• Title/Summary/Keyword: Leakage characteristics

Search Result 1,653, Processing Time 0.026 seconds

Analysis of leakage factors affecting ECV performance in variable compressor

  • Mahmud, Md. Iqbal;Cho, Haeng Muk
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.183-188
    • /
    • 2014
  • Solenoid operated electromagnetic control valve (ECV) using in an external variable displacement swash plate type compressor is widely used for air conditioning control system because of its low energy consumption and high efficient characteristics. ECV controls the entire vehicle air conditioning system by means of a pulse width modulation (PWM) system that supplied from an external controller. Different pressure ports located within ECV has important functions to control the air/refrigerant flow through its internal passages. The flow paths are preciously maintained with acceptable ranges of leakage (gap) between the parts inside it which is followed by effective design and critical dimensioning of its internal features. Therefore, it saves energy losses from the solenoid operation as well as ensures the balance of forces within it. The research paper highlights analysis of the leakages (at different pressure ports) and dimensioning tolerance factors that affects the ECV performance.

Characteristics of Ta2O5 thin film prepared by RTMOCVD (RTMOCVD법에 의해 제조된 Ta2O5 박막의 특성)

  • So, Myoung-Gi;Kwong, Dim Lee
    • Journal of Industrial Technology
    • /
    • v.19
    • /
    • pp.101-105
    • /
    • 1999
  • Ultra thin $Ta_2O_5$ gate dielectrics were prepared by RTMOCVD (rapid thermal metal organic chemical vapor deposition) using Ta source $TaC_{12}H_{30}O_5N$ and $O_2$ gaseous mixtures. As a result, $Ta_2O_5$ thin films showed significantly low leakage current compared to $SiO_2$ of identical thickness, which was due to the stabilization of the interfacial layer by NO ($SiO_xN_y$) passivation layer. The conduction of leakage current in $Ta_2O_5$ thin films was described by the hopping mechanism of Poole-Frenkel (PF) type.

  • PDF

The effect of axial displacement of the impeller on the performance and axial thrust of a pump (회전차의 축방향 변위가 펌프의 성능과 축추력에 미치는 영향)

  • Hong, Sun-Sam;Gang, Sin-Hyeong;Orachelashvili, B.
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.4
    • /
    • pp.562-569
    • /
    • 1997
  • The axial position of an impeller is misaligned in the process of manufacturing and assembling. For a single suction centrifugal pump with balancing holes, the effect of axial displacement of impeller on the performance, leakage loss and axial thrust acting on the impeller is experimentally investigated. The axial displacement decreases the pump efficiency, increases the leakage through the clearance between wearing ring and impeller, and affects the characteristics of axial thrust.

Effect of heat Leak on Cycle Characteristics of Refrigerator (냉장고 사이클 특성에 미치는 열손실량의 영향)

  • 신진규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.6
    • /
    • pp.871-879
    • /
    • 1998
  • The refrigerator consists of many components such as compressor condenser expansion valve evaporator and the cabinet which filled by urethane foam. In this paper the heat leakage of refriger-ator is measured by the new experiment method which is different from a present method, The devi-ation of the UA(overall heat transfer coefficient times area) between the simulation and experiments is about 7-8%. Using the modeling of various components of refrigeration system a performance analysos of CFC 12 and HFC 134a is performed numerically on the UA. As the results of this study according to increase the heat leakage the refrigeration load and mass flow rate of refrigerant are increased. And the increase of the mass flow rate results in the increase of the condensing and evapo-rating temperature. Therefore according to increase of the heat leakage the COP leads to increase because the increase of refrigeration capacity is larger than the increase if compressor power.

  • PDF

Leakage and Rotordynamic Analysis for Staggered-Labyrinth Gas Seal (엇갈린 래버린스 실의 누설량 및 동특성 해석)

  • Ha, Tae-Woong
    • Tribology and Lubricants
    • /
    • v.18 no.1
    • /
    • pp.24-33
    • /
    • 2002
  • The basic equations are derived for the analysis of a staggered labyrinth gas seal which are generally used in high performance compressors and steam turbines. The Bulk-flow is assumed for a single cavity control volume and the flow is assumed to be completely turbulent in circumferential direction. Moody's wall-friction-factor formula is used for the calculation of wall shear stresses in the single cavity control volume. For the reaction force developed by the seal, linearized zeroth-order and first-order perturbation equations are developed for small motion about a centered position. Integration of the resultant first-order pressure distribution along and around the seal defines the rotordynamic coefficients of the staggered labyrinth gas seal. Theoretical results of leakage and rotordynamic characteristics for the staggered labyrinth gas seal are compared with those of the plain seal and see-through labyrinth seal.

