• 제목/요약/키워드: Level measurement

검색결과 4,899건 처리시간 0.036초

경지 균평 작업을 위한 자동 표고 측정에 관한 연구 (A Study on the Automatic Level Measurement for Land Leveling)

  • 김종안;김수현;곽윤근
    • Journal of Biosystems Engineering
    • /
    • 제22권3호
    • /
    • pp.269-278
    • /
    • 1997
  • An automatic level measurement system was developed to level the land fer direct seeding of rice. A laser transmitter/receiver set was used to measure land-level. The inclination error occurred in level measurement on irregular land surface could be compensated by attaching rotating mass. The level measuring experiments were performed on three kinds of different shapes(step, random, sine). This system could accurately measure step level of which amplitude was 40mm in 0.5s, random level change within $\pm$ 5mm maximum measurement error, and sine level change of which spatial frequency was 0.5m-1. To verify performance of the inclination error compensation system, frequency transfer function(acceleration input vs. inclination error) was computed by spectral analysis. The inclination error was decreased about 20㏈ by error compensation system.

  • PDF

RADAR level measurement in Joule heated ceramic melter: A novel technique

  • Suneel, G.;Mahashabde, Mukesh;Borkotoky, Ritusmita;Sharma, Nitin Kumar;Pradeep, M.P.;Gayen, J.K.;Pimparkar, H.R.;Ravi, K.V.
    • Nuclear Engineering and Technology
    • /
    • 제53권4호
    • /
    • pp.1176-1180
    • /
    • 2021
  • The current study relates to RADAR (RAdio Detection and Ranging) application for level measurement of vitrified radioactive liquid nuclear waste. The vitrification of radioactive liquid waste is carried out in special equipment called 'Melters'. The study is directed towards the design and frequency modulation used in the level measurement of vitrified waste. More specifically, the RADAR design and frequency used for level measurement in a melter. This level measurement technique can also be used for dynamic vitrification process and can be used to measure the level variations without using any external medium/material and using only electromagnetic waves. Also, this technique is durable and accurate even under the high radioactive environment present inside the melter.

Liquid level measurement system using capacitive sensor and optical sensor

  • Shim, Joonhwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제37권7호
    • /
    • pp.778-783
    • /
    • 2013
  • Measurement of liquid level in storage and processing vessels, tanks, wells, reservoirs and hoppers is commonly needed. The several different ways to measure the liquid level of oil or water tank have been provided such as an electrostatic capacity, a supersonic waves and an optical science etc. In the study, we have constructed the stable and efficient measurement system to measure the level of liquid at real-time and to get accurate measurement of the maximum and minimum level of the tank. For this purpose, we suggest double sensing methods by adopting both capacitive and optical sensing. The experimental results, presented in this paper, illustrate the effectiveness of the proposed method under different sensing methods.

홍수 위험도 척도 및 예측모형 연구 (Study on Measurement of Flood Risk and Forecasting Model)

  • 권세혁;오현승
    • 산업경영시스템학회지
    • /
    • 제38권1호
    • /
    • pp.118-123
    • /
    • 2015
  • There have been various studies on measurements of flood risk and forecasting models. For river and dam region, PDF and FVI has been proposed for measurement of flood risk and regression models have been applied for forecasting model. For Bo region unlikely river or dam region, flood risk would unexpectedly increase due to outgoing water to keep water amount under the designated risk level even the drain system could hardly manage the water amount. GFI and general linear model was proposed for flood risk measurement and forecasting model. In this paper, FVI with the consideration of duration on GFI was proposed for flood risk measurement at Bo region. General linear model was applied to the empirical data from Bo region of Nadong river to derive the forecasting model of FVI at three different values of Base High Level, 2m, 2.5m and 3m. The significant predictor variables on the target variable, FVI were as follows: ground water level based on sea level with negative effect, difference between ground altitude of ground water and river level with negative effect, and difference between ground water level and river level after Bo water being filled with positive sign for quantitative variables. And for qualitative variable, effective soil depth and ground soil type were significant for FVI.

선박 방사소음의 측정방법 및 정확도 해석 (Ship Radiated Noise Measurement Methods and Accuracy Analysis)

  • 이필호;윤종락
    • 한국소음진동공학회논문집
    • /
    • 제15권6호
    • /
    • pp.738-748
    • /
    • 2005
  • The ship radiated noise level fluctuates by the difference of interference and reverberation according to measurement methods and environmental conditions. These phenomena cause error of the source level estimation even in the same environment conditions. This paper describes a quantitative analysis and a reduction method for an error value to the source level estimation in spatial and temporal interference environment. The design criteria of the radiated noise measurement array composed of omni-directional hydrophones and the source level accuracy in the deep water range are given. The source level accuracy in the shallow water range is also derived based on the statistical model of the multiple reflection paths. The results are verified using the water tank experiment and the sea trial.

