• Title/Summary/Keyword: Light Stimulus

Search Result 125, Processing Time 0.029 seconds

Eyeblinks, EP Augmenting / Reducing and Personality (눈깜작임, 증감뇌유발전위와 성격의 상호관계)

  • Lee, Sung-Hoon;Haier, Richard J.
    • Sleep Medicine and Psychophysiology
    • /
    • v.1 no.2
    • /
    • pp.156-162
    • /
    • 1994
  • Objectives: Eyeblinking varied depending on individual cognitive abilities or personality traits thought to related to brain mechanisms of sensory modulation. This study explored whether personality traits are related to the rate of eye blinks and how eyeblink and evoked potential augumenting-reducing(EPAR) interact Methods: Forty four students were studied with EPAR topography to explore how eyeblinks, personality and EPAR interact The Zuckerman Sensation Seeking Scale(SSS) and Eysenck Personality Questionnaire(EPQ) were used as personality measured by a stimulus response program during EP study. Results: Rate of blink increased as intensity of light increased. The General(GEN), Thrill and Adventure Seeking(TAS), Experience Seeking(ES) and Disinhibition(DS) subscales in SSS and Extraversion-Introversion(E) subscale in EPQ showed significant negative correlations with number of eyeblinks in the hightest intensity of light, whereas Neuroticism(N) subscales in EPQ showed a positive correlation. Correlation between number of eyeblinks with the brightest light and EPAR slope varied topographically. The strongest positive correlation was noted in right posterior temporal area. Conclusion: High sensation seekers blinked significantly fewer times than lower sensation seeker did. Higher personality correlations with eyeblink than with EP may imply that the eyeblink works as a primary filter since it is more directly related to central mechanisms of sensory modulation than EP. The right posterior temporal area may play an important role in modulation of visual stimuli.

  • PDF

The Effects of Eye Lateralization on Transient Evoked Otoacoustic Emissions of Auditory Function (측방 눈 주시가 유발이음향방사 청각기능에 미치는 영향)

  • Joo, Seokhee
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.7 no.4
    • /
    • pp.131-140
    • /
    • 2019
  • Purpose : The purpose of this study was to investigate the interrelationship between eye movement and auditory function through the effects of eye lateralization on transient evoked otoacoustic emissions of auditory function. Methods : 25 subjects with complete set of ears were used in this study, which composed of 12 males and 13 females with pure tone threshold of below 25 dB without otolaryngology were evaluated. Each of the patient has a visual acuity of greater than 1.0 after correction, and has no problems with eye disease, eye movement, and human parallel system. In a dark silent room, the subjects sat on a chair with their heads fixed on a headrest. The tests were performed by asking the patients to look at a fixed red light dot on a light bar in front of them. This light was directed to the front, right and left sides of the subject at an angle of 40 ° In the presence of the stimulus sound in the ipsilateral ear, the transient evoked otoacoustic emissions of the ipsilateral ear was measured at the straight, right and left fixation. In order to evaluate the transient evoked otoacoustic emissions through the efferent auditory pathway, the transient evoked otoacoustic emission values of the contralateral ear were measured at the straight, right and left fixation. These measurements were taken at frequencies of 1 kHz, 1.4 kHz, 2.0 kHz, 2.8 kHz and 4 kHz, respectively. Results : Transient evoked otoacoustic emissions caused by lateral movement of the eye showed significant changes at 1.4 KHz and 2 KHz of the afferent pathway of the ipsilateral ear. Also, significant changes were observed at 1.4 KHz and 4 KHz of the efferent pathway of the contralateral ear. Conclusion : These results indicated that there is a close relationship between eye movement and auditory cochlea. In the future, further studies considering more diverse subjects and age groups will be needed.

The Method of Optical Stimulus by Reticle for pH Image Detection using LAPS (LAPS를 위한 pH 이미지 검출용 격자무늬 광자극 방법)

  • Bae, S.K.;Kang, S.W.;Cho, J.H.
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.6
    • /
    • pp.317-327
    • /
    • 2001
  • In this paper, we proposed a new detection method of pH image to effectively measure a 2-dimensional pH distribution of test materials by irradiating an frequency modulated light to LAPS using a reticle. It could measure simultaneously signals in one line by applying a modulated light having difference frequency for each pixel using a frequency modulating reticle, and calculating an amplitude with respect to a frequency component by the light source. To experiment the proposed method, we designed and implemented a reticle considering of a LAPS's characteristic, and reconstructed an image by frequency analysis using the implemented reticle and test pattern image. As a result, we verified that the proposed method using the reticle was able to detect 30 times faster for a $30{\times}30$ pixels pH image having a PSNR of 22-24 [dB] than conventional method.

