• Title/Summary/Keyword: Lee Joon Gu

Search Result 328, Processing Time 0.025 seconds

Development of system repairing & reinforcing for irrigation & draingage structure (농업기반 수리구조물의 보수보강 공법 시스템 구축)

  • Kim, Kwan-Ho;Park, Kwang-Su;Kim, Myeong-Won;Lee, Joon-Gu;Kim, Han-Joong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.289-292
    • /
    • 2005
  • It is not feasible for agricultural facility managers to estimate how severe damages are and what are causes of them when agricultural hydraulic facilities get damaged for some reasons. Moreover, it is nearly impossible for agricultural facility managers to take immediate actions to repair and reinforce the damaged structures. Thus, there have been needs for well-established systems to help agricultural facility managers understand its severity and causes, and take proper actions to reduce speed of deterioration and to repair/reinforce them. Thus repairing and reinforcing systems of agricultural hydraulic structures based on agricultural facility management policies, developed in this study, can be efficiently used in field works to determine top priority location and the budget of repairing and reinforcing projects if detailed information of damages in concrete structures and damage types are well compiled and classified with standardized image data complemented.

  • PDF

An experimental study on the difference of temperature and strength according to member size for cold weather concrete (한중콘크리트의 부재 단면별 온도범위와 강도변화특성에 관한 실험적 연구)

  • Kim, Meyong-Won;Park, Kwang-Su;Cho, Young-Kweon;Lee, Joon-Gu;Kim, Kwan-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.421-424
    • /
    • 2005
  • Discusses the results of an investigation of the relationship between maturity in field-cured specimens and that from the thinner dimension structure to thick, particularly at cold weather concrete. Tests were carried out on two different concrete mixes with 28 day compressive strengths ranging approximately 30MPa. Ready-mixed concrete was used, and test specimens were the conventional field-cured 10$\times$20cm concrete cylinder with insulating materials and without them, and test structures were the thinner(width 20cm), the general(width 40cm), the thick dimension(width 60cm), respectively. Tests were performed at age of 3, 7, 14, 28 day. Analyses of test results show that the maturity of concrete for require compressive strength was suggested to be keep higher than $164D^{circ}D$ until at least from 8day to 10day

  • PDF

Effects of Blade Configuration on the Performance of Induced Gas Flotation Machine (익형 변화에 따른 유도공기부상기 성능특성 연구)

  • Song, You-Joon;Lee, Ji-Gu;Kim, Youn-Jea
    • The KSFM Journal of Fluid Machinery
    • /
    • v.20 no.2
    • /
    • pp.41-46
    • /
    • 2017
  • The flotation performance of the induced gas flotation (IGF) machine is considerably influenced by geometric configurations of rotor and stator. The interaction of rotor and stator, which are the most important components in IGF, serves to mix the air bubbles. Thus, the understanding of flow characteristics and consequential analysis on the machine are essential for the optimal design of IGF. In this study, two-phase (water and air) flow characteristics in the forced-air mechanically stirred Dorr-Oliver flotation cell was investigated using ANSYS CFX. In addition, the void fraction and the velocity distributions are determined and presented with different blade configurations.

Concrete Strength Prediction by Early-Age(7-day) (7일 재령 압축강도에 의한 콘크리트 품질판정)

  • Kim Meyong Won;Park Kwang Su;Kim Kwan Ho;Lee Joon Gu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.137-140
    • /
    • 2004
  • Hydraulic structures have been constructed with low cost concrete so as to increase the investment efficiency. As the construction of agricultural irrigation and drainage project is concentrated on off-farming season and come to construction less than 28-day strength in quality control. As we are aware the major thrust construction of short period is now in hydraulic structures rather then the large- scale. This paper will propose the relationship between the 7-day and 28-day compressive strength of concrete be investigated. Test will be carried out on nine different concrete mixes and 180 core drilled form the hydraulic structures with 7-day and 28-day compressive strengths ranging approximately from 24 to 30Mpa.

  • PDF

Using the maturity method in quality control of cold weather concrete (적산온도에 의한 동절기 콘크리트의 품질관리)

  • Lee, Joon-Gu;Park, Kwang-Su;Cho, Young-Kweon;Kim, Meyong-Won;Kim, Kwan-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.245-248
    • /
    • 2004
  • The prediction of the strength of cold weather concrete and the analysis of the insulating material effect were performed to apply the prediction function with maturity concept for quality control of them in this study. The several results driven from above processes were summarized as followings. First, the difference between the temperature of cylinder covered with insulating materials and that of cylinder without them was $4.5\~6.0^{\circ}C$. Second, the maturity of concrete was suggested to be keep higher than $96\~115^{\circ}C{\cdot}D$ until at least 7-day and the temperature of fresh concrete was suggested to be keep above $10^{\circ}C$ directly after set.

  • PDF

Repairing & Reforcing DB Construction for Irrigation & Drainage Structure (수리구조물의 보수보강 DB구축)

  • Kim, Kwan-Ho;Park, Kwang-Su;Kim, Myeong-Won;Lee, Joon-Gu;Yoo, Jung Hoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.189-192
    • /
    • 2006
  • Following the evaluation of the irrigation & drainage structure, a suitable repair and reinforcing procedure can be selected based on this report. Successful procedures take into account the causes of the crack. This provides a survey of crack repair methods, including a summary of the characteristics of the cracks that may be repaired with each procedure, the type of irrigation & drainage structure that have been repaired and a summary of the procedures that are used. Readers are also directly contacted to the website(http:/rri.karico.co.kr/rricon). This report is intended to support the purposes, philosophy, and needs, using easily understood graphics and photos from the construction fields. The results of this study will be distributed to the public official in technical post, the operator in construction site and the member of Korea Agricultural & Rural Infrastructure Corporation and etc.

  • PDF

Bayesian analysis for the bivariate Poisson regression model: Applications to road safety countermeasures

  • Choe, Hyeong-Gu;Lim, Joon-Beom;Won, Yong-Ho;Lee, Soo-Beom;Kim, Seong-W.
    • Journal of the Korean Data and Information Science Society
    • /
    • v.23 no.4
    • /
    • pp.851-858
    • /
    • 2012
  • We consider a bivariate Poisson regression model to analyze discrete count data when two dependent variables are present. We estimate the regression coefficients as sociated with several safety countermeasures. We use Markov chain and Monte Carlo techniques to execute some computations. A simulation and real data analysis are performed to demonstrate model fitting performances of the proposed model.

A Study On the Mix Design and Quality Control System of High Strength Concrete for the Construct ion of High Rise Complex Structure (초고층 주상복합구조물에 적용한 고강도 콘크리트의 배합설계 및 품질관리 시스템에 관한 연구)

  • Kim, Sun-Gu;Lee, Sang-Soo;Won, Cheol;Park, Sang-Joon;Kim, Dong-Seok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2001.11a
    • /
    • pp.40-45
    • /
    • 2001
  • The purposes of this study were mix design and quality control of high strength concrete for the construction of high rise complex structure. Desired performances of this high strength concrete were slump flow 50$\pm$10cm, air content 4.5$\pm$1.5% and design strength 400kgf/$cm^2$. Experimental flow was that optimal mix design was selected in the indoor experiment and after that, producing test was done in the batcher plant. Excel lent results of experiment was obtained from binder content 475kg/$m^2$ with replacement ratio 10% of fly ash. The results of field application of high strength concrete was sufficiently satisfied both flowability and compressive strength.

  • PDF