일중효용 사이클과 일중효용/2단승온 사이클을 이용한 태양열 흡수식 냉방시스템의 비교 (Comparison Between Two Solar Absorption Cooling System Using Single Effect and Single Effect/Double Lift Cycle)

  • 정시영;이상수;조광운;백남춘
    • 설비공학논문집
    • /
    • 제12권3호
    • /
    • pp.267-276
    • /
    • 2000
  • A numerical study has been carried out to find out the optimal design condition of a solar absorption cooling system. The system was composed of solar collectors and an absorption chiller with LiBr/water The System performance with commercial single effect(SE) cycle and a new single effect/double lift(SE/DL) cycle utilizing low temperature hot water was calculated and compared. It was found that the required solar collector area grew exponentially as the overall heat loss coefficient of solar collectors increased. For instance, the required area for cooling capacity of 1 USRT was $17m^2$ if heat loss coefficient was 4 W/$m^2\;cdot\;K$. If heat loss coefficient was doubled($8\;W/m^2\;cdot\;$K), the required collector area was increased by 6 times($100m^2$) .It was also found that the SE-cycle as the heat loss coefficient of solar collectors increased. Generally, a SE/DL-cycle seems to be more advantageous than a SE-cycle if loss coefficient of solar collector is greater than 4 W/$m^2\;cdot\;K$.

  • PDF

가스흡수식 냉온수기 열교환기용 세관의 부식특성에 관한 연구 (The Study on Corrosion Characteristics of Heat Exchanger Tube for Gas Absorption Refrigeration & Hot Water System)

  • 정기철
    • 한국가스학회지
    • /
    • 제6권1호
    • /
    • pp.92-97
    • /
    • 2002
  • 가스흡수식 냉온수기의 작동매체로 사용되고 있는 LiBr 수용액 중에서 열교환기 세관용 재료인 동 세관 및 동합금재인 큐프로니켈 세관의 부식특성에 관한 연두를 하기 위하여 $62\%$ LiBr 수용액 중에서 각 재료에 대한 전기화학적 분극실험을 실시하여 부식특성을 고찰한 결과 다음과 같은 결론을 얻었다 1) 열교환기 세관재의 분극저항은 $30\%$ 큐프로니켈 세관 > $10\%$ 큐프로니켈 세관 > 동 세관의 순으로 높게 나타난다 2) 큐프로니켈 세관의 개로전위는 동 세관보다 귀전위화되면서 부식전류밑도는 더 억제된다 3) $30\%$ 큐프로니켈 세관의 부동태 영역은 $10\%$ 큐프로니켈 세관보다 전위구간이 더 크게. 나타나면서 부동태유지 전류밀도는 더 낮아진다.

  • PDF

수평관군 흡수기의 열 및 물질 전달특성에 관한 실험적 연구 (Experimental Study on Heat and Mass Transfer Characteristics in bundles of horizontal absorption tubes)

  • 설원실;정용욱;문춘근;윤정인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권3호
    • /
    • pp.113-120
    • /
    • 2000
  • On the absorber of absorption chiller/heater, LiBr solution at high concentration is sprinkled on a bundle of horizontal tube cooled by cooling water. In this case, the conditions of LiBr solution and cooling water have an influence on heat/mass transfer coefficient in this system. Therefor it is important to find optimal operation conditions of absorption chiller/heater to save energy. Heat and mass transfer coefficient increased with the increase of solution flow rate, and also heat and mass transfer rate increased but overall heat and mass transfer coefficient decreased by increasing the solution concentration within the experimental range. The superheating of the solution resulted in superior heat transfer character to a state of equilibrium from the point of heat flux and overall heat transfer coefficient.

  • PDF

Integral Analysis of the Effects of Non-absorbable gases on the Heat Mass Transfer of Laminar Falling Film

  • Kim, Byong-Joo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.56-66
    • /
    • 1998
  • The absorption process of water vapor in a liquid film is an important process in LiBr-Water absorption system. The composition of the gas phase, in which a non-absorbable gas is combined with the absorbate, influences the transport characteristics. In the present work, the absorption processes of water vapor into aqueous solutions of lithium bromide in the presence of non-absorbable gas are investigated. The continuity, momentum, energy and diffusion equations for the solution film and gas are formulated in integral forms and solved numerically. It is found that the mass transfer resistance in gas phase increases with the concentration of non-absorbable gas. However the primary resistance to mass transfer is in the liquid phase. As the concentration of non-absorbable gas in the absorbate increases, the interfacial temperature and concentration of absorbate in solution decrease, which results in the reduction of absorption rate. The reduction of mass transfer rate is found to be significant for the addition of a small amount of non-absorbable gas to the pure vapor, especially at the outlet of tube where the non-absorbable gas accumulates. At higher non-absorbable gas concentration, the decrease of absorption rate seems to be linear to the concentration of non-absorbable gas.

