• Title/Summary/Keyword: Leakage element

Search Result 304, Processing Time 0.023 seconds

A Study of Evaluation Certification on Electronic Power u-IT Convergence Equipment (전력 u-IT 융복합화 기기의 평가와 인증 연구)

  • Yi, Jeong-Hoon;Park, Dea-Woo;Kim, Eung-Sik;Kim, Hong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.11
    • /
    • pp.2433-2440
    • /
    • 2009
  • Whole system and network for supply of electric power and electricity safety are essential element. Electricity safety technology need rating for product and research about certification as product development that is done electric power u-IT cotton flannel mixed with development of u-IT, u-City base technology consists. Study on serve to develop electricity safety integration supervision system to apply product to u-City electric power appliance and cotton flannel mixed of u-IT appliance, Connection badness sensing instrument made device built-in electric power u-IT cotton flannel mixed in outlet that is used most in electric power appliance terminal. Using sensor on ZigBee, RFID performance estimation of communication module about function of product for remote safety check of electricity safety integration supervision system. A performance experiment and estimation in electric leakage, high voltage, Arc, fire detection diagnosis system and certification KS, electricity safety about product that get fitness finding.

Design concept investigation for corner protection of LNG storage tank by ASME section VIII, Div. 2 (ASME section VIII div. 2에 따른 LNG저장탱크 코너프로텍션의 설계개념 고찰)

  • Kim Hyoungsik;Hong Seongho;Seo Heungseok;Yang Youngchul
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.3 s.15
    • /
    • pp.73-79
    • /
    • 2001
  • The corner protection which is consist of insulation and $9\%$ nickel liner is designed to mitigate the high hoop tension at the corner of LNG storage tank by LNG leakage. So the design loads depend on thermal and liquid pressure from leaked LNG In this paper design conditions are suggested as operating, major and minor leak conditions. And in order to check integrity of comer protection for the design conditions by appendix 4 in ASME section VIII div.2, acceptability checking process that have stress categorization and finite element analysis is explained.

  • PDF

Studies on Piston Seal Mechanism of Stirling Engine (스터링 기관의 피스톤 밀봉 기구에 관한 연구)

  • Kim, T.H.
    • Journal of Biosystems Engineering
    • /
    • v.17 no.4
    • /
    • pp.305-313
    • /
    • 1992
  • Dynamic seals have been continue to be one of the major technical problems facing stirling engine designers. Most of the modern engines use some version of the dry ring seal for piston and displacer seals. Friction power losses associated with seals are typically several percent of gross output power, with piston ring seals usually being the main contributor. Much effort has been expended to develop the seal mechanism of piston, but the performance of these seal devices is very poor. This study was conducted to examine the efficiency of the various types of the trial-made piston seal mechanism with reference to leakage of working fluid and friction losses. This paper described the successful hardware implementation of a stainless steel bellows element in stirling engine application with test data in power performance. The indicated power by use of the bellows was more than two times as that by use of the piston ring types. As the result of this study, bellows was provide as a reliable and efficient seal mechanism for any stirling engine application.

  • PDF

Computational Study on the Hemodynamics of the Bypass Shunt Directly Connecting the left Ventricle to a Coronary Artery

  • Shim Eun Bo;Lee Byung Jun;Ko Hyung Jong
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.1158-1168
    • /
    • 2005
  • A shunt from the left ventricle to the left anterior descending artery is being developed for coronary artery occlusive disease, in which the shunt or conduit connects the the left ventricle (LV) with the diseased artery directly at a point distal to the obstruction. To aid in assessing and optimizing its benefit, a computational model of the cardiovascular system was developed and used to explore various design conditions. Computational fluid dynamic analysis for the shunt hemodynamics was also done using a commercial finite element package. Simulation results indicate that in complete left anterior descending artery (LAD) occlusion, flow can be returned to approximately 65% of normal, if the conduit resistance is equal for forward and reverse flow. The net coronary flow can increase to 80% when the backflow resistance is infinite. The increases in flow rate produced by asymmetric flow resistance are enhanced considerably for a partial LAD obstruction, since the primary effect of resistance asymmetry is to prevent leakage back into the ventricle during diastole. Increased arterial compliance has little effect on net flow with a symmetric shunt, but considerably augments it when the resistance is asymmetric. The computational results suggest that an LV-LAD conduit will be beneficial when the resistance due to artery stenosis exceeds 27 PRU, if the resistance is symmetric. Fluid dynamic simulations for the shunt flow show that a recirculating region generated near the junction of the coronary artery with the bypass shunt. The secondary flow is induced at the cutting plane perpendicular to the axis direction and it is in the attenuated of coronary artery.

A Study on the Stress Analysis of Oil Hydraulic Piston Pump with a Swash Plate Type (사판식 유압 피스톤 펌프의 응력해석에 관한 연구)

  • Jeong, Bong-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.4
    • /
    • pp.2424-2429
    • /
    • 2015
  • In an oil hydraulic piston pump, the cylinder block and valve plate in high speed relative sliding motion have the characteristics which should be extremely controlled for the optimization of leakage and friction losses, and pressure-resistance design of them is very important for high pressure performance. But the studies on the stress analysis of those parts have not been performed briskly. Therefore, in this paper, the stress and displacement distributions of the cylinder block and valve plate in the oil hydraulic piston pump with a swash plate type are discussed through the static stress analysis using CATIA V5. The stress and displacement of the cylinder block are more influenced by the axial pressure than by the radial pressure, and are larger by approximately 66% and 30%, respectively. The results show that a review of the material and shape of the valve plate is required.

