• Title/Summary/Keyword: Ligament Width

검색결과 49건 처리시간 0.022초

Youth throwing athletes do not show bilateral differences in medial elbow width or flexor tendon thickness

  • Morrow, Rudolph M.;McIlvian, Gary E.;Johnson, Jenifer;Timmons, Mark K.
    • Clinics in Shoulder and Elbow
    • /
    • 제25권3호
    • /
    • pp.188-194
    • /
    • 2022
  • Background: Medial elbow laxity develops in throwing athletes due to valgus forces. Medial elbow instability in professional, collegiate, and high school athletes is well documented; however, the medial elbow of young throwing athletes has received less attention. This study investigated the medial elbow and common flexor tendon during applied elbow valgus stress of youth baseball players. Methods: The study included 15 participants. The medial elbow width and thickness of the common flexor tendon were measured on ultrasound images. Results: No significant side differences in medial elbow width or common flexor tendon were found at rest or under applied valgus stress. At rest, the medial elbow joint width was 3.34±0.94 mm on the dominant side and 3.42±0.86 mm on the non-dominant side. The dominant side increased to 3.83±1.02 mm with applied valgus stress, and the non-dominant side increased to 3.96±1.04 mm. The mean flexor tendon thickness was 3.89±0.63 mm on the dominant side and 4.02±0.70 mm on the non-dominant side. Conclusions: These findings differ from similar studies in older throwing athletes, likely because of the lack of accumulated stress on the medial elbow of youth throwing athletes. Maintaining elbow stability in young throwing athletes is a vital step to preventing injury later in their careers.

용접부 중앙에 균열이 존재하는 인장 평판에 대한 한계하중 해석 (Limit load analyses of weld-center cracked plates under tension)

  • 송태광;김윤재;김종성;진태은
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1830-1835
    • /
    • 2007
  • In the present work, the effect of strength mismatch on plastic limit loads is quantified for strength-mismatched plates with constant-depth surface cracks under tension, via three-dimensional, small strain elastic-perfectly plastic finite element analyses. Relevant variables related to plate and crack geometries are systematically varied, in addition to the weld width. An important finding is that a parameter related to the weld width-to-ligament ratio is proposed, based on which limit loads can be uniquely quantified. The proposed limit load solutions is a valuable input to estimate nonlinear fracture mechanics parameters based on the reference stress approach.

  • PDF

인장-전단하중을 받는 일점 Spot용접재의 파괴역학적 피로강도 평가 (Fracture mechanical evaluation of fatigue strength of a single spot welded lap joint under tension-shear load)

  • 배동호
    • 오토저널
    • /
    • 제13권5호
    • /
    • pp.42-50
    • /
    • 1991
  • According as the members and inner and outer plates of the automobile body structure have been thinned their thickness and have become high strength, each part of the body structure has been put more severe stress condition. Therefore, it has been increasingly required to improve the fatigue strength of the spot welded structures. As one of the improving methods for such problem, the author had previously proposed the method of alleviating stress concentration at nugget edge of the spot weld part and improving its fatigue strength [1]. But, because fatigue strength of the spot welded lap joint is influenced by its geometrical and mechanical factors, welding condition and etc., there needs a quantitative and systematic estimation method of them. In this report, by considering nugget edge of the spot weld part of the spot welded lap joint subjected to tensile load to the ligament crack, fatigue strength of various spot welded lap joints was estimated with the stress intensity factor (S.I.F.) K which is fracture mechanical parameter. It is known that evaluation of fatigue strength of the spot welded lap joint by the stress intensity factor (S.I.F.) K is more effective than the maximum stress $(\sigma_{ymax}$) at edge of the spot weld part on the center line of width of the plate.

  • PDF

성견에서 Acelluar dermal matrix가 1면 골내낭 결손부의 치주조직 재생에 미치는 영향 (The effects of Acellular dermal matrix on the healing of 1 wall intrabony defects in dogs)

