• 제목/요약/키워드: Leakage correction

검색결과 62건 처리시간 0.029초

고주파 공진현상을 이용한 CW CO2 레이저의 출력리플 최소화 (Minimization of a CW CO2 Laser Output Ripple by using High Frequency Resonance Phenomena)

  • 사쿠라;권민재;김희제;이동길;허국성
    • 전기학회논문지
    • /
    • 제62권6호
    • /
    • pp.798-802
    • /
    • 2013
  • In a conventional DC power supply used for CO2 laser, the circuit elements such as a rectifier bridge, a current-limiting resistor, a high voltage switch, energy storage capacitors ans a high-voltage isolation transformer using high turn ratio are necessary. Consequently, those supplies are expensive and require a large space. Thus, laser resonator and power supply should be optimally designed. In this paper, we propose a new power supply using high frequency resonance phenomena for CW(Continuous wave) CO2 laser (maximum output of 23W with discharge length of 450mm). It consists of a transformer including leakage inductance, magnetizing inductance and half-bridge converter, a three-stage Cockcroft-Walton and PFC(Power factor correction) circuit. The output ripple voltage can be controlled the minimum of 0.24% under the high frequency switching of 231kHz. Furthermore, the output efficiency was improved to 16.4% and the laser output stability of about 5.6% was obtained in this laser system.

현장 중심의 화학테러·사고 대응을 위한 피해 영향 범위 평가 개선 방안 연구 (A Study on Improvement of Damage Impact Range Assessment for Field-Based Response Against Chemical Terrorism and Accidents)

  • 이덕재;송창근
    • 융합정보논문지
    • /
    • 제10권8호
    • /
    • pp.127-136
    • /
    • 2020
  • 화학물질을 이용한 화학테러·사고는 국내·외에서 지속해서 발생, 시도되는 추세이다. 국내의 경우, 환경부 화학물질안전원에서 CARIS(Ver. 2018)를 화학테러·사고 발생지역의 피해 영향 범위 평가 용도로 제공하여 현장 대응에 활용하고 있다. 하지만 현행 CARIS는 실내, 지하 등과 같은 폐쇄된 공간에 대한 영향을 고려하지 못하여 현장에서 요구하는 정밀한 피해 영향 범위 평가 결과를 제공하는데 어려우며 제공되는 정보도 제한적이다. 본 연구에서는 CARIS(Ver. 2018)를 구동하여 획득한 피해 영향 범위 평가 결과와 국내·외 문헌 자료를 비교, 검토하여 제한사항과 개선 방향을 제시하였다. 또한 지하, 실내 등 특수 지점, 지역에 대한 구동 모델 구축의 필요성과 현장 대응 요원 등 포함한 주민에게 제공되는 정보의 방향성을 제안하였다. CARIS의 보완과 수정에 있어 본 연구에서 제안한 방법이 반영된다면 더욱 진보된 화학테러·사고 현장 대응 역량 체계 구축이 될 것으로 기대한다.

LED 조명장치 구동용 200[W]급 하프브리지 LLC 직렬공진형 컨버터 (200[W] Half-Bridge LLC Series Resonant Converter for driving LED Lamp)

  • 한우용;박효식
    • 한국산학기술학회논문지
    • /
    • 제11권11호
    • /
    • pp.4483-4488
    • /
    • 2010
  • LED는 다른 광원에 비해 동작수명이 길고, 친환경적이며, 에너지 효율이 높은 장점을 가지고 있다. 최근 LED 기술의 발전으로 인해 고휘도, 고용량의 LED가 개발됨에 따라, 표시장치에만 적용되던 LED를 조명장치에도 적용하는 기술이 확산되고 있다. 파워 LED는 동작의 안정성 및 신뢰성을 확보하기 위해 구동전류를 일정한 값 이하로 유지하는 전류제한기능이 필요한데, 본 논문에서는 전류제한기능을 포함한 하프브리지 LLC 직렬공진형 컨버터를 제안한다. 하프브리지 LLC 직렬공진형 컨버터는 다른 공진형 컨버터에 비해 상대적으로 입력전압 및 출력부하 범위가 광범위한 장점이 있으며, 변압기의 누설인덕턴스를 공진인덕터로 이용할 수 있기 때문에 마그네틱 소자를 줄일 수 있는 장점이 있다. 전류제한기능 및 역률개선기능을 포함하고 있는 출력전압 DC24[V], 200[W]급의 LED 조명장치 구동용 하프브리지 LLC 직렬공진형 컨버터의 설계 및 실험을 통해 타당성을 입증하였다.

