• Title/Summary/Keyword: Ligament Width

Search Result 50, Processing Time 0.024 seconds

Morphometry of the patellar tendon using a simple tracing method: a gold standard for anterior cruciate ligament reconstruction

  • Sabiha Latiff;Oladiran Ibukunolu Olateju
    • Anatomy and Cell Biology
    • /
    • v.56 no.2
    • /
    • pp.191-199
    • /
    • 2023
  • The anterior cruciate ligament (ACL) is mostly damaged in sporting activities. To reconstruct the damaged ACL, a patellar tendon (PT) is often the most preferred graft due to its fast healing and bone integration i.e. bone-patellar tendon-bone graft. Suitability of the PT often depends on the morphometric profile of the tendon. This study reported on the harvestable surface area (SA) of the tendon using a simple tracing method. The PT of 79 adult formalin-fixed cadavers of South Africans of European Ancestry were dissected, and the margins of the PT were traced on a wax paper before the tracings were scanned. The SA, straight proximal width (SPW), curved proximal width (CPW), straight distal width (SDW), curved distal width (CDW) and length of tendon (LOT) from the digitized image of the PT was measured. In addition, the length of the lower limbs was measured to normalize the measurements. The results showed no significant side differences, and the measurements were not sexually dimorphic. A strong correlation was reported for SA vs. LOT, SPW vs. CPW and SDW vs. CDW for both sexes and sides. The presented morphological profile provides additional information on the usability of the graft and with respect to healing and recovery.

측두하악절인대의 해부학적 관찰

  • Chung, Keun-Yong;Choi, Dan;Lim, Jung-Kyun;Kim, Hyo-Cheol;Park, Chang-Hee;Kim, Myung-Kook;Koo, Chang-Soo
    • The Journal of the Korean dental association
    • /
    • v.12 no.3
    • /
    • pp.163-165
    • /
    • 1974
  • The shape and size of the various regions of the temporomandibular ligament were examined in 30 Korean cadavers, which were used for dissection in Seoul Dental College from 1970 to 1973. The results were as follows; 1. The shape of the temporomandibular ligament were as follows; a. Type I : fan shape (8mm in width between origin and insertion) - 20.2% b. Type II : fan shape (10mm in width between origin and insertion) - 70.0% c. Type III : fan shape (12mm in width between origin and insertion) - 10.0% 2. The length of the various regions of the temporomandibular ligament were as follows ; a. Length in origin - 13.4mm b. Length in insertion - 6.0mm c. Length in anterior margin - 25.8mm d. Length in posterior margin - 19.3mm

  • PDF

RADIOLOGIC VARIABLES AFFECTING EXTRACTION OF I MPATCTED MANDIBULAR THIRD MOLARS (매복 하악 제3대구치의 외과적 발거에 영향을 미치는 방사선학적 변수)

  • Kim, Dong-Hyun;Park, Sung-Bin;Chang, Ic-Jun;Song, Jae-Chul;Chin, Byung-Rho
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.23 no.3
    • /
    • pp.238-243
    • /
    • 2001
  • Purpose : The purpose of this study was to determine radiologic variables affecting extraction of impacted mandibular third molar. Materials and Methods : This study was investigated on 44 consecutive extractions of unilateral impacted mandibular third molars (Male;34, Female;10, Mean age;24.98, Age range;19-35). Fourteen radiologic variables, which were actual value except only one, were evaluated to establish their relation to the operation time. The Pearson correlation coefficient and Stepwise procedures for regression analysis were carried out. Results : Eight variables (depth, angulation, ramus width, relationship to the second molar, distal ramus depth, mesial ramus depth, mesial periodontal ligament width and follicle) showed a statistically significant relation to the operation time(Pearson correlation coefficient, p<0.05). Two variables, depth and mesial periodontal ligament width, showed the most powerful and just relation to the operation time($r^2$ = 0.349, p<0.05). Conclusion : This study shows that our results can help general practioner to estimate the operation time of extraction of impacted mandibular third molars by measuring two radiologic variables ; depth and mesial periondontal ligament width.

