• Title/Summary/Keyword: Lens dose

Search Result 90, Processing Time 0.025 seconds

Dose Distribution for Eye Shielding Block In 6 MV Photon Beam Therapy (6 MV 광자선치료에서 안구차폐기구의 제작과 선량분포 측정)

  • Lee, Kyung-Ja
    • Radiation Oncology Journal
    • /
    • v.10 no.2
    • /
    • pp.155-161
    • /
    • 1992
  • The eye lens is known to be radiosensitive organ and catarat can be induced by relatively low dose of radiation. In the treatment of head and neck tumors, shielding blocks are frequently used to minimize dose on sensitive organs. The shielding block, which is made of high atomic number materials (cerrobend), produce significant dose perturbations in megavoltage photon beams. The effects of these perturbations of eye shielding blocks are measured with film and ion chambers for the treatment of head and neck malignancies. Optimum parameters for the treatment are suggested.

  • PDF

Evaluation of Dose Volume and Radiobiological Indices by the Dose Calculation Grid Size in Nasopharyngeal Cancer VMAT (비 인두암 체적 조절 호형 방사선 치료의 선량 계산 격자 크기에 따른 선량 체적 지수와 방사선 생물학적 지수의 평가)

  • Kang, Dong-Jin;Jung, Jae-Yong;Shin, Young-Joo;Min, Jung-Whan;Shim, Jae-Goo;Park, So-Hyun
    • Journal of radiological science and technology
    • /
    • v.43 no.4
    • /
    • pp.265-272
    • /
    • 2020
  • The purpose of this study was to investigate the dose-volume indices and radiobiological indices according to the change in dose calculation grid size during the planning of nasopharyngeal cancer VMAT treatment. After performing the VMAT treatment plan using the 3.0 mm dose calculation grid size, dose calculation from 1.0 mm to 5.0 mm was performed repeatedly to obtain a dose volume histogram. The dose volume index and radiobiological index were evaluated using the obtained dose volume histogram. The smaller the dose calculation grid size, the smaller the mean dose for CTV and the larger the mean dose for PTV. For OAR of spinal cord, brain stem, lens and parotid gland, the mean dose did not show a significant difference according to the change in dose calculation grid size. The smaller the grid size, the higher the conformity of the dose distribution as the CI of the PTV increases. The CI and HI showed the best results at 3.0 mm. The smaller the dose calculation grid size, the higher the TCP of the PTV. The smaller the dose calculation grid size, the lower the NTCP of lens and parotid. As a result, when performing the nasopharynx cancer VMAT plan, it was found that the dose calculation grid size should be determined in consideration of dose volume index, radiobiological index, and dose calculation time. According to the results of various experiments, it was determined that it is desirable to apply a grid size of 2.0 - 3.0 mm.

Treatment outcome and risk analysis for cataract after radiotherapy of localized ocular adnexal mucosa-associated lymphoid tissue (MALT) lymphoma

  • Park, Hee Hyun;Lee, Sea-Won;Sung, Soo Yoon;Choi, Byung Ock
    • Radiation Oncology Journal
    • /
    • v.35 no.3
    • /
    • pp.249-256
    • /
    • 2017
  • Purpose: We retrospectively reviewed the results of radiotherapy for localized ocular adnexal MALT lymphoma (OAML) to investigate the risk factors of cataract. Methods: Sixty-seven patients with stage IE OAML treated with radiotherapy at Seoul St. Mary's Hospital from 2001 to 2016 were included. Median treatment dose was 30 Gy. Lens protection was done in 52 (76%) patients. Radiation therapy (RT) extent was as follows: superficial (82.1%), tumor mass (4.5%), and entire orbital socket (13.4%). The risk factors for symptomatic cataract were analyzed using the Cox proportional hazard model. Results: Median follow-up time was 50.9 months (range, 1.9 to 149.4 months). All patients were alive at the time of analysis. There were 7 recurrences and there was no local recurrence. Median time to recurrence was 40.4 months. There were 14 cases of symptomatic cataract. Dose >30 Gy had hazard ratio of 3.47 for cataract (p = 0.026). Omitting lens protection showed hazard ratio of 4.10 (p = 0.008). Conclusions: RT achieves excellent local control of ocular MALT lymphoma. Consideration of RT-related factors such as lens protection and radiation dose at the stage of RT planning may reduce the risk of RT-induced cataract after radiotherapy.

