• Title/Summary/Keyword: Light Sensitivity

Search Result 614, Processing Time 0.029 seconds

The Intrusion Sensor Using the Variations of Speckle Patterns (스페클 패턴을 이용한 침입자 센서)

  • Eom, Yeon-Sik;Kim, Yo-Hui;Yang, Seung-Guk;O, Sang-Gi;Kim, In-Su;Park, Jae-Hui;Gang, Sin-Won
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.3
    • /
    • pp.236-241
    • /
    • 2001
  • The speckle pattern is formed by laser light from a multimode optical fiber. The speckle fluctuation is the result of interference among propagation modes when the optical fiber is subjected to a mechanical perturbation at any point along its length. The experiments were carried on for the study of the feasibility of producing an intrusion detection system using the speckle fluctuation. The speckle fluctuation signals were monitored at real time by an oscilloscope which was connected with a rectifier and a FVC. We used a jig as a PD holder to improve the sensitivity of speckle phenomena and simplify its structure. So we can know the time and magnitude of perturbation.

  • PDF

Deformation Characteristics of Flexible Pipe with Variation of Buried Conditions (매설조건에 따른 연성관의 변형특성)

  • Lee, Bongjik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.10
    • /
    • pp.53-62
    • /
    • 2014
  • In Korea, the pipe type that has been well used as sewage pipe from the past is primarily a rigid pipe which is represented by concrete hume pipe, but the use of it is being decreased sharply because of the problems such as tube erosion and incomplete watertightness securing through the time. On the other hand, the use of flexible pipe has been increased because its construction ability is excellent on account of its light weight as well as it is resistant to corrosion. However, because there are lacks of market's confidence in flexible pipe and occurrence cases of partial damage incomplete caused by compaction control, cause analysis and management for them are needed. Therefore, this study tried to estimate the deformation characteristics of pipe caused by each condition through numerical analysis changing construction sequence, rigidity of pipe, strength of ground concrete under the pipe, relative compaction ratio of sand foundation under the pipe and relative compaction ratio of backfill material above the pipe. Evaluation result is that influence on each factor is confirmed and the quality control of sand around the pipe are turned up to be important.

Study on the Analysis regarding the Connection Network of Design Inspirations pursued by Modern Fashion Designers - Focus on the Concept of Fashion Collections -

  • Kim, Young Sam;Kim, Jang Hyeon;Kim, Sung Soo
    • Fashion & Textile Research Journal
    • /
    • v.17 no.3
    • /
    • pp.351-363
    • /
    • 2015
  • This research explores diachronic fashion design trends through a structure analysis of a connection network based on fashion show concepts implemented by modern fashion designers from S/S 2009 to F/W 2013. The findings from this research are as follows. First, four categories affect the inspiration and thinking of design: the experience of the designer, social atmosphere and phenomena, natural sensitivity (or formative characteristics of natural objects), and the influence and quality of other fields. Second, in cases where the designers' experiences influenced design inspiration and thinking, designers express personal memories with keywords like high school, grandmother's closet, prom, beauty and the beast, heritage, past, and reminiscence through design elements such as lines, silhouettes, materials, and colors. Third, the representative example of the social atmosphere and phenomena that influenced design inspiration and thinking was the 2008 Global Financial Crisis that reflected the social climate through design concepts of keywords such as Recession, Black, Economy, US, Depression, Gray, Dark Age, White and New York. Fourth, inspired by nature and the formative characteristics in design, the designers employed ornamental elements to collections and design concepts that focused on nature words connected to light, sun, wild, dirt, rock, moss, and trees. Fifth, the designers took their ideas from different fields of personal interest in the arts, science and humanities (sports, architecture, sculpture, painting, and literature) that were decisive in determining materials, design colors and silhouettes. The theme of architecture was analyzed as a central element that had an ongoing impact on the concepts of designers.