  • PDF

Measuring System of Visual Evoked Potential (VEP) in Mice using BioPAC Modules (BioPAC 모듈을 이용한 마우스 시각유발전위 측정 시스템 확립)

  • Lee, Wang Woo;Ahn, Jung Ryul;Goo, Yong Sook
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.1
    • /
    • pp.16-24
    • /
    • 2017
  • For the development of feasible retinal prosthesis, one of the important elements is acquiring proper judging tool if electrical stimulus leads to patient's visual perception. If evoked potential to electrical stimulus is recorded in primary visual (V1) cortex, it means that the stimulus effectively evokes visual perception. Therefore, in this study, we established VEP recording system on V1 cortex using BioPAC modules as the judging tool. And the measuring system was evaluated by recording VEP of mice. After anesthesia, normal mice (C57BL/6J strain; n = 6) were secured to stereotaxic apparatus (Harvard Apparatus, USA). For the recording of VEP, the stainless steel needle electrode (impedance: $2-5k{\Omega}$) was positioned on the surface of the cortex through the burr hole at 2.5 mm lateral and 4.6 mm caudal to bregma. DA 100C and EEG 100C BioPAC modules were used for the trigger signal and VEP recording, respectively. When left eye was blocked by black cover and right eye was stimulated by flash light using HMsERG (RetVet Corp, USA), VEP response at left V1 cortex was detected, but there was no response at right V1 cortex. Amplitudes and latencies of P2, N3 peaks of VEP recording varied according to the depths of the electrodes on V1 cortex. From the surface upto $600{\mu}m$ depth, amplitudes of P2 and N3 increased, while deeper than $600{\mu}m$, those amplitudes decreased. The deeper the insertion depth of the electrode, the latency of N1 peaks tends to be delayed. However, there was no statistically significant difference among the latencies of P2 and N3 peaks (P > 0.05, ANOVA). Our VEP recording data such as the insertion depth and the latency and amplitudes of peaks might be used as guidelines for electrically-evoked potential (EEP) recording experiment in near future.

The Effect of Non-ivasive Baihui($GV_{20}$) Point Stimulus by 'Dong Chu Gold Chim' on Electroencephalogram (동추금침(東樞金鍼)에 의한 비침습적 백회혈(百會穴) 자극이 뇌파에 미치는 영향)

  • Ma, Jeung-Hun;Han, Chang-Hyun;Park, Soo-Jin;Choi, Woo-Suk;Lee, Sang-Nam;Park, Ji-Ha
    • Journal of Acupuncture Research
    • /
    • v.27 no.1
    • /
    • pp.87-100
    • /
    • 2010
  • Background : Recently a discussion about Qi including a study about the effect or the theory of acupuncture is getting prevailing in various angles. In most of studies about acupuncture stimulus, 'Filiform acupuncture'(毫鍼) is used. A study about Nine kinds of acupuncture(九鍼), except 'Filiform acupuncture'(毫鍼) has not been reported yet, and there is no study about using a special acupuncture made for controling Qi either. Objectives : 'Dong Chu Gold Chim(DCG-chim, 東樞金鍼)' can be used for patients who are scared of a pain because it is a medical Qi-gong tool and non-invasive stimulus one. To assess a effect of Qi-gong operation using DCG-chim objectively Methods : The present study was performed to elucidate the effects of DCG-chim stimulation of an acupuncture point Baihui($GV_{20}$) on the Electroencephalogram(EEG). Twenty healthy subject were treated with DCG-chim one time accompanied by the light and vertical pressure and EEG were measured during five minutes for three times (before, during and after treatment). The EEG results of DCG-chim treatment were compared with those of 'Filiform acupuncture(毫鍼)'. Results : EEG power spectra changed significantly after both kind of acupuncture stimulation. Significant increase of $\alpha$ wave and decrease of $\beta$ wave were observed but interestingly, Mid-$\beta$ and SMR of $\beta$ wave which mean the state of concentration were increased with statistically significant. According to these results, DCG-chim stimulation of Baihui($GV_{20}$) seems to lead to relaxation with antianxietic effect and improvement of concentration at the same time. Conclusions : It would be expected that the doctor can apply DCG-chim for treating anxiety, tension, symptom caused by stress and also can use it clinically for patients who have needlphopia or children as a non-invasive procedure. It is suggested that additional studies about the effect of DCG-chim on other acupuncture points and comparison study about the effect of DCG-chim with those of the finger-pressure treatment using other tool should be done in the future.

