• 제목/요약/키워드: Lens thickness

검색결과 187건 처리시간 0.025초

3 차원 입체요소를 사용한 사출성형품의 잔류응력 예측 및 후변형 해석 (Residual Stress Estimation and Deformation Analysis for Injection Molded Plastic Parts using Three-Dimensional Solid Elements)

  • 박근;안종호;임충혁
    • 대한기계학회논문집A
    • /
    • 제27권4호
    • /
    • pp.507-514
    • /
    • 2003
  • Most of CAE analyses for injection molding have been based on the Mele Shaw's approximation: two-dimensional flow analysis. in some cases, that approximation causes significant errors due to loss of the geometrical information as well as simplification of the flow characteristics in the thickness direction. Although injection molding analysis software using three-dimensional solid elements has been developed recently, such as Moldflow Flow3D, it does not contain a deformation analysis function yet. The present work covers three-dimensional deformation analysis or injection molded plastic parts using solid elements. A numerical scheme for deformation analysis has bun proposed from the results of injection molding analysis using Moldflow Flow3D. The accuracy of the proposed approach has been verified through a numerical analysis of rectangular plates with various thicknesses in comparison with the classical shell-based approach. In addition, the reliability of the approach has also been proved through an industrial example. an optical plastic lens, in comparison of real experiments.

테일러드 블랭크용 박판 강재의 레이저 용접성 (II) -이음 형상이 용접성에 미치는 영향- (Laser Weldability of Sheet Steels for Tailored Blank Manufacturing (II) -Effect of Joint Configuration-)

  • 김기철;이기호;이목영
    • Journal of Welding and Joining
    • /
    • 제16권2호
    • /
    • pp.100-110
    • /
    • 1998
  • In this paper, the laser weldability of thin gage steels for automobile application is discussed. Welding was carried out with a high power carbon dioxide laser system, and the laser energy was concentrated through a plano-convex lens. Test results showed that the joint gap in the butt welding proved to be one of the critical conditions for an acceptable weld. In the case where the ratio of the gap clearance to the material thickness was slightly bigger than optimal value, the weld strength was reduced showing weld metal fracture. It was possible to obtained a weld penetration ratio of 0.91 when the vertical offset ratio was controlled to be 0.4 or smaller. Results also demonstrated that the weld strength of the lap joint was influenced by travel speed. At the travel speeds lower than 37 mm/s, the weld strength indicated higher value than that of class A recommendation strength of a resistance spot weld based on the KS code. It was clear that the complicated effect of specimen alignment should be considered so as to make a sound weld with high integrity when the laser process was applied to the long weld line.

  • PDF

마이크로 광 조형에서 레이저 주사조건에 따른 광 경화성수지의 경화현상 (Photopolymer Solidification Phenomena Considering Laser Exposure Conditions in Micro-stereolithography Technology)

  • 이인환;조동우;이응숙
    • 한국정밀공학회지
    • /
    • 제21권3호
    • /
    • pp.171-179
    • /
    • 2004
  • Micro-stereolithography technology has made it possible to fabricate a freeform 3D microslructure. This technology is based on conventional stereolithography, in which a UV laser beam irradiates the open surface of a UV-curable liquid photopolymer, causing it to solidify. In micro-stereolithography, a laser beam of a few $\mu m$ diameter is used to solidify a very small area of the photopolymer. This is one of the key technological elements, and can be achieved by using a focusing lens. Thus, the solidification phenomena of the liquid photopolymer must be carefully investigated. In this study, the photopolymer solidification phenomena in response to variations in the scanning pitch of a focused laser beam was investigated experimentally. The effect of layer thickness on the solidification width and depth was also examined. These studies were conducted under the conditions of relatively lower laser power and relatively higher scanning speed. Moreover, the photopolymer solidification phenomena for the relatively higher laser power and lower scanning speed was investigated, too. In this case, comparing to the case of lower laser power and higher scanning speed, the photopolymer absorbed large amount of irradiation energy of the laser beam. These results were compared with those obtained from a photopolymer solidification model. From these results, a new laser-scanning scheme was proposed according to the shape of the 3D model. Samples by each method were fabricated successfully.

