• Title/Summary/Keyword: Leakage characteristics

Search Result 1,642, Processing Time 0.035 seconds

The Oxide Characteristics in Flash EEPROM Applications (플래시 EEPROM 응용을 위한 산화막 특성)

  • 강창수;김동진;강기성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.855-858
    • /
    • 2001
  • The stress induced leakage currents of thin silicon oxides is investigated in the VLSI implementation of a self learning neural network integrated circuits using a linearity synapse transistor. The channel current for the thickness dependence of stress current, transient current, and stress induced leakage currents has been measured in oxides with thicknesses between 41 ${\AA}$, 86${\AA}$, which have the channel width ${\times}$ length 10 ${\times}$1${\mu}$m, 10 ${\times}$0.3${\mu}$m respectively. The stress induced leakage currents will affect data retention in synapse transistors and the stress current, transient current is used to estimate to fundamental limitations on oxide thicknesses. The synapse transistor made by thin silicon oxides has represented the neural states and the manipulation which gaves unipolar weights. The weight value of synapse transistor was caused by the bias conditions. Excitatory state and inhitory state according to weighted values affected the channel current. The stress induced leakage currents affected excitatory state and inhitory state.

  • PDF

Current Characteristics in the Silicon Oxides (실리콘 산화막의 전류 특성)

  • Kang, C.S.;Lee, Jae Hak
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.10
    • /
    • pp.595-600
    • /
    • 2016
  • In this paper, the oxide currents of thin silicon oxides is investigated. The oxide currents associated with the on time of applied voltage were used to measure the distribution of voltage stress induced traps in thin silicon oxide films. The stress induced leakage currents were due to the charging and discharging of traps generated by stress voltage in the silicon oxides. The stress induced leakage current will affect data retention in memory devices. The oxide current for the thickness dependence of stress current and stress induced leakage currents has been measured in oxides with thicknesses between $109{\AA}$, $190{\AA}$, $387{\AA}$, and $818{\AA}$ which have the gate area $10^{-3}cm^2$. The oxide currents will affect data retention and the stress current, stress induced leakage current is used to estimate to fundamental limitations on oxide thicknesses.

Measurement of Thermal Load in the Tip-Clearance Region of a Rotor Surface (팁간극 영역에서의 동익 표면 열부하 측정)

  • Lee, Sang-Woo;Kwon, Hyun-Goo;Park, Jin-Jae
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.187-192
    • /
    • 2003
  • The heat (mass) transfer characteristics in the tip-leakage flow region of a high-turning first-stage turbine rotor blade has been investigated by employing the naphthalene sublimation technique. The heat transfer data in the tip-leakage flow area for the tip clearance-to-span ratio, h/s, of 2.0% are compared with those in endwall three-dimensional flow region without tip clearance (h/s = 0.0 %). The result shows that the thermal load in the tip-leakage flow region for h/s = 2.0% is more severe than that in the endwall flow region for h/s = 0.0%. The thermal loads even at the leading and trailing edges for h/s = 2.0% are found larger than those for h/s = 0.0%. The tip-leakage flow results in heat transfer augmentations near the tip on both pressure and suction sides in comparison with the mid-span results.

  • PDF

The Evaluation of Ageing Characteristics of Silicone Rubber for Outdoor by Leakage Current Monitoring (누설전류 모니터링에 의한 옥외용 실리콘 고무의 열화 특성 평가)

  • Kim, J.H.;Seo, K.S.;Moon, J.S.;Yang, G.J.;Cho, H.G.;Park, Y.G.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2408-2410
    • /
    • 1999
  • The ageing process was checked by leakage current monitoring in Inclined-Plane Method. In order to monitor leakage current, DAS with 12-bit, 8-channel A/D converter was prepared. The monitored components of leakage current were averages of the rms and peak, max peak, cumulative charge, and the number of peaks in the ranges of 1-10, 10-20, 20-30, 30-40, 40-50, >50 mA. And, erosion depth was measured to be used as the index of the ageing. So, the results of leakage current components and erosion depth measurement were compared to find one or more components of which trends of changes were similar to that of erosion.

  • PDF

Leakage Prevention of Mechanical Seal in a Feed Water Pumpof Power Plant with Oxygen Water Treatment (산소주입 수처리 발전소용 급수펌프 밀봉장치의 누설방지)

  • Shin, Jung-Gook;Moon, Seung-Jae;Yoo, Hoseon
    • Plant Journal
    • /
    • v.7 no.1
    • /
    • pp.56-63
    • /
    • 2011
  • The identifying cause of leakage problems on mechanical seal in a feed water pump of power plant have been difficult because of technical limits of domestic mechanical seal manufacturer and the various conditions of power plants. This paper can get a conclusion through the consideration study and experiment test of mechanical seal characteristics of feed water pump depending on oxygen treatment as follows. The oxygen treatment increase dissolved oxygen and cause a corrosion on the mechanical seal stationary ring composed of antimony as well as leakage problems. For solving leakage problems of seal, to eliminate dissolved oxygen in the cooling water of seal with hydrazine injection can prevent leakage problems of mechanical seal in feed water pump.

