• Title/Summary/Keyword: Length frequency data

Search Result 618, Processing Time 0.024 seconds

NUMERICAL STUDY ON THE FREQUENCY CHARACTERISTICS OF SCREECH TONE IN A SUPERSONIC JET (초음속 제트의 스크리치 톤 주파수 특성에 관한 수치적 연구)

  • Kim, Yong-Seok;Ryu, Ki-Wahn;Hwang, Chang-Jeon;Lee, Duck-Joo
    • Journal of computational fluids engineering
    • /
    • v.12 no.1
    • /
    • pp.53-59
    • /
    • 2007
  • An axisymmetric supersonic screeching jet is numerically simulated to examine the length scales of screech frequency as well as screech tone generation mechanism. The axisymmetric Reynolds-averaged Navier-Stokes equations in conjuction with a modified Spalart-Allmaras turbulence model are employed. It is demonstrated that the axisymmetric jet screech tones can be simulated correctly and the numerical results are in good agreement with the experimental data. Instability waves, shock-cell structures and the phenomena of shock motion are investigated in detail to identify the screech tone generation mechanism. Shock spacings and standing wave length are analyzed to determine the dominent length scale crucial to the screech frequency formulation.

Correlation Between the External Laryngeal Length and the Habitual Speaking Fundamental Frequency (외 후두부 길이와 발화기본주파수 간의 상관관계)

  • Nam, Do-Hyun;Rheem, Sung-Sue;Choi, Hong-Sik
    • Phonetics and Speech Sciences
    • /
    • v.1 no.4
    • /
    • pp.187-193
    • /
    • 2009
  • For this study, the external laryngeal lengths of 9 females and 9 males with normal voices were measured together with their ages, heights, and weights, and after they read aloud sentences for 3 minutes, their habitual speaking fundamental frequencies, speaking low pitches, speaking high pitches, and vocal fold closed quotients were measured. The Spearman rank correlation analysis on these data showed a significant negative correlation between the external laryngeal length and the habitual speaking fundamental frequency for both females and males, a significant negative correlation between the external laryngeal length and the speaking high pitch for only males, a significant negative correlation between the external laryngeal length and the speaking low pitch for both females and males, and a significant positive correlation between the external laryngeal length and the vocal fold closed quotient for only males.

  • PDF

Construction of a Data Bank for Acoustic Target Strength with Fish Species, Length and Acoustic Frequency for Measuring Fish Size Distribution (어류 체장의 자동 식별을 위한 어종별, 체장별 및 주파수별 음향 반사 강도의 데이터 뱅크 구축)

  • LEE Dae-Jae;SHIN Hyeong-Il
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.38 no.4
    • /
    • pp.265-275
    • /
    • 2005
  • A prerequisite for deriving the abundance estimates from acoustic surveys for commercially important fish species is the identification of target strength measurements for selected fish species. In relation to these needs, the goal of this study was to construct a data bank for converting the acoustic measurements of target strength to biological estimates of fish length and to simultaneously obtain the target strength-fish length relationship. Laboratory measurements of target strength on 15 commercially important fish species were carried out at five frequencies of 50, 70, 75, 120 and 200 kHz by single and split beam methods under the controlled conditions of the fresh and the sea water tanks with the 389 samples of dead and live fishes. The target strength pattern on individual fish of each species was measured as a function of tilt angle, ranging from $-45^{\circ}$ (head down aspect) to $+45^{\circ}$ (head up aspect) in $0.2^{\circ}$ intervals, and the averaged target strength was estimated by assuming the tilt angle distribution as N $(-5.0^{\circ},\;15.0^{\circ})$. The TS to fish length relationship for each species was independently derived by a least-squares fitting procedure. Also, a linear regression analysis for all species was performed to reduce the data to a set of empirical equations showing the variation of target strength to a fish length, wavelength and fish species. For four of the frequencies (50, 75, 120 and 200 kHz), an empirical model for fish target strength (TS, dB) averaged over the dorsal sapect of 602 fishes of 10 species and which spans the fish length (L, m) to wavelength (\Lambda,\;m)$ ratio between 5 and 73 was derived: $TS=19.44\;Log(L)+0.56\;Log(\Lambda)-30.9,\;(r^2=0.53)$.

