• 제목/요약/키워드: Length Standard

Search Result 1,935, Processing Time 0.032 seconds

A Modified Length-Based Grading Method for Assessing Coronary Artery Calcium Severity on Non-Electrocardiogram-Gated Chest Computed Tomography: A Multiple-Observer Study

  • Suh Young Kim;Young Joo Suh;Na Young Kim;Suji Lee;Kyungsun Nam;Jeongyun Kim;Hwan Kim;Hyunji Lee;Kyunghwa Han;Hwan Seok Yong
    • Korean Journal of Radiology
    • /
    • v.24 no.4
    • /
    • pp.284-293
    • /
    • 2023
  • Objective: To validate a simplified ordinal scoring method, referred to as modified length-based grading, for assessing coronary artery calcium (CAC) severity on non-electrocardiogram (ECG)-gated chest computed tomography (CT). Materials and Methods: This retrospective study enrolled 120 patients (mean age ± standard deviation [SD], 63.1 ± 14.5 years; male, 64) who underwent both non-ECG-gated chest CT and ECG-gated cardiac CT between January 2011 and December 2021. Six radiologists independently assessed CAC severity on chest CT using two scoring methods (visual assessment and modified length-based grading) and categorized the results as none, mild, moderate, or severe. The CAC category on cardiac CT assessed using the Agatston score was used as the reference standard. Agreement among the six observers for CAC category classification was assessed using Fleiss kappa statistics. Agreement between CAC categories on chest CT obtained using either method and the Agatston score categories on cardiac CT was assessed using Cohen's kappa. The time taken to evaluate CAC grading was compared between the observers and two grading methods. Results: For differentiation of the four CAC categories, interobserver agreement was moderate for visual assessment (Fleiss kappa, 0.553 [95% confidence interval {CI}: 0.496-0.610]) and good for modified length-based grading (Fleiss kappa, 0.695 [95% CI: 0.636-0.754]). The modified length-based grading demonstrated better agreement with the reference standard categorization with cardiac CT than visual assessment (Cohen's kappa, 0.565 [95% CI: 0.511-0.619 for visual assessment vs. 0.695 [95% CI: 0.638-0.752] for modified length-based grading). The overall time for evaluating CAC grading was slightly shorter in visual assessment (mean ± SD, 41.8 ± 38.9 s) than in modified length-based grading (43.5 ± 33.2 s) (P < 0.001). Conclusion: The modified length-based grading worked well for evaluating CAC on non-ECG-gated chest CT with better interobserver agreement and agreement with cardiac CT than visual assessment.

Effect of digital noise reduction on the accuracy of endodontic file length determination

  • Mehdizadeh, Mojdeh;Khademi, Abbas Ali;Shokraneh, Ali;Farhadi, Nastaran
    • Imaging Science in Dentistry
    • /
    • v.43 no.3
    • /
    • pp.185-190
    • /
    • 2013
  • Purpose: The aim of the present study was to evaluate the measurement accuracy of endodontic file length on periapical digital radiography after application of noise reduction digital enhancement. Materials and Methods: Thirty-five human single-rooted permanent teeth with canals measuring 20-24 mm in length were selected. ISO #08 endodontic files were placed in the root canals of the teeth. The file lengths were measured with a digital caliper as the standard value. Standard periapical digital images were obtained using the Digora digital radiographic system and a dental X-ray unit. In order to produce the enhanced images, the noise reduction option was applied. Two blinded radiologists measured the file lengths on the original and enhanced images. The measurements were compared by repeated measures ANOVA and the Bonferroni test (${\alpha}=0.05$). Results: Both the original and enhanced digital images provided significantly longer measurements compared with the standard value (P<0.05). There were no significant differences between the measurement accuracy of the original and enhanced images (P>0.05). Conclusion: Noise reduction digital enhancement did not influence the measurement accuracy of the length of the thin endodontic files on the digital periapical radiographs despite the fact that noise reduction could result in the elimination of fine details of the images.

