• Title/Summary/Keyword: Left atrial function

Search Result 57, Processing Time 0.018 seconds

An Assessment of Allograft Function in Canine Single Lung Transplantation (일측 폐이식 실험견에서 이식폐의 기능 평가연구)

  • 박창권
    • Journal of Chest Surgery
    • /
    • v.28 no.12
    • /
    • pp.1096-1106
    • /
    • 1995
  • We experienced 7 cases of left single lung transplantation in 14 mongrel dogs and analyzed graft lung function by hemodynamics, blood gas analysis, chest X-ray, biopsy and perfusion lung scan. We performed right pulmonary artery cuff[PA cuff for analysis of graft lung function in 3 cases. The donor lungs were flushed with modified Euro-Collins solution[n=3 or low potassium dextran glucose solution[n=4 and preserved for 4 to 5 hours[n=4 or 24 hours[n=3 at 10o C and implanted to the dogs with similar weight . Assessment of left graft lung was done by occluding the right pulmonary artery for 10 minutes using PA cuff. Assessment for graft lung function was done immediately after an operation and after 3 days, 7days and 3 weeks postoperatively. Four dogs survived for 3days, 7days[2 cases and 3 weeks respectively. Other three dogs expired within 3 hours of reperfusion. Immediate perfusion scans of left lung in four survived dogs after reperfusion were 42.1%, 36% , 11% and 5.9% respectively, and another dog with 4.8% perfusion to left lung was dead due to left atrial thrombi after 3 hours reperfusion. In one case among three acute rejections follow-up perfusion scan was done on 3rd and 11th postoperative day and the result decreased from 36% perfusion immediate postoperatively to 21% and 15% respectively. Three expired dogs postoperatively couldn`t tolerate occlusion of right pulmonary artery with above 40 mmHg of mean pulmonary artery pressure. On the other hand, three survival dogs postoperatively tolerated occlusion of right pulmonay artery with less than 30 mmHg of mean pulmonary artery pressure. and one dog couldn`t tolerate same procedure immediate postopertively but in 2 hours reperfusion later tolerated with 29 mmHg of mean pulmonary artery pressure.In conclusion we couldn`t compare the effect of two flushing solutions but low potassium dextran glucose solution showed relatively safe preservation effect in cases with preservation of more than 20 hours. Also canine left single lung transplantation model with PA cuff indicated useful method for the assessment of graft lung function with effect of lung preservation.

  • PDF

Comparison of Radiofrequency Ablation and Cryoablation for the Recovery of Atrial Contractility and Survival

  • Kim, Kang Min;Chung, Suryeun;Kim, Sang Yoon;Kim, Dong Jung;Kim, Jun Sung;Lim, Cheong;Park, Kay-Hyun
    • Journal of Chest Surgery
    • /
    • v.51 no.4
    • /
    • pp.266-272
    • /
    • 2018
  • Background: Limited comparative data are available on the efficacy of cryoablation versus radiofrequency ablation in patients with atrial fibrillation. This study aimed to compare radiofrequency ablation and cryoablation with regard to clinical outcomes and the restoration of sinus rhythm or atrial contractility. Methods: A total of 239 patients who underwent surgical ablation between August 2003 and December 2016 at our institution were included. The patients were divided into 2 groups according to the energy device that was used (group A: n=140, radiofrequency ablator; group B: n=99, cryoablator). Echocardiographic data, overall survival, and major cardiovascular and cerebrovascular event (MACCE)-free survival were compared between the 2 groups. Results: At 1 year of follow-up, the atrial contractility recovery rate was 32.2% (19 of 59) in group A and 48.8% (21 of 44) in group B. In addition, cryoablation was found to be a predictive factor for the recovery of atrial contractility (cryoablation vs. radiofrequency ablation: odds ratio, 2.540; 95% confidence interval, 1.063-6.071; p=0.036). The left ventricular ejection fraction was significantly higher in group B ($53.1%{\pm}11.5%$ vs. $59.1%{\pm}6.3%$, p=0.001). The median follow-up duration was 36 months. The 5-year overall survival rate was $80.1%{\pm}3.6%$ in group A and $92.1%{\pm}2.9%$ in group B (p=0.400). The 5-year MACCE-free survival rate was $70.3%{\pm}4.0%$ in group A and $70.9%{\pm}5.6%$ in group B (p=0.818). Conclusion: Cryoablation was associated with a higher atrial contractility restoration rate and better left ventricular function than radiofrequency ablation. However, no significant relationship was observed between the energy source and overall or MACCE-free survival.