A Study on Phon Call Big Data Analytics (전화통화 빅데이터 분석에 관한 연구)

  • Kim, Jeongrae;Jeong, Chanki
    • Journal of Information Technology and Architecture
    • /
    • v.10 no.3
    • /
    • pp.387-397
    • /
    • 2013
  • This paper proposes an approach to big data analytics for phon call data. The analytical models for phon call data is composed of the PVPF (Parallel Variable-length Phrase Finding) algorithm for identifying verbal phrases of natural language and the word count algorithm for measuring the usage frequency of keywords. In the proposed model, we identify words using the PVPF algorithm, and measure the usage frequency of the identified words using word count algorithm in MapReduce. The results can be interpreted from various viewpoints. We design and implement the model based HDFS (Hadoop Distributed File System), verify the proposed approach through a case study of phon call data. So we extract useful results through analysis of keyword correlation and usage frequency.

Analysis of decimation techniques to improve computational efficiency of a frequency-domain evaluation approach for real-time hybrid simulation

  • Guo, Tong;Xu, Weijie;Chen, Cheng
    • Smart Structures and Systems
    • /
    • v.14 no.6
    • /
    • pp.1197-1220
    • /
    • 2014
  • Accurate actuator tracking is critical to achieve reliable real-time hybrid simulation results for earthquake engineering research. The frequency-domain evaluation approach provides an innovative way for more quantitative post-simulation evaluation of actuator tracking errors compared with existing time domain based techniques. Utilizing the Fast Fourier Transform the approach analyzes the actuator error in terms of amplitude and phrase errors. Existing application of the approach requires using the complete length of the experimental data. To improve the computational efficiency, two techniques including data decimation and frequency decimation are analyzed to reduce the amount of data involved in the frequency-domain evaluation. The presented study aims to enhance the computational efficiency of the approach in order to utilize it for future on-line actuator tracking evaluation. Both computational simulation and laboratory experimental results are analyzed and recommendations on the two decimation factors are provided based on the findings from this study.

Fluctuating lift and drag acting on a 5:1 rectangular cylinder in various turbulent flows

  • Yang, Yang;Li, Mingshui;Yang, Xiongwei
    • Wind and Structures
    • /
    • v.34 no.1
    • /
    • pp.137-149
    • /
    • 2022
  • In this paper, the fluctuating lift and drag forces on 5:1 rectangular cylinders with two different geometric scales in three turbulent flow-fields are investigated. The study is particularly focused on understanding the influence of the ratio of turbulence integral length scale to structure characteristic dimension (the length scale ratio). The results show that both fluctuating lift and drag forces are influenced by the length scale ratio. For the model with the larger length scale ratio, the corresponding fluctuating force coefficient is larger, while the spanwise correlation is weaker. However, the degree of influence of the length scale ratio on the two fluctuating forces are different. Compared to the fluctuating drag, the fluctuating lift is more sensitive to the variation of the length scale ratio. It is also found through spectral analysis that for the fluctuating lift, the change of length scale ratio mainly leads to the variation in the low frequency part of the loading, while the fluctuating drag generally follows the quasi-steady theory in the low frequency, and the slope of the drag spectrum at high frequencies changes with the length scale ratio. Then based on the experimental data, two empirical formulas considering the influence of length scale ratio are proposed for determining the lift and drag aerodynamic admittances of a 5:1 rectangular cylinder. Furthermore, a simple relationship is established to correlate the turbulence parameter with the fluctuating force coefficient, which could be used to predict the fluctuating force on a 5:1 rectangular cylinder under different parameter conditions.

Localized evaluation of actuator tracking for real-time hybrid simulation using frequency-domain indices

  • Xu, Weijie;Guo, Tong;Chen, Cheng
    • Structural Engineering and Mechanics
    • /
    • v.62 no.5
    • /
    • pp.631-642
    • /
    • 2017
  • Accurate actuator tracking plays an important role in real-time hybrid simulation (RTHS) to ensure accurate and reliable experimental results. Frequency-domain evaluation index (FEI) interprets actuator tracking into amplitude and phase errors thus providing a promising tool for quantitative assessment of real-time hybrid simulation results. Previous applications of FEI successfully evaluated actuator tracking over the entire duration of the tests. In this study, FEI with moving window technique is explored to provide post-experiment localized actuator tracking assessment. Both moving window with and without overlap are investigated through computational simulations. The challenge is discussed for Fourier Transform to satisfy both time domain and frequency resolution for selected length of moving window. The required data window length for accuracy is shown to depend on the natural frequency and structural nonlinearity as well as the ground motion input for both moving windows with and without overlap. Moving window without overlap shows better computational efficiency and has potential for future online evaluation. Moving window with overlap however requires much more computational efforts and is more suitable for post-experiment evaluation. Existing RTHS data from Network Earthquake Engineering Simulation (NEES) is utilized to further demonstrate the effectiveness of the proposed approaches. It is demonstrated that with proper window size, FEI with moving window techniques enable accurate localized evaluation of actuator tracking for real-time hybrid simulation.