스테레오 감마선 탐지장치를 이용한 감마선원 분포측정 시스템에 관한 연구 (The Study Image Aquisition System for Radiation Source Using the Stereo Gamma-ray Detector)

  • 황영관;이남호;이승민
    • 전자공학회논문지
    • /
    • 제52권4호
    • /
    • pp.197-203
    • /
    • 2015
  • 전 세계적으로 전력생산을 위해 원전 증설이 지속적으로 증가하고 있으며 이에 따라 노후 원전에 대한 해체 및 원전사고에 대한 관심이 증가하고 있다. 원전 사고 시 발생되는 감마선원의 누출은 신속하고 정확한 탐지해야 그 피해를 최소화 시킬 수 있다. 기 개발된 장비는 선원에 대한 방향정보만을 나타내고 있어 정확한 공간상의 분포를 알 수 없다. 본 논문에서 개발한 스테레오 감마선탐지장치는 누출된 감마선원에 대한 분포를 측정할 수 있도록 구현하고 거리탐지를 위한 알고리즘을 적용하였다. 거리탐지를 위하여 스테레오 보정을 LED광과 보정패턴을 사용하여 진행하였고, LED 광원과 감마선원을 대상으로 성능시험을 진행하였다. 성능시험 결과 두 실험에서 5%이하의 오차를 갖게 됨을 확인하였다. 본 논문의 결과는 향후 고속 경량화 된 감마선 영상화 장치 개발을 위한 자료로 활용될 것이다.

Sealing capability and marginal fit of titanium versus zirconia abutments with different connection designs

  • Sen, Nazmiye;Sermet, Ibrahim Bulent;Gurler, Nezahat
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권2호
    • /
    • pp.105-111
    • /
    • 2019
  • PURPOSE. Limited data is available regarding the differences for possible microleakage problems and fitting accuracy of zirconia versus titanium abutments with various connection designs. The purpose of this in vitro study was to investigate the effect of connection design and abutment material on the sealing capability and fitting accuracy of abutments. MATERIALS AND METHODS. A total of 42 abutments with different connection designs [internal conical (IC), internal tri-channel (IT), and external hexagonal (EH)] and abutment materials [titanium (Ti) and zirconia (Zr)] were evaluated. The inner parts of implants were inoculated with $0.7{\mu}L$ of polymicrobial culture (P. gingivalis, T. forsythia, T. denticola and F. nucleatum) and connected with their respective abutments under sterile conditions. The penetration of bacteria into the surrounding media was assessed by the visual evaluation of turbidity at each time point and the number of colony forming units (CFUs) was counted. The marginal gap at the implant- abutment interface (IAI) was measured by scanning electron microscope. The data sets were statistically analyzed using Kruskal-Wallis followed by Mann-Whitney U tests with the Bonferroni-Holm correction (${\alpha}=.05$). RESULTS. Statistically significant difference was found among the groups based on the results of leaked colonies (P<.05). The EH-Ti group characterized by an external hexagonal connection were less resistant to bacterial leakage than the groups EH-Zr, IT-Zr, IT-Ti, IC-Zr, and IC-Ti (P<.05). The marginal misfit (in ${\mu}m$) of the groups were in the range of 2.7-4.0 (IC-Zr), 1.8-5.3 (IC-Ti), 6.5-17.1 (IT-Zr), 5.4-12.0 (IT-Ti), 16.8-22.7 (EH-Zr), and 10.3-15.4 (EH-Ti). CONCLUSION. The sealing capability and marginal fit of abutments were affected by the type of abutment material and connection design.

선박용 디젤엔진의 출력산정을 위한 TDC 위치보정에 관한 연구 (Correction of TDC Position for Engine Output Measuring in Marine Diesel Engines)