The Ecophysiological Changes of Capsicum annuum on Ozone-Sensitive and Resistant Varieties Exposed to Short-Term Ozone Stress (오존 감수성 및 저항성 고추 품종의 생리생태 변화)

  • Yun, Sung-Chul
    • Korean Journal of Environmental Agriculture
    • /
    • v.23 no.3
    • /
    • pp.128-132
    • /
    • 2004
  • Ozone effects were studied by plant growth chamber to evaluate the impact of ozone ($O_3$) on the physiology of two hot pepper, Capsicum annuum L., cultivars, 'Dabotab' and 'Buchon'. Forty-day old plants with $5{\sim}7$ leaves were exposed to $O_3$ of <20 and 150 nL/L for 8h/d for 3 days. Net photosynthesis and stomatal conductance were measured and foliar injury was described. Foliar damage due to the treated $O_3$ was different from the varieties. 'Dabotab' was most sensitive to $O_3$ and 'Buchon' was resistant. Symptom of ozone damage on the leaves was bifacial necrosis. Decreases of net photosynthesis by $O_3$ were 56% and 40% on 'Dabotab' and 'Buchon', respectively. Decreases of stomatal conductance by $O_3$ were 66% and 63% on each variety. $O_3$ damage on net photosynthesis was started at the low levels of light on the two hot peppers. In addition, assimilation-internal $CO_2$ concentration curves were not different from the two varieties. In conclusion, $O_3$ closed the stomata and decrease net photosynthesis on hot peppers regardless of the ozone sensitivity on leaf injury, but the difference of ecophysiological responses between the two varieties was not found clearly.

Development of Radiation Sensor Based on Array SiPM for Measurement of Radioactive Contamination in Effluent (방류수의 방사능 오염 측정을 위한 배열형 SiPM 기반 방사선 검출 센서 제작)

  • Kim, Jeongho;Park, Hyemin;Joo, Koansik
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.4
    • /
    • pp.232-236
    • /
    • 2018
  • A radiation detection sensor was developed and characterized by combining three types of CsI(Tl) scintillators and an array-type SiPM to detect the radioactive contamination of discharged water in real time. The characterization results showed that type 3 exhibited the most desirable characteristics in response linearity (R-square: 0.97889) according to detection sensitivity and incident radiation dose. Furthermore, in terms of spectral characteristics, type 3 exhibited 16.54% at 0.356 MeV (the emission gamma ray energy of $^{133}Ba$), 10.28% at 0.511 MeV (the emission gamma ray energy of $^{22}Na$), 9.68% at 0.356 MeV (the emission gamma ray energy of $^{137}Cs$), and 2.55% and 4.80% at 1.173 MeV and 1.332 MeV (the emission gamma ray energies of $^{60}Co$), respectively. These measurements confirmed the good energy characteristics. The results were used to evaluate the spectral characteristics and energy linearity in a mixed source using type 3 with the best detection characteristics. It was confirmed that the gamma ray peaks of $^{133}Ba$, $^{22}Na$, $^{137}Cs$, and $^{60}Co$ were well resolved. Moreover, it was confirmed that R-square, which is an indicator of energy linearity, was 0.99986. This indicates a good linearity characteristic. Based on this study, further commercialization studies will contribute to measurements in real time and to the management of the contamination caused by radioactive wastewater or radioactive material leakage, which originate from facilities that use radioactive isotopes or care facilities.