  • PDF

제 2종 LiBr-H2O 흡수식 히트펌프의 운전 변수에 따른 성능 특성 수치 해석 (Effects of Operation Conditions on the Performance of Type II LiBr-H2O Absorption Heat Pump)

  • 윤준성;권오경;차동안;배경진;김인관;김민수;박찬우
    • 설비공학논문집
    • /
    • 제29권1호
    • /
    • pp.7-14
    • /
    • 2017
  • This study carried out a numerical analysis of the effects of hot waste water supply on the performance of a Type II absorption heat pump. There are two types of hot waste water supply, regular series flow and reverse series flow. Also it investigated the interaction between each type of flow and heat exchange solutions. As the effectiveness of heat exchange solutions increase, the steam generation and (COP) increase as well. If the effectiveness of a heat exchange solution is lower than 0.566, the steam generation rate of the reverse flow is lower than that of the regular series flow. A high effectiveness of heat exchange solution is therefore required to make a larger amount of steam in reverse series flow than with ordinary series flow. The COP difference between the two types of flow decreases with the increasing effectiveness of the heat exchange solution. Thus, a reverse flow type absorption heat pump can match the high steam generation rate and COP of the ordinary flow type when a highly effective heat exchange solution is applied.

공랭형 수직원관 흡수기에서의 열 및 물질전달 해석 (Analysis of heat and mass transfer in a vertical tube absorber cooled by air)

  • 김선창;오명도;이재헌
    • 대한기계학회논문집B
    • /
    • 제20권10호
    • /
    • pp.3293-3303
    • /
    • 1996
  • Numerical analyses have been performed to estimate the absorption heat and mass transfer coefficients in absorption process of the LiBr aqueous solution and the total heat and mass transfer rates in a vertical tube absorber which is coolING ed by air. Axisymmetric cylindrical coordinate system was adopted to model the circular tube and the transport equations were solved by the finite volume method. Absorption behaviors of heat and mass transfer were analyzed through falling film of the LiBr aqueous solution contacted by water vapor in tube. Effects of film Reynolds number on heat and mass transfer coefficients have been also investigated. Especially, effects of tube diameter have been considered to observe the total heat and mass transfer rates through falling film along the tube. Based on the analysis it has been found that the total mass transfer rate increases rapidly in a region with low film Reynolds number(10 ~ 40) as the film Reynolds number increases, while decreases beyond that region. The total heat and mass transfer rates increase with increasing the tube diameter.

Noncondensable gas's influence in waster vapor absorption accompanying interfacial disturbance into aqueous solution of LiBr

  • Dong-Ho RIE;Keun-Oh Lee
    • 한국안전학회지
    • /
    • 제7권2호
    • /
    • pp.63-70
    • /
    • 1992
  • 흡수식 열펌프에서 폭 넓게 사용되고 있는 대표적인 냉매/흡수용액은 $H_2O$ / LiBr 계이다 그러나, LiBr 수용액의 점성계수는 LiBr의 농도가 커짐에 따라 증가하기 때문에, LiBr수용액의 농용액 영역에서 물질확산계수가 감소한다. 이 결점을 보완하기 위해 흡수용액에 계면활성제를 첨가시키므로서 흡수를 촉진시키는 방식을 이용하고 있다. 계면활성제의 첨가에 의한 흡수용액의 열 및 물질이동 촉진에 관한 연구는 계면활성제 첨가농도에 의해 흡수용액의 표면상에서 게면활성제가 액적으로 존재하는 계면활성제 포화용해도 이상의 조건에서 발생하는 마랑고니대류가 효과적이다. 이 흡수촉진효과는 냉매증기의 흡수시 흡수용액표면상의 분포한 계면활성제와 흡수용액사이의 표면장력차에 기인하는 계면교한 현상에 기인한다. 그러나, 이흡수촉지효과는 냉매증기의 흡수가 일어나는 흡수기 내부의 不안정상태, 즉, 불응축성가스(공기)가 존재하지 않는 조건하에서 이루어지며, 불응축성가스가 흡수촉진저하(열 및 물질이동의 저하)에 기인하는 연구는 보고된 바 없다. 이러한 불응축성가스가 흡수기 내부에 존재할 때 계면교한의 거동 및 열 및 물질이동저하현상을 파악하기 위하여 계면활성제 농도변화(포화용해도 이상 및 이하의 두 조건)에 따른 증기흡수 실험 및 계면교한가시화 실험을 행하였다. 결과적으로 본실험을 통하여 불응축성가스가 수증기흡수에 끼치는 영향을 파악(계면교란의 악화) 첨가시의 흡수량과 不安定상태(불응축성가스가 존재시)의 증기흡수량의 비교에 의해 급격한 증기흡수저하가 不安定상태하에서 발생함으로서 불응축성가스가 흡수촉진효과(계면교한현상)을 저해시키는 결론을 얻었다.es and facts obtained by the expenence in this area, respectively. Both depth-first search and backward chaining schemes are used in reasoning process. This expert system is written in an artificial intelligence language "PROLOG", and its availability is demonstrated through the case study.e함량은 감소되었으며 sulfhydryl기가 증가됨에 따라서 disulfide groups은 감소되는 경향을 보였고 ascorbic acid는 열처리 온도뿐만 아니라 시간과도 관련이 있음을 알 수 있었다. 저온 살균유와 초고온 살균유 사이에서는 지표물질들의 함량이 다소 차이가 있음을 볼 수 있었다.담시간이 구체적으로 기술되지 않았으며, 고유한 언어를 통역하는 과정에서 의미론적 문제에 대한 고려가 부족하였다. 면접과 기록과정에서 보면 자료의 기록과정과 분류 및 분석과정이 명시되어 있지 않았다. 참여관찰과 면접방법을 사용시 이에 대한 자세한 기술이 되어 있지 않았다. 5. 연구결과의 적용 및 이에 대한 논의는 상당히 제한되어 있었는데, 수편의 연구만이 방법론 문제점과 앞으로의 연구분야에 대한 전망을 제시하였으며, 특이한 것은 어 떤 연구자도 이른 개발을 위한 적용 및 임상실무적 차원에서 간호에 대한 제언을 하지 않았다.유모델변수들은 유입-유출 자료들로부터 평가할 수 있으며, 이를 위해서 본 논문에서는 Gauss-Newton 방법을 이용한 Bard

