• Title/Summary/Keyword: Level Plate

Search Result 935, Processing Time 0.03 seconds

Effect of plate size on meal energy intake in normal weight women

  • Ayaz, Aylin;Akyol, Asli;Cetin, Cansu;Besler, H. Tanju
    • Nutrition Research and Practice
    • /
    • v.10 no.5
    • /
    • pp.524-529
    • /
    • 2016
  • BACKGROUND/OBJECTIVES: Use of smaller plates to control food intake is a commonly recommended strategy for restricting energy intake, despite conflicting results. Therefore, the aim of this study was to examine whether or not three different sizes of plates influence energy intake during a multi-itemed buffet meal in normal weight women. SUBJECTS/METHODS: This was a cross-over study conducted on 37 female participants aged 19-25 years with normal BMI levels. Participants were recruited from Hacettepe University and the surrounding community. On experimental days, participants ate a standard breakfast and were then randomly assigned to eat lunch using a small (19 cm), medium (23 cm), or large (28 cm) diameter plate. Visual analogue scale (VAS) scores on sensory and satiety outcomes were measured for all meals. Energy and macronutrient intakes during lunch were recorded. RESULTS: There was no evidence that use of a smaller plate size reduced energy or specific macronutrient intake during the free choice lunch meal. Multiple visits to the serving table were not associated with energy or macronutrient intake. Plate size did not affect VAS scores during the test days. CONCLUSIONS: Plate size did not influence energy intake, meal composition, or palatability in normal weight women during a multi-itemed open buffet lunch. Studies in natural settings at the population level are needed to clarify current outcomes.

Ultimate Analysis of RC Beam with Unbonded Prestressing CFRP Plate (비부착 CFRP 판으로 긴장된 RC 보의 극한해석)

  • Lee, Jae-Seok;Choi, Kyu-Chon;Park, Young-Ha
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.249-252
    • /
    • 2008
  • A study for the nonlinear analysis method of RC(Reinforced Concrete) beams with unbonded prestressing CFRP plate is presented. The cross-section of RC beam element is idealized as an assemblage of concrete and reinforcing steel fibers in order to account for varied material properties within the cross-section of the element. The unbonded CFRP plate is modeled as a series of the CFRP plate segments each of which is linked to the RC beam element, but slips without any resistance to simulate the unbonded behavior of the CFRP plate. The stress of each CFRP plate segment is redistributed iteratively using the force equilibrium relationship at each common node until it reaches at the same stress level. To evaluate the validity of the proposed analysis method, the results of ultimate analysis of the reinforced concrete beams with unbonded prestressing CFRP plates are compared with the experimental results obtained from other investigators. The proposed analysis method is found to predict ultimate behaviors of these beams fairly well.

  • PDF

Studies on Application of Starch Part I. Action of Amylase on Starch Agar-gel-plate (전분이용(澱粉利用)에 관한 연구(硏究)(제(第) 1 보(報)) Starch Agar-gel-plate를 이용(利用)한 Amylase 활성(活性) 측정법(測定法))

  • Yu, Ju-Hyun;Chu, Kyung-Hee;Hong, Yun-Myung;Arima, K.
    • Korean Journal of Food Science and Technology
    • /
    • v.2 no.1
    • /
    • pp.67-71
    • /
    • 1970
  • The amylase was0 incubated in a 9mm hole on the starch agar gel plate bored with a cork borer. When 0.1N-iodine solution sprayed on the plate, the formed uncolored zone were observed. An activity of amylase has been determined by measurement of diameter of the uncolored zone. We named this method 'cork borer method'. When amylase was incubated on the starch agar gel plate, the following points were obtained. 1) The optimum pH for the formation of the zone in case of amylases(Biotex, Spitase) which produced by Bacillus is neutrality and alkali, while that for Glucoamylase, Biodiase, and Mucorrennin which produced by Rhizopus and Mucor is from 5 to 7. 2) The diameter of the zone was increased by the incubation time and amylase activity. 3) The zone was easily formed at low level of starch concentration and was formed much bigger than at $50^{\circ}C\;than\;at\;10^{\circ}C$. From the above results, after malting the starch agar gel plate, keeping constant concentration of the starch, the measurement of amylase activity is in efficiency upon the constant reaction time and temperature.