다층광학필름에서 마이크로패턴 삽입을 통한 색 조정 연구 (Color Adjustment Study by Micro-Pattern Embedding in Optical Multilayer Thin Film)

  • 김민;우주연;윤준호;황보창권;한창수
    • 한국정밀공학회지
    • /
    • 제33권5호
    • /
    • pp.409-417
    • /
    • 2016
  • It is well known that Morpho butterflies show distinctive, brilliant and iridescent colors and have micro-nano scale structures, instead of dyes and pigments, on their wings. This structural coloration is regarded as a novel technique to express color with a long lifetime, ease and precise tenability. Here, we studied optical multilayer thin films with thickness of several tens of nm ($TiO_2$ and $SiO_2$) and lens-shape micro-patterns. Fabrication and characterization of the multilayer stacking structure and the micro-pattern structure were performed and the films were analyzed via several optical measuring techniques. Finally, we discussed how the micro-pattern structure could enhance independence with color changes according to the viewing angle.

축광노면표시의 실내 및 현장 휘도 성능분석과 디지털이미지를 이용한 휘도분석 사전연구 (Performance Analysis of Laboratory and Field Luminance for Phosphorescent Line Marking and Preliminary Study of Luminance Analysis Using Digital Images)

  • 김상태;이용문;김흥래;최기주
    • 한국도로학회논문집
    • /
    • 제18권6호
    • /
    • pp.145-152
    • /
    • 2016
  • OBJECTIVES : Visibility at night can be improved by using retroreflection for short distances and phosphorescent line markings for long distances. In this study, we analyzed the characteristics of the phosphorescent line marking through a laboratory luminance test. Field performance analysis was performed through tests conducted on the road. We also examined the luminance measurement methods using the digital image obtained during the phosphorescent visibility evaluation. METHODS : In this study, the laboratory luminance test of the phosphorescent line marking was conducted using seven specimens to characterize the luminance changes according to the type of the glass beads, the thickness of the phosphorescent line marking, and the brightness and irradiation time of the light source. Phosphorescent and general line markings were made at 150 m to investigate the field luminance performance. A preliminary review of the luminance measurement methods was made using a digital image from a digital single-lens reflex (DSLR) camera. The measured luminance ratio of the general and the phosphorescent line markings was compared with the calculated luminance ratio using luminance analysis. RESULTS : Through the laboratory luminance test, it was seen that the change in luminance, which corresponds to the brightness of the light source, appears large but the influence of the thickness and irradiation time is low. The field performance test of the phosphorescent line marking conducted on the road involved measuring the luminance on the day the marking was made and 7 days after the marking was made. The luminance was found to be $190mcd/m^2$ at 30 min after sunset and approximately $10-12mcd/m^2$ 4h after sunset. The results of the luminance test were captured using a digital image for each time group. The luminance ratio of the phosphorescent line marking, when compared to that of the general line marking, showed a similar trend within a 13% maximum error. Additionally, when this luminance ratio is compared to the direct field measurement, it could be confirmed that the luminance ratio, as captured in the digital image, showed a similar tendency. CONCLUSIONS : 1) The change in luminance corresponding to the brightness of the light source is significant in comparison with that corresponding to the thickness and the irradiation time. In addition, the results of the field test for the phosphorescent line marking satisfied the phosphorescent fire protection standard. 2) We examined the validity of the luminance measurement method using a digital image and we concluded that the change in the luminance ratio shows a similar tendency in both the cases. The results can form the basis for luminance measurement methodology for the construction and maintenance of phosphorescent line markings.

콘택트 렌즈의 진동에 관한 연구 (Vibration of Contact Lenses)