A Study on te Dynamic Behavior of a Scroll Compressor Considering Tangential Leakage (접선방향의 누설을 고려한 스크롤 압축기의 동적 거동에 관한 연구)

  • 김태종;한동철
    • Tribology and Lubricants
    • /
    • v.12 no.2
    • /
    • pp.20-31
    • /
    • 1996
  • Pressures in compression pockets consists of two identical spiral scrolls are influenced by gas flow resistance in discharge process and leakages in radial and tangential directions between two scroll wraps. In this paper, considering geometrical characteristics of these members, flow resistance and refrigerant gas leakage losses, pressure variations in compression pockets are calculated. For a scroll compressor model with fixed crank mechanism, acting load on crankshaft is analyzed. And, for a vertical type crankshaft-journal bearing system used in scroll compressor, nonlinear transient response is calculated including nonlinear fluid film reaction forces of journal bearings.

Durability Properties of Liquid Phase LPG Injection System with Various Qualities of LPG Fuels (LPG연료품질에 따른 LPG액상분사방식의 내구특성연구)

  • 김창업;오승묵;강건용
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.5
    • /
    • pp.73-78
    • /
    • 2004
  • The liquid phase LPG injection (LPLi) system (the third generation technology) has been considered as one of the next generation fuel supply systems for LPG vehicles, since it has a very strong potential to accomplish the higher power, higher efficiency, and lower emission characteristics than the mixer type(the second generation technology) fuel supply system. To investigate the durability property of core part of injector in liquid phase LPG injection system, leakage test, SEM test of injectors and analysis of unvaporized fuel components with various LPG fuel qualities were tested. The experimental results showed that no serious problem in durability test using favorable LPG fuel quality, while high leakage amount due to the large scratches in the needle and nozzle of the injector were found using LPG fuel with highly containing olefin components, especially butadiene species.

Fractal Analysis of the Surface in Thin Film Capacitors

  • Hong, Kyung-Jin;Min, Yong-Ki;Cho, Jae-Cheol
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.11C no.2
    • /
    • pp.18-22
    • /
    • 2001
  • The thin films of high permitivity in ferroelectric materials using a capacitor are applied to DRAMs and FRAMs. (Ba, Sr)TiO$_3$ thin as ferroelectric materials were prepared by the sol-gel method and made by spin-coating on the Pt/Sio$_2$/Si substrate at 4,000 [rpm] for 10 seconds. The structural characteristics of the surface were analyzed by fractal dimension. The thickness of BST ceramics thin films was about 260∼280 [nm]. The property of the leakage current was stable with 10-9∼10-11[A] when the applied voltage was 0∼3[V]. BST thin films ha low leakage current properties when fractal dimension was low and a coating area was high.

Fabrication of High Voltage a-Si:H TFT Plasma Chemical Vapor Deposition (플라즈마 CVD에 의한 고전압 비정질 실리콘 박막 트랜지스터의 제작)

  • Lee, Woo-Sun;Kang, Young-Chul;Kim, Hyung-Gon
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.2
    • /
    • pp.312-317
    • /
    • 1994
  • We studied the fabrication and electrical characteristics of high voltage hydrogenerated amorphous silicon thin film transistor using plasma enchanced chemical vapor deposition(PECVD). The device shows 2500${\AA}$ SiOS12T, 400-1500${\AA}$ a-Si tickness, 350V output voltage and 9.55${\times}$10S04T average on/off current ratio. We found that the leakage current of high voltage TFT occurred 0-70V drain voltage. As the leakage current depend on the a-Si thickness, the leakage current of high voltage TFT decreased by reduction of the a-Si thickness.

The Effect of the Non Soluble Industrial Dust on the Electrical Properties of Distribution Porcelain Suspension Insulators (비용해성 산업용 분진이 배전용 자기제 현수애자의 전기적 특성에 미치는 영향)

  • Kim, Chan-Young;Song, Il-Keun;Kim, Ju-Yong;Han, Jae-Hong;Kim, Dong-Myung;Lee, Byung-Sung
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.4
    • /
    • pp.182-189
    • /
    • 2001
  • In this paper, the distribution suspension porecelain insulators which had been used for long periods in the contaminated area were evaluated. The contaminated area is close to the sea and in the high density of industries. The heavily contaminated domestic and imported insulators were investigated by using electrical characteristics, such as power-frequency dry flashover voltage, power-frequency wet, flahover voltage, and leakage current. Also, these electrical results were compared with the contaminants on the surface. From these analysis, we found that the contamination from the industrial dust, only slightly decreased flashover voltage and increased leakage current. Therefore, the electrical properties of insulators used for 30 years in the area of coast and industrial complex were not much changed.

  • PDF