• Title/Summary/Keyword: Level-Pool Method

Search Result 49, Processing Time 0.029 seconds

Research on the development of demand for medical and bio technology using big data (빅데이터 활용 의학·바이오 부문 사업화 가능 기술 연구)

  • Lee, Bongmun.;Nam, Gayoung;Kang, Byeong Chul;Kim, CheeYong
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.2
    • /
    • pp.345-352
    • /
    • 2022
  • Conducting AI-based fusion business due to the increment of ICT fusion medical device has been expanded. In addition, AI-based medical devices help change existing medical system on treatment into the paradigm of customized treatment such as preliminary diagnosis and prevention. It will be generally promoted to the change of medical device industry. Although the current demand forecasting of medical biotechnology commercialization is based on the method of Delphi and AHP, there is a problem that it is difficult to have a generalization due to fluctuation results according to a pool of participants. Therefore, the purpose of the paper is to predict demand forecasting for identifying promising technology based on building up big data in medical biotechnology. The development method is to employ candidate technologies of keywords extracted from SCOPUS and to use word2vec for drawing analysis indicator, technological distance similarity, and recommended technological similarity of top-level items in order to achieve a reasonable result. In addition, the method builds up academic big data for 5 years (2016-2020) in order to commercialize technology excavation on demand perspective. Lastly, the paper employs global data studies in order to develop domestic and international demand for technology excavation in the medical biotechnology field.

The Study on the Ferrokinetics and Acquired Immunity in Repeated Hookworm Infections (구충성빈혈(鉤蟲性貧血)에 관(關)한 연구(硏究))

  • Lee, Mun-Ho;Lee, Pyl-Ung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.1 no.2
    • /
    • pp.61-74
    • /
    • 1967
  • In order to confirm whether acquired immunity or resistance can be developed by the repeated hookworm infections, the 150 mature actively moving filariform ancylostoma duodenale larvae obtained from the severe hookworm anemia patients were orally given to 8 healthy volunteers in three divided doses, 50 in each, at 5 day interval. Also the hematological changes as well as several ferrokinetics using $^{59}Fe$ were done and were compared with 10 controls. The clinical symptoms and signs were checked every day for the first 3 weeks and then twice weekly until the end of the experiment. The appearance of the ova in the stool was examined by the formalin ether method and the ova was counted by the Stoll's method. The following laboratory tests were done: 1) Red blood cell count, venous blood hematocrit(micromethod), hemoglobin count (cyanomethemoglobin method) were checked every 5 to 7 day interval. 2) Plasma iron concentration (Barkan's modified method) was determined every 2 to 3 week interval. 3) Radioisotope studies: a) Ferrokinetics: Huff et al and Bothwell's method were applied. Erythropoietic Index (% of normal)=$\frac{Subject's\;turnover/100ml\;whole\;blood{\times}100}{Average\;normal\;turnover/100ml\;whole\;blood}$ of the gastrointestinal absorption of iron: Radioiron($^{59}Fe$) balance b) Quantitative measurement method was applied. c) Determination of the plasma erythropoietin activity: Fried's method was applied. Following were the results: 1) The serum iron level was lower. The red cell volume was decreased, but with relative increase of plasma volume. 2) The plasma iron disappearance time was accelerated and the plasma iron turnover rate was decreased. The red cell iron turnover rate was markedly increased, while all of the red cell iron concentration, circulating red cell iron. plasma iron pool were decreased. The daily iron pool turnover and red cell renewal rate were increased. 3) The erythropoietic index, erythropoietin activity and intestinal absorption of iron($^{59}Fe$) were markedly increased. 4) The infectivity was $9.8{\pm}1.31%$ which was lower than that observed in the single infection. 5) From these observations, it is concluded that the hookworm anemia is essentially iron deficieny in its origin and some immunity acquisition is possible with repeated infections.

  • PDF

Determination of trace bromate in various water samples by direct-injection ion chromatography and UV/Visible detection using post-column reaction with triiodide

  • Kim, Jungrae;Sul, Hyewon;Song, Jung-Min;Kim, Geon-Yoon;Kang, Chang-Hee
    • Analytical Science and Technology
    • /
    • v.33 no.1
    • /
    • pp.42-48
    • /
    • 2020
  • Bromate is a disinfection by-product generated mainly from the oxidation of bromide during the ozonation and disinfection process in order to remove pathogenic microorganism of drinking water, and classified as a possible human carcinogen by International Agency for Research of Cancer (IARC) and World Health Organization (WHO). For the purpose of determining the trace level concentration of bromate, several sensitive techniques are applied mostly based on suppressed conductivity detection and UV/Visible detection after postcolumn reaction (PCR). In this study, the suppressed conductivity detection method and the PCR-UV/Visible detection method through the triiodide reaction were compared to analyze the trace bromate in water samples and estimated for the availability of these analytical methods. In addtion, the state-of-the-art techniques was applied for the determination of trace level bromate in various water matrices, i.e., soft drinking water, hard drinking water, mineral water, swimming pool water, and raw water. In comparison of two analytical methods, it was found that the conductivity detection had the suitable advantage to simultaneously analyze bromate and inorganic anions, however, the bromate might not be precisely quantified due to the matrix effect especially by chloride ion. On the other hand, the trace bromate was analyzed effectively by the method of PCR-UV/Visible detection through triiodide reaction to satisfactorily minimize the matrix interference of chloride ion in various water samples, showing the good linearity and reproducibility. Furthermore, the method detection limit (MDL) and recovery were 0.161 ㎍/L and 101.0-108.1 %, respectively, with a better availability compared to conductivity detection.