  • 정균식;최준영;정은석;최재성
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권4호
    • /
    • pp.459-466
    • /
    • 2012
  • 엔진성능 분석을 위해서는 기관의 정확한 출력이 기본적으로 중요한 인자이며, 또한 오늘날 엔진의 연소압력 분석 장치는 엔진의 연구와 개발, 환경규제 및 엔진의 유지관리를 위해서 필수 장비로 대두 되고 있다. 디젤엔진에서 성능 분석의 정확도는 TDC의 위치를 정확하게 찾는 것이 무엇보다 중요하다. 따라서 본 연구에서는 2행정 대형저속의 선박엔진에서 TDC의 위치에 영향을 주는 인자들의 영향을 조사 분석하고, 정확한 TDC 위치를 파악하기 위한 새로운 방법을 제시하고자 한다. 전보에서 정확한 엔진 출력은 TDC위치의 정확도에 의해서 결정이 되며, '시간기준 계측' 방법 보다 '각도기준 계측' 방법이 정확도 측면에서 우수함을 밝혔다. 또한 압축압력의 피크는 열손실 및 Blow by에 의한 가스누설로 실제 TDC와 차이가 발생하는 손실각(Loss of angle)을 확인하였으며, 이를 이용하여 정확한 출력을 측정할 수 있는 '향상된 시간기준' 방법을 고안하였다. 이 방법은 선박의 주기관의 손실각만 보정함으로써 엔코더가 설치된 실린더의 '각도기준 계측' 방법과 같은 결과를 얻을 수 있음을 확인하였다. 따라서 본 연구에서는 정확한 엔진출력의 새로운 계측 방법을 제시하고, 그 결과에 대한 신뢰성을 검증 하고자 한다.

GaN HEMT Based High Power and High Efficiency Doherty Amplifiers with Digital Pre-Distortion Correction for WiBro Applications

  • Park, Jun-Chul;Kim, Dong-Su;Yoo, Chan-Sei;Lee, Woo-Sung;Yook, Jong-Gwan;Chun, Sang-Hyun;Kim, Jong-Heon;Hahn, Cheol-Koo
    • Journal of electromagnetic engineering and science
    • /
    • 제11권1호
    • /
    • pp.16-26
    • /
    • 2011
  • This paper presents high power and high efficiency Doherty amplifiers for 2.345 GHz wireless broadband (WiBro) applications that use a Nitronex 125-W ($P_{3dB}$) GaN high electron mobility transistor (HEMT). Two- and three-way Doherty amplifiers and a saturated Doherty amplifier using Class-F circuitry are implemented. The measured result for a center frequency of 2.345 GHz shows that the two-way Doherty amplifier attains a high $P_{3dB}$ of 51.5 dBm, a gain of 12.5 dB, and a power-added efficiency (PAE) improvement of about 16 % compared to a single class AB amplifier at 6-dB back-off power region from $P_{3dB}$. For a WiBro OFDMA signal, the Doherty amplifier provides an adjacent channel leakage ratio (ACLR) at 4.77 MHz offset that is -33 dBc at an output power of 42 dBm, which is a 9.5 dB back-off power region from $P_{3dB}$. By employing a digital pre-distortion (DPD) technique, the ACLR of the Doherty amplifier is improved from -33 dBc to -48 dBc. The measured result for the same frequency shows that the three-way Doherty amplifier, which has a $P_{3dB}$ of 53.16 dBm and a gain of 10.3 dB, and the saturated Doherty amplifier, which has a $P_{3dB}$ of 51.1 dBm and a gain of 10.3 dB, provide a PAE improvement of 11 % at the 9-dB back-off power region and 7.5 % at the 6-dB back-off region, respectively, compared to the two-way Doherty amplifier.

보건의료정보의 법적 보호와 열람.교부 (A Study on Legal Protection, Inspection and Delivery of the Copies of Health & Medical Data)

  • 정용엽
    • 의료법학
    • /
    • 제13권1호
    • /
    • pp.359-395
    • /
    • 2012
  • In a broad term, health and medical data means all patient information that has been generated or circulated in government health and medical policies, such as medical research and public health, and all sorts of health and medical fields as well as patients' personal data, referred as medical data (filled out as medical record forms) by medical institutions. The kinds of health and medical data in medical records are prescribed by Articles on required medical data and the terms of recordkeeping in the Enforcement Decree of the Medical Service Act. As EMR, OCS, LIS, telemedicine and u-health emerges, sharing and protecting digital health and medical data is at issue in these days. At medical institutions, health and medical data, such as medical records, is classified as "sensitive information" and thus is protected strictly. However, due to the circulative property of information, health and medical data can be public as well as being private. The legal grounds of health and medical data as such are based on the right to informational self-determination, which is one of the fundamental rights derived from the Constitution. In there, patients' rights to refuse the collection of information, to control recordkeeping (to demand access, correction or deletion) and to control using and sharing of information are rooted. In any processing of health and medical data, such as generating, recording, storing, using or disposing, privacy can be violated in many ways, including the leakage, forgery, falsification or abuse of information. That is why laws, such as the Medical Service Act and the Personal Data Protection Law, and the Guideline for Protection of Personal Data at Medical Institutions (by the Ministry of Health and Welfare) provide for technical, physical, administrative and legal safeguards on those who handle personal data (health and medical information-processing personnel and medical institutions). The Personal Data Protection Law provides for the collection, use and sharing of personal data, and the regulation thereon, the disposal of information, the means of receiving consent, and the regulation of processing of personal data. On the contrary, health and medical data can be inspected or delivered of the copies, based on the principle of restriction on fundamental rights prescribed by the Constitution. For instance, Article 21(Access to Record) of the Medical Service Act, and the Personal Data Protection Law prescribe self-disclosure, the release of information by family members or by laws, the exchange of medical data due to patient transfer, the secondary use of medical data, such as medical research, and the release of information and the release of information required by the Personal Data Protection Law.

