• Title/Summary/Keyword: Ligament Reconstruction

Search Result 354, Processing Time 0.037 seconds

Comparison of Clinical Outcomes in ACL Reconstruction using auto-Hamstring Tendon and allo-Tibialis Anterior Tendon (자가슬괵건 및 동종전경골건을 이용한 전방십자인대 재건술 후 임상적 결과의 비교)

  • Kim, Jae-Hwa;Lee, Yoon-Seok;Rhee, Seung-Yong;Chung, Ju-Hwan
    • Journal of the Korean Arthroscopy Society
    • /
    • v.11 no.2
    • /
    • pp.104-110
    • /
    • 2007
  • Purpose: The purpose of this study is comparison of clinical outcomes in ACL reconstruction between auto-hamstring tendon and allo-tibialis anterior tendon. Materials and Methods: In this prospective study, we included 60 subjects who underwent ACL reconstruction using 30 hamstring autograft(mainly, national health insurance) and 30 tibialis anterior allograft(including MVA and industrial injuries) between May 2003 and June 2005 by a single surgeon, with a minimum follow-up of 12 months. Outcome measurements were the range of motion, the Lachman test, the IKDC score, the Lysholm score, KT-1000 arthrometer and one-leg hop test. Results: For all the cases, the range of motion was above 135 degrees. The Lachman test, KT-1000 arthrometer and one-leg hop test showed no significant difference between two groups. The IKDC score of auto-hamstring group($87.840{\pm}2.106$) was significantly higher than that of allo-tibialis anterior group($85.273{\pm}2.782$). The Lysholm score of auto-hamstring group($88.067{\pm}2.586$) was also significantly higher than that of allo-tibialis anterior group($85.300{\pm}3.030$). Conclusion: The results of ACL reconstruction using the auto-hamstring tendon and allo-tibialis anterior tendon showed no significant difference in objective items but auto-hamstring group showed better results in subjective scoring. This difference may result from individual factors such as economic problem, secondary gain.

  • PDF

Relationship between Graft Appearance on Follow-up MRI and Knee Stability after Double Bundle ACL Reconstruction (이중 다발 전방십자 재건술 후 이식건의 자기공명영상 추시와 슬관절 안정성과의 관계)

  • Sim, Jae Ang;Kwak, Ji Hoon;Lee, Yong Seuk;Kim, Kwang Hui;Nam, Shin Woo;Jun, Sung Soo;Lee, Beom Koo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.16 no.2
    • /
    • pp.128-133
    • /
    • 2012
  • Purpose: This study examined the relationship between graft appearance on follow-up magnetic resonance imaging (MRI) and knee stability after double bundle anterior cruciate ligament (ACL) reconstruction. Materials and Methods: For each patient, 1.5 tesla MRI's were obtained. The signal intensity of grafts was divided into 3 grades by Sononda's classification. The course of grafts was divided into two patterns: straight and curved. We assessed Lachman test, KT 2000 arthrometer and anterior drawer stress radiograph using Telos$^{(R)}$ in $30^{\circ}$ knee flexion for anterior stability and evaluated pivot shift test for rotatory stability. The correlation between graft appearance on MRI and the results of knee stability tests was evaluated. Results: The anteromedial (AM) graft was evaluated as being grade 1 in 66.7%, grade 2 in 26.7%, and grade 3 in 6.7% of the cases and the posterolateal (PL) graft was assessed as being grade 1 in 63.3%, grade 2 in 33.3%, and grade 3 in 3.3% of the cases according to the signal intensity. The AM graft was evaluated as being straight in 83.3% and curved in 16.7% of the cases, and the PL graft was assessed as being straight in 86.7% and curved in 13.3% of the cases according to the course. The course of AM graft was correlated with the results of anterior stability tests and the course of PL graft was correlated with the result of rotatory stability test. However, the signal intensity of grafts was not correlated with the results of anterior stability and rotatory stability tests. Conclusion: The course of AM is correlated with anterior stability and the course of PL is correlated with rotatory stability on follow-up MRI after double bundle ACL reconstruction.