THE STUDY OF PATIENT EXPOSURE AND PROTECTION FROM DENTAL RADIOGRAPHY (치과 X선 촬영에 있어서 환자에 대한 피폭과 방어에 관한 연구)

  • Park T. W.
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.9 no.1
    • /
    • pp.25-31
    • /
    • 1979
  • The utilization of x-ray for diagnosis and examination is increasing by about 5-15% every year, therefore, it would be mandatory to protect the patients from exposures and so, studies in this field are performed even now. In dental field, the area of irradiation is limited any to the head and neck area, but the irradiated angle is varied following the objected tooth, so the adjacent structures lens and thyroid gland would be fragile to radiation. And the scattered radiation is one of the complicated problems in the protection because of specificity of dental x-ray and its object structures. The author, by using TLD (Thermo luminescent Dosimeter; Teledyne Isotopes-Model 7300, Element; TLD 200(CaF₂:Dy) and Capintec(Capintec Model 192, PM-30 Diagnostic chamber 28㎖ active volume), tried a measurement of air dose distribution of the scattered radiation and the irradiated dose of lens and thyroid gland under the condition of taking the film on the left maxillary molar. The results were as follows: 1. The half value layer of adapted dental x-ray machine was measured, and is 1.44㎜ Al. 2. The time of irradiation on the left maxillary molar in the Alderson Rando Phantom, the measured doses of left and right lens, and thyroid gland were 8,9mR, 1,2mR and 2,8mR. Under the same conditions, the scattered radiation at the distance of 1 meter from the phantom were 84 μR at the front side, 11μR at the back side, 18μR at the right side and 72μR at the left side. 3. Under the same conditions, the dose showed higher value by about 5% in the presence of object(phantom) than in the case of absence.

  • PDF

Polymerization of HEMA by Electron beam Irradiation and Fabrication of Soft contact lens (전자빔조사에 의한 HEMA의 중합과 소프트콘택트렌즈 제조)

  • Hwang, Kwang-Ha;Shin, Joong-Hyeok;Sung, Yu-Jin;Jeong, Keun-Seung;Jun, Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.135-141
    • /
    • 2012
  • Purpose: Polymerization of HEMA(2-hydroxyethyl methacrylate) which can be used in the soft contact lens has been performed by using electron beam(EB) irradiation, and examined the best condition for the polymerization. Comparing the physical properties of the contact lenses to the one fabricated by thermal polymerization method, we check the use possibility of the EB irradiation to the fabrication of the soft contact lens. Methods: We investigated the degree of polymerization of the HEMA according to the composition of the monomer, the additive ratio and the dose of electron beam (0~120 kGy). The degree of polymerization was measured depending on the EB dose to research the best synthetic condition under the EB irradiation. The physical properties of the contact lens such as water content(%), oxygen transmissibility(Dk/t) and optical transmittance were analysed by using the FT-IR results with comparing the two different polymerization method (thermal and electron beam polymerization) with same additive ratio. Results: When the dose of electron beam was above 100 kGy, the degree of polymerization of HEMA was above 99% with regardless using cross-linker and initiator. The water content of the lens fabricated by EB method showed 10% higher than the one by the thermal method which was 40%. The lens fabricated by EB method also showed higher oxygen transmissibility(Dk/t) as same with the water content, and showed twice higher value in the lens fabricated by pure HEMA. According to the FT-IR results, hydrophilic property of the lens fabricated by EB method was increased due to increasing the intermolecular hydrogen bonding. It showed above 90% optical transmittance in the visible range of wavelength on the contact lenses fabricated by the both of two different polymerization method. Conclusions: The polymerization of HEMA without cross-linker and initiator was successful above 100 kGy of EB irradiation. Moreover the lens fabricated from the polymer synthesized by pure HEMA with 100 kGy of EB showed the highest water content and oxygen transmissibility. Therefore EB irradiation is another possible method to synthesize the polymer which can be used for the soft contact lens.

