• Title/Summary/Keyword: Lever Arm

Search Result 51, Processing Time 0.021 seconds

Finite element analysis of effectiveness of lever arm in lingual sliding mechanics (Lingual sliding mechanics의 lever arm 효과에 대한 유한요소분석)

  • Kim, Kyeong-Hee;Lee, Kee-Joon;Cha, Jung-Yul;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.41 no.5
    • /
    • pp.324-336
    • /
    • 2011
  • Objective: The aim of this study was to conduct three-dimensional finite element analysis of individual tooth displacement and stress distribution when a posterior retraction force of 200 g was applied at different positions of the retraction hook on the transpalatal arch (TPA) of a molar, and over different lengths of the lever arm on the maxillary anterior teeth in lingual orthodontics. Methods: A three-dimensional finite element model, including the entire upper dentition, periodontal ligaments, and alveolar bones, was constructed on the basis of a sample (Nissan Dental Product, Kyoto, Japan) survey of Asian adults. Individual movement of the incisal edge and root apex was estimated along the x-, y-, and z-coordinates to analyze tooth displacement and von Mises stress distribution. Results: When the length of the lever arm was 15 mm and 20 mm, the incisal edge and root apex of the anterior teeth was displaced lingually, with a maximum lingual displacement at the lever arm length of 20 mm. When the posterior retraction hook was on the root apex, the molars showed distal displacement. When the length of the lever arm was 20 mm, anterior extrusion was reduced and the crown of the canine displaced toward the buccal side, in which case, the retraction hook was on the edge, rather than at the center, of the TPA. Conclusions: The results of the analysis showed that when 6 anterior teeth were retracted posteriorly, lateral displacement of the canine and lingual displacement of the incisal edge and root apex of the anterior teeth occur without the extrusion of the anterior segment when the length of the lever arm is longer, and the posterior retraction hook is in the midpalatal area.

$H_{\infty}$ filter for flexure deformation and lever arm effect compensation in M/S INS integration

  • Liu, Xixiang;Xu, Xiaosu;Wang, Lihui;Li, Yinyin;Liu, Yiting
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.6 no.3
    • /
    • pp.626-637
    • /
    • 2014
  • On ship, especially on large ship, the flexure deformation between Master (M)/Slave (S) Inertial Navigation System (INS) is a key factor which determines the accuracy of the integrated system of M/S INS. In engineering this flexure deformation will be increased with the added ship size. In the M/S INS integrated system, the attitude error between MINS and SINS cannot really reflect the misalignment angle change of SINS due to the flexure deformation. At the same time, the flexure deformation will bring the change of the lever arm size, which further induces the uncertainty of lever arm velocity, resulting in the velocity matching error. To solve this problem, a $H_{\infty}$ algorithm is proposed, in which the attitude and velocity matching error caused by deformation is considered as measurement noise with limited energy, and measurement noise will be restrained by the robustness of $H_{\infty}$ filter. Based on the classical "attitude plus velocity" matching method, the progress of M/S INS information fusion is simulated and compared by using three kinds of schemes, which are known and unknown flexure deformation with standard Kalman filter, and unknown flexure deformation with $H_{\infty}$ filter, respectively. Simulation results indicate that $H_{\infty}$ filter can effectively improve the accuracy of information fusion when flexure deformation is unknown but non-ignorable.

A Mathematical Modeling for the Physical Relationship between Camera and the Unknown Initial State of INS (카메라와 초기상태 정보가 없는 INS간 물리적 관계를 위한 수학적 모델링)