자동 표고 측정 장치 개발에 관한 연구 (A Study on the Development of the Automatic Level Measurement System)

  • 김종안;김수현;곽윤근
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.756-760
    • /
    • 1997
  • In this research, the automatic level measurement system used in land leveling was developed. By using a laser transmitter and a receiver as measuring equipments, level was measured automatically. The driving part of this system was composed of stepping motor, timing belt and pulley. It drived the laser receiver to track laser beam generated form the laser transmitter. The level measuring experiments were performed about three level change shapes (step, random, sine). This system could measure step level change of which amplitude was 40mm in 0.5s, random level change within .+-. mm, maximum measurement error. In case of sine level change, experiment was executed with varying the spatial frequency of level change. As a result, this system was able to measure sine level change of which spatial frequency was 0.5m $^{-1}$ accurately.

  • PDF

농업저수지 자동 수위관측기 개발 - 저전력 원격제어 수위관측기 중심 - (Development of Automatic Water Level Measurement System for the Irrigation Reservoir - Study on Low Power and Remote Controlled Water Level Measurement System -)

  • 김진택;주욱종;최승철
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2003년도 학술발표논문집
    • /
    • pp.491-494
    • /
    • 2003
  • An Automatic Water Level Measurement System has been developed in this study. It has the characteristics that it use lower power and solar power and it has the ability of sending data and remote-controlled by wireless MODEM this system was set up in the experimental site and was tested. Also, the management system for the water level data has been developed and will be used by instruments administrating reservoirs.

  • PDF

실험실 실험을 통한 벽체 차음성능 측정의 신뢰성 향상을 위한 실험적 연구 (An Experimental Study to Improve Measurement Reliability for the Airborne Sound Insulation Performance by Laboratory Test)

  • 김항;박현구;구희모;김선우
    • 한국소음진동공학회논문집
    • /
    • 제24권1호
    • /
    • pp.35-44
    • /
    • 2014
  • Sound pressure levels in the receiving room while testing airborne sound insulation performance are varied by the measuring points. This may increase the measurement error, then decrease the measurement reliability. With this reason the research has carried out on the method to reduce deviations of sound pressure level in the ISO type rectangular laboratory focusing on the measurement of airborne sound insulation performance. Tests were made to see the effect of sound absorption in the receiving room, loudspeaker locations, microphones locations and flanking transmission path. Consequently, it was resulted that sound absorption in the receiving room and the loudspeaker location have influence on the sound level deviations especially in the low frequency. The microphone location was very important to get measurement reliability. The effective measuring point, which the sound level difference with average sound pressure level is within 2 dB, could yield most reliable average sound pressure level. Therefore it is necessary to find the effective measuring points in the receiving room. Flanking transmission path should be sealed using sound absorber or magnet etc. to prevent from lowering the sound insulation performance.

원격 측정 레벨계의 최소 탐지거리 성능 개선 방법 (A Method on the Improvement of the Minimum Detection Distance of the Remote Measurement Level Meter)

  • 박동근;이기준
    • 대한원격탐사학회지
    • /
    • 제34권3호
    • /
    • pp.535-543
    • /
    • 2018
  • 최근 레벨계는 산업현장의 안전 및 유지관리와 연관되어 넓은 측정범위가 요구되는 추세이다. 일반적으로 레벨계의 측정범위를 확보하기 위해 측정환경을 개선하여 잡음을 감소시키거나 신호처리를 통해 신호의 왜곡을 보상하게 된다. FMCW 레이다 레벨계의 잡음과 신호의 왜곡은 레벨계의 근거리 특성에 영향을 주어 최소탐지거리가 감소되는 결과를 갖게 한다. 본 논문에서는 레벨계의 근거리 영역의 잡음을 제거하기 위해 window 함수와 비트 스펙트럼의 특성을 고려한 Equalizer 필터를 적용하여 최소탐지거리 성능을 개선하며 탐지가 상대적으로 어려운 레벨계 근거리의 측정 신뢰도를 높이고 탐지영역내의 측정 범위를 향상 시키고자 한다.

Development of the Ultrasonic Method for Two-Phase Mixture Level Measurement

  • Lee, Dong-Won;No, Hee-Cheon;Song, Chul-Wha;Jeong, Moon-Ki
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1999년도 춘계학술발표회요약집
    • /
    • pp.124-124
    • /
    • 1999
  • An ultrasonic method is developed for the measurement of the two-phase mixture level in the reactor vessel or steam generator. The ultrasonic method is selected among the several non¬nuelear two-phase mixture level measurement methods through two steps of selection procedure. A commercial ultrasonic level measurement method is modified for application into the high temperature, pressure, and other conditions. The calculation method of the ultrasonic velocity is modified to consider the medium as the homogeneous mixture of air and steam. and to be applied into the high temperature and pressure conditions. The cross-correlation technique is adopted as a detection method to reduce the effects of the attenuation and the dif.JUsed reflection caused by suface fluctuation. The waveguides are developed to reduce the loss of echo and to remove the effects of obstructs. The present experimental study shows that the developed ultrasonic method measures the two-phase mixture level more accurately than the conventional methods do.

  • PDF