Determining minimum analysis conditions of scale ratio change to evaluate modal damping ratio in long-span bridge

  • Oh, Seungtaek;Lee, Hoyeop;Yhim, Sung-Soon;Lee, Hak-Eun;Chun, Nakhyun
    • Smart Structures and Systems
    • /
    • v.22 no.1
    • /
    • pp.41-55
    • /
    • 2018
  • Damping ratio and frequency have influence on dynamic serviceability or instability such as vortex-induced vibration and displacement amplification due to earthquake and critical flutter velocity, and it is thus important to make determination of damping ratio and frequency accurate. As bridges are getting longer, small scale model test considering similitude law must be conducted to evaluate damping ratio and frequency. Analysis conditions modified by similitude law are applied to experimental test considering different scale ratios. Generally, Nyquist frequency condition based on natural frequency modified by similitude law has been used to determine sampling rate for different scale ratios, and total time length has been determined by users arbitrarily or by considering similitude law with respect to time for different scale ratios. However, Nyquist frequency condition is not suitable for multimode system with noisy signals. In addition, there is no specified criteria for determination of total time length. Those analysis conditions severely affect accuracy of damping ratio. The focus of this study is made on the determination of minimum analysis conditions for different scale ratios. Influence of signal to noise ratio is studied according to the level of noise level. Free initial value problem is proposed to resolve the condition that is difficult to know original initial value for free vibration. Ambient and free vibration tests were used to analyze the dynamic properties of a system using data collected from tests with a two degree-of-freedom section model and performed on full bridge 3D models of cable stayed bridges. The free decay is estimated with the stochastic subspace identification method that uses displacement data to measure damping ratios under noisy conditions, and the iterative least squares method that adopts low pass filtering and fourth order central differencing. Reasonable results were yielded in numerical and experimental tests.

Design of a Multiband Frequency Selective Surface

  • Kim, Dong-Ho;Choi, Jae-Ick
    • ETRI Journal
    • /
    • v.28 no.4
    • /
    • pp.506-508
    • /
    • 2006
  • A frequency selective surface (FSS), whose unit cell consists of a ternary tree loop loaded with a modified tripole, is proposed to block multiple frequency bands. Target frequency bands correspond to Korean personal communication services, cellular mobile communication, and 2.4 GHz industrial, scientific, and medical bands. Through the adjustment of inter-element and inter-unit cell gaps, and adjustment of the length of elements, we present an FSS design method that makes the precise tuning of multiple resonance frequencies possible. Additionally, to verify the validity of our approach, simulation results obtained from a commercial software tool and experimental data are also presented.

  • PDF

A Study on Prevention of Collision and Data Loss of the RFID System Using a Full-Length Instruction Code Method (무선인식 시스템의 완전 명령 코드 기법을 이용한 데이터 충돌 및 손실 방지에 관한 연구)

  • 강민수;신석균;이재호;박면규;이기서
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.7A
    • /
    • pp.756-765
    • /
    • 2004
  • Using single carrier frequency RFID system in one-to-multiple wireless communications, might be generated data loss because of data collisions. Conventional Anti-collision method prevent data loss from data collisions which are binary tree method and ALOHA. However, those two preventive measures also have week points which are strongly dependent on the time and space when passing through the recognition area. This paper suggests the full-length instruction code method which fits in to half-duplex method, prevents data collision effectively by calculating the non-transmitting time of multiple tags considering approaching time to the recognition area. After full-length instruction code method test using 13.56MHz bandwidth RFID system shows that full-length instruction code method could make better result than any other methods. Moreover, the record shows O(n) result after analyzing O-notation of conventional time-domain procedure.