  • PDF

The Clinical Results of ACL Reconstruction with Tibialis Allograft Using Hybrid Femoral Fixation and $Retroscrew^{(R)}$ (Hybrid 대퇴 고정과 $Retroscrew^{(R)}$를 사용한 동종 경골건 이용 전방 십자 인대 재건술의 임상적 결과)

  • Kim, Doo-Sub;Rah, Jung-Ho
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.1
    • /
    • pp.8-13
    • /
    • 2009
  • Purpose: We used tibialis allograft for the reconstruction of ACL and used Hybrid femoral fixation utilizing $Endobutton^{(R)}$ and $Rigidfix^{(R)}$ for femoral fixation, and used $Retroscrew^{(R)}$ and additional fixation for tibial fixation to evaluate the clinical results. Materials and Methods: The ACL reconstruction were performed from February 2004 to February 2007 utilizing Hybrid femoral fixation and $Retroscrew^{(R)}$ and 32 patients, 32 cases which were available for year-long observation (12 to 25 months). The clinical results (Lysholm knee score, IKDC grade) and the radiologic results(bone tunnel expansion, Telos anterior displacement test) were evaluated. Results: The Lysholm knee score was improved from the average of $67.9{\pm}5.4$ points (range: 51~77) before operation and to $94.1{\pm}6.8$ points (range: 68~98) at the last follow up (p<0.05). 22 cases (69%) were evaluated normal (A), 9 cases (28%) were evaluated nearly normal (B) and only 1 case (3%) was evaluated not normal (C) at IKDC final evaluation and no case was evaluated abnormal. From $Telos^{(R)}$ stress x-ray evaluation, difference from the opposite knee was improved average 13.2 mm{\pm}5.8 (range: 6~21 mm) to average $3.4\;mm{\pm}2.8$ (range: 0~11 mm) after operation (p<0.05). The femoral and tibial tunnel were widened by 18.7% and 9.6% in the AP view and 12.4% and 8.5% in the lateral view, respectively (p<0.05). However, any statistic significance was not observed between bone tunnel expansion and knee joint functions (p>0.05). Conclusion: An ACL reconstruction with tibialis allograft using Hybrid femoral fixation and $Retroscrew^{(R)}$ enabled anatomical fixation of the graft tendon with satisfactory clinical results.

  • PDF

Arthroscopic ACL Reconstruction Using Fresh-Frozen Achilles Allograft -Clinical results, Recovery of sports activity- (아킬레스 동종건을 이용한 전방십자인대 재건술후 임상적 결과와 운동력 회복 평가)

  • Chun Churl Hong;Ha Dae Ho;Kim Dong Chul;Kim Hyun Jun
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.1 no.1
    • /
    • pp.31-36
    • /
    • 2002
  • Purpose : ACL (anterior cruciate ligament) reconstruction using achilles allograft was done for whom ACL injured person in recreational sports activity. The purpose of this study was to evaluate the clinical results and return to their sports activity in these patients. Materials and Methods : ACL injured 56 amateur athletes who had experienced sports 3 times a week more than 5 years, reconstructed with Achilles allograft, and it was analyzed subjective and objective parameter, Tegner scoring, Telos stress arthrometer, Lysholm Knee Scoring System and modified Feagin scoring system. The average age was 25 years old (range: 18$\~$49), the average follow up period was 15 months (range: 12$\~$19). Morbid sports were football (29 cases), basket ball (14 cases), badminton (5 cases), tennis (3 cases), squash (2 cases) and otherwise (3 cases). Result : The mean Lysholm Knee Scoring System was improved to 88.2 from 60. Telos arthrometer in anterior stress test revealed 2.3 mm improved from 7.1 mm. The modified Feagin scoring system showed 50 cases (89$\%$) with excellent and good results. We had obtained 12 cases (21$\%$) of Tegner score VI, 32 cases (57$\%$) of score V, 20 cases (35%$\%$ of score IV, 3 (5.3$\%$) cases of score III. Conclusions : Reconstruction of anterior cruciate ligaments can restore stability sufficient to allow sports activity in ACL injured patients, but it’s difficult to achieve 'normal' sports activity. So we will have to solve the reasons of this dissatisfaction at furthermore.