  • 김대수
    • 한국안광학회지
    • /
    • 제6권1호
    • /
    • pp.13-29
    • /
    • 2001
  • 주기적으로 변하는 압력이 loose 또는 tight fitting 상태의 콘택트렌즈와 같은 diaphragm에 작용하여 진동이 발생하는 경우 diaphragm의 가장자리(edge)는 단순지지(simply supported) 또는 고정(rigidly clamped) 상태로 가정할 수 있으며, 이러한 가정하에 diaphragm의 진동을 해석할 수 있는 미분방정식과 그 해를 구하는 컴퓨터 프로그램을 작성하였으며 이 컴퓨터 모델을 사용하여 진폭 및 출력을 예측하고 diaphragm의 반경 및 두께, damping, 작용하는 압력의 진동수 등 제반 변수가 진동에 미치는 영향을 모사하였다. 외부 압력의 진동수가 어떤 범위 이상에서는 diaphragm의 파형은 한 개의 peak를 가지는 원호형에서 2개의 peak를 가지는 파도형으로 전환되며 이 때 진동수가 증가함에 따라 diaphragm의 바깥 부분의 peak가 안쪽 peak보다 높아지는 것을 알 수 있다. 이러한 경향이 시작되는 진동수는 diaphragm의 가장자리가 단순지지된 경우가 clamped 된 경우보다 훨씬 낮다. 단순지지된 diaphragm의 진동은 고정단 진동에 비하여 기본 공진(fundamental resonance)이 월등히 낮은 진동수에서 발생하며, 따라서 저주파 영역에서는 진동수가 낮아질수록 두 진동간의 진폭차가 커지지만 고주파 영역에서는 그 차이가 미미하게 된다. 또한 단순지지 diaphragm의 진동의 특징은 진동수의 증가에 따라 여러개의 공진(harmonics)이 발생하지만 전체적으로 진폭은 급격하게 감소한다. 그러나 저주파 영역에서 단순지지 진동의 진폭이 크다고 해도 출력은 낮기 때문에 diaphragm의 진동에 따른 출력(power)은 특정 진동수에서 하나의 주 peak를 갖는다. 단순지지된 diaphragm이 진동할 때 diaphragm의 출력 공진진동수는 두께가 증가할수록 감소한다. 이 경우 형성되는 harmonics의 출력은 기본공진의 강도에 비해 현저하게 떨어지는 것이 진폭의 경우와 대조적이다.

  • PDF

단결정 다이어몬드 공구를 이용한 Micro-V 홈 가공기구 (Mechanism of Micro-V Grooving with Single Crystal Diamond Tool)

  • 박동삼;서태일;김정근;성은제;한진용;이은상;조명우;최두선
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1223-1227
    • /
    • 2005
  • Fine microgroove is the key component to fabricate micro-grating, micro-grating lens and so on. Conventional groove fabrication methods such as etching and lithography have some problems in efficiency and surface integrity. This study deals with the creation of ultra-precision micro grooves using non-rotational diamond tool and CNC machining center. The shaping type machining method proposed in the study allows to produce V-shaped grooves of $40\mu{m}$ in depth with enough dimensional accuracy and surface. For the analysis of machining characteristics in micro V-grooving, three components of cutting forces and AE signal are measured and processed. Experimental results showed that large amplitude of cutting forces and AE appeared at the beginning of every cutting path, and cutting forces had a linear relation with the cross-sectional area of uncut chip thickness. From the results of this study, proposed micro V-grooving technique could be successfully applied to forming the precise optical parts like prism patterns on light guide panel of TFT-LCD.

  • PDF

Nucleation and growth mechanism of nitride films deposited on glass by unbalanced magnetron sputtering

  • Jung, Min J.;Nam, Kyung H.;Han, Jeon G.
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2001년도 춘계학술발표회 초록집
    • /
    • pp.14-14
    • /
    • 2001
  • Nitride films such as TiN, CrN etc. deposited on glass by PVD processes have been developed for many industrial applications. These nitride films deposited on glass were widely used for not only decorative and optical coatings but also wear and corrosion resistance coatings employed as dies and molds made of glass for the example of lens forming molds. However, the major problem of nitride coatings on glass by PVD process is non-uniform film owing to pin-hole and micro crack. It is estimated that nonuniform coating is influenced by a different surface energy between metal nitrides and glass due to binding states. In this work, therefore, for the evaluation of nucleation and growth mechanism of nitride films on glass TiN and CrN film were synthesized on glass with various nitrogen partial pressure by unbalanced magnetron sputtering. Prior to deposition, for the examination of relationship between surface energy and film microstructure plasma pre-treatment process was carried out with various argon to hydrogen flow rate and substrate bias voltage, duty cycle and frequency by using pulsed DC power supply. Surface energy owing to the different plasma pre-treatment was calculated by the measurement of wetting angle and surface conditions of glass were investigated by X-ray Photoelectron Spectroscopy(XPS) and Atomic Force Microscope(AFM). The microstructure change of nitride films on glass with increase of film thickness were analyzed by X-Ray Diffraction(XRD) and Scanning Electron Microscopy(SEM).