Variable Length Pseudo Noise (PN) Ranging System for Satellite Multiple Missions (위성 다중임무 수행을 위한 가변길이 의사 잡음 레인징 시스템)

  • Jeong, Jinwoo;Kim, Sanggoo;Yoon, Dongweon;Lim, Won-Gyu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.12
    • /
    • pp.14-21
    • /
    • 2013
  • In satellite operations and space exploration missions, a ranging is one of the most essential technologies to get its navigational information of space probes. Recently, the importance of cross-support between space agencies is increasing for more fine performance of space mission. For cross-support, mutually compatible ranging system between space agencies is recommended. For these reasons, the consultative committee for space data systems (CCSDS) recommends pseudo noise (PN) ranging as a digital standard ranging system. The length of PN sequence in CCSDS standard is proper for deep space missions, however, it is too long to use for ranging in near earth missions. In this paper, we propose Variable Length PN sequence schemes suitable for ranging of near earth satellites, such as low-earth orbit (LEO), medium-earth orbit (MEO) and Geostationary orbit (GEO). Therefore we propose variable length PN sequence ranging system including CCSDS standard for multiple missions.

Effects of the Red Tide and Toxic Dinoflagellates on the Survival and Growth of Larvae of the Mussel, Mytilus galloprovincialis

  • Lee, Chang-Hoon
    • The Korean Journal of Malacology
    • /
    • v.19 no.1
    • /
    • pp.25-32
    • /
    • 2003
  • To know the effects of the red tide and toxic dinoflagellates on survival and growth of larvae of the mussel, Mytilus galloprovincialis, laboratory experiments were conducted by incubating larvae with either unialgal culture of 4 dinoflagellate species (Amphidinium carterae, Prorocentrum triestinum, Gymnodinium impudicum, or Akashiwo sanguinea) or a standard food (Isochrysis galbana) for 10 days. The survival of larvae was higher than 80% when the food was A. carterae, G. impudicum, or A. sanguinea. The lowest survival (20%) was found when the food was P. triestinum. When the food was P. triestinum, the survival of larvae rapidly decreased from 87% at day 4 down to ca. 50% at day 6, and 20% at day 10. This implies that the larval population of M. galloprovincialis can seriously be affected if they are exposed to the red tide water dominated by P. triestinum for more than 4 days. Shell length of larvae either increased or decreased according to the food species. When the food was A. carterae, G. impudicum, or A. sanguinea, shell length of larvae increased. But, it decreased when the food was P. triestinum. Though shell length increased in 3 treatments, the daily increments (0.63 $\mu$ m for A. carterae, 0.46 m for $\mu$ G. impudicum, and 1.10 m for $\mu$ A. sanguinea) were smaller than that of the standard food (3.79 m for $\mu$ I. galbana). Correlation analyses chowed that the change in shell length was not significant when the food was A. carterae or G. impudicum. Therefore, all of 4 dinoflagellates affected the growth of M. galloprovincialis larvae: growth was negative for P. triestinum, nil for A. carterae and G. impudicum, and positive but lower than standard food for A. sanguinea. These imply that the dinoflagellates are less valuable as foods for M. galloprovincialis larvae. So, decreased growth rate of larvae is expected during red tides, which will consequently cause delayed metamorphosis or failure to recruitment to the adult populations. In considering the harmful effects of red tides on the aquatic ecosystem, not only the effects on adult populations of fish and shellfish, but also the effects on larval populations should be included.

