• Title/Summary/Keyword: Level of Fouling

Search Result 44, Processing Time 0.023 seconds

Effects of Biomass Concentration and Sludge Loading Rate on Bioactivity and Membrane Fouling in a Submerged Membrane Bioreactor System (침지형 분리막 생물반응기에서 미생물 농도와 슬러지 부하에 따른 미생물 활성 변화와 막오염 특성 연구)

  • Tak Tae-Moon;Bae Tae-Hyun;Jang Gyoung-Gug
    • Membrane Journal
    • /
    • v.14 no.4
    • /
    • pp.289-297
    • /
    • 2004
  • In this study, membranes were coupled to a sequencing batch reactor for simultaneous removal of organic matter and nitrogen, and the influences of MLSS (mixed liquor suspended solid) concentration and the sludge loading rate on membrane fouling and bioactivity were investigated. The amount of membrane fouling slightly increased with MLSS concentration at both non-aeration and aeration conditions, but effect of MLSS concentration was more significant at aeration condition. Although the effect of MLSS concentration on membrane fouling was found to be insignificant at low concentration level, extremely low sludge loading, which were generated by the maintenance of large amount of biomass in the reactor, caused severe membrane fouling, and air scouring effect decreased significantly in this condition. Specific bioactivity was constantly reduced as sludge loading rate decreased. In spite of high MLSS concentration over 17,000 mg/L, the activity of the reactor decreased at extremely low sludge loading rate presumably due to the lower oxygen transfer and the competition of biomass to deficient substrate.

A Study on Diagnosing Fouling of Heat Exchangers of a Hybrid Heat Pump (하이브리드 열펌프 열교환기 오염 진단 연구)

  • Shin, Younggy
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.5
    • /
    • pp.240-246
    • /
    • 2014
  • A fault detector was developed for heat exchangers of a hybrid heat pump (HP) for household. The proposed detector can be applied directly to raw operating data. It is to monitor a tracking error between a measured saturation temperature and its state observer. The observer was estimated from a state-space model simulating dynamics of a heat exchanger. The real hybrid HP was substituted with a dynamic simulator that implemented two-phased heat transfer and was validated by experimental data. And artificial fault data were generated using the simulator. Diagnosing the data showed the following. The residual calculated from the state observer error shows a relatively robust consistency with respect fouling level. The fault detector is practically useful because it detects a threshold fouling beyond which the performance starts to deteriorate significantly.

Removal of Ammonia in Aquaculture Wastewater by Electrolysis with Switching Poles (극전환 전해 반응기를 이용한 양식 폐수 내 암모니아 제거)

  • Kang, Ki Moon;Kim, A Ram;Won, Yong-Sun;Lee, Jea-Keun;Lim, Jun-Heok
    • Clean Technology
    • /
    • v.21 no.1
    • /
    • pp.45-52
    • /
    • 2015
  • We have introduced switching poles in the conventional electrolysis for the removal of ammonia in aquaculture wastewater to prevent the fouling on the electrode surface by the deposition of insoluble metallic compounds. We have also tried to locate the optimal period of switching poles considering the effect of the current loss during switching poles on the free chlorine generation. First, we have observed the decrease of free chlorine generation with the decrease of the period of switching poles due to the expected current loss, and this would lead to the decrease of ammonia removal efficiency. Meanwhile, the measurement of calcium and magnesium concentration in wastewater vs. the period of switching poles have demonstrated that a properly low level of fouling on the electrode surface could be retained with a period of switching poles of less than 60 sec by the decomposition of metallic compounds during switching poles. In a summary, we have optimized the period of switching poles to gain a high level of free chlorine generation and a high level of fouling prevention on the electrode at the same time.