Clinical Study of Ventricular Function Following Open Heart Surgery by Radionuclide Angiocardiogram - left ventricular ejection fraction by ECG gated blood pool scan - (방사성 동위원소를 이용한 개심술 전후의 심실기능 변화에 관한 연구: ECG gated blood pool scan을 이용한 ejection fraction 검사)

  • Lee, Jeong-Cheol;Kim, Gyu-Tae
    • Journal of Chest Surgery
    • /
    • v.19 no.1
    • /
    • pp.25-34
    • /
    • 1986
  • Recently, radionuclide angiocardiogram is one of the most common procedure for assessment of ventricular performance due to its distinctive advantages such as safety, accuracy, and ease of repeated studies. Also, measurement and comparison between pre and postoperative left ventricular ejection fraction [LVEF] are meaningful for assessing the severity of myocardial damage which occurred during open heart surgery and the status of myocardial recovery. We obtained pre and post operative LVEF using radionuclide angiocardiogram on 30 patients composed of atrial septal defect, ventricular septal defect, cyanotic congenital heart disease, and valvular heart disease who undergone the open heart surgery from March to august 1984. The study revealed that ventricular septal defect and mitral valvular heart disease showed 8.1% and 6.2% decreases of postoperative LVEF, respectively. But, there are little increases of postoperative LVEF in the atrial septal defect and cyanotic congenital heart disease. In ventricular septal defect, each group of Qp/Qs over 2.0 and systolic pulmonary artery pressure over 50mmHg showed significant 17% and 14.7% decreases of postoperative LVEF, respectively. Considering the duration of the aortic cross clamping times and closing methods of VSD, each group of duration over 30 min. and of patch closure showed 13.9% and 14.2% decreases of LVEF between pre and postoperative status respectively which was significant finding statistically.

  • PDF

Echocardiographic Findings after Mitral Valve Replacement (승모판막치환수술 전후 심장초음파 소견의 변화에 관한 연구)

  • 이상진
    • Journal of Chest Surgery
    • /
    • v.27 no.8
    • /
    • pp.656-663
    • /
    • 1994
  • Evaluation of heart function is of importance in assessing the results of valvular heart surgery. Information on volume and functional change of heart chamber can be obtained by cardiac catheterization and echocardiography. We studied 41 patients with mitral stenosis[MS] and 23 patients with mitral regurgitation[MR] using M-mode echocardiography before and after mitral valve replacement[MVR] at Pusan Paik Hospital. Preoperative cardiac catheterization was available in 56 cases, and the results were obtained as follows. 1. In patients with MS, preoperative average LV end-diastolic dimension[EDD] and end-systolic dimension[ESD] were remained within normal range, but postoperative EDD and ESD were significantly decreased[P<0.01]. The preoperative and postoperative LV ejection fraction[EF] were remained within the normal range and no significant change[P>0.05]. The preoperative left atrial dimension[LAD] was enlarged considerably above normal[P<0.01], but was significantly decreased after surgery[P<0.001]. The preoperative LV posterior wall thickness[PWTh] was within normal range, and no significant change after surgery[P>0.05]. 2. In patients with MR, preoperative average end-diastolic dimension[EDD] and end-systolic dimension[ESD] were significantly greater than normal[P<005], but postoperative EDD and ESD were significantly decreased[P<0.01]. The preoperative LV ejection fraction[EF] and fractional shortening[FS] were within normal range, and no significant change after surgery[P>0.05].The preoperative left atrial dimension[LAD] was enlarged considerably above normal [P<0.01], but was significantly decreased after surgery[P<0.001].The preoperative LV posterior wall thickness[PWTh] was within normal range, and no significant change after surgery[P>0.05].

