• Title/Summary/Keyword: Lift-off Test

Search Result 64, Processing Time 0.024 seconds

Shock Vibration Control of Hard-Disk Drive Using Coupled Shock Spectrum Analysis in Time-Frequency Domain (시간-주파수 영역에서의 연성 충격 스펙트럼 분석을 통한 하드디스크 드라이브의 충격진동 제어 (현장개발사례: SAMSUNG HDD 'SPINPOINT V40/P40 SERIES'))

  • Han, Yun-Sik;Kang, Seong-Woo;Oh, Dong-Ho;Hwang, Tae-Yeon;Son, Young
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.1111-1116
    • /
    • 2001
  • A transient T-F(time-frequency) signal processing technique is applied to a tilt drop and a linear shock test rigs for identification of shock characteristics of hard disk drive (HDD). The T-F technique essentially tracks the shock characteristics of pivot point response as well as head slap and lift-off phenomena. From the T-F analysis result, the shock characteristic in HDD is modeled by the two degree of freedom coupled-dynamic system, which consists of actuator arm and suspension. As shock designing tool, the maximax shock response spectrum is employed for prediction of shock performance. Finally, the shock control technique is tested with newly designed actuator arm and suspension. Experimental head slap test result shows that the shock performance is much higher with the new shockproof designed model than the current model

  • PDF

Subscapularis Tendon Rupture with Medial Dislocation of Biceps Tendon - Case Report - (견갑하근 건 파열과 동반된 상완 이두근 건 탈구)

  • Lee Byung-Ill;Kim Dong-Wook;Kim Dong-Jin;Min Kyung-Dae;Rah Soo-Kyoon
    • Clinics in Shoulder and Elbow
    • /
    • v.1 no.2
    • /
    • pp.147-153
    • /
    • 1998
  • Biceps tendon dislocation combined with rupture of subscapularis tendon is not a common lesion and there has been few case reported in Korea. We experienced one fifty Six years old male patient who shows typical features on physical examination and roentgenographic finding. He was injured by direct trauma on his right shoulder in adducted and external rotated position. He showed positive findings on passive external rotation test and lift-off test. On MR!, the subscpaularis tendon was totally ruptured and the biceps tendon was dislocated to anteromedial aspect of the glenoid labrum, which was typical finding. On the arthroscopic examination, the subscapularis tendon was totally ruptured from its humeral attachment and the biceps tendon was not seen in its normal anatomical position and it was dislocated antermedially to the glenoid labrum. We repaired the subscapularis tendon to humerus by use of suture anchor and the biceps tendon was relocated to its normal anatomical position in the intertubercular groove. On the post operative 6 months follow up, the patient shows improvements in his subjective symptoms and active range of motion.

  • PDF

Study on the Tensile Strength of Bleached Hair (탈색모발의 인장강도에 관한 연구)

  • Lee, Gui-Young;Chang, Byung-Soo
    • Applied Microscopy
    • /
    • v.38 no.3
    • /
    • pp.251-257
    • /
    • 2008
  • Human hair experience tensile forces during combing, bleaching and permanent dyeing processes. We have used rheometer to characterize bleached hair tensile response. Also, we investigated to morphological changes after tensile test of virgin hair and bleached hair using scanning electron microscopy. In tensile test, the tensile strength of virgin hair was $14.66g/cm^2$. They were measured as $12.95g/cm^2$, $12.61g/cm^2$ and $11.43g/cm^2$ for after the first, the second and the third trials of bleaching were done, respectively. Virgin hair had a higher tensile force than bleached hair. Tensile strength got lowered as more bleaching trials were done. In the observation of scanning electron microscopy, the fracture and lift-off of the cuticle outer layer were shown in virgin hair and bleached hair. The bleached hair were more lifted off at the outer cuticle layer than virgin hair. Consequently, chemical damage of bleaching agent caused weakening of the outer cuticle in the hair.

Measurement of Retaining Tensile Load with the Relative Displacement Detector of Ground Anchors (상대변위측정기를 이용한 지반앵커의 보유인장력 측정)

  • Jeong, Hyeon-Sik;Han, Kwang-Suk;Lee, Yeong-Saeng
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.10
    • /
    • pp.59-69
    • /
    • 2017
  • The tension load of the ground anchor inserted in the ground gradually changes over time. In this regard the change of the initial tension load is primarily decreased by the fixation condition of the fixing head and the mechanical characteristics of the tensile material. The subsequent additional tension load is a time-dependent loss mostly due to the fixing conditions of the bonded length and the surrounding ground properties of the field. In this paper, therefore, a measurement system using a relative displacement detector that can relatively easily measure the change of tension load is discussed. As a result of the review, it was confirmed that the results using the relative displacement detector are similar to those of the real scale model test, and it was also confirmed that similar results were obtained with the result of the pull-out test conducted on the ground anchors fixed to weathered rocks condition. In addition, a pull-out test was conducted on the test anchors whose initial tension load loss was relatively large and through this test pull-out behavior of the tension type ground anchors was verified.