Separation of Antibiotics-Producing Mycelia by Cross-Flow Filteration (Cross-Flow Filtration에 의한 항생물질 생산 균사체의 분리)

  • 정상철;윤종원
    • KSBB Journal
    • /
    • v.4 no.2
    • /
    • pp.177-184
    • /
    • 1989
  • In separating mycelia from antibiotic fermentation broths, high permeate flux was obtained by cross-flow filtration using modified regenerated cellulose membrane. The flux was increased most effectively by increasing the flow rate. There existed a critical mycelium density (about 20% PMV) at which the highest flux was observed. In a batchwise concentration of the fermentation broth, the system suffered from a severe fouling problem, which was relieved drastically by applying diafiltration technique, although it increased the permeate volume. A combined concentration/diafiltration process was ideal in keeping relatively high flux together with a high product recovery yield. The best result was obtained by starting diafiltration after concentrating the broth to 20% PMV. By doing so, a 98% product recovery yield was achieved in the shortest time while keeping the permeate volume at a minimum level.

  • PDF

Pre-deposition of iron-based adsorbents on the removal of humic acid using ultrafiltration and membrane fouling

  • Tian, Hailong;Sun, Lihua;Duan, Xi;Chen, Xueru;Yu, Tianmin;Feng, Cuimin
    • Membrane and Water Treatment
    • /
    • v.9 no.6
    • /
    • pp.473-480
    • /
    • 2018
  • The effect of three iron-based adsorbents pre-depositing on ultrafiltration membrane for humic acid (HA) removal and membrane fouling was investigated. The result showed that pre-depositing adsorbents on membrane could not only reduce membrane fouling but also enhance HA removal. The flux was related to the adsorbent dosage and the optimal dosage for pre-deposition was $35.0g/m^2$. The dissolved organic carbon (DOC) removal of HA was 38.3%, 67.3% and 41.1% respectively when pre-deposited $35.0g/m^2$ $FeO_xH_y$, $MnFe_2O_4$ and $Fe_3O_4$ on membrane. Different adsorption effect of adsorbents on HA contributed to increasing of the flux at different level. Zeta potential of three adsorbents all decreased after adsorbed HA. The adsorption capacity of the three adsorbents was $FeO_xH_y$ > $MnFe_2O_4$ > $Fe_3O_4$. Atomic Force Microscopy (AFM) measurement showed the thickness of pre-deposition layers formed by different adsorbents was different. The scanning electron microscope (SEM) detection showed the morphology and compactness of pre-deposition layers formed by different adsorbents was different.

Study on the Biofouling Management of International Ships Entering South Korea (국내입항 국제운항선의 선체부착생물 관리에 대한 연구)

  • Park, JeongKyeong;Hoe, ChulHoi;Kim, HanPil;Cho, YuKyeong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.1
    • /
    • pp.10-18
    • /
    • 2022
  • With the increase in world trade through ships, the destruction of the marine ecosystem and socioeconomic damage due to invasive alien species (IAS) are continuously increasing. In particular, marine organisms attached on the hull surface and niche area increase the friction resistance of ships as well as the invasion of non-indigenous species, and causes a decrease in operational efficiency and an increase in GHG (Green House Gas) emissions. The International Maritime Organization (IMO) has recently begun revising guidelines for the control and management of ship's biofouling, and New Zealand and California in the United States are already regulating biofouling management under their own laws. This study investigated the management status of the submerged surface of ships and marine organisms attachments on five international ships entering South Korea, and analyzed species group and coverage (%) of biofouling communities to evaluate the LoF (Level of Fouling) rank. Macroflouling was observed on all ships surveyed, and specially, the adhesion of macro organisms in niche areas such as bow thruster, bilge keels and sea-chest gratings appeared to be at a serious level. This study proposed the management direction our country should take with regard to ship's biofouling and the improvement measures for evaluation of LoF rank and inspection methods of hull and niche ares.

Biofouling and Microbial Induced Corrosion -A Case Study

  • Mohammed, R.A.;Helal, A.M.;Sabah, N.
    • Corrosion Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.27-34
    • /
    • 2008
  • In industrial and fluid handling systems, frequently the protective film forming materials suffer from severe corrosion due to microbial effects. As an example, various micro-organisms, including bacteria, exist in seawater normally fed to power and desalination plants. Unless seawater intakes are properly disinfected to control these microbial organisms, biological fouling and microbial induced corrosion (MIC) will be developed. This problem could destroy metallic alloys used for plant construction. Seawater intakes of cogeneration plants are usually disinfected by chlorine gas or sodium hypochlorite solution. The dose of disinfectant is designed according to the level of contamination of the open seawater in the vicinity of the plant intake. Higher temperature levels, lower pH, reduced flow velocity and oxidation potential play an important role in the enhancement of microbial induced corrosion and bio-fouling. This paper describes, in brief, the different types of bacteria, mechanisms of microbiological induced corrosion, susceptibility of different metal alloys to MIC and possible solutions for mitigating this problem in industry. A case study is presented for the power plant steam condenser at Al-Taweelah B-station in Abu Dhabi. The study demonstrates resistance of Titanium tubes to MIC.