  • PDF

Arthroscoic Anterior Cruciate Ligament Reconstruction with Autogenous Hamstring Gratt - Effect of the Additional Fixation after Fixation of the Graft with Intrafix - (자가 슬괵건을 이용한 관절경적 전방 십자 인대 재건술 - INTRAFIX system을 이용한 경골부 고정 후 부가적 고정의 효과 -)

  • Yoo, Jae-Doo;Roh, Kwon-Jae;Shin, Sang-Jin;Yoon, Jong-Suk;Yeo, Sung-Gu
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.1
    • /
    • pp.51-55
    • /
    • 2005
  • Purpose: To compare the stability and clinical result after anterior cruciate ligament reconstructed knee after graft fixation using Intrafix in tibial tunnel with or without additional tibial post fixation. Materials and Methods: We analyzed 37 cases which were treated with four-strand hamstring tendon autograft during the period from May 2002 to January 2003. The grafts were fixed with Rigidfix system (Mitek Product, Johnson and Johnson, USA) in femur tunnel and Intrafix system (Mitek Product, Johnson and Johnson, USA) in tibial tunnel. After tibial fixation, additional tibial post fixation was done, which was determined by the serial case number prospectively. Patients were followed for average of fourteen months(range, thirteen to twenty-five months) At the time of final follow-up, patients were evaluated in terms of Lachman test, pivot shift test, Lysholm scores, IKDC (International Knee Documentation Committee) assessment, side-to-side KT-1000 maximum-manual arthrometer differences. Results: At last follow-up, Lysholm score was average 93.1(range: 65 to 98), IKDC assessment revealed that 26 cases had score of A, 10 cases had score of B and 1 case had score of C. The average maximum-manual KT-1000 arthrometer side ?to-side difference was 2.5 mm$(0{\sim}6mm)$. There was one case in which the Lachman test was graded as 2+ and four cases in which the Lachman test was graded as 1+ and the remaining thirty-two cases were normal by Lachman test. One case had a 2+ pivot-shift, and 2 cases had a 11 pivot-shift. The remaining 34 knees were normal on pivot -shift testing. The average maximum-manual KT-1000 arthrometer side-to-side difference was average 2.8 mm$(0{\sim}6mm)$ in Intrafix only group and average 2.2 mm$(0{\sim}4mm)$ in additional fixation group (P>0.05). Conclusion: Without additional tibial fixation, the stability of the anterior cruciate reconstructed knee with hamstring graft which was fixed with Intrafix was restored.

  • PDF

Comparative Medium Term Results of Arthroscopic ACL Reconstruction with Quadrupled Semitendinosus Tendon versus BPB tendon (4겹의 반건양건과 골-슬개건-골을 이용한 관절경적 전방 십자 인대 재건술의 중기적 치료 결과 비교)

  • Kim, Hyoung-Soo;Park, Seung-Rim;Kang, Joon-Soon;Lee, Woo-Hyeong;Kim, Ki-Wook
    • Journal of the Korean Arthroscopy Society
    • /
    • v.5 no.1
    • /
    • pp.1-6
    • /
    • 2001
  • Purpose : The purpose of this study was to compare the postoperative success and stability of arthroscopically assisted anterior cruciate ligament(ACL) reconstructions using central one third bone-patellar-tendon bone(BPB) autograft versus quadrupled semitendinos-us(ST) autograft as the medium term review. Materials and Methods : Eighty patients(40 BPBs,40 STs) with isolated ACL injury were available for a mean follow up of 49.4 months(BPB) and 48.8 months(ST). There was no significant difference between the two groups with respect to age and sex. We compare the final results between two groups with respect to subjective Lysholm score, objective laxity including anterior drawer test, Lachman test, pivot shift test, KT-2000 measurements and International Knee Documentation Committee(IKDC) evaluation system. Results : Postoperatively, positive anterior drawer test was found in $22.5\%\;and\;27.5\%$, positive Lachman test was found in $30.0\%$ and $25.0\%$ and positive pivot shift test was found in $15\%\;and\;20\%$ of the ST and BPB group, respectively(p>0.05). Mean side to side difference of KT-2000 at 20 lbs was 2.2 mm for the ST group and 2.1 mm for the BPB group. There was no significant difference between the two groups about Lysholm score(>0.05). Anterior knee pain was knee common in the BPB group. Eighty-three percent of the patients were nearly normal according to the IKDC grade in both groups. Conclusion : We consider that autogenous semitendinosus tendon is a good alternative subsititute in ACL reconstruction together with the bone-patellar tendon-bone autograft.