  • PDF

Economical Analysis of Cervical Disc Disease by Anterior Inter-body Fusion Methods - Comparing of Bone Graft vs Plating - (경추간판 탈출 환자의 전방 고정술에 따른 경제적 분석 - 골 이식법과 금속판 고정 병행술의 비교 -)

  • Gill, Seung-Bae;Lee, Sang-Youl;Heo, Seung-Ho;Jang, Yeun-Gyu
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.2
    • /
    • pp.201-206
    • /
    • 2001
  • Objective : The purpose of this study was to assess the complications, duration of admission, cost effectiveness, radiologic stabilization of the anterior cervical bone fusion in the treatment of cervical disc disease with and without plating. Materials and Methods : Fifty-two surgically treated patients for cervical disc disease were reviewed. Group I consisted of consecutive treated patients with iliac auto-bone graft without instrumentation after anterior cervical discectomy. Group II consisted of consecutive treated patients with iliac autologous-bone graft with CASPER cervical plate fixations. Radiologic fusion was decided when loss of end plate boundary between graft bone and vertebral body and immobile, maintenance of the disc space were evident on simple dynamic plain films. The patients were discharged after the stabilization of cervical motion by films was of tained. These groups were analysed multiple variably with Mann-Whitney U-test. Results : Group I consisted of 18 patients, group II consisted of 34 patients. Mean age was $49.0{\pm}8.1years$, mean duration of admission was $17.27{\pm}10.51days$, mean costs for treatment was $1,970,000{\pm}475,000won$. In group I, mean age was 47.7(34-60) years, 16 patients had undergo on one-level operation, 2-patients had undergo on two-level operation, mean duration of admission was $28.7{\pm}10.4days$, mean costs for treatment was $2,194,473{\pm}561,639won$. The periods of stabilization was $6.6{\pm}3.36weeks$ on radiologic study. Mean periods of out patient follow up was 16.8(6-64) weeks after discharge. Mean period of radiologic follow up was 17.3(4-6) weeks after surgical operation. In group II, mean age was 49.7(37-62) years and 18 patients one-level operation, 14- patients had undergo on two-level operation and 2-patients three-level operation. Mean duration of admission was $11.24{\pm}3.29days$, mean costs for treatment was $1,850,823{\pm}389,372won$. The periods of stabilization was $5.88{\pm}7.07weeks$ on radiologic study. Mean period of out patients follow up was 16.7(4-60) weeks after discharge. Mean period of radiologic follow up was 12.4(3-52) weeks after surgical operation. The duration of admission showed statistical significance in Group II but other items showed no significant difference between two groups. Conclusions : The more economic, early life return and effective method of cervical disc disease in our series were evident in patients who had undergone, iliac bone graft and plate fixations after anterior discectomy.

  • PDF

LES of Turbulent Mixing of Non-Reactive Flow in Gas Generator (가스발생기 비-반응 유동의 난류 혼합에 대한 LES 해석)

  • Lee, Chang-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.12
    • /
    • pp.1171-1179
    • /
    • 2008
  • LES analysis was conducted with in-house CFD code to investigate the turbulence evolution and interaction due to turbulence ring and splash plate in the gas generator. The calculation results show that the installation of turbulence ring can introduce additional turbulences and significantly improve turbulent mixing in the downstream flow. However, the addition of splash plate in the downstream of TR(Turbulence Ring) brings totally different shape of perturbation energy and enstrophy distribution into turbulent mixing. This enhancement can be done by the formation of the intensively strong vorticity and mixing behind the plate. Pressure drop was found to be a reasonable level of about 1% or less of initial pressure in all calculation cases. Also, calculation results revealed that the variation of shape and intrusion length of TR did not greatly affect the characteristics of turbulent mixing in the chamber. Even though the effect of installation location of splash plate on the turbulent mixing was not investigated yet, calculation results conclude the addition of splash plate leads to the increase in turbulent mixing with an acceptable pressure drop.

