• Title/Summary/Keyword: LiF:Mg,Cu,Na,Si

Search Result 16, Processing Time 0.032 seconds

LiF(Mg, Cu, Na, Si) Thermoluminescent Dosimeters for In-phantom Dosimetry of $^{60}Co\;{\gamma}$-rays (LiF(Mg, Cu, Na, Si) 열형광선량계를 사용한 $^{60}Co\;{\gamma}^-$선의 수중 흡수선량 측정)

  • Kim, Hyun-Ja;Chung, Woon-Hyuk;Lee, Woo-Gyo;Doh, Sih-Hong
    • Journal of Radiation Protection and Research
    • /
    • v.15 no.2
    • /
    • pp.57-65
    • /
    • 1990
  • Newly developed LiF(Mg, Cu, Na, Si) thermoluminescence phosphors sealed in a plastic capsules (32mm dia., 0.9mm wall thickness) were used for in-phantom dosimetry of $^{60}Co$ $\gamma$-irradiation. The absorbed doses in water were determined by applying the general cavity theory to the absorbed dose in TLD cavity, which was computed from exposure. The absorbed doses at various sites in the water-phantom were measured by LiF(Mg, Cu, Na, Si) TLD and compared with doses obtained by the ionization method. Both results were consistent within the experimental fluctuation$({\pm}3%)$ Central axis percentage depth doses and phantom-air ratios measured by LiF(Mg. Cu, Na, Si) TLD showed good agreement with the published values[Br. J. Radiology, Suppl. 17(1983)].

  • PDF

Anneal Characteristics of LiF:Mg,Cu,Na,Si Teflon TLDs (LiF:Mg,Cu,Na,Si Teflon TLD의 열처리 특성)

  • Nam, Young-Mi;Chung, Woon-Hyuk;Lee, Dae-Won;Kim, Hyun-Ja;Kim, Gi-Dong
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.3
    • /
    • pp.135-141
    • /
    • 1997
  • The study of anneal characteristics is important for TL dosimeter to reuse. To obtain the annealing condition of the recently developed, new TL dosimeter, LiF:Mg,Cu,Na,Si Teflon Tills in a disk type (diameter 4.5 mm, thickness about $90mg/cm^2$), we studied for pre-irradiation annealing, readout procedure and post-readout annealing, in order. The gamma irradiations were carried out with a $^{60}Co$, dose of 0.1 Gy. We have used the method that observe the variation of thermoluminescent(TL) intensity of these Teflon TLDs over repeated cycles by changing both anneal temperature and anneal time with the TLD reader and the oven. There is a 5% loss in sensitivity over the ten repeated readouts by the annealing condition:pre-irradiation annealing at $80^{\circ}C$ for one hour, readout to $280^{\circ}C$ and post-readout annealing at $270^{\circ}C$ for 20 seconds.

  • PDF

Thermoluminescent Response of Thin LiF:Mg,Cu,Na,Si Detectors to Beta Radiation (얇은 LiF:Mg,Cu,Na,Si 검출기의 베타선장에 대한 TL 반응)

  • Nam, Y.M.;Kim, J.L.;Chang, S.Y.;Cho, H.W.;Kim, H.J.
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.1
    • /
    • pp.39-43
    • /
    • 1999
  • Thermoluminescent (TL) response characteristics of a thin LiF:Mg,Cu,Na,Si Teflon detectors have been studied for use in beta radiation detection. The detectors were fabricated from a mixture of LiF:Mg,Cu,Na,Si phosphor and Teflon powder which was molded into a thin disk form of $50mg/cm^2$ thickness. These detectors were irradiated to beta fields of $^{147}Pm,\;^{204}Tl\;and\;^{90}Sr/^{90}Y$ sources with a covering of Kapton foil ($2mg/cm^2$) and photon irradiation was carried out with a $^{137}Cs$ source at the Korea Atomic Energy Research Institute (KAERI). Batch uniformity was estimated to be 4.7% and the beta dose response presented linear relationship from 0.1 mGy to 100 Gy. The beta energy responses of thin detectors normalized to $^{137}Cs$ were presented as 0.46, 1.09 and 1.06 for $^{147}Pm,\;^{204}Tl\;and\;^{90}Sr/^{90}Y$ beta rays, respectively. The evaluated values for angular responses were $0.93{\pm}0.03\;(^{147}Pm),\;0.94{\pm}0.04\;(^{204}Tl),\;and\;0.92{\pm}0.05\;(^{90}Sr/^{90}Y)$. The results satisfied well a proposed ISO Standard for beta ray dosimeters.