  • Chon Jae-Choon;Shibasaki Ryosuke;Zhao Huijing
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2006.04a
    • /
    • pp.145-149
    • /
    • 2006
  • 모바일 맹핑시스템에 장착되어 있는 카메라와 INS의 물리적 관계 (두 좌표축 간의 거리(lever-arm) 와 각도(boresight) 캘리브레이션은 카메라 영상의 지리적 정보를 생성하기 위해 필요로 한다. 이 목적을 위해 기존연구는 카메라 캘리브레이션을 통하여 이 물리적 관계를 추정하고 있다. 카메라 캘리브레이션은 3차원 좌표가 할당된 타겟을 이용하여 움직이는 카메라의 렌즈 왜곡과 내/외부 표정 계산하는 것이다. 이 추정에서, 저가의 INS의 초기상태인 자세, 각도는 사용자의 측량에 의해 결정이 된다. 만약 정교한 측량이 없을 경우, 카메라 영상의 지리적 정보는 잘못된 정보를 제공 할 것이다. 정교한 측량의 어려움을 피하기 위해, 본 논문은 카메라와 초기상태 정보가 없는 INS간의 물리적 관계를 위한 수학적 모델을 설계하였다. 시스템에 장착된 카메라와 INS의 초기 기준 좌표계의 관계는 lever-arm과 boresight을 이용한 좌표축 변환으로 정의 될 수 있으며, 이 시스템이 이동 후, 카메라 초기 기준 좌표계에서 INS의 위치는 두 개의 벡터 경로로 정의 될 수 있다. 이 두 벡터 경로는 카메라와 INS의 상대 외부표정의 관계를 이용하여 계산된 벡터들의 조합으로 정의된다. 본 논문은 여러 쌍의 경로로부터 lever-arm과 boresight을 추정하였다.

  • PDF

Comparison of inclination and vertical changes between single-wire and double-wire retraction techniques in lingual orthodontics

  • Hung, Bui Quang;Hong, Mihee;Yu, Wonjae;Kyung, Hee-Moon
    • The korean journal of orthodontics
    • /
    • v.50 no.1
    • /
    • pp.26-32
    • /
    • 2020
  • Objective: The Heat Induction Typodont System (HITS), used in some recent studies, has a distinct advantage over previous tooth movement simulation methods. This study aimed to compare inclination and vertical changes between the single-wire and double-wire techniques during en masse retraction with different lengths of lever arms in lingual orthodontics using an upgraded version of the HITS. Methods: Duet lingual brackets, which have two main slots, were used in this study. Forty samples were divided into four groups according to the length of the lever arm (3-mm or 6-mm hook) and the retraction wire (single-wire or double-wire). Four millimeters of en masse retraction was performed using lingual appliances. Thereafter, 3-dimensional-scanned images of the typodont were analyzed to measure inclination and vertical changes of the anterior teeth. Results: Incisor inclination presented more changes in the single-wire groups than in the double-wire groups. However, canine inclination did not differ between these groups. Regarding vertical changes, only the lateral incisors in the single-wire groups presented significantly larger values than did those in the double-wire groups. Combining the effect of hook lengths, among the four groups, the single-wire group with the 3-mm hook had the highest value, while the double-wire group with the 6-mm hook showed the least decrease in crown inclination and extrusion. Conclusions: The double-wire technique with an extended lever arm provided advantages over the single-wire technique with the same lever arm length in preventing torque loss and extrusion of the anterior teeth during en masse retraction in lingual orthodontics.

Palatal en-masse retraction of segmented maxillary anterior teeth: A finite element study

  • Park, Jae Hyun;Kook, Yoon-Ah;Kojima, Yukio;Yun, Sunock;Chae, Jong-Moon
    • The korean journal of orthodontics
    • /
    • v.49 no.3
    • /
    • pp.188-193
    • /
    • 2019
  • Objective: The aim of this finite element study was to clarify the mechanics of tooth movement in palatal en-masse retraction of segmented maxillary anterior teeth by using anchor screws and lever arms. Methods: A three-dimensional finite element method was used to simulate overall orthodontic tooth movements. The line of action of the force was varied by changing both the lever arm height and anchor screw position. Results: When the line of action of the force passed through the center of resistance (CR), the anterior teeth showed translation. However, when the line of action was not perpendicular to the long axis of the anterior teeth, the anterior teeth moved bodily with an unexpected intrusion even though the force was transmitted horizontally. To move the anterior teeth bodily without intrusion and extrusion, a downward force passing through the CR was necessary. When the line of action of the force passed apical to the CR, the anterior teeth tipped counterclockwise during retraction, and when the line of action of the force passed coronal to the CR, the anterior teeth tipped clockwise during retraction. Conclusions: The movement pattern of the anterior teeth changed depending on the combination of lever arm height and anchor screw position. However, this pattern may be unpredictable in clinical settings because the movement direction is not always equal to the force direction.