  • PDF

A Morphometric Study of the Lumbar Interspinous Space in 100 Stanford University Medical Center Patients

  • Jang, Donghwan;Park, Seoungwoo
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.5
    • /
    • pp.261-266
    • /
    • 2014
  • Objective : With the increased use of interspinous spacers in the treatment of lumbar stenosis, knowledge of the geometry of the interspinous space is important. To prevent dislodgment of an interspinous spacer, the accurate depth and width of the interspinous space needs to be established to facilitate the best intraoperative selection of correct spacer size. Methods : To determine the depth and width of the interspinous space, two methods are available which utilize plain film and magnetic resonance imaging (MRI). Data analysis of the interspinous depth and width was undertaken in 100 patients. Results : The standard deviations were variable, since skin thickness (zone 1) was altered by sex and age. The difference in the zone 1 distance between adjacent interspinous processes varied according to gender (p<0.05), but was not influenced by age [p=0.32 by analysis of variance between groups (ANOVA)]. Zone 2, the supraspinous, and zone 3, the interspinous ligament depths, comprise the operative working area during insertion of an interspinous spacer. There were no differences with regard to gender or age (p>0.05). For zones 6 and 7, the interspinous distances at the narrowest and widest points, respectively, were found to decrease with the aging process, but the decrease was not statistically significant. There were no differences with regard to gender (p>0.05). Conclusion : This study provides additional information on the interspinous space. This statistical data are valuable for use in the design of interspinous spacers.

Morphometric Study of the Lumbar Posterior Longitudinal Ligament

  • Lee, Sang Beom;Chang, Jae Chil;Lee, Gwang Soo;Hwang, Jae Chan;Bae, Hack Gun;Doh, Jae Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.1
    • /
    • pp.89-96
    • /
    • 2018
  • Objective : Morphometric data for the lumbar posterior longitudinal ligament (PLL) was investigated to identify whether there is a difference in the morphometry of the PLL of the lumbar spine at each level with respect to the pattern of intervertebral disc displacement. Methods : In 14 formalin-fixed adult cadavers (12 males and 2 females), from L1 to L5, the authors measured the width and height of the PLL and compared them with other landmarks such as the disc and the pedicle. Results : Horizontally, at the upper margin of the disc, the central portion of the superficial PLL covered 17.8-36.9% of the disc width and the fan-like portion of the PLL covered 63.9-76.7% of the disc width. At the level of the median portion of the disc, the PLL covered 69.1-74.5% of the disc width. Vertically, at the level of the medial margin of the pedicle, the fan-like portion of the PLL covered 23.5-29.9% of the disc height. In general, a significant difference in length was not found in the right-left and male-female comparisons. Conclusion : This study presents the morphometric data on the pattern of intervertebral disc displacement and helps to improve the knowledge of the surgical anatomy of the lumbar PLL.

A HISTOLOGIC STUDY OF INITIAL CHANCE AND REPAIR OF TOOTH AND PERIODONTAL TISSUE IN EXTRUSION OF YOUNG ADULT DOGS (유성견 소구치 정출시 치아 및 치주 조직의 초기 조직학적 변화 및 재생에 관한 연구)

  • Yoon, Byung-sun;Cha, Kyung-Suk;Lee, Jin-Woo
    • The korean journal of orthodontics
    • /
    • v.28 no.3 s.68
    • /
    • pp.419-429
    • /
    • 1998
  • This study was carried out in order to study early histologic changes and repair reaction appling to extrusive force for 3rd premolar of adult dogs. After 1 week of extrusive force with elastic chain, one of dogs was sacrified and after 3 weeks retention period, another dog was sacrified. The paraffin sections of samples were stained with Hematoxylin - Eosin and Masson's Trichrome and were examed by light microscopy . The obtained results as follows 1. In Hematoxylin - Eosin and Masson Trichrome stain of control group , the periodontal ligament width was constant from apical third to cervical third of the root and periodontal fiber arrangement was horizontal or oblique in cervical third. oblique in middle third, oblique in apical third of root. in alveolar bone, smooth appearance was shown 2. In Group 1, all periodontal fiber arrangement was oblique toward tooth, and the periodontal ligament width increased Partially PDL was ruptured in apex. In MT stain, immature bone formation was seen at alveolar crest area. Active bone formation was observed along the one side of alveolus, and apical portion of pulp was involved with blood vessel rupture , vacuolization of pulp tissue and hyperemia 3. In Group 2, most periodontal ligament arrangement and PDL width was repaired and fiber density increased. In MT stain, mineralization of immature bone on the alveolar crest was progressed. In pulp, vacuole and hyperemia was diminished and fibrotic change was diminished 4. After 3 week periodontal ligament has more repair ability than pulp tissue. pulp was involved with vacuolization and fibrosis, so it takes more time for repair.