  • PDF

Dosimetric Properties of LiF:Mg,Cu,Na,Si TL pellets (LiF:Mg,Cu,Na,Si TL 소자의 선량계적 특성)

  • Nam, Young-Mi;Kim, Jang-Lyul;Chang, Si-Young
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.1
    • /
    • pp.7-12
    • /
    • 2001
  • Sintered LiF:Mg,Cu,Na,Si thermoluminescence (TL) pellets were developed for application in radiation dosimetry. In the present study, the TL dosimetric properties of LiF:Mg,Cu,Na,Si TL pellets have been investigated for emission spectrum, dose response, energy response, and fading characteristics. LiF:Mg,Cu,Na,Si TL pellets were made by using a sintering process, that is, pressing and heat treatment from TL powders. Photon irradiations for the experiments were carried out using X-ray beams and a $^{137}Cs$ gamma source at the Korea Atomic Energy Research Institute (KAERI). The average energies and the dose were in the range of 20-662 keV and $10^{-6}-10^{-2}\;Gy$, respectively. The glow curves were measured with a manual type TLD reader(System 310, Teledyne) at a constant nitrogen flux and a linear heating rate. For a constant heating rate of $5^{\circ}C\;s^{-1}$, the main dosimetric peak of glow curve appeared at $234^{\circ}C$, the activation energy was 2.34 eV and frequency factor was $1.00{\times}10^{23}$. TL emission spectrum is appeared at the blue region centered at 410 nm. A linearity of photon dose response was maintained up to 100 Gy. The photon energy responses relative to $^{137}Cs$ response were within ${\pm}20%$ at overall photon energy region. The fading of TL sensitivity of the pellets stored at the room temperature was not found for one year.

  • PDF

Generation of LiF(Mg,Cu,Na,Si) thermoluminescent crystal and evaluation of dose response and sensitivity

  • Abdollah Khorshidi
    • Nuclear Engineering and Technology
    • /
    • v.56 no.7
    • /
    • pp.2790-2798
    • /
    • 2024
  • In this research, thermoluminescent pellets were prepared by adding Mg, Cu, Na and Si impurities to lithium fluoride (LiF) crystal powder via melting and quenching methods to study dosimetric characteristics. Here, its reproducibility, dose response, dosimeter sensitivity, thermal and optical fading were investigated and the obtained results were compared with the properties of LiF: Cu, Mg, P crystal nominated as GR-200.

The Measurement and Analysis of LiF:Mg, Cu, Na, Si TL Material by Thermoluminescence Spectrum (LiF:Mg, Cu, Na, Si TL 물질의 열자극발광스펙트럼 측정 및 분석)

  • Lee, J.I.;Moon, J.H.;Kim, D.H.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.149-153
    • /
    • 2001
  • Three-dimensional thermoluminescence(TL) spectra of LiF: Mg, Cu, Na, Si TL material based on temperature, wavelength and intensity were measured and analyzed. The glow curves were obtained by integration of luminescence intensity for wavelength at each temperature, and various trapping parameters related to the trap formation were determined by analyzing these curves. Computerized glow curve deconvolution(CGCD) method which based on general order kinetics(GOK) model were used for the glow curve analysis. The glow curves of LiF:Mg, Cu, Na, Si TL material were deconvoluted to six isolated glow curves which have peak temperature at 333 K, 374 K, 426 K, 466 K, 483 K and 516 K, respectively. The 466 K main glow peak had an activation energy of 2.06 eV and a kinetic order of 1.05. This TL material was also found to have three recombination centers, 1.80 eV, 2.88 eV and 3.27 eV by TL spectra analysis based on Franck-Condon model. It showed that 2.88 eV is the dominant center, followed by 3.27 eV level, and 1.80 eV center is ascertained as emission center of this material even though its very weak emission intensity.

  • PDF

Preparation of Radiation Detector and Radiation Dosimetry - TSEE Charactristics of LiF ( Mg , Cu , Na , Si ) Phosphor - (방사선 검출기의 제작과 방사선 선량측정 - LIF ( Mg , Cu , Na , Si ) 형광체의 TSEE 특성 -)

  • 도시홍
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.27 no.4
    • /
    • pp.328-331
    • /
    • 1991
  • LiF(Mg,Cu,Na,Si) 형광체의 ${\gamma}$선과 $\beta$선에 대한 TSEE 특성을 조사하였다. 상(60)Co ${\gamma}$선에 대한 감도는 약 450 counts/mR이었고, 여러 가지 $\beta$선에 대한 TSEE 에너지 의존성은 $\beta$입자의 평균에너지 0.02MeV에서 0.8MeV 사이에서 $\pm$10%이었다. 그리고 제작된 형광체 앞면에 7mg.cm 상(-2)의 인체 등가물질을 두 면 입사 $\beta$입자의 에너지에 무관하게 피부 흡수 선량을 측정할 수 있었다.

  • PDF