• 제목/요약/키워드: Lifetime test

검색결과 525건 처리시간 0.026초

촉매성 산화물 전극 (DSA, Dimensionally Stable Anode)의 가속수명 테스트 방법과 장치에 관한 기초 연구 (A Basic Study on Accelerated Life Test Method and Device of DSA (Dimensionally Stable Anode) Electrode)

  • 김동석;박영식
    • 한국환경과학회지
    • /
    • 제27권6호
    • /
    • pp.467-475
    • /
    • 2018
  • The lifetime of the electrode is one of the most important factors on the stability of the electrode. Since the lifetime of the DSA (Dimensionally stable anode) electrode is long, an accelerated lifetime test is required to reduce the test time. Beacuse there is no basis or standard method for accelerated lifetime testing, many researchers use different methods. Therefore, there is a need for basis and methods for accelerated lifetime testing that other researchers can follow. We designed a reactor system for accelerated lifetime testing and planned specific methods. Reactor system was circulating batch reactor. Reactor volume and cooling water tank were 12.5 L and 100 L, respectively. Electrode size was $2cm{\times}3cm$ (real electrolysis area, $5cm^2$). In order to maintain the harsh conditions, accelerated lifetime test was carried out in a high current density ($0.6A/cm^2$) and low electrolyte concentration (NaCl, 0.068 mol/L). Maintaining a constant temperature was an important operation parameter for exact accelerated lifetime test. As the accelerated lifetime test progressed, the active component of electrode surface was consumed and desorption occurred. At the point of 5 V rise, corrosion of the surface of the base material(titanium) also started.

자동차용 유해가스 검출기의 신뢰성 평가기준 (Reliability Assessment Criteria of Air Quality System)

  • 최만엽;박동규;오근태;정해성
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제10권4호
    • /
    • pp.279-297
    • /
    • 2010
  • AQS(Air Quality Control System) is the important part of a car air conditioning system. This device intercepts automatically the influx of harmful waste gas. In this paper reliability assessment criteria for AQS are established in terms of quality certification test and lifetime test. The former quality certification test comprises general performance test and environmental test. Items which pass the test undergo lifetime test which guarantees the extent of mean lifetime with certain confidence.

자동차용 DPF 차압센서의 신뢰성 평가기준 (Reliability Assessment Criteria of Differential Pressure Sensor for DPF)

  • 정우영;민준원;박동규;최정운;최우석;김시동
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제15권1호
    • /
    • pp.67-75
    • /
    • 2015
  • Differential pressure sensor for DPF (Diesel Particulate Filter) is the important part of a automobile exhaust system. This device measures the pressure of before DOC and after DPF to determine whether the DPF regenerate. In this paper reliability assessment criteria for DPF differential pressure sensor are established on terms of quality calcification test and lifetime test. The former quality certification test comprises general performance test and environmental test. Items which pass the test undergo lifetime test which guarantees the extent of mean lifetime with certain confidence.

광기기 저장매체 구동용 BLDC 모터의 신뢰성 평가기준 (Reliability Assessment Criteria of Brushless Motor for Optical Disk Drive)

  • 송병석;천성일;정해성;백재욱
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제9권1호
    • /
    • pp.1-12
    • /
    • 2009
  • BLDC motors are stored in the devices such as CD-RW, COMBO, DVD-ROM and CD-ROM. It is indispensable to establish reliability assessment criteria for BLDC motors, especially in the world where IT grows rapidly. In this article, reliability certification procedure is given. The reliability certification procedure consists of two separate tests such as quality certification test and lifetime test. The former quality certification test comprises general performance test and environmental test. Items which pass the test undergo lifetime test which guarantees the extent of mean lifetime with certain confidence.

  • PDF

휴대폰용 전력증폭기의 신뢰성 평가기준 (Reliability Assessment Criteria of Power Amplifier for Mobile Phone)

  • 이우성;황순미;이관훈;송병석;정해성;오근태
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제9권3호
    • /
    • pp.233-248
    • /
    • 2009
  • PAM(Power Amplifier Module) is the important part of a mobile phone transmitter. It amplifies the strength of signal transmitting from a mobile phone to base stations enough to resist noise or interference. In this paper reliability assessment criteria for the PAM are established in terms of quality certification test and lifetime test. The former quality certification test comprises general performance test and environmental test. Items which pass the test undergo lifetime test which guarantees the extent of mean lifetime with certain confidence.