A New Type of Yagi-Uda Antenna for High Terahertz Output Power (고출력 테라헤르츠파 발생을 위한 새로운 구조의 Yagi-Uda 안테나)

  • Han, Kyung-Ho;Park, Yong-Bae;Kim, Sang-In;Park, Ik-Mo;Lim, Han-Jo;Han, Hae-Wook
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.1
    • /
    • pp.9-14
    • /
    • 2008
  • In this paper, a new type of Yagi-Uda antenna that operates in the terahertz frequencies is designed. The proposed Yagi-Uda antenna can obtain high input resistance of approximately $2000{\Omega}$ at the resonance frequency by using a full-wavelength dipole instead of a half-wavelength dipole as the driver element. The current leakage into the bias line was minimized by applying the photonic bandgap structure to the bias line. By designing the antenna on a thin substrate, the impedance lowering of an antenna caused by the relative dielectric constant of the substrate was prevented and the end-fire radiation pattern which is the original radiation characteristic of the Yagi-Uda antenna could be obtained. We expect that the proposed Yagi-Uda antenna can achieve increased terahertz output power by improving the impedance mismatching problem with the photomixer.

Elastic-plastic Fracture Mechanics Analyses for Burst Pressure Prediction of Through-wall Cracked Tubes (관통균열 세관의 파열압력 예측을 위한 탄소성 파괴역학 해석)

  • Chang Yoon-Suk;Moon Seong-In;Kim Young-Jin;Hwang Seong-Sik;Kim Joung-Soo;Kim Yun-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.10 s.241
    • /
    • pp.1361-1368
    • /
    • 2005
  • The structural and leakage integrity of steam generator tubes should be sustained all postulated loads with appropriate margin even if a crack is present. During the past three decades, for effective integrity evaluation, several limit load solutions have been used world-widely. However, to predict accurately load carrying capacities of specific components under different conditions, the solutions have to be modified by using lots of experimental data. The purpose of this paper is to propose a new burst pressure estimation scheme based on fracture mechanics analyses for steam generator tube with an axial or circumferential through-wall crack. A series of three dimensional elastic-plastic finite element analyses were carried out and, then, closed-form estimation equations with respect to both J-integral and crack opening displacement were derived through reference stress method. The developed engineering equations were utilized for structural integrity evaluation and the resulting data were compared to the corresponding ones fiom experiments as well as limit load solutions. Thereafter, since the effectiveness was proven by promising results, it is believed that the proposed estimation scheme can be used as an efficient tool for integrity evaluation of cracked steam generator tubes.

A New Concept of Magnetic Cable for Safe Mobile Power Delivery (안전한 전력전달을 위한 새로운 형태의 자기케이블)

  • Lee, Woo-Young;Huh, Jin;Choi, Su-Yong;Rim, Chun-Taek
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.542-553
    • /
    • 2011
  • A magnetic cable that can safely deliver high frequency AC electric power in flammable or sensitive workplaces by preventing from arcs and electric shocks is firstly proposed in this paper. Several new magnetic cable structures with magnetic shields, which are composed of such cancel coil, cancel copper plate, and cancel copper pipe, were compactly implemented by considering and analyzing fringe field and thus the parallel leakage flux is drastically reduced. The output power and efficiency of a prototype magnetic cable with 1.5 m length and 5 cm gap were measured as 353.8W and 68%, where the source current and switching frequency were 10 $A_{rms}$ and 20 kHz, respectively. The proposed magnetic cables are fully analyzed and verified by finite-element method (FEM) simulations and experiments. The results are in a good agreement.

Performance Evaluation of a Connection Joint using a High-Ductility Concrete (고인성 콘크리트를 사용한 연결조인트의 성능평가)

  • Kim, Byeong-Ki;Kim, Jae Hwan;Yang, Il-Seung;Lee, Sang-Soo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.15 no.2
    • /
    • pp.185-192
    • /
    • 2015
  • Expansion joint is the essential element of the bridge in many cases. When the bridge faces chloride of preventing freezing on the surface of the bridge, the expansion joints is damaged significantly, thus this reduces service life and increases maintenance cost of the bridge. As a solution of this problem, new technology using high ductile materials for the joint without expansion joint was developed and in this research, crack control performance, preventing leaking after the cracking, and chloride resistance were experimentally evaluated. As a result of the experiment, with PCM and FRC materials, the connecting joint suffered poor crack dispersion and severe damage by the chloride penetration while with high-ductile material, the connecting joint dispersed the tensile deformation to microcracks stably up to 7.5mm. Furthermore, under the sever conditions, the leaking was prevented and penetration of chloride ions was prevented after the crack occurred.

Dynamic response of a base-isolated CRLSS with baffle

  • Cheng, Xuansheng;Liu, Bo;Cao, Liangliang;Yu, Dongpo;Feng, Huan
    • Structural Engineering and Mechanics
    • /
    • v.66 no.3
    • /
    • pp.411-421
    • /
    • 2018
  • Although a rubber isolation cushion can reduce the dynamic response of a structure itself, it has little influence on the height of a sloshing wave and even may induce magnification action. Vertical baffles are set into a base-isolated Concrete Rectangular Liquid Storage Structure (CRLSS), and baffles are opened as holes to increase the energy dissipation of the damping. Problems of liquid nonlinear motion caused by baffles are described using the Navier-Stokes equation, and the space model of CRLSS is established considering the Fluid-Solid Interaction (FSI) based on the Finite Element Method (FEM). The dynamic response of an isolated CRLSS with various baffles under an earthquake is analyzed, and the results are compared. The results show that when the baffle number is certain, the greater the number of holes in baffles, the worse the damping effects; when a single baffle with holes is set in juxtaposition and double baffles with holes are formed, although some of the dynamic response will slightly increase, the wallboard strain and the height of the sloshing wave evidently decrease. A configuration with fewer holes in the baffles and a greater number of baffles is more helpful to prevent the occurrence of two failure modes: wallboard leakage and excessive sloshing height.