  • PDF

The Outcome of Anterior Cruciate Ligament Reconstruction in Patients with Meniscal Injury (반월판 연골 손상이 동반된 환자에서 전방 십자 인대 재건술의 임상적 결과)

  • Lee Kwang Won;Park Jae Guk;Jung Yu Hun;Kim Byung Sung;Kim Ha Yong;Choy Won Sik
    • Journal of the Korean Arthroscopy Society
    • /
    • v.7 no.2
    • /
    • pp.160-168
    • /
    • 2003
  • Purpose : To analyze the anterior stability and functional results after the arthroscopic ACL reconstruction and meniscectomy based on meniscus status at the time of surgery. Materials and Methods : From October 1997 to October 2002, 78 patients (male 64 female 14) were treated by arthroscopic ACL reconstruction and meniscectomy and followed more than 12 months (range, $12\~72$ months, average: 32 months). Average age was 32 years old (range, $18\~57$ years old). We divided the patients into 4 groups; Both menisci was intact (BMI, control group), lateral meniscus removed (LMR), medial meniscus removed (MMR) and both menisci removed (BMR). Anterior passive displacement (objective stability) was estimated using KT-2000 arthrometer under the loading of 15lb,20lb and 30lb and evaluated anterior drawer test, Lachman test, range of motion, thigh circumference. Functional evaluation system of IKDC, OAK and Lysholm knee score was used. Results : Average anterior displacement under the loading of 30lb were 2.47 mm, 2.96 mm, 2.96 mm and 3.57 mm in each group(BMI, LMR, MMR, BMR) and it was statistically significant difference (p<0.05). There is no statistically significant difference in average anterior displacement under the loading of 15lb and 20lb in each group but it has showed decreasing tendency in meniscal removed groups. The mean anterior displacement was within 3 mm in 21 cases, 15 cases, 24 cases and 12 cases (total 72 cases, $94\%$) under the loading of 15lb and 20 cases, 15 cases, 24 cases and 11 cases (total 70 cases, $91\%$) under the loading 20lb of in each group and postoperative knee joint stability has showed increasing tendency (p>0.05). The mean score was 94.5, 93.2, 92.2 and 90.4 points in each group and 71 cases $(91\%)$ were more than excellent or good with a OAK score and fair results were noted 4 cases in both meniscal removed group. There were 65 cases $(83\%)$ with a Lysholm knee score more than excellent or good, and IKDC grading were more than normal or nearly normal in 74 cases $(95\%)$ except 4 cases (2 cases in MMR group and 2 cases in BMR group). Conclusion : Long-term anterior stability and functional results of a successful ACL reconstruction affected by tile status of the menisci at the time of surgery and KT-2000 arthrometer was good for estimation of objective follow up.

  • PDF

Usefulness of MRI 3D Image Reconstruction Techniques for the Diagnosis and Treatment of Femoral Acetabular Impingement Syndrome(Cam type) (대퇴 골두 충돌 증후군(Cam type)의 진단과 치료를 위한 자기공명 3D 영상 재구성 기법의 유용성)

  • Kwak, Yeong-Gon;Kim, Chong-Yeal;Cho, Yeong-Gi
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.11
    • /
    • pp.313-321
    • /
    • 2015
  • To minimize CT examination for Hip FAI diagnosis and operation plan. also, whether the MRI 3D images can replace Hip Clock face image was evaluated when performing Hip FAI MRI by using additional 3D image. This study analyzed Hip MRI and 3D Hip CT images of 31 patients in this hospital. For the purpose of evaluating the images, one orthopedic surgeon and one radiology specialist reconstructed Clock face, at MR and CT modality, by superior 12 o'clock, labrum front 3 o'clock, and the other side 9 o'clock, centering on Hip joint articular transverse ligament 6 o'clock. Afterwards, by the Likert Scale 5 point scale (independent t-test p<0.005), this study evaluated the check-up of A. retinacular vessel, B. head neck junction at 11 o'clock, A. Epiphyseal line, B. Cam lesion at 12 o'clock, and Cam lesion, Posterior Cam lesion at 1,2,3 and 4 o'clock. As for the verification of reliability among observers, this study verified coincidence by Cohen's weighted Kappa verification. As a result of Likert scale for the purpose of qualitative evaluation about the image, 11 o'clock A. retinacular vessel MR average was $3.69{\pm}1.0$ and CT average was $2.8{\pm}0.78$. B. head neck juncton didn't have a difference between two observers (p <0.416). 12 o'clock A. Epiphyseal line MR average was $3.54{\pm}1.00$ and CT average was $4.5{\pm}0.62$(p<0.000). B. Cam lesion didn't have a difference between two observers (p <0.532). 1,2,3,4 Cam lesion and Posterior Cam lesion were not statistically significant (p <0.656, p <0.658). As a result of weighted Kappa verification, 11 o'clock A.retinacular vessel CT K value was 0.663 and the lowest conformity. As a result of coincidence evaluation on respective item, a very high result was drawn, and two observers showed high reliability.