  • PDF

The Comparison of Sonographic Features of Ankle Ligament and Tendon in Affected Side With Non-Affected Side Ambulatory of Hemiplegic Patients (보행 가능한 편마비 환자에서 편측 및 건측 하지 발목 관절의 인대와 힘줄의 초음파 비교)

  • Park, Ji-Woong;An, Jae-Ki;Park, Yong-Bum;Bae, Won-Sik
    • Physical Therapy Korea
    • /
    • v.17 no.2
    • /
    • pp.60-66
    • /
    • 2010
  • In chronic ambulatory hemiplegic patients, structural changes might be developed at both ankles possibly due to unequal and repetitive weight bearing on tendons and ligaments. We examined ankles by sonography to find out structural changes of tendons and ligaments of both ankles in ambulatory hemiplegic patients. Nineteen ambulatory hemiplegic patients over 1 year were included as study subjects. All subjects had no previous trauma or disease history in their ankle joints and they were able to walk independently or with supervision but had spastic ankles with equinovarus tendency. We examined both ankle joints by sonography to see joint effusion and measure width, thickness, and area of tendons of the tibialis anterior, tibialis posterior, and Achilles, and also ligaments of the anterior talofibular and calcaneofibular. We compared sonographic features of the hemi-side ankle with the sound-side ankle. There were no significant differences between hemi-side and sound-side ankles in almost all measured parameters of tendons and ligaments. However, the width of the hemi-side tibialis posterior tendon ($7.24{\pm}1.52$ mm) was narrower than the sound-side tendon ($8.61{\pm}1.37$ mm). With the amount of active joint motion and weight bearing possibly preventing ligament and tendon atrophy even though marked weakness, spasticity occurred during the chronic hemiplegic phase.

Effects of Mechanical Stimuli on the Cell Proliferation and Collagen Production on the Micropatterned Substrate

  • Park Su-A;Kim In-Ae;Kim Chong-Rak;Shin Ji-Won;Heo Su-Jin;Hwang Young-Mi;Kim Dong-Hwa;Shin Jung-Woog
    • Biomedical Science Letters
    • /
    • v.12 no.2
    • /
    • pp.119-125
    • /
    • 2006
  • In relation to the tissue engineering, the cellular responses to the morphology of the scaffold surface are interesting topics. Human ligament fibroblasts (HLFs) were cultured on the micrpatterned silicone substrates subjected to cyclic stretch to simulate ligament motion. Groove and ridge width of silicone substrates was 10/50, 20/50, 20/10, and 20/20 ${\mu}m$ (groove/ridge ${\mu}m$) with a depth of $3{\mu}m$. Strain was applied over two days for 4 hours per day with a frequency of 0.5 Hz with the magnitudes of 4 or 8%. The purpose of this study was to evaluate ligament fibroblast alignment and cellular responses in relation to the pattern of microgrooved surface and stretching magnitude. Ligament fibroblasts in the microgrooved surface were elongated and aligned parallel to the microgrooves under no stretch. Uniaxial cyclic stretch induced cellular activities and their orientation rise in cellular response and the cells showed alignment and elongation perpendicular to the direction of the stretch. Biochemical analyses showed that the best cellular response was found on the $20/50{\mu}m$ under 8% stretch. The surface morphology and mechanical stretching were found to contribute to increase of proliferation, collagen production.

  • PDF

Inter- and Intra-Observer Variability of the Volume of Cervical Ossification of the Posterior Longitudinal Ligament Using Medical Image Processing Software

  • Shin, Dong Ah;Ji, Gyu Yeul;Oh, Chang Hyun;Kim, Keung Nyun;Yoon, Do Heum;Shin, Hyunchul
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.4
    • /
    • pp.441-447
    • /
    • 2017
  • Objective : Computed tomography (CT)-based method of three dimensional (3D) analysis ($MIMICS^{(R)}$, Materialise, Leuven, Belgium) is reported as very useful software for evaluation of OPLL, but its reliability and reproducibility are obscure. This study was conducted to evaluate the accuracy of $MIMICS^{(R)}$ system, and inter- and intra-observer reliability in the measurement of OPLL. Methods : Three neurosurgeons independently analyzed the randomly selected 10 OPLL cases with medical image processing software ($MIMICS^{(R)}$) which create 3D model with Digital Imaging and Communication in Medicine (DICOM) data from CT images after brief explanation was given to examiners before the image construction steps. To assess the reliability of inter- and intra-examiner intraclass correlation coefficient (ICC), 3 examiners measured 4 parameters (volume, length, width, and length) in 10 cases 2 times with 1-week interval. Results : The inter-examiner ICCs among 3 examiners were 0.996 (95% confidence interval [CI], 0.987-0.999) for volume measurement, 0.973 (95% CI, 0.907-0.978) for thickness, 0.969 (95% CI, 0.895-0.993) for width, and 0.995 (95% CI, 0.983-0.999) for length. The intra-examiner ICCs were 0.994 (range, 0.991-0.996) for volume, 0.996 (range, 0.944-0.998) for length, 0.930 (range, 0.873-0.947) for width, and 0.987 (range, 0.985-0.995) for length. Conclusion : The medical image processing software ($MIMICS^{(R)}$) provided detailed quantification OPLL volume with minimal error of inter- and intra-observer reliability in the measurement of OPLL.