  • 박주언;김병옥;박주철;장현선
    • Journal of Periodontal and Implant Science
    • /
    • 제36권1호
    • /
    • pp.27-37
    • /
    • 2006
  • Although the main purpose of periodontal treatment to regenerate is the complete regeneration of periodontal tissue due to periodontal disease, most of the treatment cannot meet such purpose because healing by long epithelial junction. Therefore, diverse materials of resorbable and non-resorbable have been used to regenerate the periodontal tissue. Due to high risk of exposure and necessity of secondary surgical procedure when using non-resorbable membrane, guided tissue regeneration using the resorbable membrane has gain popularity, recently. However, present resorbable membrane has the disadvantage of not having sufficient time to regenerate date to the difference of resorption rate according to surgical site. Meanwhile, other than the structure stability and facile manipulation, acellular dermal matrix has been reported to be a possible scaffold for cellular proliferation due to rapid revascularization and favorable physical properties for cellular attachment and proliferation. The purpose of this study is to estimate the influence of acellular dermal matrix on periodontal ligament, cementum and alveolar bone when acellular dermal matrix is implanted to 1-wall alveolar bone defect. 4 dogs of 12 to 16 month old irrelevant to sex , which below 15Kg of body weight, has been used in this study. ADM has been used for the material of guided tissue regeneration. The 3rd premolar of the lower jaw was extracted bilaterally and awaited for self-healing. subsequently buccal and lingual flap was elevated to form one wall intrabony defect with the depth and width of 4mm on the distal surface of 2nd premolar and the mesial surface of 4th premolar. After the removal of periodontal ligament by root planing. notch was formed on the basal position. Following the root surface treatment, while the control group had the flap sutured without any treatment on surgically induced intrabony defect. Following the root surface treatment, the flap of intrabony defect was sutured with the ADM inserted while the control group sutured without any insertion. The histologic specimen was observed after 4 and 8 weeks of treatment. The control group was partially regenerated by periodontal ligament, new cementum and new alveolar bone. the level of regeneration is not reached on the previous formed notch. but, experimental group was fully regenerated by functionally oriented periodontal ligament fiber. new cementum and new alveolar bone. In conclusion, we think that ADM seems to be used by scaffold for periodontal ligament cells and the matrix is expected to use on guided tissue regeneration.

A coupled damage-viscoplasticity model for the analysis of localisation and size effects

  • Georgin, J.F.;Sluys, L.J.;Reynouard, J.M.
    • Computers and Concrete
    • /
    • 제1권2호
    • /
    • pp.169-188
    • /
    • 2004
  • A coupled damage-viscoplasticity model is presented for the analysis of localisation and size effects. On one hand, viscosity helps to avoid mesh sensitivity because of the introduction of a length scale in the model and, on the other hand, enables to represent size effects. Size effects were analysed by means of three-point bending tests. Correlation between the fracture energy parameter measured experimentally and the density fracture energy modelling parameter is discussed. It has been shown that the dependence of nominal strength and fracture energy on size is determined by the ligament length in comparison with the width of the fracture process zone.

A Scanning Electron Microscopic Study on the Glochidial Encystment of a Freshwater Clam Anodonta archeformis on the Host Fish Carassius auratus

  • Jeong, Kye-Heon;Lee, Yong-Seok
    • 한국어업기술학회:학술대회논문집
    • /
    • 한국어업기술학회 2001년도 춘계 수산관련학회 공동학술대회발표요지집
    • /
    • pp.595-596
    • /
    • 2001
  • A scanning electron microscopic study on the glochidium and glochidial encystment of Anodonta archefomis on the host fish Carassius auratus was conducted. The shape of the glochidium is apparently subtriangular and its average size is 270${\mu}{\textrm}{m}$ $\times$ 260${\mu}{\textrm}{m}$ $\times$ 145${\mu}{\textrm}{m}$. The glochidial shell valves are of the same size, kept together by a ligament of 50.4${\mu}{\textrm}{m}$ in length and 5.5${\mu}{\textrm}{m}$ in width. (omitted)

  • PDF

초음파 Fractography에 의한 파괴속도의 첨밀측정을 위한 최적주파수 선정에 관한 연구 (A Study on the Optimal Frequency for Precise Measurement of Fracture Velocity by Ultrasonic Fractography)

  • 이범성;한응교;송창섭
    • 한국정밀공학회지
    • /
    • 제10권2호
    • /
    • pp.154-160
    • /
    • 1993
  • A mothod to decide the optimal frequency for the fracture velocity measurement by ultrasonic fractography is presented. A theoretical formula to decide the optimal frequency for ultrasonic fractography testing is made and it is compared with experimental value. According to the formula the optimal frequency is shown to be depending on the attenuation coefficient and size(width) of the specimen. In the case of PMA specimen with ligament 43mm the theoretical value for the optimal frequency is about 260 KHz and it is good agreement with experimental value.

  • PDF

발치와의 결손부위에 $Regenafil^{TM}$의 임상적 적용에 관한 조직학적 연구 (Histologic evaluation of $Regenafil^{TM}$ on defects of extraction socket)

  • 계승범;양승민;설양조;이영규
    • Journal of Periodontal and Implant Science
    • /
    • 제33권3호
    • /
    • pp.533-542
    • /
    • 2003
  • The purpose of this study is to evaluate histologic result of bone substituting material on defects followed tooth extraction. We compare the histologic findings control, DFDBA, Bio-Oss(R), and $Regenafil^{TM}$, Briefly, mandibular premolar teeth were extracted available for bone filling. All alveolar sites were checked after extraction and thoroughly debrided with a dental curet to remove the periodontal ligament. Extraction sites were prepared dehiscence on buccal side 7mm height from alveolar crest. The graft materials were filled into the extraction socket and dehiscenc defects. The animals were sacrificed 12 weeks after implantation. Both treated and control mandibular sites were histologically evaluated with light microscopy. Histologic observation at 12 weeks revealed that control and experimental sites were healed uneventfully and directly apposed to new bone without any adverse tissue reaction. DFDBA and Bio-Ossn(R)sites maintain width of alveolar crest but were not fully resorbed. $Regenafil^{TM}$ sites also maintain width and particles were resorbed more than other graft materials. From this results, it was suggested that $Regenafil^{TM}$ is promising boen substituting materials maintaining the width of alveolar crest and height follewed tooth extraction.