  • PDF

절단 방지용 방검소재의 가속수명시험 (Accelerated Life Test of Knife Protection Fabrics for Cut Resistance)

  • 장갑식;정예리;전병대
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제15권4호
    • /
    • pp.270-275
    • /
    • 2015
  • Purpose : UHMWPE (Ultra-high-molecular-weight-polyethylene) is one of the most widely used material in knife protection clothes because of high strength, elasticity, and light weight. The purpose of this study is to develop the accelerated life test method and predict the lifetime for the knife protection fabric composed by UHMWPE. Methods : In this study, degradation characteristics of UHMWPE fibers and knife protection fabric for cut resistance were evaluated under the hydrolysis and photo-degradation conditions. It was found out that the degradation rate of retained tensile strength was more significant in the photo-degradation than hydrolysis. Therefore, the failure time was determined as the time that the retained tensile strength in photo-degradation is less than 50%. Considering an acceleration factor for irradiance and exposure time, the lifetime was predicted from the calculated failure time. Results : As a result of the accelerated life test, the $B_{10}$ lifetime of knife protection fabric composed by UHMWPE fibers is estimated as 2.8 years for a 90% statistical confidence level. Conclusion: Since the lifetime is predicted by the view-point of radiant exposure in this study, there is a possibility that the estimated lifetime may differ from the actual lifetime. However, it is considered as an useful methodology to estimate the long-term lifetime of knife protection fabrics.

고장 진단 및 예지가 가능한 로봇용 감속기 내구성능평가 장치 개발 (Development of a Lifetime Test Bench for Robot Reducers for Fault Diagnosis and Failure Prognostics)

  • 신주성;김주현;김종걸;김무림
    • 드라이브 ㆍ 컨트롤
    • /
    • 제16권3호
    • /
    • pp.33-41
    • /
    • 2019
  • This study presents the development of a lifetime test bench for the strain wave reducer which is a precision gear reducer of the robot to realize fault diagnosis and failure prognostics. To this end, the lifetime test bench was designed to detect the vertical forward/reverse direction rotation load. Through the lifetime test bench, it is possible to apply the same load spectrum from robot working scenarios. We developed a data integration gateway for fault data collection. Through the development of dedicated software for fault diagnosis and failure prognostics, these data from vibration, noise and temperature sensors were collected and analyzed along with the operation of the lifetime evaluation.

전자식 전력량계의 수명평가 (Lifetime Assessment of Electronic Watt-hour Meters)

  • 설일호;박정원
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제9권1호
    • /
    • pp.37-45
    • /
    • 2009
  • Recently mechanical watt-hour meters are being replaced by electronic watt-hour meters. The replacement period of mechanical watt-hour meters is 7 years. This period is based on long term historical data. The replacement period of electronic watt-meters is also 7 years. This period is determined using the replacement period of mechanical watt-hour meters. However lifetime of mechanical watt-hour meters is different from the lifetime of electronic meters. In order to determine desirable replacement period of electronic watt-hour meters, accelerated life tests of major components in electronic watt-hour meters were performed. The test results showed that LCD was the component which had the shortest lifetime. In this paper, lifetime of electronic watt-hour meters manufactured by 3 company was estimated and life test standard for LCD was developed.

  • PDF

The Effect of MgO Rate Preparing Conditions and Xe Partial Pressure on the Relative Life time of an AC Plasma Display Panel

  • Park, Cha-Soo;Park, Min-Seok;Park, Joon-Young;Kim, Dong-Hyun;Lee, Ho-Jun;Park, Chung-Hoo
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제3C권2호
    • /
    • pp.35-42
    • /
    • 2003
  • This paper proposes a relative lifetime test method of MgO thin film. The suggested test conditions are 5$0^{\circ}C$, 400Torr, 20% over-voltage and 300KHz. The relative lifetime of MgO thin film is significantly affected by the MgO preparing conditions and Xe partial pressure. As result, the lifetime of the AC plasma display panel (PDP) is increased with an MgO thickness of 2000$\AA$ to 8000$\AA$ but is saturated over 5000$\AA$ (up to 9000 $\AA$). In addition, as Xe partial pressure increases, AC PDP lifetime increases.

가속 열 노화시험에 의한 탄성받침용 합성고무의 수명 예측에 관한 연구 (Accelerated Heat Aging Test for Predicting Useful Lifetime of Elastomeric Rearing)

  • 박광화;박준형;이하영;권영일
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제4권2호
    • /
    • pp.73-90
    • /
    • 2004
  • We performed the heat aging test to predict the useful lifetime of Elastomeric Bearing Chloroprene Rubber (CR) used for supporting bridge. During the test, we measured elongation that are influenced by temperature and aging time. The failure of a test piece is defined as the point at which the elongation reaches to 75% of the initial value. This failure criterion is based on KS F 4420: 1998 (Elastomeric Bearing for bridge). Through the accelerated heat aging test, we found that the Arrhenius relationship and the Weibull lifetime distribution are appropriate as the life-temperature relationship and lifetime distribution of the CR, respectively. Using the Arrhenius -Weibull model, the parameters of the model are estimated and the lifetime of the CR at use condition is predicted.

  • PDF