Analysis on Multi-Components of Neurotransmitter Release in Response to Light of Retinal ON-Type Bipolar Cells (망막 ON형 쌍극세포의 광응답에 따른 다중성분의 전달물질 방출에 관한 해석)

  • Jung, Nam-Chae
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.14 no.4
    • /
    • pp.222-230
    • /
    • 2013
  • Retinal bipolar cells according to the light stimulus respond to potential slowly, emit neurotransmitter release(glutamine acid) to depend on membrane potential. In this paper, the several physiological information on neurotransmitter release mechanism in the presynaptic terminal of the ON-type bipolar cells are incorporated into the formula model. The source of fast components and slow components of neurotransmitter release was arranged in parallel, this model was able to reproduce the membrane potential and intracellular $Ca^{2+}$ concentration dependence of neurotransmitter release faithfully. In addition, because the fast releasable components of neurotransmitter was represented by the membrane potential dependence of trapezoid type, whereas the slow releasable components was represented by the membrane potential dependence of a bell type, $Ca^{2+}$ concentration rise in intracellular is suppressed by $Ca^{2+}$ buffer to reduce slow releasable components, it was confirmed that the membrane potential dependence of neurotransmitter release was characteristics of a trapezoid type. And, in the light response of ON type bipolar cell, the result of the simulation of the neurotransmitter release caused by the components of transient and persistent was that the start of light response occurred the fast release of neurotransmitter, it was confirmed that the transient component and persistent component of the light response occurred the slow release. It was confirmed that the later of persistent component of the light response occurred due to the continuous release by synaptic vesicle supplemented from the storage pool.

Response of Electrocardiogram of Nile tilapia, Oreochromis niloticus to Light Stimuli (광자극에 대한 역돔의 심전도)

  • Kim, Young-Ki;Yang, Yong-Rhim
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.38 no.3
    • /
    • pp.217-225
    • /
    • 2002
  • The authors examined the response of electrocardiogram(ECG) of Nile tilapia, Oreochromis niloticus [Linnaeus] to light stimuli. The experiments were performed in such a way that three levels of light stimuli(10, 100 and 400 lu$\chi$) were given to fishes with an electrode inserted into their bodies and then their ECGs were recorded continuously for 60 minutes in 16~18$^{\circ}C$. The results which are divided into by day and by night and then analyzed by fishes' conditions are as follows; 1. Nile tilapias reached a stable condition 3 minutes after anesthesia. In stable condition, the heart rate average was 47.6beat/min by day and 45.1beat/min by night. And the action potential average was 1.0.4$mutextrm{V}$ by day and 1.24$mutextrm{V}$ by night. 2. The heart rate average by three levels of light stimuli was, \circled1 In stimulus condition, in case of 10 lu$\chi$ 39.7beat/min by day and 38.2beat/min by night, in case of 100 lu $\chi$8.7beat/min by day and 36.9beat/min by night, and in case of 40.0. lux 36.8 beat/min by day and 35.8beat/min by night. \circled2 In recovery condition, in case of 10 lu$\chi$ 47.1beat/min by day and 46.0beat/min by night, in case of 100 lu$\chi$ 47.2beat/min by day and 45.6 beat/min by night, and in case of 400 lu$\chi$ 48.1beat/min by day and 46.6beat/min by night. 3. The action potential average by three levels of light stimuli was, \circled1 In stimulus condition, in case of 10 lu$\chi$ 1.22$mutextrm{V}$ by day and 0.71$mutextrm{V}$ by night, in case of 100 lu$\chi$ 0..63$mutextrm{V}$ by day and 0.90$mutextrm{V}$ by night, and in case of 400 lu$\chi$ 1.39$mutextrm{V}$ by day and 1.63$mutextrm{V}$ by night \circled2 In recovery condition, in case of 10 lu$\chi$ 1.26$mutextrm{V}$ by day and 1.59$mutextrm{V}$ by night, in case of 100 lu$\chi$ 2.63$mutextrm{V}$ by day and 3.65$mutextrm{V}$ by night, and in case of 400. lu$\chi$ 2.52$mutextrm{V}$ by day and 3.67$mutextrm{V}$ by night.

