호
    • /
    • pp.38-44
    • /
    • 2008
  • Light guide plate is one of most important components which are composed of back light unit, affecting the quality and performance of LCD. Average brightness and uniformity are especially key factors for designing the light guide unit. These qualities are affected and controlled by the pattern being attached to the back of light guide unit. In order to obtain high brightness and uniformity the optimized pattern design is adopted for LGP. In this study, optimized molding condition for LGP with 0.4 mm thickness was obtained by using the Moldflow simulation software and the optimized pattern for better brightness uniformity was designed for the thickness of the 0.4 mm by trial and error method. The brightness was measured for the different LGP thicknesses and the residual stress analysis was performed for 0.4 mmthickness by the photoelasticity and the results are compared with 0.5 mm, 0.6 mm thickness.

Development of Awning System using Light Shelf - Focusing on the light environment and lighting energy reduction performance improvement -

  • Jeong, Jinsoo;Lee, Heangwoo;Seo, Janghoo;Kim, Yongseong
    • KIEAE Journal
    • /
    • 제17권3호
    • /
    • pp.5-13
    • /
    • 2017
  • Purpose: Various studies have been performed to address the issue of increased energy use by buildings. In particular, research on complex envelopes that combines diverse envelope element techniques is currently in progress in the building sector. The present study aimed to develop an awning system using a light shelf, and to verify its validity through performance evaluation. Method: In the present study, a testbed was established for the performance evaluation of the awning system using a light shelf, and the uniformity ratio and lighting energy consumption were compared and analyzed relative to those with no awning and light shelf installation (Case 1), awning installation (Case 2), and light shelf installation (Case 3). Result: 1) In the present study, an awning system using a light shelf (Case 4) where an opening is made on the awning screen and natural light can be introduced through the light shelf located at the bottom was developed. 2) The optimum standard for Case 4 obtained through the performance evaluation was a 0.6m lighting length and a 2m extension length at a light shelf angle of $30^{\circ}$. 3) Case 4 with the optimum standard had a 5.5% lower uniformity ratio than Case 2, but had a higher uniformity ratio than Case 1 and Case 3. 4) Case 4 with the optimum standard showed 13.3%, 44.6%, and 0%~8.7% lighting energy reductions compared to Case 1, Case 2, and Case 3, respectively. 5) Based on the above results, Case 4 suggested in the present study was found to be effective for indoor light environment improvement and lighting energy reduction.

50W급 LED 보안등용 조명광학계 개발 (Development of Optical System for 50W LED Security Lamp)

  • 정병조;장성환;노용기
    • 한국산학기술학회논문지
    • /
    • 제13권1호
    • /
    • pp.296-305
    • /
    • 2012
  • 본 연구에서는 기존 LED 보안등의 LED 광원 직진성에 의한 눈부심 현상을 개선하고, 조도 균제도를 높게 유지하며, 회전 대칭이 아닌 편축으로 긴 배광 분포를 가지도록 하여 LED 보안등 간에 생기는 광 공핍현상을 해결할 수 있는 보안등용 LED 2차 렌즈를 개발하였다. 개발 광학계는 보안등용 조명 기준에 만족하도록 설계하였으며, 렌즈의 형태는 단일 렌즈로 조명 설계 및 해석 프로그램을 이용한 설계와 분석을 통해 최적화를 하였다. Mock-up을 제작하여 실제 측정을 통해 조도 측정 데이터와 조도 균제도 데이터를 확보하였다.

레이저 가공에 의한 백라이트 도광판 성능 향상 (Improvement of Light Guide Panel Performance by Laser Patterning)

  • 김영섭;김태훈;박소희;최영희;최은서;신용진
    • 한국레이저가공학회지
    • /
    • 제10권1호
    • /
    • pp.29-34
    • /
    • 2007
  • We propose a novel application of laser engraving to patterning of light guide panel (LGP) for backlight. The feasibility of three-dimensional engraved pattern in the LGP was verified by measuring brightness and uniformity. To improve the overall uniformity, we have modified proposed patterns and found improved design for patterns. The tailoring of pattern by using laser engraving method could endow the controllability of uniformity. The proposed LGPs are more efficient in both average brightness and uniformity of illumination than the conventional LGPs which have surface pattern on the panel.

  • PDF

광투사 방법을 이용한 가로등 디자인 개선 (Improved Road light Design using Ray-tracing method)

  • 최대섭;한정민;박성태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.140-143
    • /
    • 2008
  • In this study, it was studied about the improved road light design for drivers and pedestrians using ray- or reverse ray-tracing method. Many of conventional road lights are not suitable for drivers and pedestrians because it has some serious problems such as glare effect or randomicity of illuminated areas. It was oriented from customary design method which was pointed at simple target such as luminance or electrical power. But it was not truth any more that the high luminance or electrical power consumption mean more bright and good mad light. We studied ray-tracing method for road light reflector design to get the several goals. It means that good road light has easy for drivers and Pedestrians eyes and illuminating objects on the road clearly. So, we set the design targets such as uniformity on the road area per one road light, shading angles and continuous luminance uniformity on the long distance road. We designed ideal road light conditions using ray-tracing method. We set the height of drivers and pedestrians eyes and calculated design guideline to make above design targets. Then we designed road light reflector using reverse ray-tracing method. And we achieved same luminance on the road almost half power consumption because we reduced loss of light. We achieved ideal design guide as 75 degrees of shading angles and 0.5 of luminance uniformity on the road area. Finally, we suggested reflector design for 250 watts power consumption CDM light source.

  • PDF