Shear Compatibility Condition with Arch Action in Simply Supported RC Beam (단순지지된 RC보에서의 아치효과를 고려한 전단변형적합조건)

  • Lee, Seong-Chul;Cho, Jae-Yeol;Kim, Woo;Park, Byung-Sun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.847-850
    • /
    • 2008
  • In simply supported concrete beams with concentrated load, there is arch action that the internal lever arm length varies through shear span. Recently shear analysis model considering this effect has been developed, but the analysis algorithm is so complicated. Moreover, the variation of internal lever arm length is not considered on the shear compatibility condition. In this study, the shear analysis model is developed more simply and the variation of internal lever arm length is considered on the shear compatibility condition. From these modifications, an actual shear behavior of RC beams subjected to concentrated load could be expected from the results of the proposed analysis model.

  • PDF

A Study on the Displacement Magnification Mechanism of Two-Lever System using Flexure Hinge (유연 힌지를 이용한 이중레버 시스템의 변위증폭 메카니즘에 관한 연구)

  • Jea, Wone-Soo;Ye, Sang-Don;Min, Byeong-Hyeon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.7 no.2
    • /
    • pp.60-65
    • /
    • 2008
  • The high-technology industries including a semi-conductor and an information communication need an ultra-precision technology from the technological points of view. Nano technology based on an ultra-precision technology is being studied to overcome the delicate technology that may occur in the semi-conductor fields. Then, the transferring equipment with high resolution and long displacement becomes an important technology. The goal of this study is to analyze the displacement magnification mechanism driven by piezoelectric actuator which has high resolution and fast response characteristics using flexure hinge with the merits of soft displacement, negligible back-lash and stick-slip, and no-lubrication. The analyses to reduce the magnification losses occurred during the magnification process are performed using ANSYS software based on FEM. The five design variables such as arm thickness, thickness of hinge, radius of hinge, length of input side at the 1st lever and magnification ratio of 1st lever are optimized to induce the maximum magnification ratio using Taguchi method.

  • PDF

Three dimensional finite element analysis of continuous and segmented arches with use of orthodontic miniscrews (교정용 미니스크류를 이용한 연속호선과 분절호선의 유한요소분석)

  • Lee, Eon-Hwa;Yu, Hyung-Seog;Lee, Kee-Joon;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.41 no.4
    • /
    • pp.237-254
    • /
    • 2011
  • Objective: The purpose of this study was to compare the displacement patterns shown by finite element analysis when the maxillary anterior segment was retracted from different orthodontic miniscrew positions and different lengths of lever arms in lingual continuous and segmented arch techniques. Methods: A three dimensional model was produced, the translation of teeth in both models was measured and individual displacement was calculated. Results: When traction was carried out from miniscrews in the palatal slope, lingual tipping of crowns and extrusion of the maxillary anterior segment were found in both continuous and segmented arches as the lever arms were made shorter. With miniscrews in the midpalatal suture area, the displacement patterns were similar to the palatal slope, but bodily movement of the upper incisors was observed in both continuous and segmented arches with the lever arm at 20 mm. When lever arms were longer, there was less extrusion of the incisors and more buccal displacement of the canines. Such displacement was shown less in the continuous arch than the segmented arch. The second premolar showed crown mesial tipping and intrusion, and the molars showed distal tipping in the continuous arch. The posterior segment was displaced three dimensionally in the segmented arch, but the amount of displacement was less than the continuous arch. Conclusions: It is recommended that lever arms of 20 mm in length be used for bodily movement of the anterior segment. Use of continuous or segmented arches affect the displacement patterns and induce differences in the amount of displacement.