• 제목/요약/키워드: Least-pulse

검색결과 116건 처리시간 0.025초

펄스 중첩 보정 스펙트럼의 라이브러리 최소자승법에의 이용 (Application of Pulse Pile-Up Correction Spectrum to the Library Least-Squares Method)

  • 이상훈
    • Journal of Radiation Protection and Research
    • /
    • 제31권4호
    • /
    • pp.173-179
    • /
    • 2006
  • 개선된 몬테칼로 코드 CEARPPU는 고계수율 상황에서의 펄스 중첩 보정 스펙트럼을 제공한다. 중성자 방사화 분석을 위하여 CEARPPU를 이용하여 보정된 스펙트럼으로 라이브러리 최소자승 동위원소 방사능 분석을 수행하여 보정하지 않은 스펙트럼을 이용하는 방법보다 우수한 결과를 얻었다.

맥파전달속도 계산을 위한 특징점 검출 알고리즘 개발 (Development of a Characteristic Point Detection Algorithm for the Calculation of Pulse Wave Velocity)

  • 이낙범;임재중
    • 전기학회논문지
    • /
    • 제57권5호
    • /
    • pp.902-907
    • /
    • 2008
  • Shape of the pulse waveform is affected by the visco-elasticity characteristics of the arterial wall and the reflection waves generated at the bifurcations of arterial branches. This study was designed to improve the accuracy for the extraction of pulse wave features, then proved the superiority of the developed algorithm by clinical evaluation. Upstroke point of the pulse wave was used as an extraction feature since it is minimally affected by the waveform variation. R-peak of the ECG was used as a reference to decide the minimum level, then intersection of the least squares of regression line was used as an upstroke point. Developed algorithm was compared with the existing minimum value detection algorithm and tangent-intersection algorithm using data obtained from 102 subjects. Developed algorithm showed the least standard deviation of $0.29{\sim}0.44\;m/s$ compared with that of the existing algorithms, $0.91{\sim}3.66\;m/s$. Moreover, the rate of standard deviation of more than 1.00m/s for the PWV values reduced with the range of $29.0{\sim}42.4%$, which proved the superiority of the newly developed algorithm.

FCC 방출 전력 마스크에 적합한 UWB 펄스 생성 방법 (UWB Pulse Generation Method for the FCC Emission Mask)

  • 박장우;조성언;조경룡
    • 한국항행학회논문지
    • /
    • 제10권4호
    • /
    • pp.333-341
    • /
    • 2006
  • 본 논문에서는 시간도약 UWB 신호의 주파수 특성을 해석하고 실제의 신호의 전력 스펙트럼은 주로 사용된 펄스의 전력 스펙트럼에 의하여 결정됨을 보였다. 또한, 코드 스펙트럼의 상세한 해석을 하였다. 그리고 FCC의 emission mask를 충분히 활용할 수 있는 펄스의 설계 방법을 제시하였다. 제시한 펄스 설계방법은 가우시안 미분 펄스의 시간 지연 파형을 선형으로 결합하였으며 결합된 새로운 파형은 FCC의 전력 밀도 마스크를 충분히 활용할 수 있다. 이때 선형 결합 계수는 LSE(Least Square Error)를 최소화 하도록 계산하였다. 다양한 계수의 수와 기본 펄스들에 대한 결과적인 펄스의 전력 스펙트럼 밀도 및 파형을 계산하였다.

  • PDF

8kbps 비트율을 갖는 ACFBD-MPC와 LMS-MPC를 통합한 ACLMS-MPC 부호화 방식 (An ACLMS-MPC Coding Method Integrated with ACFBD-MPC and LMS-MPC at 8kbps bit rate.)

  • 이시우
    • 인터넷정보학회논문지
    • /
    • 제19권6호
    • /
    • pp.1-7
    • /
    • 2018
  • 본 논문에서는 합성 음성파형의 일그러짐을 제어하기 위하여 V/UV/S(Voiced / Unvoiced / Silence)의 스위칭을 사용하고, 피치구간마다 멀티펄스를 보정하며, 무성자음(Unvoiced)의 근사합성에 특정주파수를 이용하는 ACFBD-MPC(Amplitude Compensation Frequency Band Division - Multi Pulse Coding)와 LMS-MPC(Least Mean Square - Multi Pulse Coding)를 통합한 8kbps ACLMS-MPC(Amplitude Compensation and Least Mean Square - Multi Pulse Coding) 부호화 방식을 제안하고자 한다. 여러 방식을 통합하는데 있어서, 음성파형의 일그러짐을 줄이면서 유성음과 무성음의 비트율을 8kbps로 조정하는 것이 중요하다. 유성음과 무성음의 비트율을 8kbps로 조정함에 있어서, 개별피치를 이용하여 대표구간의 멀티펄스를 피치구간마다 복원함으로서 음성파형을 효율적으로 합성할 수 있다. 8kbps의 부호화 조건에서 ACLMS-MPC 방식을 구현하고 SNR를 평가한 결과, ACLMS-MPC의 SNR는 남자음성에서 15.0dB, 여자음성에서 14.3dB 임을 확인할 수 있었다. 따라서 ACLMS-MPC가 기존의 MPC, ACFBD-MPC, LMS-MPC에 비하여 남자음성에서 0.3dB~1.8dB, 여자음성에서 0.3dB~1.6dB 정도 개선된 것을 알 수 있었다. 이러한 방법들은 셀룰러폰이나 인터넷폰과 같이 낮은 비트율의 음원을 사용하여 음성신호를 부호화하는 방식에 활용할 수 있을 것으로 기대된다. 향후 멀티펄스 음원의 진폭과 위치를 동시에 보정하는 6.9kbps 음성부호화 방식의 음질평가를 수행하고자 한다.