  • PDF

Performance Characteristics of Side Channel Type Regenerative Pumps (사이드채널형 재생펌프의 성능 특성에 관한 실험적 연구)

  • Kang Shin-Hyoung;Lim Hyung-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.3 s.234
    • /
    • pp.306-313
    • /
    • 2005
  • The performance of a regenerative pump is affected by many parameters, especially blade shape of impeller, leakage flow in the clearance and head losses at the inlet & outlet. An impeller with J-shape blade was designed and 5 times scale up model was tested at similarity conditions to evaluate the performance. Performance variations with clearance change were executed. The amounts of leakage flow through the clearance were estimated using the one-dimensional leakage flow models and analysis. Main leakage flow is generated through the gap between the impeller and casing. The inlet & outlet head losses were also estimated. Such corrections are very important to evaluate the final performance of the impeller and pump. Cavitation test was also performed at 1,200 rpm. NPSH of the regenerative pump was obtained and growth of cavity within blades was visualized.

Standard Manual for the Diagnosis and Repairing Leakage Cracks of Underground Structures in Apartment Housing - Maintenance Diagnosis - (공동주택 부위별 표준 누수 진단 매뉴얼 - 유지관리 진단 -)

  • Kim, Soo Yeon;Lee, Jung Hun;Lee, Sung Jin;Jang, Duk Bae;Oh, Sang Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.191-192
    • /
    • 2018
  • This study presents the standard methods of diagnosis and repair to prevent and maintain the durability degradation caused by leakage cracks in underground structures in Korea. The third part after the announcement of the existing maintenance plan, The environmental characteristics and leakage condition of underground structures, the causes of deterioration of underground concrete structures, and countermeasures and leakage equipment were described.

  • PDF

Temperature dependent characteristics of leakage currents of ZnO blocks (온도에 따른 ZnO 피뢰기 소자의 누설전류의 온도의존성)

  • Lee, Bok-Hee;Lee, Su-Bong;Li, Feng;Kim, Dong-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1572-1573
    • /
    • 2006
  • This paper presents electrical properties of Zinc Oxide(ZnO) surge arrester blocks under the power frequency AC voltages and various temperatures. The leakage current, $I_{R}-V$ curios and power dissipation for the fine and aged ZnO surge arrester blocks were measured as a function of the temperatures and applied voltages. When the temperature is increased from $50\;[^{\circ}C]$ to $150\;[^{\circ}C]$, the total leakage current significantly increased at the sane applied voltage level. Also, the resistive leakage currents and power dissipation were increased with increasing temperature. The leakage current and power dissipation of the aged ZnO arrester blocks were higher than the fine ZnO arrester blocks.

  • PDF

A Leakage Current Analysis of EHV Porcelain Insulators by Artificial Contamination Method (초고압 송전용 자기애자의 인공오손법을 통한 누설전류 분석)

  • Choi, In-Hyuk;Choi, Jang-Hyun;Jung, Yoon-Hwan;Lee, Dong-Il
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.65-68
    • /
    • 2004
  • This paper researched leakage current characteristics of artificially contaminated EHV insulators through construction of long-term testing facility. Insulators were contaminated and classified into the ESDD contaminated levels under IEC standards method. As the test results of contaminated insulators was carried out several experiments, leakage current greatly increased during initial rainfall. After contaminated insulators were naturally washed by rain, leakage current was not increased.

  • PDF

Analyses of Leakage Current of Transmission Insulator as a Function of Environmental Condition (환경에 따른 송전용 애자의 누설전류 분석)

  • Choi, In-Hyuk;Lee, Dong-Il;Kim, Chan-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1166-1170
    • /
    • 2004
  • The leakage currents of transmission insulator were investigated as a function of environmental conditions, such as temperature, humidity, and rainfall. The insulators were artificially contaminated with insoluble yellow soil and kaolin which helped salt to stick on the surface of insulator. The insulators contaminated with the grade of B, C, and D were installed in the KoChang Testing Center. The leakage currents were measured and compared with non-contaminated insulators. The results indicated that the most important factor affecting leakage current was humidity. After heavy rain, the artificially contaminated salt was dissolved, resulting in similar characteristics between with and without contamination

  • PDF