5-Aminolevulinic Acid Fluorescence in Detection of Peritoneal Metastases

  • Yonemura, Yutaka;Canbay, Emel;Ishibashi, Haruaki;Nishino, Eisei;Endou, Yoshio;Sako, Shouzou;Ogura, Shun-Ichirou
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.4
    • /
    • pp.2271-2275
    • /
    • 2016
  • Background: The value of 5-aminolevulinic acid (ALA) in fluorescence detection of peritoneal metastases and the underlying mechanisms were evaluated in patients with peritoneal surface malignancies. Materials and Methods: Oral 5-ALA was administered at a concentration of 20 mg/kg body weight with 50 ml of water 2 hours prior to surgery (n=115). The diagnostic value of 5-ALA based fluorescence production was evaluated following white light inspection during prior to cytoreductive surgery and hyperthermic intraperitoneal chemotherapy. Then, peptide transporter PEPT1 (ALA influx transporter) and ATP-binding cassette transporter ABCG2 (porphyrin efflux transporter) gene expression was determined with quantitative real time (qRT)-PCR and pathological diagnoses confirmed for all tissue samples. Results: The 5-ALA based photodynamic detection rate was 17% for appendiceal mucinous neoplasms, 54% for colorectal cancers, 33% for gastric cancers, 67% for diffuse malign peritoneal mesotheliomas, and 89% for epithelial ovarian cancer of peritoneal metastases. 5-ALA was detected in all cases of peritoneal metastases originating from cholangiocarcinomas whereas it was not able to detect any in granulosa cell and gastrointestinal stromal tumor cases. Furthermore, PEPT1 was overexpressed whereas ABCG2 expression was downregulated in tumors detected with fluorescence. Conclusions: 5-ALA provided 100% specificity and high sensitivity to detect peritoneal metastases in subgroups of patients with peritoneal surface mailgnancies. ALA influx transporter PEPT1 and porphyrin efflux transporter ABCG2 genes are important in tumor specific 5-ALA induced fluorescence in vivo. Further studies should clarify diagnostic utility of 5-ALA in peritoneal surface malignancies.

Alu Hypomethylation in Smoke-Exposed Epithelia and Oral Squamous Carcinoma

  • Puttipanyalears, Charoenchai;Subbalekha, Keskanya;Mutirangura, Apiwat;Kitkumthorn, Nakarin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.9
    • /
    • pp.5495-5501
    • /
    • 2013
  • Background: Alu elements are one of the most common repetitive sequences that now constitute more than 10% of the human genome and potential targets for epigenetic alterations. Correspondingly, methylation of these elements can result in a genome-wide event that may have an impact in cancer. However, studies investigating the genome-wide status of Alu methylation in cancer remain limited. Objectives: Oral squamous cell carcinoma (OSCC) presents with high incidence in South-East Asia and thus the aim of this study was to evaluate the Alu methylation status in OSCCs and explore with the possibility of using this information for diagnostic screening. We evaluated Alu methylation status in a) normal oral mucosa compared to OSCC; b) peripheral blood mononuclear cells (PBMCs) of normal controls comparing to oral cancer patients; c) among oral epithelium of normal controls, smokers and oral cancer patients. Materials and Methods: Alu methylation was detected by combined bisulfite restriction analysis (COBRA) at 2 CpG sites. The amplified products were classified into three patterns; hypermethylation ($^mC^mC$), partial methylation ($^uC^mC+^mC^uC$), and hypomethylation ($^uC^uC$). Results: The results demonstrate that the $%^mC^mC$ value is suitable for differentiating normal and cancer in oral tissues (p=0.0002), but is not significantly observe in PBMCs. In addition, a stepwise decrease in this value was observed in the oral epithelium from normal, light smoker, heavy smoker, low stage and high stage OSCC (p=0.0003). Furthermore, receiver operating characteristic (ROC) curve analyses demonstrated the potential of combined $%^mC$ or $%^mC^mC$ values as markers for oral cancer detection with sensitivity and specificity of 86.7% and 56.7%, respectively. Conclusions: Alu hypomethylation is likely to be associated with multistep oral carcinogenesis, and might be developed as a screening tool for oral cancer detection.

Localized Surface Plasmon Resonance (LSPR) Biosensors on Metal Nanoparticles with the Design of Bioreceptors