Internal Fixation with a Locking T-Plate for Proximal Humeral Fractures in Patients Aged 65 Years and Older

  • Yum, Jae-Kwang;Seong, Min-Kyu;Hong, Chi-Woon
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.4
    • /
    • pp.217-221
    • /
    • 2017
  • Background: The purpose of this study was to evaluate the clinical and radiographic outcomes of internal fixation with locking T-plates for osteoporotic fractures of the proximal humerus in patients aged 65 years and older. Methods: From January 2007 through to December 2015, we recruited 47 patients aged 65 years and older with osteoporotic fractures of the proximal humerus. All fractures had been treated using open reduction and internal fixation with a locking T-plate. We classified the fractures in accordance to the Neer classification system; At the final follow-up, the indicators of clinical outcome-the range of motion of the shoulder (flexion, internal rotation, and external rotation) and the presence of postoperative complications-and the indicators of radiographic outcome-the time-to-union and the neck-shaft angle of the proximal humerus-were evaluated. The Paavolainen method was used to grade the level of radiological outcome in the patients. Results: The mean flexion was $155.0^{\circ}$ (range, $90^{\circ}-180^{\circ}$), the mean internal rotation was T8 (range, T6-L2), and the mean external rotation was $66.8^{\circ}$ (range, $30^{\circ}-80^{\circ}$). Postoperative complications, such as plate impingement, screw loosening, and varus malunion were observed in five patient. We found that all patients achieved bone union, and the mean time-to-union was 13.5 weeks of the treatment. The mean neck-shaft angle was $131.4^{\circ}$ at the 6-month follow-up. According to the Paavolainen method, "good" and "fair" radiographic results each accounted for 38 and 9 of the total patients, respectively. Conclusions: We concluded that locking T-plate fixation leads to satisfactory clinical and radiological outcomes in elderly patients with proximal humeral fractures by providing a larger surface area of contact with the fracture and a more rigid fixation.

Stress Analysis of the Cylinder Block and the Valve Plate of the Swash Plate Type Oil Hydraulic Piston Pump (사판식 유압 픽스톤 펌프의 실린더블록과 밸브 플레이트의 응력해석)

  • Kim J. H.;Cho I. S.;Baek I. H.;Jung Jae-Youn;Oh Suk-Hyung
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.255-260
    • /
    • 2004
  • Recently, the technologies related to the swash plate type oil hydraulic piston pump are requiring extreme technologies to overcome the limit of high efficiency in cope with high speed and pressure, and are devoted to compact the unit, to gain low noise level, and to adopt electronic technologies, and the question regarding to maximize the mechanical efficiency, that is, to minimize the torque loss by minimizing the leakage loss in the relative sliding region but these are in trade-off relation that tribological responding is very difficult. Cylinder block-valve pate in high speed relative sliding motion has the characteristics that should be extremely controlled for the optimization of these leakage loss and mechanical efficiency, and pressure resistance designing of them is important for high pressure performance. But, studies on the stress analysis of these parts have not been performed briskly, so in this paper the stress distribution and the region where the highest displacement appears are described through the static stress analysis using CATIA V5. Through the future studies on these theme, it has the purpose of finding the suitable materials for the other parts as well as cylinder block and valve plate, in cope with high pressure operation through the stress analysis with the most similar conditions for the practical operation.