Wind Tunnel Test on the Aerodynamic Characteristics of a PARWIG Craft (PARWIG선의 공력특성에 관한 풍동실험)

  • H.H. Chun;J.H. Chang;K.J. Paik;M.S. Shin
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.37 no.3
    • /
    • pp.57-68
    • /
    • 2000
  • The Power Augmented Ram(PAR) effect, which blows the down stream of the propellers into the underside of the wings and hence increases the pressure between the lower surface of the wings and the sea surface, is known significantly to enhance the performance of the WIG concept by reducing the take-off and landing speeds. The aerodynamic characteristics of a 20 passenger PARWIG are investigated by wind tunnel tests with the 1/20 scale model. The efflux of the forward mounted propellers are simulated by jet flows with a blower and duct system. The lift, drag, and pitch moment of the model with various ground clearances, angles of attack and flap angles are measured for the various jet velocities, jet nozzle angles, horizontal and vertical positions of the nozzle, and the nozzle diameters. The aerodynamic characteristics of the PARWIG due to these parametric changes are compared and pertinent discussions are included. It is shown that the proper use of the PAR can increase the lift coefficient of as much as up to 4.

  • PDF

Simulation of Remote Field Scanner for Defect Evaluation of Water Wall Tube Within the Fluidized Bed Boiler (유동층보일러 수냉벽튜브 결함평가를 위한 원격자장 스캐너 시뮬레이션에 관한 연구)

  • Gil, Doo-Song;Jung, Gye-Jo;Seo, Jung-Seok;Kim, Hak-Joon;Kwon, Chan-Wool
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.2
    • /
    • pp.145-150
    • /
    • 2020
  • Water wall tube is one of the major factors consisting of a fluidized bed boiler and it plays very important role for the generation of electricity within the boiler. But these water wall tubes within the fluidized bed boiler are subject to the ware and corrosion caused by the high temperature gas and the flowing medium. If water leak is occurred, the secondary damage by the water leak will occur. As a result of that, the power generation efficiency decreases noticeably. Therefore, the maintenance of the water wall tube is very important. In this study, we designed a exciter sensor based on simulation and composed a remote field eddy current system for the defect evaluation of the outer water wall tube. Starting from the shape design of exciter, we conducted simulations for various design factors such as the water wall tube size, material, frequency, lift-off and so on. Based on the results, we designed the optimum exciter sensor for the water wall tube test within the fluidized bed boiler.

System identification of a cable-stayed bridge using vibration responses measured by a wireless sensor network

  • Kim, Jeong-Tae;Ho, Duc-Duy;Nguyen, Khac-Duy;Hong, Dong-Soo;Shin, Sung Woo;Yun, Chung-Bang;Shinozuka, Masanobu
    • Smart Structures and Systems
    • /
    • v.11 no.5
    • /
    • pp.533-553
    • /
    • 2013
  • In this paper, system identification of a cable-stayed bridge in Korea, the Hwamyung Bridge, is performed using vibration responses measured by a wireless sensor system. First, an acceleration based-wireless sensor system is employed for the structural health monitoring of the bridge, and wireless sensor nodes are deployed on a deck, a pylon and several selected cables. Second, modal parameters of the bridge are obtained both from measured vibration responses and finite element (FE) analysis. Frequency domain decomposition and stochastic subspace identification methods are used to obtain the modal parameters from the measured vibration responses. The FE model of the bridge is established using commercial FE software package. Third, structural properties of the bridge are updated using a modal sensitivity-based method. The updating work improves the accuracy of the FE model so that structural behaviors of the bridge can be represented better using the updated FE model. Finally, cable forces of the selected cables are also identified and compared with both design and lift-off test values.