Current Status and Future Prospects of High-Power Free Electron Lasers

  • Miginsky, Sergey
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2003년도 제14회 정기총회 및 03년 동계학술발표회
    • /
    • pp.44-44
    • /
    • 2003
  • Free electron lasers (FEL) have, at least, the following advantages in comparison to conventional lasers: FEL can be designed for any arbitrary given emission wavelength. It is continuously tunable within wide band. Easy to get single-mode emission. Easily controlled emission structure (pulse duration, repetition rate, and pulse energy). (omitted)

  • PDF

Use of near-fault pulse-energy for estimating critical structural responses

  • Chang, Zhiwang;Liu, Zhanhui;Chen, Zhenhua;Zhai, Changhai
    • Earthquakes and Structures
    • /
    • 제16권4호
    • /
    • pp.415-423
    • /
    • 2019
  • Near-fault ground motions can impose particularly high seismic demands on structures due to the pulses that are typically observed in the velocity time-histories. In this study it is empirically found that the critical response can be estimated from the directions corresponding to the maximum (max) or minimum (min) pulse-energy. Determination of the pulse-energy requires removing of the high-frequency content. For achieving this, the wavelet analysis and the least-square-fitting (LSF) algorithm are adopted. Results obtained by the two strategies are compared and differences between them are analyzed. Finally, the relationship between the critical response and the response derived from directions having the max or min pulse-energy confirms that using the pulse-energy for deriving the critical response of the building structures is reasonable.

RLS 알고리즘에 기반을 둔 블라인드 채널 추정 (Blind Channel Estimator based on the RLS algorithm)

  • 서우정;하판봉;윤태성
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 추계종합학술대회 논문집
    • /
    • pp.655-658
    • /
    • 1999
  • In this study, We derived Recursive Least Squares(RLS) algorithm with adaptive maximum -likelihood channel estimate for digital pulse amplitude modulated sequence in the presence of intersymbol interference and additive white Gaussian noise. RLS algorithms have better convergence characteristics than conventional algorithms, LMS Least Mean Squares) algorithms.

  • PDF

A Discrete-Amplitude Pulse Width Modulation for a High-Efficiency Linear Power Amplifier

  • Jeon, Young-Sang;Nam, Sang-Wook
    • ETRI Journal
    • /
    • 제33권5호
    • /
    • pp.679-688
    • /
    • 2011
  • A new discrete-amplitude pulse width modulation (DAPWM) scheme for a high-efficiency linear power amplifier is proposed. A radio frequency (RF) input signal is divided into an envelope and a phase modulated carrier. The low-frequency envelope is modulated so that it can be represented by a pulse whose area is proportional to its amplitude. The modulated pulse has at least two different pulse amplitude levels in order that the duty ratios of the pulse are kept large for small input. Then, an RF pulse train is generated by mixing the modulated envelope with the phase modulated carrier. The RF pulse train is amplified by a switching-mode power amplifier, and the original RF input signal is restored by a band pass filter. Because duty ratios of the RF pulse train are kept large in spite of a small input envelope, the DAPWM technique can reduce loss from harmonic components. Furthermore, it reduces filtering efforts required to suppress harmonic components. Simulations show that the overall efficiency of the pulsed power amplifier with DAPWM is about 60.3% for a mobile WiMax signal. This is approximately a 73% increase compared to a pulsed power amplifier with PWM.

Fault Detector and Length Measurement of Electric Cables Based on Frequency Waves

  • Chawporn, Talerngkiat;Chaikla, Amphawan;Sriratana, Witsarut;Trisuwannawat, Thanit
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.45-48
    • /
    • 2003
  • This research presents an approach to simultaneously detect the faults and measure the length of the electric cables. This approach is easy to use and inexpensive. Moreover, it can be applied to any kinds and sizes of the electric cable. This paper uses 750V $4{\times}4$ Sq.mm. cables. The concept is to send the 2 kHz pulse into the electric cable. When the pulse bumps into the fault, it bounces back. Then, the total time the pulse travels back and forth and the shape of the pulse after bumping are inspected using the pulse detector and pulse converter. Next, the signal obtained is modulated with 10 MHz carrier pulse to segregate into several small pulses before sending to 8-bit counter. The length of the electric cable can be obtained using microcontroller and the location of the faults can be seen on the LCD screen. This approach can be used to inspect the electric cables with the length of at least 15 m.

  • PDF

Measurement of Arterial Pulse Wave at the Temple Using PZT Piezo Sensor

  • Kil Se Kee;Han Young Hwan;Lee Eung Hyuk;Park Young Bae;Cho Heung Ho;Min Hong Ki;Hong Seung Hong
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2004년도 학술대회지
    • /
    • pp.772-775
    • /
    • 2004
  • Generally, arterial pulse waves are measured at the radial arterial of wrist or carotid arterial of neck using a sensor such as pressure sensor, piezoelectric sensor or optic sensor. But in this paper, arterial pulse wave is measured at the temple using PZT piezo sensor which is attached on the temple in form of a hair-band. Arterial Pulse waves are generally measured when a reagent is in a static state. But in this paper, we implemented the arterial pulse wave measurement system, as a previous stage of the arterial pulse wave measurement system for running at outdoors or on a running machine, that measures arterial pulse waves at the temple, which is the least moving part when running. Thorough the continuous study, if the motion artifact when running is possible to be removed, the system will be able to perform monitoring of running men's states and especially emergency signals such as serious pulse waves of an/old and feeble persons and handicapped persons.

  • PDF