  • PDF

Comparison of Buckling Check Formulas and Optimal Design (보강판의 좌굴 평가식에 따른 좌굴 강도 및 최적설계의 비교)

  • Jang, Beom-Seon;Cho, Ho-Young
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.5
    • /
    • pp.71-78
    • /
    • 2009
  • In ship design or offshore structure design, the evaluation of buckling strength (or ultimate strength) is critical to the determination of scantling of stiffened plates. For this reason, it is useful to study the effect of applying different formula or the relationship between stiffened plate with buckling utilization factor (UF). It can facilitate a designer to decide how much the scantling should be reinforced or how much can be reduced for an optimal design. This paper conducts a comparative study for three buckling check methods; DNV-Ship-Rule, DNV-RP-C201, DNV-PULS. The capacity curves and 2D contour plot for utilization factors versus bi-axial in-plane stresses are compared. The contour plots of DNV-Ship-Rule and DNV-PULS show smoothly increasing trends of UF as the applied in-plane stresses increase, however that of DNV-RP-C201 shows rapidly increasing trend as the applied stresses go beyond transverse buckling stress. A sensitivity analysis is performed to investigate the influence level of each parameter of a stiffened plate on UF. Resulting from the analysis, plate thickness is identified to be the most affective parameter to UF regardless of the buckling check methods. Based on the addressed study, optimal designs for bottom plate of 165 K tanker corresponding to three formulas are compared with each other. DNV-PULS yields 1 mm and 2 mm less thickness than DNV-Ship-Rule and DNV-RP-C201, respectively.

A study on improvement of 2. 3. 5-Triphenyl Tetrazolium Chloride(TTC) reduction test : disc plate method (2. 3. 5-Triphenyl Terazolium Chloride(TTC) 환원시험법의 개선에 관한 연구 : disc plate method)

  • 정동수;김동훈;이상목
    • Korean Journal of Veterinary Service
    • /
    • v.18 no.2
    • /
    • pp.163-176
    • /
    • 1995
  • Triphenyl Tetrazolium Chloride(TCC) reduction test is simple and sensitive to some residual antibiotics (especially to penicillin) in milk, but comparatively insensible to sulfo-namides. The volumn of sample is also large. Thus this study was undertaken to increase the detectable level of sulfonamides in raw milk. In this study, we used small transparent plastic hole and pulp disc instead of 10m1 test tube and made test medium in which was added 0.08%TTC, 0.3% agar, 10% skim milk, approximately $10^6$ CFU/ml streptococcus thermophilus and 5ppm Trimethoprim to enhance the sensitivity for sulfonamides The results of TCC reduction test by disc plate method were summarized as follows : 1. sensitivity to residual sulfonamides were much higher than official TCC reduction test. Detectable limites of sulfamethazine, sulfamerazine, sulfathiazole, sulfachloropy-ridazine, sulfadimethoxine, sulfamononethoxine, sulfadiazine and sulfaquinoxaline were 0.1-0.5ppm levels. 2. Detectable limites to some antibiotics were simillar or good than that of official method as 0.005-0.1ppm to three ${\beta}$ -lactams, 0.25-0.5ppm to one macrolide, 2-10ppm to three aminoglycosides, 0.2-0.5ppm to three tetracycline, 0.1-0.5ppm to chloramphenicol. 3. Only 0.1ml of milk was needed to test and the test medium could be stored appnoximatly 7days in the refrigerator. So test procedure was convenient than offcial method. 4. These results suggest that disc plate method is more useful to detect bacterial growth inhibition substances including sulfonamides in raw milk.

  • PDF

FE Analysis on the Design Safety of Inner Tank Bottom Plate in Terms of Cryogenic Temperature Loadings (초저온 하중을 고려한 내부탱크 바닥판의 설계 안정성에 관한 유한요소해석)

  • Kim Chung Kyun;Cho Seung Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.8 no.3 s.24
    • /
    • pp.8-15
    • /
    • 2004
  • This paper presents von Mises stress, deformation, and rotating distortion moment characteristics of inner tank bottom plate as a function of a cryogenic temperature difference along the radial distance from the center area to the corner one. The calculated results show that the filling level of LNG at the beginning of the cool-down process is very important for the design safety analysis of the inner tank. Obviously the thermal loading by a temperature difference between the LNG vapor gas of $-80^{\circ}C$ and a LNG temperature of $-162^{\circ}C$ affects to the thermal related characteristics of the bottom plates and annular one. From the computed results, the temperature difference by a vapor gas and liquid of LNG may lead to the thermal instability of the bottom plate. This phenomenon may cause the system failure of an inner tank.

  • PDF