  • PDF

Measurement of Joint Resistance of $(Bi,Pb)_2Sr_2Ca_2Cu_3O_x$/Ag Superconducting Tape by Field decay Technique (자장감쇠법을 이용한 $(Bi,Pb)_2Sr_2Ca_2Cu_3O_x$/Ag 초전도선재의 접합저항 측정)

  • Kim, Jung-Ho;Lee, Seung-Muk;Joo, Jin-Ho
    • Progress in Superconductivity
    • /
    • v.14 no.1
    • /
    • pp.1-10
    • /
    • 2012
  • We fabricated a closed coils by using resistive-joint method and the joint resistance of the coils were estimated by field decay technique in liquid nitrogen. We used the Runge-kutta method for the numerical analysis to calculate the decay properties. The closed coil was wound by $(Bi,Pb)_2Sr_2Ca_2Cu_3O_x$/Ag tape. Both ends the tape were overlapped and soldered to each other. The current was induced in a closed coils by external magnetic flux density. Its decay characteristic was observed by means of measuring the magnetic flux density generated by induced current at the center of the closed coil with hall sensor. The joint resistance was calculated as the ratio of the inductance of the loop to the time constants. The joint resistances were evaluated as a function of critical current of loop, contact length, sweep time, and external magnetic flux density in a contact length of 7 cm. It was observed that joint resistance was dependent on contact length of a closed coil, but independent of critical current, sweep time, and external magnetic flux density. The joint resistance was measured to be higher for a standard four-probe method, compared with that for the field decay technique. This implies that noise of measurement in a standard four-probe method is larger than that of field decay technique. It was estimated that joint resistance was $8.0{\times}10^{-9}{\Omega}$ to $11.4{\times}10^{-9}{\Omega}$ for coils of contact length for 7 cm. It was found that 40Pb/60Sn solder are unsuitable for persistent mode.

Design of Standard Value Intracranial Translucency of Fetus in Early Pregnancy Using Ultrasound (초음파를 이용한 임신초기 태아의 두개내투명대 표준치 제시)

  • Yang, Sung-Hee;Kim, Changsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.131-137
    • /
    • 2021
  • The purpose of this study was to present the reference value of the intracranial translucency(IT) of the fetus using the mid sagittal plane of the post brain in the early pregnancy ultrasound screening test and to find the clinical significance. From August 2018 to February 2020, the IT of 1529 singleton fetus whose crown lump length were 40.6 mm to 78.3 mm in length among the mothers undergoing regular checkups at Hospital I were measured and analyzed retrospectively. As the crown lump length increased, the IT showed a 54.3% explanatory power and tended to increase(p<0.001). In addition, through frequency analysis, the standard value for the percentile of the IT by gestational weeks was calculated. As a result, it was possible to establish a standard value for Koreans with an IT, and it will be usefully applied as an auxiliary screening test for spina bifida in the evaluation of fetal post brain in early pregnancy.

The comparison of the basic human body measurement definitions and anthropometric terms between KS and ISO (인체 측정 방법 및 측정 항목에대한 KS와 ISO의 비교)

  • 이영숙;김동진;남경희;안병덕;이관석
    • Proceedings of the ESK Conference
    • /
    • 1997.04a
    • /
    • pp.247-255
    • /
    • 1997
  • In this study, the comparison of the basic human body measurement definitions and anthropometric terms between the Korean Standard and the International Standard. Measurement definitions, measurement method and measurement terms of the international standard ISO 8559, 7250 were compard with the KSRI-88-103-IR. We have tried to suggest the new methods and new terms such as eye height, waist height, arm length.

  • PDF

A study on the Gal Do(骨度) of the Young Chu(靈樞) (영추(靈樞).골도(骨度)에 대(對)한 연구(硏究))