  • PDF

단안에 국소적으로 발현된 색소정맥옆망막맥락막 위축 1예 (A Case of Unilateral Focal Pigmented Paravenous Retinochoroidal Atrophy)

  • 박효송;양종윤;박현주
    • 대한안과학회지
    • /
    • 제59권12호
    • /
    • pp.1190-1194
    • /
    • 2018
  • 목적: 단안에 국소적으로 발생한 색소정맥옆망막맥락막 위축(pigmented paravenous retinochoroidal atrophy) 1예를 경험하여 이를 보고하고자 한다. 증례요약: 46세 여자 환자가 건강검진상에서 발견된 우안 망막 이상 소견으로 내원하였다. 나안시력은 양안 모두 1.0이었다. 세극등현미경으로 시행한 전안부 검사상 특이 이상 소견은 관찰되지 않았다. 안저검사상 우안의 상측 망막정맥을 따라 국소적으로 분포된 뼈 조각 모양의 색소침착이 동반된 망막맥락막위축 소견이 관찰되었다. 안저자가형광상 우안의 망막맥락막위축의 경계에서 다소 과형광을 보이면서 병변의 대부분은 저형광 소견을 보였다. 빛간섭단층촬영상 해당 병변은 망막색소상피층의 위축 및 뭉침이 혼재되어 있었고, 맥락막층에서 맥락막모세혈관층이 얇아진 소견을 보였다. 형광안저촬영상 병변 내 창문비침 및 형광차단이 혼재되어 관찰되었으며 이는 망막색소상피층의 위축 및 뭉침 부위와 일치하였다. 결론: 단안에 국소적으로 발생한 색소정맥옆망막맥락막 위축 1예를 경험하여 이를 국내 최초로 보고하는 바이다.

교육행정정보시스템의 보안성 강화를 위한 하이브리드 블록체인 설계 (Hybrid Blockchain Design to Improve the Security of Education Administration Information System)

  • 손기봉;손민영;김영학
    • 한국콘텐츠학회논문지
    • /
    • 제21권6호
    • /
    • pp.1-11
    • /
    • 2021
  • 나이스 시스템은 우리나라의 초·중등학교에서 운영되던 행정 정보를 통합한 시스템이다. 현재 이 시스템은 중앙 서버 방식으로 운영되고 있고 학교 행정 정보와 학생의 중요 교육 정보를 포함하고 있다. 학생 정보 중학생생활기록부는 학생이 상급 기관으로 진학하기 위한 중요한 정보를 포함하고 있지만, 악의적인 공격에 정보가 유출되거나 조작되는 등의 문제가 발생할 수 있다. 본 논문에서는 기존 나이스 시스템에서 관리하던 서버와 블록체인 기술을 접목한 하이브리드 블록체인 시스템을 제안한다. 제안된 시스템은 학생 정보의 접근 시 데이터베이스의 쿼리 정보를 블록에 기록한다. 학생의 정보 수정이나 증명서 발급 등의 요청이 오면 블록체인의 쿼리와 데이터베이스의 정보, 학생의 키값을 확인하여 정보의 유출이나 조작 여부 등을 판단하고 정상 데이터일 경우에만 기록 수정 등의 요청을 수행한다. 이러한 과정은 블록체인을 통해 데이터 조작 등을 검사하기 때문에 기존 중앙 서버보다 보안이 향상된다. 제안된 시스템은 이더리움 플랫폼에서 구현되었으며 스마트 컨트랙트를 사용하여 블록체인의 쿼리 정보를 실험적으로 확인하였다. 본 연구는 기존의 나이스 시스템에 블록체인을 결합하여 학생 자료의 위변조에 대한 보안을 강화하여 나이스 시스템의 신뢰도를 높이는 데 기여한다.