Response of Electrocardiogram of Mirror Carp, Cyprinus carpio to Light Stimuli (광 자극에 대한 향어의 심전도)

  • 양용림;김영기
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.2
    • /
    • pp.124-132
    • /
    • 2001
  • The authors examined the response of electrocardiogram (ECG) of Mirror carp, Cyprinus carpio [Linnaeus] to light stimuli. The experiments were performed in such a way that three levels of light stimuli (10, 100, and 400 lux) were given to fishes with an electrode inserted into their bodies and then their ECGs were recorded continuously for 60 minutes. The results which are divided into by day and by night and then analyzed by fishes conditions are as follows : 1. Mirror carps reached a stable condition 5 minutes after anesthesia. In this condition, the average heart rate was 64.9 beat/min by day and 65.3 beat/min by night. And the average action potential was 36.9 nV by day and 32.9 nV by night. 2. The average heart rate by three levels of light stimuli was, 1) In a stimulus condition, in case of 10 lux 68.7 beat/min by day and 46.0 beat/min by night, in case of 100 lux 53.4 beat/min by day and 44.1 beat/min by night, and in case of 400 lux 53.2 beat/min by day and 40.1 beat/min by night. 2) In a recovery condition, in case of 10 lux 67.9 beat/min by day and 57.2 beat/min by night, in case of 100 lux 68.8 beat/min by day and 61.0 beat/min by night, and in case of 400 lux 69.6 beat/min by day and 63.6 beat/min by night. 3. The average action potential by three levels of light stimuli was, 1) In a stimulus condition, in case of 10 lux 59.1 nV by day and 24.0 nV by night, in case of 100 lux 26.8 nV by day and 45.6 nV by night, and in case of 400 lux 71.7 nV by day and 14.4 nV by night. 2) In a recovery condition, in case of 10 lux 38.8 nV by day and 27.3 nV by night, in case of 100 lux 29.0 nV by day and 39.3 nV by night, and in case of 400 lux 66.4 nV by day and 21.4 nV by night.

  • PDF

Study on Human Physiological Responses to Emotional Lighting System using LED Flat Lighting (LED 면조명을 이용한 감성조명시스템의 인체 생리학적 반응에 관한 연구)

  • Kim, Kyung-Tae;Oh, Seung-Yong;Yu, Mi;Yu, Chang-Ho;Kwon, Tae-Kyu
    • Science of Emotion and Sensibility
    • /
    • v.17 no.3
    • /
    • pp.29-38
    • /
    • 2014
  • The purpose of this study was to verify human physiological responses to emotional lighting system using LED (light emitting diode) flat lighting. Subjects were ten males in their twenties without medical history to eyes. Colors of LED lighting are red, orange, yellow, green, blue, purple and colorless (white). They were stimulated by LED lighting for 5 minutes. We measured body temperature, heart rate variability (HRV) and electroencephalogram (EEG) before and after color stimulus. In case of EEG analysis, relative power ${\alpha}$ wave ratio decreased in the groups of colorless, red and orange color light. Also, sympathetic nerve was more activated than parasympathetic nerve and the body temperature was increased in the groups of colorless, red, orange, yellow color light. On the other hand, relative power ${\alpha}$ wave ratio increased and parasympathetic nerve was more activated than sympathetic nerve and the body temperature was decreased in the groups of green, blue and purple color light. The results imply that the LED color lighting system in the realistic experiment environment. In the future, studies with compounded both colors and modes according to situation or auditory as nature sound or olfactory as aroma will be required.

The Image Evaluation for Tone Variation in Same Color of Clothing and Lipstick of the Clothing Wearers (의복과 립스틱의 동일색상 톤 변화에 따른 의복착용자의 이미지 평가)

  • Jeong, Su-Jin
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.9 no.2
    • /
    • pp.15-30
    • /
    • 2007
  • The purpose of this study is to investigate the effect of makeup, clothing tone and clothing style on wearer's with same color coordination of lipstick and clothing. The experimental materials developed for this study were a set of stimulus and response scales (7-point scale semantic). The stimuli were 64 color pictures were manipulated by computer simulation. This experiment design was $2{\times}2{\times}4{\times}4$ factorial design. The stimuli were a set of eyeshadow color(brown), clothing style (formal style of Jacket / skirt and casual style of cardigan / pants), lipstick and clothing color (red and orange), lipstick tone(vivid, light, dull and dark), clothing tone(vivid, light, dull and dark). The subjects of this research were 384 female undergraduates living in Gyeongsangnam-do. The investigation was carried out at a lecture hall at the time between 10 a.m. and 3 p.m. in May 2006. The data were analyzed using SPSS program. Factor analysis, 4-way ANOVA, t-test, and Duncan test were used as analysis methods. Image factors according to variation of clothing style, clothing color, and makeup color are composed of 4 different dimensions (visibility, attractiveness, tenderness, and stability). In dimension of the visibility, the image was perceived to be glowing and luxurious regardless of lipstick tone and lipstick color in the case of the vivid tone clothing. According to the variation of clothing style, clothing color and tone, makeup color composed of eyeshadow color, lipstick color and tone, it was investigated that the images for a clothing wearer were expressed diversely, were shown differently in image dimensions, and could be produced to different images. The analysis data for images according to the combination of makeup and clothing color, tone, and style thus provide basic material for image consulting or color coordination.

  • PDF