  • Du, Ja-Sung;Roh, Stella;Lee, Tae-Ho;Lee, Young-Sub;Keum, Kyoung-Su;Jeong, Heon-Young
    • Journal of Korean Medical classics
    • /
    • v.19 no.3
    • /
    • pp.305-313
    • /
    • 2006
  • According to the bone-standard measuring, the length between the elbow and the wrist has the span of 1.25 cheoks whereas it has the span of 1.2 cheoks or 1.2 cheoks today, the breadth of the chest has the span of 9.5 chons whereas it has the span of 8 chons today, and the length from celestial pivot to transverse bone has the span of 6.5 chons whereas it has the span of 5 chons, and the length from free rib region to thigh pivot has the span of 6 chons whereas it has the span of 9 chons today. It is said that all of the acupuncture points are correctly prescribed by the bone-standard measuring irrespective of men and women of all ages, fat and lean, and whether large or small in height. This lies at the root of the selecting acupuncture points. The bone standard in Spiritual Pivot and that in common use at present have a little difference and the bone standard of today is based upon A-B Classic. Spiritual Pivot named as Acupuncture Classic was in good preservation until the mid-eleventh century, but the book lost a lot in contents was the incomplete edition. In the 8th year of the king Cheoljong's reign of the North Song Dynasty in 1093, though the nine-volume Spiritual Pivot drafted from the Goryo Dynasty was published, the book was wanting in consistency. While on the other, I think that A-B Classic which has been in a state of perfection had a great influence on the healers of the day.

  • PDF

Technique of Tension Length Calculation for 350km/h High Speed Catenary System (최고운행속도 350km/h급 전차선로 장력구간길이 계산 기법)

  • Chang, Sang-Hoon;Lee, Ki-Won;Kwon, Sam-Young;Park, Jae-Woong
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.932-939
    • /
    • 2011
  • This paper deal with technique of tension length calculation for 350km/h high speed catenary system. Tension length affects in facility investment. Possibility of overlap increasing a tension length and the equipment investor decreases in order to decrease. Considers the parameter which specifies and the grudge which is possible long the fact that decides a tension length is the aim which is important plans overhead contact line. The element which decides a tension length with next following; (i) Operating range of tension device, (ii) Change of the horizontal tension which affects possibility of the effect which operates to the line and span, (iii) Tension of wire material the tensile force which is relation, (iv) Wire thermal expantion which relates with a standard temperature, (v) Curve radius, (vi) Wind velocity, (vii) Thermal range of overhead contact wire and mechanical design of tension mechanism etc.

  • PDF

A Study on Standardization of Pattern Design of Korean Men's Traditional Trousers (한복바지 원형설계의 표준화를 위한 연구)

  • 정옥임
    • Journal of the Korean Home Economics Association
    • /
    • v.39 no.10
    • /
    • pp.97-109
    • /
    • 2001
  • It is thought that a composition of trousers is related to fabrics with single breadth. Therefore, trousers are designed with pattern using this fabrics with single breadth. However, in the old pattern of trousers, the breadth of 33cm-35cm was not considered in designing patterns. In this context, deciding which pattern design is better is not easy as there are a variety of estimation methods. So in this study, standardization of drafting is pursued by an objective pattern design. For this, a base angle of the trouser closely relating to a form and function was measured and using the height and the base angle, a trouser pattern design was tried. For a measurement of the base angle, 5 subject were selected. They are 25-29 year-old male graduates with fine physical standard. The base angle was measured with symphysis pubis point as a standard when subjects sat with their legs crossed, when they stood with their legs open (not forced artificially) and when they laid down with their legs open. The distance between a knee inside joint and knees was measured three times and the resultant value was used for the pattern design. For a design of trousers, the height was applied and the base angle was fixed. As a pattern drawing, using the height, a base angle and circumference of the hip, a trouser was designed. The production method for the pattern design is as follow: (1) The length formula, is height + $\frac{height}{2}$ (2) The hip girth formula is $\frac{hipgirth}{2}$ - $\frac{hipgirth}{20}$(3) A crotch angle is fixed at $72^{\circ}$. (4) The ratio of outer leg length to leg width is 5 : 8. (5) The component ratio of the upper outer leg length to the pant length is 5 : 8. (6) The ratio of the division point of front right inner leg length and left inner width to upper outer leg length is 5 : 8.

  • PDF