Slow Development of Diabetic Cataract in Streptozotocin-induced Diabetic Rats via Inhibition of Aldose Reductase Activity and Sorbitol Accumulation by Use of Aster koraiensis Extract (알도즈 환원효소 활성억제와 소비톨 축적 억제로 인한 벌개미취 추출물의 당뇨병성 백내장 발병 지연 효능)

  • Kim, Chan-Sik;Kim, Jung-Hyun;Jeong, Il-Ha;Kim, Young-Sook;Lee, Jun;Jang, Dae-Sik;Kim, Jin-Sook
    • Korean Journal of Pharmacognosy
    • /
    • v.40 no.4
    • /
    • pp.339-344
    • /
    • 2009
  • Diabetic cataract is a major complication of diabetes mellitus. Excess accumulation of sorbitol plays an important role in the pathogenesis of diabetic complications such as cataract formation. In this study, we investigated the inhibitory effect of the extract of the aerial parts of Aster koraiensis (AK) on diabetic cataractogenesis. To examine this further, we evaluated sorbitol accumulation during cataract development using streptozotocin-induced diabetic rat, an animal model of type 1 diabetes. Diabetic rats were treated orally with AK (100 mg/kg and 200 mg/kg body weight) once a day orally for 9 weeks. In vehicle-treated diabetic rats, lens opacity was increased, and lens fiber swelling and membrane rupture were observed. In addition, sorbitol accumulation in diabetic lens was markedly enhanced. However, AK treatment delayed the progression of diabetic cataract through the inhibition of sorbitol accumulation, and prevented lens fiber degeneration in a dose-dependent manner. These observations suggest that AK treatment can delay the progression of lens opacification in the diabetic rats during the early diabetic cataractogenesis.

Evaluation of Dose Distribution of 6 MV X-ray using Optical Dosimetry (광 도시메트리시스템을 이용한 치료용 6 MV X선 선량분포 평가)

  • Kim, Sunghwan
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.925-932
    • /
    • 2019
  • In this paper, we developed optical dosimetry system with a plastic scintillator, a commercial 50 mm, f1.8 lens, and a commercial high-sensitivity CMOS (complementary metal-oxide semiconductor) camera. And, the correction processors of vignetting, geometrical distortion and scaling were established. Using the developed system, we can measured a percent depth dose, a beam profile and a dose linearity for 6 MV medical LINAC (Linear Accelerator). As results, the optically measured percent depth dose was well matched with the measured percent depth dose by ion-chamber within 2% tolerance. And the determined flatness was 2.8%. We concluded that the optical dosimetry system was sufficient for application of absorbed dose monitoring during radiation therapy.

Assessment of Organ Dose in Mammoplasty Patient by Monte Carlo Simulation during Mammography (유방촬영 시 몬테칼로 전사모사를 이용한 유방 성형 환자의 장기선량 평가)

  • Kim, Ji-Soo;Cho, Yong-In;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.43 no.5
    • /
    • pp.337-341
    • /
    • 2020
  • Although the screening with a mammography has been shown to be economical, simple and effective in detecting breast cancer, it is accompanied by the risk from radiation. Therefore, this study analyzed the glandular dose and organ dose according to the target-filter combination and the presence and absence of implants using Monte Carlo simulation. The results indicate that at a tube voltage of 30 kV and a tube current of 50 mAs, the dose increased in the order of Mo/Mo. Mo/Rh, Rh/Rh and W/Rh in proportion to the atomic number of the target-filter. In addition, in phantom without implant a reduction in dose was seen when compared to the phantom with implant. The organ dose was highest in the lens except for the breast on the examination side regardless of the presence or absence of the implant. These results may contribute to use basic data for the diagnostic reference level of breast plastic surgery patients.

Surface Dose Measurement of Electron Beam within the Magnetic Field Variation (자기장 내에서 전자선의 표면선량 변화 측정)

  • Je, Jae-Yong;Noh, Kyung-Suk;Shin, Oon-Jae;Park, Cheol-Woo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.2
    • /
    • pp.103-107
    • /
    • 2008
  • Purpose: This paper describes a electron field presence of magnetic field, intensity and shape surface dose variation to clinical application possibility. Materials and Methods: The using 6 MeV electron and $10{\times}10\;cm^2$ field size, 9 hole to shielding block make the by measure the film, when the magnetic field position inside and outside of the X-Omat film and parallel plate ionization chamber using the surface dose measured. Results: Present of 4 cm to the side at angle about 3 degree from beam center, use of ring type magnetic is 0.9% increase the surface dose, lens block located in the magnetic field the surface dose 1.58% increase, half magnetic field's position on the side of them at the field center of the 3.6% increase of the surface dose. Conclusion: Surface dose variation is with magnetic field about the mean electron beam of progress direction change, orbit region patient's is inconvenient without surface dose increase percentage case goodness will be used as a useful way.

  • PDF