Vibro-acoustic Analysis of Simplified Satellite Model by Using the Statistical Energy Analysis Technique (단순화된 위성체의 통계적 에너지 해석법을 이용한 음향-진동 연성 해석)

  • Jeong, Cheol-Ho;Ih, Jeong-Guon;Moon, Sang-Moo;Kim, Hong-Bae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.711-714
    • /
    • 2002
  • At the lift-off condition, the combustion and Jet noise of launch vehicle produces a severe acoustic environment and the acoustic loads may be damaging to paylaod and equipments. Prediction of the acoustic environment is thus needed to support the load-resistive design and test-qualification of components. Currently, such a high frequency problem is usually dealt with by using the SEA technique, for which the assumptions should match reasonably well with the vibro-acoustic condition of system. The subsystems of SEA model was composed of 16 flat plates, 8 L-shaped beams, and 2 acoustic cavities. The frequency range was 400 Hz - 4 kHz considering the modal parameter. The experiment was performed in a high intensity acoustic chamber, in which the diffuse acoustic field was assured. By comparing the SEA analysis and the experiments, the error less than 5 dB was observed.

  • PDF

A Bootstrap Method for Analysis of Noise & Vibration Spectrum (부트스트랩 기법을 이용한 소음진동 스펙트럼 분석법 소개)

  • Chun, Young-Doo;Park, Jong-Chan;Chung, Eui-Seung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.185-188
    • /
    • 2008
  • This paper introduces the Bootstrap method for statistical analysis of noise and vibration spectrum in aeronautic and space fields. Generally, all components of a launch vehicle and its payloads are subjected to high intensive noise and vibration environment during the lift-off phase and the ascent phase through Mach =1 and Max Q. In order to verify their survivabilities against these severe vibroacoustic environments during qualification tests and acceptance tests, it is most important to estimate the proper upper limits of the environmental condition. Although NASA has typically utilized the Normal Tolerance Limit method in deriving these levels, the reference[1] says that the Bootstrap can be also an alternative method to estimate the maximum expected environments. In this paper, a general procedure of the Bootstrap method is summarized, and it is applied to analyze acceleration power spectral density functions, which were measured during acoustic test on the upper stage of KSLV-I.

  • PDF

Si 함유 DLC 필름의 탄성특성 평가

  • 정진원;조성진;이광렬;고대흥
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.136-136
    • /
    • 1999
  • 박막의 탄성특성을 평가하는 방법으로 nano-indentation, Brillouin light scattering measurement, ultrasonic surface wave measurement, bulge test, vibration membrane method 등 여러 가지가 제시되어 왔다. 최근에는 탄성특성을 평가할 수 있는 간단한 방법으로 기판 식각 기법을 이용한 freehang, bridge 방법이 제시되었다. 이중에서 bridge 방법은 간단한 식각 기법을 이용하여 얇은 박막에서도 탄성 특성을 평가할 수 있는 방법으로 제시되었다. 그러나 식각 과정에서 발생하는 patch 부분의 under-cut으로 인해 정확한 bridge의 길이를 측정할 수 없게 되어 오차가 발생하고 있다. 본 연구에서는 bridge 방법에서 발생하는 오차를 줄이기 위한 방법으로, patch 부분에 etch-stop을 제작해 줌으로서 식각 과정에서 발생하는 under-cut을 효과적으로 제거시켰다. Etch-stop은 2장의 mask를 align key를 이용하여 제작하였다. 먼저 산화막이 형성되어 있는 Si 기판위에 mask 1을 이용하여 patch 부분을 lithography 작업하고, 습식 식각 공정을 한 뒤 DLC 필름을 증착시킨다. 다음으로 mask 2를 이용하여 bridge pattern을 제작하고, DLC 필름을 증착시킨 후 lift-off 기술과 산화막 등방식각 공정을 통해 bridge를 제작하였다. 이렇게 제작된 bridge를 통해 필름이 기판에 부착되기 위해 필요한 변형률을 측정하고, 독립적으로 측정된 필름의 잔류응력과 함께 박막의 응력-변형률 관계식에 적용시켜 biaxial elastic modulus, E/(1-v)를 구할 수 있었다. Sidl 첨가된 DLC 필름은 rf-PACVD 장비를 이용하여 증착하였다. 이때 전극과 플라즈마 사이의 바이어스 음전압은 -400V로 합성압력은 10mTorr로 고정하였다. 사용한 반응가스는 벤젠(C6H6)과 희석된 실렌(SiH4:2H=10:90)이며, 희석된 실렌의 첨가량을 조절하여 필름 내에 함유된 Si의 양을 조절하였다. 각각의 조건에서 증착시간을 조절하여 필름의 두께를 조절하였다. 필름의 잔류응력은 압축잔류 응력에 의해 발생한 필름/기판 복합체의 곡률을 laser 반사법을 이용하여 측정하고, 이 결과를 Brenner 등에 의해 유도된 식을 대입하여 계산하였다.

  • PDF