  • PDF

디스크형 3차원 홀로그래피 메모리에서 비초점 Fourier 면 홀로그램의 저장 효과 (Effects of storing defocused Fourier plane holograms in three-dimensional holographic disk memories)

  • 장주석;신동학
    • 한국광학회지
    • /
    • 제12권1호
    • /
    • pp.61-66
    • /
    • 2001
  • 두께가 얇은 기록매질을 사용하는 디스크형 홀로그래픽 메모리에서 비초점 Fourier aus 홀로그램을 저장할 때 홀로그램 당면적 저장밀도 및 기록 면에서의 빔세기분포 등을 조사하였다. 정확한 Fourier 면 홀로그램을 기록할때에는 2진 데이터를 표현하는 공간 광 변조기의 화소 피치가 클수록 면적 저장 밀도가 증가하지만, 비초점 Fourier 면 홀로그램을 저장할 때에는 면적 저장밀도를 최대로 하는 최적의 화소 피치가 존재함을 보였다. 일반적으로 홀로그램당 면적 저장밀도를 높이기 위해서는 데이터 영상을 집속하는 Fourier 변환 렌즈의 f/#가 가급적 작아야 한다. 이 경우 기록면에서의 빔세기 분포뿐만 아니라 기록면적이 비초점율에 따라 매우 민감하게 변하게 된다. 따라서 정확한 Fourier 면 홀로그램을 기록한다. 할지라도 최대의 면적 저장밀도를 얻기 위해서는 매질의 두께에 따른 비초점율의 영향을 고려해야 한다.

  • PDF

Study of PSII-treated PMMA, PHEMA, and PHPMA ; Investigation of Their Surface Stabilities

  • Hyuneui Lim;Lee, Yeonhee;Seunghee Han;Jeonghee Cho;Moojin suh;Kem, Kang-Jin
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1999년도 제17회 학술발표회 논문개요집
    • /
    • pp.204-204
    • /
    • 1999
  • The plasma source ion implantation(PSII) technique which is a method using high negative voltage pulse in plasma system has the potential to change the surface properties of polymer. PSII technique increase the surface free energy by introducing polar functional groups on the surface so that it improves reactivity, hydrophilicity, adhension, biocompatability, etc. However, the mobility of polymer chains enables the modified surface layers to adapt their composition to interfacial force. This hydrophobic recovery interrupts the stability of modified surfaces to keep for the long time. In this study, poly(methyl methacrylate)(PMMA), poly(2-hydroxyethyl methacrylate)(PHEMA), and polu(2-hydroxypropyl methacylate)(PHPMA) for contact lens application, were modified to improve the wettability with PSII technique and were investigated the surface stabilities. Polymer film was prepared with solution casting(3 wt.% solution) and was annealed at 11$0^{\circ}C$ under vacuum oven to remove solvent completely and to eliminate physical ageing. The thickness of the film measured by scanning electron microscopy (SEM) and surface profilometer was about 10${\mu}{\textrm}{m}$. Polymers were treated with different kinds of gases, pulse frequency, pulse with, pulse voltage, and treatment time. Even though PMMA, PHEMA, and PHPMA have similar repeat unit structure, the optimal treatment conditions and the tendency to hydrophobic recovery were different. PHPMA, more hydrophilic polymer than PMMA and PHEMA showd better wettability and stability after mild treatment. Surface tensions were obtained by water and diiodomethane contact angle measurements to monitor the relation between hydrophobic recovery and polymer structure. Different ion species in plasma change the polar component and dispersion component of polymer surface. For better wettability surface, the increase of polar component was a dominant factor. We also characterized modified polymer surfaces using x-ray photoelectron spectroscopy(XPS), secondary ion mass spectrometry(SIMS), Fourier Transform infrared spectroscopy(FT-IR), and SEM.

  • PDF