Anatomic Localization of Neurovascular Bundle at the Level of the Korean Knee Joint: A Magnetic Resonance Imaging Study (한국인의 슬관절에 위치한 신경-혈관 다발의 해부학적 위치: 자기공명영상 연구)

  • Kim, Yeung-Jin;Kim, Tae-Kyun;Yang, Hwan-Deok;Kim, Hyoung-Joon;Shim, Sung-Woo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.2
    • /
    • pp.102-106
    • /
    • 2008
  • Purpose: To evaluate the anatomical localization of neurovascular bundle at the level of the korean knee joint using a magnetic resonance imaging study and minimize the risk of neurovascular injury from arthroscopy surgery. Materials and Methods: The transverse and central axes were described on axial MRI scans of 100 korean knee joints. The distance between the neurovascular bundle and central axis was measured. The differences in neurovascular bundle localization according to sex and side were analyzed. The results were evaluated with SPSS(ver. 10.1). The influence of sex was evaluated by t-test. The difference between right and left side was evaluated by paired t-test. Significance was considered as p<0.05. Results: Whereas neurovascular bundle localization was lateral to the central axis in 94 cases(94%), it was on central axis in 6 cases(6%). There was no statistically significant difference of sex and side(P>0.05). Conclusion: Preoperative evaluation of neurovascular bundle with MR axial scans may prevent neurovascular injury when performing arthroscopic posterior cruciate ligament reconstruction and interventions on the posterior horns of menisci.

  • PDF

Histologic Change of Extracorporeal Irradiated Autogenous Joint Transplantation in Rabbit's Knee (가토에서 체외 방사선 조사후 재이식한 자가관절의 조직학적 변화)

  • Kim, Jae-Do;Cho, Myung-Rae;Yoo, Kyung-Sik;Kim, Young-Chang
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.5 no.1
    • /
    • pp.9-16
    • /
    • 1999
  • A new method of limb sparing by resection, extracorporeal irradiation and reimplantation has several theoretical advantages. This method preserves the mobility of a joint and avoids the problem of loosening or breakage of tumor prosthesis. This study involved using extracorporeal irradiated autogenous joint transplantation for reconstruction after en bloc resection, and observed the periods of functional union and histological changes in irradiated tissue of the knee joint. This study also aimed to clarify whether the degeneration of articular cartilage is induced in rabbits by a single 50Gy dose of irradiation at the knee joint. Twenty New Zealand rabbits about three kilograms were randomized into two groups of 10 rabbits each. In group 1, as control, we resected the knee joint followed by reimplantation without irradiation. Group 2 received extracorporeal irradiation on the resected knee joint followed by reimplantation. Following are the results of these observations. The osteotomy site showed external callus formation in the roentgenographic finding eight weeks after reimplantation. There was marked degenerative changes in the collagen fiber of the irradiated anterior cruciate ligament and meniscus during the fourth week, but new blood-vessel formation was observed in the vicinity. There was degenerative changes in the collagen fiber of articular cartilage treated extracorporeal irradiation at four and eight weeks in the scanning electron micrographic findings. These findings was in contrast to those of subchondral bone which showed decreased cellularity and empty lacuna at four and eight weeks. Autoradiography demonstrated active [$^3H$]uridine incorporation by irradiated chondrocyte at eight weeks after reimplantation. These results indicate that when destruction of the articular cartilage and soft tissue of the knee joint is not severe, extracorporeal irradiation and reimplantation can be used with several advantage in maintaining movement of the joint while avoiding problems of tumor prosthesis and rejection, and therefore extracorporeal irradiated autogenous joint transplantation can be used as a limb-sparing procedure for temporary biological spacer in the childhood bone tumor around the knee.

  • PDF