  • Kim, Min-Gon;Park, Jin-Ho;Byun, Ju-Young;Shin, Yong-Beom
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.126-126
    • /
    • 2014
  • Label-free biomolecular assay based localized surface plasmon resonance (LSPR) of noble metal nanoparticles enables simple and rapid detection with the use of simple equipment. Nanosized metal nanoparticles exhibit a strong absorption band when the incident light frequency is resonant with the collective oscillation of the electrons, which is known as the LSPR. Here we demonstrate localized surface plasmon resonance (LSPR) substrates such as plasmonic Au nanodisks fabricated by a nanoimprinting process and gold nanorod-immobilized surfaces and their applications to highly sensitive and/or label-free biosensing. To increase detection sensitivity various bioreceptors weree designed. A single chain variable fragment (scFv) was used as a receptor to bind C-reactive protein (CRP). The results of this effort showed that CRP in human serum could be quantitatively detected lower than 1 ng/ml. Aptamers, which were immobilized on gold nanorods, were used to detect mycotoxins. The specific binding of ochratoxin A (OTA) to the aptamer was monitored by the longitudinal wavelength shift of LSPR peak in the UV-Vis spectra resulting from the changes of local refractive index near the GNR surface induced by accumulation of OTA and G-quadruplex structure formation of the aptamer. According to our results, OTA could be quantitatively detected lower than 1 nM level. Additionally, aptamer-functionalized GNR substrate was quite robust and can be regenerated many times by rinsing at 70 OC to remove bound target. During seven times of washing steps, the developed OTA sensing system could be reusable. Moreover, the proposed biosensor exhibited selectivity over other mycotoxins with an excellent recovery for detection in grinded corn samples, suggesting that the proposed LSPR based aptasensor plays an important role in label-free detection of mycotoxins.

  • PDF

High Strain Rate Tensile Test of Composite Material for Automotive Front End Module Carrier (자동차 프론트엔드모률 캐리어용 경량 복합소재의 고속인장 시험)

  • Kang, Woo-Jong;Kim, Sung-Tae
    • Composites Research
    • /
    • v.24 no.3
    • /
    • pp.12-16
    • /
    • 2011
  • High strain rate tensile tests were performed to measure the strain rate sensitivity of fiber reinforced composite material. The composite material was developed for the light weight design of an automotive FEM(front end module) carrier. Standard specimens for quasi-static tests of fiber reinforced composites can be found in ASTM D3039. However, in case of high strain rate tests, it was hard to find standard specimen shapes. In this study, three kinds of tensile specimens designed based on ASTM D638 were investigated to determined the adequate gauge width of tensile specimen for fiber reinforced composite. A drop tower type of high speed tensile apparatus was developed for strain rates of about 15/s and 100/s. Gauge width of 6mm, 8mm and 10mm were investigated. Test results showed the specimen of 8mm width was adequate for the high strain rate tensile tests of fiber reinforced composite. It was found the strength of the composite material increased as the strain rate increased.

A Biosensor for the Rapid Detection of the Fungicide Iprovalicarb Residuess (살균제 Iprovalicarb 잔류물의 신속한 검출을 위한 바이오센서)

  • Cho, Han-Keun;Kim, Woon-Ho;Kyung, Kee-Sung;Lee, Eun-Young
    • Journal of Biosystems Engineering
    • /
    • v.32 no.6
    • /
    • pp.440-447
    • /
    • 2007
  • In this study, a biosensor was developed using an enzyme-linked immunosorbent assay (ELISA) to rapidly measure the fungicide iprovalicarb residues in agricultural products. The biosensor was designed to include micro-pumps and solenoid valves for fluid transport, a spectrophotometer cuvet as a reaction chamber, a photodiode with a light-emitting diode for optical density measurement, and a control microcomputer to implement assay. The rate of change in optical density of the cuvet was read as final signal output. Micro-pumps were evaluated to investigate their delivery capability, the highest values of the error and the coefficient of variation were 4.3% and 4.6% respectively. As the incubation period was reduced from 15 minutes to 11 minutes to shorten the total processing time, the sensor sensitivity was decreased as the antibody dilution ratio was reduced to a half. The maximum usable period of the coated cuvet was found to be two days with 1% error limit. To predict the concentration of the iprovalicarb residue in agricultural products, a linear calibration model was obtained with r-square values of 0.992 for potato and 0.985 for onion. In validation test for the samples of potatoes and onions against the high performance liquid chromatography, very high correlation values were obtained as 0.996 and 0.993 respectively. Using the cuvet immobilized with antigen, it took 21-minutes for the biosensor to complete the measuring process of the iprovalicarb residues.