EXPERIMENTAL STUDY ON MEASUREMENT OF EMISSIVITY FOR ANALYSIS OF SNU-RCCS

  • CHO YUN-JE;KIM MOON OH;PARK GOON-CHERL
    • Nuclear Engineering and Technology
    • /
    • v.38 no.1
    • /
    • pp.99-108
    • /
    • 2006
  • SNU-RCCS is a water pool type RCCS (Reactor Cavity Cooling System) developed for VHTR (Very High Temperature Reactor) application by SNU (Seoul National University). Since radiation heat transfer is the major process of passive heat removal in a RCCS, it is important to determine the precise emissivity of the reactor vessel. Review studies have used a constant emissivity in the passive heat removal analysis, even though the emissivity depends on many factors such as temperature, surface roughness, oxidation level, wavelength, direction, atmosphere conditions, etc. Therefore, information on the emissivity of a given material in a real RCCS is essential in order to properly analyze the radiation heat transfer in a VHTR. The objectives of this study are to develop a method for compensation of the factors affecting the emissivity measurement using an infrared thermometer and to estimate the true emissivity from the measured emissivity via the developed method, especially in the SNU-RCCS environment. From this viewpoint, we investigated factors such as the attenuation effect of the window, filling gas, and the effect of background radiation on the emissivity measurements. The emissivity of the vessel surface of the SNU-RCCS facility was then measured using a sight tube. The background radiation was subsequently removed from the measured emissivity by solving a simultaneous equation. Finally, the calculated emissivity was compared with the measured emissivity in a separate emissivity measurement device, yielding good agreement with the emissivity increase with vessel temperature in a range of 0.82 to 0.88.

Introducing an Online Measurement System Using Item Response Theory and Computer Adaptive Testing Methods for Measuring the Physical Activity of Community-Dwelling Frail Older Adults

  • Choi, Bong-sam
    • Physical Therapy Korea
    • /
    • v.26 no.3
    • /
    • pp.106-114
    • /
    • 2019
  • Background: It is difficult to assess whether community-dwelling frail older adults may remain pre-frail status or improve into a robust state without being directly checked by health care professionals. The health information perceived by older adults is considered to be one of best sources of potential concerns in older adult population. An online measurement system combined with item response theory (IRT) and computer adaptive testing (CAT) methods is likely to become a realistic approach to remotely monitor physical activity status of frail older adults. Objects: This article suggests an approach to provide a precise and efficient means of measuring physical activity levels of community-dwelling frail older adults. Methods: Article reviews were reviewed and summarized. Results: In comparison to the classical test theory (CTT), the IRT method is empirically aimed to focus on the psychometric properties of individual test items in lieu of the test as a whole. These properties allow creating a large item pool that can capture the broad range of physical activity levels. The CAT method administers test items by an algorithm that select items matched to the physical activity levels of the older adults. Conclusion: An online measurement system combined with these two methods would allow adequate physical activity measurement that may be useful to remotely monitor the activity level of community-dwelling frail older adults.

Effect of Change of Reactor Coolant Injection Method on Risk at Loss of Coolant Accident due to Beam Tube Rupture (빔튜브파단 냉각재상실사고시 원자로냉각수 보충방법 변경이 리스크에 미치는 영향)

  • Lee, Yoon-Hwan;Lee, Byeonghee;Jang, Seung-Cheol
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.4
    • /
    • pp.129-138
    • /
    • 2022
  • A new method for injecting cooling water into the Korean research reactor (KRR) in the event of beam tube rupture is proposed in this paper. Moreover, the research evaluates the risk to the reactor core in terms of core damage frequency (CDF). The proposed method maintains the cooling water in the chimney at a certain level in the tank to prevent nuclear fuel damage solely by gravitational coolant feeding from the emergency water supply system (EWSS). This technique does not require sump recirculation operations described in the current procedure for resolving beam tube accidents. The reduction in the risk to the core in the event of beam tube rupture that can be achieved by the proposed change in the cooling water injection design is quantified as follows. 1) The total CDF of the KRR for the proposed design change is approximately 4.17E-06/yr, which is 8.4% lower than the CDF of the current design (4.55E-06/yr). 2) The CDF for beam tube rupture is 7.10E-08/yr, which represents an 84.1% decrease compared with that of the current design (4.49E-07/yr). In addition to this quantitative reduction in risk, the modified cooling water injection design maintains a supply of pure coolant to the EWSS tank. This means that the reactor does not require decontamination after an accident. Thermal hydraulic analysis proves that the water level in the reactor pool does not cause damage to the nuclear fuel cladding after beam tube rupture. This is because the amount of water in the chimney can be regulated by the EWSS function. The EWSS supplies emergency water to the reactor core to compensate for the evaporation of coolant in the core, thus allowing water to cover the fuel assemblies in the reactor core over a sufficient amount of time.