A multi-level approach for the optimization of an ultrafiltration plant processing surface water

  • Zondervan, E.;Roffel, B.
    • Membrane and Water Treatment
    • /
    • v.1 no.1
    • /
    • pp.61-74
    • /
    • 2010
  • This paper will integrate models at different levels (from filtration, backwashing to chemical cleaning and membrane lifetime) that can be used to minimize overall operating costs of a dead-end ultra filtration process that is used for the purification of surface water. Integration of the models leads to a multi-level optimization problem (at different levels different objectives should be reached). This problem is solved as a MINLP. Systematic modelling and optimization of membrane systems is not extensively discussed in the scientific literature. In this paper the first steps are taken in the formulation of proper models and the use of systems engineering tools to come to real optimal operating conditions. The optimized variables are used to calculate fouling profiles which can subsequently be used as inputs for a control system that actually enforces the profiles to a real pilot plant.

New Gain Function Based on Attenuation Characteristics of Ballast Track for GPR Analysis (GPR 분석을 위한 자갈궤도 자갈의 감쇄특성을 이용한 이득함수 개발)

  • Shin, Jihoon;Choi, Yeongtae;Jang, SeungYup
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.4
    • /
    • pp.13-21
    • /
    • 2017
  • Ballasted track has been used as track system for more than 100 years. Ballasted track has advantages of low construction cost, flexible maintenance, low noise and vibration, and so on. However, ballasted track leads to continuous settlement which causes maintenance. Recently, increase in speed, traffic volume, and weight of train requires more frequent maintenance. Fouling, well-known phenomenon of accumulation of fine materials due to intrusion of subgrade and breakage of ballast materials, expedites the settlement (i.e., irregular settlement) of track. Ground Penetrating Radar (GPR) can be one of non-destructive tools that can evaluate fouling level of ballast. In this paper, a gain function based on the attenuation characteristics of ballast material is suggested in conjunction with Hilbert transform. Lab box tests and full-scale tests indicate that the suggested method reasonably classifies clean, fouled layers, and subgrade. However, additional study to eliminate effect of sleeper and to include the scattering features of the electromagnetic wave in ballast voids should be required in order to enhance the accuracy.

Analysis of Hydrophobic Membrane Fouling on the COD Loading Rates at the State of Passive Adsorption in Membrane Bioreactor (생물학적 막분리 공정에서 수동흡착 상태에서의 유기물 유입 부하에 따른 소수성 막의 오염도 분석)

  • Park, Tae-Young;Choi, Changkyoo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.3
    • /
    • pp.152-158
    • /
    • 2015
  • This paper investigated the membrane fouling potential at the state of passive adsorption which is no permeation with the test modules on COD (Chemical oxygen demand) loading rates, examined the recovery rate and resistance on membrane fouling by three cleaning manners of hydrophobic membrane in a bioreactor. The results showed that high COD loading led to the increase of extra-cellular polymeric substances and filtration resistance. The permeability resistance from 1st day to 63rd day was getting increased, however, the value of permeability resistance after 63th day during the operation period was almost same level at three COD loading rates, it was due that the biomass adhesion on membrane surface at the state of passive adsorption reached to the critical state. Also, the final recovery rates after three cleaning manners were 78%, 72% and 69% at the COD loading concentrations of 250 mg/L, 500 mg/L and 750 mg/L respectively, and then recovery rate by physical cleaning at Run 2 and Run 3 was decreased after 40th day, it proved that biomass cake, which is not easily removed, was formed on the membrane surface because of high COD loading rate and EPS concentration.