  • PDF

Changes of the Plasma Atrial Natriuretic Peptide during Myocardial Infarction in Rats (흰쥐 심근경색 모델에서 혈장 Atrial Natriuretic Peptide의 변화)

  • Ahn, Dong-Choon;Kim, In-Shik
    • Journal of Veterinary Clinics
    • /
    • v.29 no.2
    • /
    • pp.148-153
    • /
    • 2012
  • Atrial natriuretic peptide (ANP) is associated with the variety of disorders of myocardial function. The effect, however, of myocardial infarction (MI) on ANP has not been fully described. Thus, this study investigated the effect of experimental MI, induced by left coronary artery ligation, on ANP secretion. Male Sprague-Dawley rats aged 60 d underwent ligation of the left anterior descending coronary artery to induce MI and were compared with a group that underwent a sham operation. Rats of sham operation had a similar procedure without having the suture tightened around the coronary artery. Animals were sacrificed at 1, 3, 6, 12, and 18 h or 1, 3, 5, 7, 14, and 30 d after the procedure. MI size was assessed by planimetry and perimetry, and plasma ANP levels were determined by radioimmunoassay. Mean infarct size was 39.6-44.5% of the left ventricle after coronary occlusion in experimental groups. No significant differences were observed in infarct size among groups. In contrast, the concentration of plasma ANP was significantly higher at 1, 3, 6, 12, 18, and 24 h after left coronary artery ligation than in sham animals. This parameter, however, did not differ significantly at 3, 5, 7, 14, and 30 d after ligation compared with sham-ligated controls. These results demonstrate that plasma ANP levels are markedly increased in the early phase of MI in the male rat and can be a useful biomarker for diagnosis in acute MI.

Is It Safe to Preserve Left Atrial Appendage During Maze Procedure?

  • Kyungsub Song;Woo Sung Jang;Namhee Park;Yun Seok Kim;Jae Bum Kim
    • Korean Circulation Journal
    • /
    • v.53 no.8
    • /
    • pp.566-577
    • /
    • 2023
  • Background and Objectives: The left atrial appendage (LAA) can contribute significantly to LA mechanical contraction. Nevertheless, the preventive effect of LAA occlusion during the maze procedure against cerebral infarction remains controversial. In this study, we compared the surgical, cardiac hemodynamic, and neurologic outcomes between LAA preservation and occlusion performed during the maze procedure. Methods: Between January 2015 and August 2021, 252 patients underwent the maze procedure using cryoablation at our medical center. After excluding patients according to our exclusion criteria (i.e., mechanical prosthesis implantation, preexisting LAA thrombus), LAA was preserved in 113 patients (non-occlusion group) and occluded in 75 patients (occlusion group). Outcomes were compared using propensity score matching (PSM). Results: PSM did not reveal significant intergroup differences in baseline characteristics between the non-occlusion (n=53) and occlusion (n=53) groups. During a median follow-up of 44 months, 2 patients in the non-occlusion group (3.8%) experienced ischemic strokes. There was no significant difference in the rate of freedom from stroke (p=0.19) and major adverse cardiac events (p=0.43) between the 2 groups. Through echocardiography at 1-year follow-up, a statistically significant difference in LA mechanical contraction was observed between the non-occlusion group and occlusion group (24 of 33 [72.7%] vs. 18 of 37 [48.6%], respectively; p=0.04). Conclusions: In this study, preservation of the LAA during the maze procedure resulted in better LA function than LAA occlusion, with similar rates of stroke.

Isolated Working Canine Heart Perfusion Apparatus for Evaluation of Myocardial Protection Methods (심장기능 평가를 위한 견 적출심장 관류장치의 설계)

  • 이종국
    • Journal of Chest Surgery
    • /
    • v.21 no.2
    • /
    • pp.246-253
    • /
    • 1988
  • An in vitro model providing with a recirculating perfusion apparatus using an isolated canine heart and its autogenous blood, which was prepared for study of myocardial protection method. This apparatus was easily used by quick connect system and maintained well heart function for about 2 hours. The Langendorff perfusion was initiated for a 10 minute period by introducing perfusate at 37` into the aorta from aortic reservoir located 100 cm above the heart. The isolated perfused working canine heart model was a left heart preparation in which oxygenated perfusion medium [at 37K] entered the cannulated left atrium at a constant flow rate [900ml/ min] under 20 mmHg overflow system and was spontaneously ejected[no electrical pacing] via an cannula against a hydrostatic pressure of 80 cm H2O. During this working period, various indices of cardiac function were measured. The cardiac functions were stable for over 2 hours with perfusion of Krebs-Henseleit solution and autologous blood[1:1] mixture in volume and maintained heart rate ]]3-122/bpm peak systolic pressure 109-113 mmHg, cardiac output 900 ml / min and left atrial mean pressure 8-9 mmHg. In this model, the efficiency of myocardia] protection could be easily measured by means of functional, enzymatic, biochemical and ultrastructural assessment. And also, we believe this model to be a useful assessment screening model of recovery state after long duration of myocardial preservation of donor heart without difficult transplantation procedures.