  • PDF

Non-absorbable Gas Effects on Heat and Mass Transfer in Falling Film Absorption

  • Kim, Byongjoo;Lee, Chunkyu
    • Journal of Mechanical Science and Technology
    • /
    • 제17권4호
    • /
    • pp.581-589
    • /
    • 2003
  • Film absorption involves simultaneous heat and mass transfer in the gas-liquid system. While the non-absorbable gas does not participate directly In the absorption process. its pretence does affect the overall heat and mass transfer. An experimental study was performed to investigate the heat and mass transfer characteristics of LiBr-H$_2$O solution flow ing over 6-row horizontal tubes with the water vapor absorption in the pretence of non-absorbable gases. The volumetric concentration of non-absorbable gas, air, was varied from 0.17 to 10.0%. The combined effects of the solution flow rate and its concentration on the heat and mass transfer coefficients were also examined. The presence of 2% volumetric concentration of air resulted in a 25% reduction in the Nusselt number and 41% reduction in the Sherwood number Optimum film Reynolds number was found to exist at which the heat and mass transfer reach their maximum value independent of air contents. Reduced Nusselt and Sherwood numbers. defined as the ratio of Nusselt and Sherwood numbers at given non-absorbable gas content to that with pure water vapor, were correlated to account for the reduction in the heat and mass transfer due to non-absorbable gases in a falling film absorption process.

흡수압축 하이브리드 히트펌프 사이클의 성능특성 (Performance Characteristic of the Compression-Absorption Hybrid Heat Pump Cycles)

  • 윤정인;권오경;양영명
    • 한국가스학회지
    • /
    • 제3권1호
    • /
    • pp.14-20
    • /
    • 1999
  • [ $H_2O/LiBr$ ]계 흡수식 사이클에 압축기를 조합한 흡수압축사이클을 도입하여 증기를 단열압축시켜 그 증기의 응축열을 재생열로 이용하는 사이클에 대해서 시뮬레이션을 통하여 횹수압축사이클의 특성을 밝힌 연구이다. 기존의 흡수사이클에 압축기를 도입함에 따라 고효율 사이클을 실현할 수 있음을 제시하였으며, 흡수$\cdot$압축사이클의 구체적인 가능성을 제시하였다. 재생기에서 발생한 냉매증기를 단열압축시킨 TYPE 2는 단열압축 증기의 응축열만으로는 재생이 어려우므로 외부로부터 별도의 열량을 투입해야 하며 투입하는 외부열량에 폐열이나 2차 에너지를 이용할 수 있다면 높은 COP를 얻을 수 있어 실현가능성이 높다.

  • PDF

냉매 열교환기 구성방법에 따른 제 2종 흡수식 히트펌프의 성능 특성 변화에 관한 연구 (Performance Characteristics of Type II LiBr-H2O Absorption Heat Pump in Accordance with the Refrigerant Heat Exchanger Configuration)

  • 이창현;윤준성;김인관;권오경;차동안;배경진;김민수;박찬우
    • 설비공학논문집
    • /
    • 제29권7호
    • /
    • pp.373-384
    • /
    • 2017
  • The objective of this study was to determine the effect of refrigerant heat exchanger on the performance of type II absorption heat pump performance using numerical analysis. Two heat exchange installation methods were used: solution to refrigerant and waste hot water to refrigerant. These methods were compared to the standard model of hot water flow without using refrigerant heat exchanger. When waste hot waters were bypassed to refrigerant heat exchanger, COP was not affected. However, steam mass generation rates were increased compared to those of the standard model. When solutions were bypassed to the refrigerant heat exchanger, results were different depending on the place where the solution rejoined. COP and steam mass generation rates were lower compared to those when waste heat water was passed to refrigerant heat exchanger. Thus, it is possible to obtain higher steam mass generation rates by using waste water and installing refrigerant heat exchanger.