A Study on the Probability of BLEVE of Above-ground LP Gas Storage Tanks Exposed to External Fire (지상식 LPG 저장탱크의 외부화재에 의한 BLEVE 가능성 해석)

  • Lee Seung-Lim;Lee Young-Soon
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.1 s.18
    • /
    • pp.19-23
    • /
    • 2003
  • The purpose of this thesis is to investigate the BLEVE probability of LP gas storage tanks which are relatively more dangerous, by the deductive calculating method using the results of Birk's pilot tank test and the required heat capacity of BLEVE. The result that BLEVEs can occur in only above 43.68 percent of liquid filling level under $600^{\circ}C$ of tank pate temperature and $53^{\circ}C$ of inner liquid temperature, was obtained and will be useful for preventing the BLEVE of LP gas storage tanks in fire sites. In addition, this research showed conditions of external leak and fire causing BLEVE, based on 15ton capacity of LP gas tank which has the same specifications as those in Puchon LP gas filling station accident. The result of the calculation is that the minimum pool fire conditions of BLEVE are above 7.2mm equivalent diameter under a liquid release condition and above 17.6mm equivalent diameter under a two-phase release condition. In the end, the result of calculating the pool size corresponding the above conditions using EFFECTS version 2.1, concludes that a minimum of 3.3 meters of diameter and 10.4 meters of height should be needed for BLEVE outbreak.

  • PDF

A Case-Based Reasoning Method Improving Real-Time Computational Performances: Application to Diagnose for Heart Disease (대용량 데이터를 위한 사례기반 추론기법의 실시간 처리속도 개선방안에 대한 연구: 심장병 예측을 중심으로)

  • Park, Yoon-Joo
    • Information Systems Review
    • /
    • v.16 no.1
    • /
    • pp.37-50
    • /
    • 2014
  • Conventional case-based reasoning (CBR) does not perform efficiently for high volume dataset because of case-retrieval time. In order to overcome this problem, some previous researches suggest clustering a case-base into several small groups, and retrieve neighbors within a corresponding group to a target case. However, this approach generally produces less accurate predictive performances than the conventional CBR. This paper suggests a new hybrid case-based reasoning method which dynamically composing a searching pool for each target case. This method is applied to diagnose for the heart disease dataset. The results show that the suggested hybrid method produces statistically the same level of predictive performances with using significantly less computational cost than the CBR method and also outperforms the basic clustering-CBR (C-CBR) method.

Quantitation of Formate in Plants and Its Enhancement in Response to Environmental Stresses

  • Kim, Jae-Kwang;Cho, Myoung-Rae;Baek, Hyung-Jin;Ryu, Tae-Hun;Kim, Jung-Bong;Kim, Jun-Heong;Kim, Myong-Jo;Yu, Chang-Yeon;Fukusaki, Ei-Ichiro;Kobayashi, Akio
    • Journal of Applied Biological Chemistry
    • /
    • v.50 no.4
    • /
    • pp.211-214
    • /
    • 2007
  • A solid-phase microextraction and gas chromatography-mass spectrometry utilizing $^{13}C$-formate as an internal standard for the determination of formate was proved to be applicable as a reliable quantitative method in several plants. We were the first to discover that trees contain larger pool sizes of formate than herbs. Our data also showed that the formate level of the leaves increased after the methanol-spraying, suggesting that methanol oxidation could convert formaldehyde into formate. In addition, drought and chilling led to the increase of endogenous formate in Arabidospsis thaliana. These results confirmed that formate is a universal stress signal in plants.

A multi-scale analysis of the interdecadal change in the Madden-Julian Oscillation (MJO의 다중스케일 분석을 통한 수십년 변동성)

  • Lee, Sang-Heon;Seo, Kyong-Hwan
    • Atmosphere
    • /
    • v.21 no.2
    • /
    • pp.143-149
    • /
    • 2011
  • A new multi-timescale analysis method, Ensemble Empirical Mode Decomposition (EEMD), is used to diagnose the variation of the MJO activity determined by 850hPa and 200hPa zonal winds from the National Centers for Environmental Prediction/National Center for Atmospheric Research (NCEP/NCAR) Reanalysis data for the 56-yr period from 1950 to 2005. The results show that MJO activity can be decomposed into 9 quasi-periodic oscillations and a trend. With each level of contribution of the quasi-periodic oscillation discussed, the bi-seasonal oscillation, the interannual oscillation and the trend of the MJO activity are the most prominent features. The trend increases almost linearly, so that prior to around 1978 the activity of the MJO is lower than that during the latter part. This may be related to the tropical sea surface temperature(SST). It is speculated that the interdecadal change in the MJO activity appeared in around 1978 is related to the warmer SST in the equatorial warm pool, especially over the Indian Ocean.