  • PDF

Treatment of Atrial Fibrillation with Microwave (Microwave를 이용한 심방세동의 치료)

  • 조광현;최강주;강도균;전희재;윤영철;이양행;황윤호
    • Journal of Chest Surgery
    • /
    • v.36 no.5
    • /
    • pp.329-334
    • /
    • 2003
  • Backgound: Cryoablation and radiofrequency ablation have been used to treat the atrial fibrillation. Some reports insisted that the microwave ablation Is a better method for a deep and extensive lesion. Material and Method: From December 2001 to July 2002, we peformed 8 microwave ablations in patients who needed mitral valve surgery (7 MVR, 1 MVR+AVR). There were 3 men and 5 women, and their mean age was 43.4$\pm$8.3 years and mean follow up period was 5.6$\pm$2.4 months respectively. The microwave was applied on endocardium or epicardium by Lynx (Afx, inc.) using a power of 45 watts for 25 seconds. We studied the left atrial dimension, the left atrial function and the sinus conversion with echocardiography and electro-cardiography at three times; 1) before the operation, 2) immediately after the operation, and 3) 6 months after the operation. Result: There was no complication and no mortality. The mean aortic clamping time was 104.6$\pm$25.0 minutes, and the mean total bypass time was 130.5$\pm$28.7 minutes. The rate of sinus conversion was 75%, A wave across the mitral valve was a mean of 77.0$\pm$24.8 cm/sec, and the AVE was a mean of 0.46$\pm$0.17 at 5.6 months postoperatively Conclusion: There was no difference in the early result of microwave ablation compared to other methods. The microwave ablation was an acceptable method due to its convenient application especially in beating heart.

Pulmonary Function Following Open Heart Surgery -early and late postoperative changes- (개심술후 폐기능 -수술직후 및 장기간의 추이에 대하여-)

  • 이성행
    • Journal of Chest Surgery
    • /
    • v.13 no.4
    • /
    • pp.364-374
    • /
    • 1980
  • Twenty-two patients were selected for evaluation of pre-and postoperative pulmonary function. These patients were performed open cardiac surgery with the extracorporeal circulation from March 1979 to July 1980 at the Department of Thoracic and Cardiovascular Surgery, Kyungbook National University Hospital. Patients were classified with ventricular septal defect 5 cases, atrial septal defect 5 cases, tetralogy of Fallot 5 cases, mitral stenosis 4 cases, rupture of aneurysm of sinus Valsalva 1 case, left atrial myxoma I case, and aortic insufficiency 1 case. The pulmonary function tests were performed and listed: [1] respiratory rate, tidal volume [TV], and minute volume[MV], [2] forced vital capacity [FVC] and forced expiratory volume[FEV 0.5 & FEV 1.0], [3] forced expiratory flow [FEF 200-1200 ml & FEF 25-75%]. [4] Maximal voluntary ventilation [MVV], [5] residual volume [RV] and functional residual capacity[FRC], measured by a helium dilution technique. Respiratory rate increased during the early postoperative days and tidal volume decreased significantly. These values returned to the preoperative levels after postoperative 5-6 days. Minute volume decreased slightly, but essentially unchanged. Preoperative mean values of the forced vital capacity, functional residual capacity and total lung capacity decreased [63.2%, 87.2% & 77.3% predicted, respectively], and early postoperatively these values decreased further [19.6%, 76.0% & 38.0% predicted], but later progressively increased to the preoperative levels. In residual volume, there was no decline in the preoperative mean values [100.9% predicted] and postoperatively the value rather increased [106.3-161.7% predicted]. Forced expiratory volume [FEV 0.5 & FEV 1.0] and forced expiratory flow [FEF 200-1200 ml & FEF 25-75%] also revealed significant declines in the early postoperative period. There was no significant difference in values of the spirometric pulmonary function tests, such as FEF 1.O and FEF 25-75% between successful weaning group [17 cases] extubated within 24 hrs post-operatively and unsuccessful weaning group [5 cases] extubated beyond 24 hrs. Static compliance and airway resistance measured for the two cases during assisted ventilation, however, any information was not obtained. Long term follow-up pulmonary function studies were carried out for 8 cases in 9 months post-operatively. All of the results returned to the pre-operative or to normal predicted levels except FVC, FEV 1.0, and FEF 25-75% those showed minimal declines compared to the pre-operative figures.

  • PDF