아말감 와동의 파절에 관한 2차원 유한요소법적 연구 I : 와동 폭의 변화 (A STUDY ON AMALGAM CAVITY FRACTURE WITH TWO DIMENSIONAL FINITE ELEMENT METHOD I : VARIATION OF THE WIDTH OF CAVITY)

  • 김한욱;이정식
    • Restorative Dentistry and Endodontics
    • /
    • 제20권2호
    • /
    • pp.655-669
    • /
    • 1995
  • Restorative procedures can lead to weakening tooth due to reduction and alteration of tooth structure. It is essential to prevent fractures to conserve tooth. Among the several parameters in cavity designs, cavity isthmus is very important. In this study, amalgam 0 cavity was prepared on maxillary first premolar. Two dimensional finite element models were made by serial photographic method and isthmus(1/4, 1/3, 1/2, 2/3 of intercuspal distance) were varied. Three or four-nodal mesh were used for the two dimensional finite element models. The periodontal ligament and alveolar bone surrounding the tooth were excluded in these models. 1S model was sound tooth with no amalgam cavity. B model was assumed perfect bonding between the restoration and cavity wall. Both compressive and tensile forces were distributed directly to the adjacent regions. A load of 500N was applied vertically at the first node from the lingual slope of the buccal cusp tip. This study analysed von Mises stress, 1 and 2 directional normal stress and Y and Z axis translation with FEM software Super SAPII Version 5.2 (Algor Interactive System Co.) and hardware 486 DX2 PC. The results were as :follows : 1. 1S model was slightly different with 1B model in stress distibution. 1S, 2B, 3B, 4B models showed similiar stress distribution. 2. 1S model and four B models showed similiar pattern in Y axis and Z axis translation. 3. 1S model and four B models showed the bending phenomenon in the translation. 4. As increasing of the width of the cavity, experimental group was similiar with the control group in stress distribution. 5. As increasing of the width of the cavity, experimental group was similiar with the control group in Y and Z axis tranlation.

  • PDF

Clinically Correlated Anatomical Basis of Cricothyrotomy and Tracheostomy

  • Gulsen, Salih;Unal, Melih;Dinc, Ahmet Hakan;Altinors, Nur
    • Journal of Korean Neurosurgical Society
    • /
    • 제47권3호
    • /
    • pp.174-179
    • /
    • 2010
  • Objective : Cricothyrotomy and tracheostomy are performed by physicians in various disciplines. It is important to know the comprehensive anatomy of the laryngotracheal region. Hemorrhage, esophageal injury, recurrent laryngeal nerve injury, pneumothorax, hemothorax, false passage of the tube and tracheal stenosis after decannulation are well known complications of the cricothyrotomy and tracheostomy. Cricothyrotomy and tracheostomy should be performed without complications and as quickly as possible with regards the patients' clinical condition. Methods : A total of 40 cadaver necks were dissected in this study. The trachea and larynx and the relationship between the trachea and larynx and the surrounding structures was investigated. The tracheal cartilages and annular ligaments were counted and the relationship between tracheal cartilages and the thyroid gland and vascular structures was investigated. We performed cricothyrotomy and tracheostomy in eleven cadavers while simulating intensive care unit conditions to determine the duration of those procedures. Results : There were 11 tracheal cartilages and 10 annular ligaments between the cricoid cartilage and sternal notch. The average length of trachea between the cricoid cartilage and the suprasternal notch was 6.9 to 8.2 cm. The cricothyroid muscle and cricothyroid ligament were observed and dissected and no vital anatomic structure detected. The average length and width of the cricothyroid ligament was 8 to 12 mm and 8 to 10 mm, respectively. There was a statistically significant difference between the surgical time required for cricothyrotomy and tracheostomy (p < 0.0001). Conclusion : Tracheostomy and cricothyrotomy have a low complication rate if the person performing the procedure has thorough knowledge of the neck anatomy. The choice of tracheostomy or cricothyrotomy to establish an airway depends on the patients' clinical condition, for instance; cricothyrotomy should be preferred in patients with cervicothoracal injury or dislocation who suffer from respiratory dysfunction. Furthermore; if a patient is under risk of hypoxia or anoxia due to a difficult airway, cricothyrotomy should be preferred rather than tracheostomy.